Plan Review Details - Permit 17121069
| Plan Review Stops For Permit 17121069 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2018-07-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-07-13 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-07-13 |
Time |
14:08 |
Sent To |
|
|
| Notes |
| 2018-07-13 14:10:15 | | | | BUILDING PROVISO: | | | 1- THE PROPOSED ALTERATION IS A CHANGE IN OCCUPANCY | | | WITH NO CHANGE OF OCCUPANCY CLASSIFICATION. A | | | CERTIFICATE OF OCCUPANCY SHALL BE ISSUED BEFORE | | | OPERATION AS REQUIRED BY SEC. 1001.2 FBC-EXISTING | | | BUILDING. | | | | | | SEC. 1001.2 CHANGE IN OCCUPANCY WITH NO CHANGE OF | | | OCCUPANCY CLASSIFICATION. | | | A CHANGE IN OCCUPANCY, AS DEFINED IN SECTION 202, WITH | | | NO CHANGE OF OCCUPANCY CLASSIFICATION SHALL NOT BE MADE | | | TO ANY STRUCTURE THAT WILL SUBJECT THE STRUCTURE TO ANY | | | SPECIAL PROVISIONS OF THE APPLICABLE FLORIDA BUILDING | | | CODES, INCLUDING THE PROVISIONS OF SECTIONS 1002 | | | THROUGH 1011, WITHOUT THE APPROVAL OF THE CODE | | | OFFICIAL. A CERTIFICATE OF OCCUPANCY SHALL BE ISSUED | | | WHERE IT HAS BEEN DETERMINED THAT THE REQUIREMENTS FOR | | | THE CHANGE IN OCCUPANCY HAVE BEEN MET. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2018-07-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-07-06 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-07-06 |
Time |
12:32 |
Sent To |
|
|
| Notes |
| 2018-07-06 13:10:25 | THIRD BUILDING REVIEW CHECKLIST. | | | CODE: FBC 5TH EDITION (2014). | | | | | | ORIGINAL COMMENT: | | | 1- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | | LOW. REVISE AS REQUIRED. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT ADDRESSED AT ALL. | | | | | | FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING | | | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE | | | TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY | | | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST | | | PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS | | | SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | | | | | | | | | | | BUILDING PROVISO: | | | 1- THE PROPOSED ALTERATION IS A CHANGE IN OCCUPANCY | | | WITH NO CHANGE OF OCCUPANCY CLASSIFICATION. A | | | CERTIFICATE OF OCCUPANCY SHALL BE ISSUED BEFORE | | | OPERATION AS REQUIRED BY SEC. 1001.2 FBC-EXISTING | | | BUILDING. | | | | | | SEC. 1001.2 CHANGE IN OCCUPANCY WITH NO CHANGE OF | | | OCCUPANCY CLASSIFICATION. | | | A CHANGE IN OCCUPANCY, AS DEFINED IN SECTION 202, WITH | | | NO CHANGE OF OCCUPANCY CLASSIFICATION SHALL NOT BE MADE | | | TO ANY STRUCTURE THAT WILL SUBJECT THE STRUCTURE TO ANY | | | SPECIAL PROVISIONS OF THE APPLICABLE FLORIDA BUILDING | | | CODES, INCLUDING THE PROVISIONS OF SECTIONS 1002 | | | THROUGH 1011, WITHOUT THE APPROVAL OF THE CODE | | | OFFICIAL. A CERTIFICATE OF OCCUPANCY SHALL BE ISSUED | | | WHERE IT HAS BEEN DETERMINED THAT THE REQUIREMENTS FOR | | | THE CHANGE IN OCCUPANCY HAVE BEEN MET. | | | | | | | | | | | | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | | COMMENT TO HELP EXPEDITE THE REVIEW PROCESS. | | | | | | ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD | | | DRAWING. SUBMIT OLD DRAWINGS FOR REFERENCE OF ALREADY | | | REVIEWED DRAWINGS. DO NOT STAPLE OLD DRAWINGS TO PLANS. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-05-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-05-03 |
Time |
19:21 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-05-03 |
Time |
14:25 |
Sent To |
|
|
| Notes |
| 2018-05-03 19:22:01 | BUILDING REVIEW COMMENTS | | | CODE: FBC 5TH EDITION (2014). | | | | | | 1- BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, | | | ONE SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO | | | PALM BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS | | | WITH THE IMPACT FEE STAMP AND A COPY OF THE PAID | | | RECEIPT MUST BE RETURNED TO THE CITY BUILDING | | | DEPARTMENT BEFORE THE BUILDING PERMIT CAN BE ISSUED. | | | FOR INFORMATION CALL PALM BEACH COUNTY IMPACT FEES AT | | | (561) 233-5025. | | | | | | 2- ENERGY CALCULATIONS SUBMITTED: | | | A) FORM C402-2014 SUBMITTED NEED TO BE CERTIFIED AT THE | | | BOTTOM AS REQUIRED BY SEC. C103.1.1.2 FBC-ENERGY | | | CONSERVATION PRIOR TO RECEIVE THE PERMIT. | | | | | | C103.1.1.2 CODE COMPLIANCE CERTIFICATION. | | | THE BUILDING'S OWNER, THE OWNER'S ARCHITECT, OR OTHER | | | AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER SHALL | | | CERTIFY THAT THE BUILDING IS IN COMPLIANCE WITH THE | | | CODE, AS PER SECTION 553.907, FLORIDA STATUTES, PRIOR | | | TO RECEIVING THE PERMIT TO BEGIN CONSTRUCTION OR | | | RENOVATION. | | | | | | B) PROVIDE COMPLETE AND CORRECT INFORMATION ON TOP OF | | | FORM: (1) CLIMATE ZONE IS 1A NOT 8.. SEE SEC. C301.1 | | | FBC-ENERGY CONSERVATION. (2) SPECIFY THE PERMITTING | | | OFFICE. (3) THE COMPLETE PROJECT NAME IS THE YELLOW | | | DOOR RESTAURANT. (4) PROVIDE THE NAME OF THE BUILDER. | | | SEC. C103.3 FBC-ENERGY CONSERVATION. | | | | | | 3- REPEAT COMMENT. VALUATION DECLARED IN THE PERMIT | | | APPLICATION IS TOO LOW. REVISE AS REQUIRED. | | | | | | FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING | | | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE | | | TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY | | | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST | | | PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS | | | SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | | | | | 4- THE PROPOSED ALTERATION IS A CHANGE IN OCCUPANCY | | | WITH NO CHANGE OF OCCUPANCY CLASSIFICATION. A | | | CERTIFICATE OF OCCUPANCY SHALL BE ISSUED BEFORE | | | OPERATION AS REQUIRED BY SEC. 1001.2 FBC-EXISTING | | | BUILDING. | | | | | | SEC. 1001.2 CHANGE IN OCCUPANCY WITH NO CHANGE OF | | | OCCUPANCY CLASSIFICATION. | | | A CHANGE IN OCCUPANCY, AS DEFINED IN SECTION 202, WITH | | | NO CHANGE OF OCCUPANCY CLASSIFICATION SHALL NOT BE MADE | | | TO ANY STRUCTURE THAT WILL SUBJECT THE STRUCTURE TO ANY | | | SPECIAL PROVISIONS OF THE APPLICABLE FLORIDA BUILDING | | | CODES, INCLUDING THE PROVISIONS OF SECTIONS 1002 | | | THROUGH 1011, WITHOUT THE APPROVAL OF THE CODE | | | OFFICIAL. A CERTIFICATE OF OCCUPANCY SHALL BE ISSUED | | | WHERE IT HAS BEEN DETERMINED THAT THE REQUIREMENTS FOR | | | THE CHANGE IN OCCUPANCY HAVE BEEN MET. | | | | | | | | | | | | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | | COMMENT TO HELP EXPEDITE THE REVIEW PROCESS. | | | | | | ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD | | | DRAWING. SUBMIT OLD DRAWINGS FOR REFERENCE OF ALREADY | | | REVIEWED DRAWINGS. DO NOT STAPLE OLD DRAWINGS TO PLANS. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-01-08 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-01-08 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-01-05 |
Time |
15:16 |
Sent To |
|
|
| Notes |
| 2018-01-08 08:25:52 | ****PLAN REVIEW COMMENTS**** | | | | | | ART LANGE BUILDING PLANS EXAMINER | | | | | | DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FL 33402 | | | | | | 561-805-6718 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2014 5TH EDITION W/2010 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 1. OFFICE SIZE IS TOO SMALL IN BOTH DIRECTIONS. | | | | | | INTERIOR SPACE DIMENSIONS | | | FBC 1208.1 MINIMUM ROOM WIDTHS. | | | HABITABLE SPACES, OTHER THAN A KITCHEN, SHALL BE NOT | | | LESS THAN 7 FEET (2134 MM) IN ANY PLAN DIMENSION. | | | KITCHENS SHALL HAVE A CLEAR PASSAGEWAY OF NOT LESS THAN | | | 3 FEET (914 MM) BETWEEN COUNTER FRONTS AND APPLIANCES | | | OR COUNTER FRONTS AND WALLS. | | | | | | 2. HOODS / VENTILATION | | | | | | FBC 1203.5 OTHER VENTILATION AND EXHAUST SYSTEMS. | | | VENTILATION AND EXHAUST SYSTEMS FOR OCCUPANCIES AND | | | OPERATIONS INVOLVING FLAMMABLE OR COMBUSTIBLE HAZARDS | | | OR OTHER CONTAMINANT SOURCES AS COVERED IN THE FLORIDA | | | BUILDING CODE, MECHANICAL OR THE FLORIDA FIRE | | | PREVENTION CODE SHALL BE PROVIDED AS REQUIRED BY BOTH | | | CODES. | | | | | | 3. PROVIDE ELEVATION DETAILS TO SHOW HOW THE SERVICE | | | COUNTER WILL BE IN COMPLIANCE WITH FLORIDA | | | ACCESSIBILITY CODE 904.4 SALES AND SERVICE COUNTERS. | | | SALES COUNTERS AND SERVICE COUNTERS SHALL COMPLY WITH | | | 904.4.1 OR 904.4.2. THE ACCESSIBLE PORTION OF THE | | | COUNTER TOP SHALL EXTEND THE SAME DEPTH AS THE SALES OR | | | SERVICE COUNTER TOP. | | | | | | 4. INTERIOR PARTITION WALLS. | | | | | | A) ARE ALL OF THESE WALLS SHOWN NEW WALLS? CLARIFY | | | | | | B) THE WALL FRAMING DETAIL IS SHOWN AT 24 INCHES ON | | | CENTER. CEMENT BOARD IS SHOWN ON SOME WALLS. PROVIDE | | | MANUFACTURER?S SPECIFICATION ON THE PRODUCT USED SINCE | | | MANY REQUIRE FRAMING AT 16 INCHES ON CENTER. | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | | UPON SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS ARE | | | PERMITTED TO BE SUBMITTED WHEN APPROVED BY THE BUILDING | | | OFFICIAL. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT | | | CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF | | | THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL | | | CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT | | | LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED | | | BY THE BUILDING OFFICIAL. | | | | | | 5. GENERAL NOTES. PLEASE UPDATE THE FLORIDA | | | ACCESSIBILITY CODE AND ENERGY CODE TO 2014 5TH EDITION. | | | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | | UPON SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS ARE | | | PERMITTED TO BE SUBMITTED WHEN APPROVED BY THE BUILDING | | | OFFICIAL. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT | | | CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF | | | THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL | | | CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT | | | LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED | | | BY THE BUILDING OFFICIAL. | | | | | | 6. PERMIT VALUE IS TOO LOW. ADJUST VALUE WHEN YOUR | | | PLANS ARE RESUBMITTED. | | | | | | FBC 109.3 BUILDING PERMIT VALUATIONS. | | | | | | IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE | | | CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE, | | | ELECTRICAL, GAS, MECHANICAL OR PLUMBING SYSTEMS APPEARS | | | TO BE UNDERESTIMATED ON THE APPLICATION, THE PERMIT | | | SHALL BE DENIED, UNLESS THE APPLICANT CAN SHOW | | | DETAILED, QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED | | | CONTRACTS (EXCLUDING LAND VALUE) TO MEET THE APPROVAL | | | OF THE BUILDING OFFICIAL. FOR PERMITTING PURPOSES, | | | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL | | | REPLACEMENT VALUE TO INCLUDE STRUCTURAL, ELECTRIC, | | | PLUMBING, MECHANICAL, INTERIOR FINISH, RELATIVE SITE | | | WORK, ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | | (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | | INTERNATIONAL CODE CONGRESS. | | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | | BUILDING OFFICIAL. | | | | | | WHEN RESUBMITTING, PLEASE COMPLETE A RESUBMITTAL FORM: | | | | | | HTTP://WPB.ORG/DEVELOPMENT/WPCONTENT/UPLOADS/SITES/33/2 | | | 013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | THIS FORM IS ALSO AVAILABLE AT THE BUILDING DIVISION. | | | WHEN RESUBMITTING, SWAP OUT SHEETS WHICH HAVE CHANGED | | | SO THAT THERE ARE TWO COMPLETE, COLLATED SETS OF PLANS | | | READY FOR PERMIT ISSUANCE. OLD SHEETS ARE TO BE | | | RETAINED IN THE PERMIT APPLICATION PACKAGE (SEPARATE | | | FROM THE PERMIT SETS) AND MARKED *OLD SHEETS* OR | | | *VOID*. PLEASE KEEP BOTH SETS OF OLD VOIDED SHEETS IN | | | THE PERMIT PACKAGE. | | | | | | A RESPONSE LETTER INDICATING HOW EACH ITEM WAS | | | ADDRESSED WILL HELP TO EXPEDITE PLAN REVIEW. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-05-02 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-05-02 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-05-02 |
Time |
12:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-01-11 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-01-11 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-01-11 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2018-01-11 15:50:30 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. FEED FROM DISCONNECT TO PANEL A SHOWS A # 8 | | | EQUIPMENT GROUNDING CONDUCTOR. PROVIDE CORRECTION. NEC | | | 250.122 | | | 2. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | | SERVICE. NEC 250.94; FBC RE3609.3 | | | 3. SERVICE GROUNDING ELECTRODE TO BE AUGMENTED BY AN | | | ADDITIONAL ELECTRODE 6 FEET AWAY OR PROVIDE EVIDENCE OF | | | RESISTANCE TO GROUND OF 25 OHMS OR LESS. NEC 250.56 | | | 4. SHOW ALL AVAILABLE GROUNDING ELECTRODES AT LOCATION | | | WITH ATTACHMENT TO THE GROUNDING ELECTRODE CONDUCTOR. | | | NEC 250.50; FBC 107.2.1 | | | 5. PROVIDE CHART OF INTERIOR LIGHTING POWER ALLOWANCES | | | EXPRESSED IN WATTAGE PER THE FBC ENERGY CODE IN | | | RELATION TO THE WATTAGE OF THE CONNECTED INTERIOR | | | LIGHTING PROPOSED TO COMPLY WITH CODE. FBC EC 405.5.2 | | | 6. PROVIDE THE ADDITIONAL LIGHTING CONTROLS STIPULATED | | | IN THE FBC ENERGY CODE. MANY AREAS DO NOT SHOW THE | | | AUTOMATIC CONTROL REQUIRED. FBC EC 405.2.2, 405.2.2.2 | | | 7. BE ADVISED THAT FIRE ALARM, LOW VOLTAGE SYSTEMS, | | | LIGHTNING PROTECTION, GENERATORS, COMMERCIAL HOOD | | | SYSTEMS, SIGNS, SITE LIGHTING, AND SWIMMING POOLS | | | (WHERE APPLICABLE) ARE NOT INCLUDED IN THE SCOPE OF | | | THIS PLAN REVIEW. PROVIDE A BLOCK NOTE INDICATING THE | | | REQUIRED SEPARATE PERMITS AND DATA SPECIFICATION SHEET | | | SUBMITTALS FOR ANY OF THESE SYSTEMS PRESENT. FBC 105.1, | | | 107.2.1 | | | 8. PROVIDE AIC RATING OF SERVICE DISCONNECT AND PANEL. | | | NEC 110.3, 110.9 | | | 9. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10 | | | 10. PROVIDE NOTES TO INDICATE THE REQUIRED MARKING OF | | | SERVICE EQUIPMENT FOR ARC FLASH HAZARD WARNING AND | | | AVAILABLE FAULT CURRENT PER CODE. NEC 110.16, 110.24 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-04-26 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-04-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-04-25 |
Time |
15:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-01-03 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-01-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-01-03 |
Time |
11:38 |
Sent To |
|
|
| Notes |
| 2018-01-03 12:52:31 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | 1) THE HOOD VENT AND FIRE SUPPRESSION SYSTEMS SHALL BE | | | DONE UNDER SEPARATE SHOP DRAWINGS EACH. | | | | | | | | | 2) THE DOOR LOCKS INDICATES ON THE FRONT AND REAR DOORS | | | SHALL COMPLY WITH NFPA, 101, CHAPTER 7, MEANS OF EGRESS | | | | | | PER NFPA 101, CHAPRE 39, NEW BUSINESS OCCUPANCIES | | | | | | 39.2.2.2 DOORS. | | | 39.2.2.2.1 DOORS COMPLYING WITH 7.2.1 SHALL BE | | | PERMITTED. | | | 39.2.2.2.2* LOCKS COMPLYING WITH 7.2.1.5.5 SHALL BE | | | PERMITTED ONLY ON PRINCIPAL ENTRANCE/EXIT DOORS. | | | | | | 7.2.1.5 LOCKS, LATCHES, AND ALARM DEVICES. | | | 7.2.1.5.1 DOOR LEAVES SHALL BE ARRANGED TO BE OPENED | | | READILY FROM THE EGRESS SIDE WHENEVER THE BUILDING IS | | | OCCUPIED. | | | 7.2.1.5.2* THE REQUIREMENT OF 7.2.1.5.1 SHALL NOT APPLY | | | TO DOOR LEAVES OF LISTED FIRE DOOR ASSEMBLIES AFTER | | | EXPOSURE TO ELEVATED TEMPERATURE IN ACCORDANCE WITH THE | | | LISTING, BASED ON LABORATORY FIRE TEST PROCEDURES. | | | 7.2.1.5.3 LOCKS, IF PROVIDED, SHALL NOT REQUIRE THE USE | | | OF A KEY, A TOOL, OR SPECIAL KNOWLEDGE OR EFFORT FOR | | | OPERATION FROM THE EGRESS SIDE. | | | | | | 7.2.1.5.5 KEY-OPERATED LOCKS. | | | 7.2.1.5.5.1 EXTERIOR DOOR ASSEMBLIES SHALL BE PERMITTED | | | TO HAVE KEYOPERATED LOCKS FROM THE EGRESS SIDE, | | | PROVIDED THAT ALL OF THE FOLLOWING CRITERIA ARE MET: | | | (1) THIS ALTERNATIVE IS PERMITTED IN CHAPTERS 11 | | | THROUGH 43 FOR THE SPECIFIC OCCUPANCY. | | | (2) A READILY VISIBLE, DURABLE SIGN IN LETTERS NOT LESS | | | THAN 1 IN. (25 MM) HIGH ON A CONTRASTING BACKGROUND | | | THAT READS AS FOLLOWS IS LOCATED ON OR ADJACENT TO THE | | | DOOR LEAF: THIS DOOR TO REMAIN UNLOCKED WHEN THE | | | BUILDING IS | | | OCCUPIED. | | | (3) THE LOCKING DEVICE IS OF A TYPE THAT IS READILY | | | DISTINGUISHABLE AS LOCKED. | | | (4) A KEY IS IMMEDIATELY AVAILABLE TO ANY OCCUPANT | | | INSIDE THE BUILDING WHEN IT IS LOCKED. | | | 7.2.1.5.5.2 THE ALTERNATIVE PROVISIONS OF 7.2.1.5.5.1 | | | SHALL BE PERMITTED TO BE REVOKED BY THE AUTHORITY | | | HAVING JURISDICTION FOR CAUSE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2018-06-29 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-06-29 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-06-29 |
Time |
12:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2018-05-02 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-05-02 |
Time |
08:13 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-05-02 |
Time |
08:13 |
Sent To |
|
|
| Notes |
| 2018-05-02 08:25:40 | 2ND REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | PREVIOUS COMMENT NOT COMPLIED 6. SUBMIT MANUFACTURER?S | | | SPECIFICATION SHEETS FOR ALL GAS EQUIPMENT TO VERIFY | | | COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND | | | FBC-2014 FUEL GAS SEC. 402.2 YOUR RESPONSE LETTER | | | STATES THE MANUFACTURE SPECIFICATION ARE ATTACHED TO | | | THE SUBMITTAL THEY ARE NOT IN THE SUBMITTAL PACKAGE | | | PLEASE SUBMIT WE WILL HAVE TO HAVE THEM TO VERIFY CODE | | | COMPLIANCE AND BTU LOAD.\ | | | | | | NEW COMMENT: | | | | | | 1. THE BTU LOAD FOR THE GRIDDLE IS SHOWN AT 105 | | | ON THE RISER AND 60 ON THE GAS LOAD CALCULATION PLEASE | | | CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 2. THE BTU LOAD ON THE MANIFOLD ON THE RISER 7' @ 11/2 | | | 788K PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-01-22 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-01-22 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-01-22 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2018-01-22 13:48:54 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. THE GAS LOAD CALCULATIONS SHOWS 2" @ 59' THE RISER | | | SHOWS A 11/2" PIPE PLEASE CLARIFY. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | 2. THE GAS LOAD CALCULATIONS SHOWS 59' OF DEVELOPED | | | LENGTH THE CUT SECTION ON THE RISER ADD UP TO 31' | | | PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 3. THE RISER SHOWS A GRIDDLE @ 105K AND A GRIDDLE @ 60K | | | IS THERE 2 GRIDDLES PLEASE CLARIFY. PER WPB AMEND TO | | | FBC 107.2.1 | | | | | | 4. ON THE RISER THE MANIFOLD PIPING BEHIND EQUIPMENT IS | | | SHOWN AS 1" @ 788K IT SHALL BE 11/2" @ 518K PER FBC FG | | | TABLE 402.4(2) PLEASE CLARIFY. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | 5. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE | | | FBC-2014 FUEL GAS CODE SEC. 304. | | | | | | 6. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL | | | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA | | | 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-07-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-07-06 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-06-28 |
Time |
15:51 |
Sent To |
I |
|
| Notes |
| 2018-06-28 15:52:03 | RESUB ROUTED TO GJOHNSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-05-30 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-05-30 |
Time |
09:12 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-04-17 |
Time |
14:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-01-22 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-01-22 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-12-29 |
Time |
11:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2018-07-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-07-13 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-07-13 |
Time |
14:04 |
Sent To |
|
|
| Notes |
| 2018-07-13 14:08:49 | NO FEES. COUNTY STAMP DATED 7/9/18 BY MAB STATES RETAIL | | | STRIP CENTER AND ZERO FEES. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2018-07-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-07-06 |
Time |
12:45 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-07-06 |
Time |
12:45 |
Sent To |
|
|
| Notes |
| 2018-07-06 12:46:09 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. | | | | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2018-05-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-05-04 |
Time |
07:48 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-05-04 |
Time |
07:39 |
Sent To |
|
|
| Notes |
| 2018-05-04 07:49:08 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2018-04-26 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-04-26 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-04-26 |
Time |
14:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-01-16 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-01-16 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-01-16 |
Time |
10:31 |
Sent To |
|
|
| Notes |
| 2018-01-16 11:15:10 | 1ST REVIEW FBC-2014 MECHANICAL , EXISTING BUILDING, | | | ENERGY CONSERVATION CODES | | | PERMIT #17121069 | | | 1/16/18 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE PROPOSED PROJECT IS CLASSIFIED AS A CHANGE OF | | | OCCUPANCY IN ACCORDANCE WITH SECTION 202 FBC-14 | | | EXISTING BUILDING CODE. WPB BUSINESS RECORDS SHOW | | | PREVIOUS TENANT WAS A DOG GROOMING BUSINESS- PLEASE | | | CORRECT THE LEVEL 3 REFERENCE ON THE COVER SHEET. REFER | | | TO SECTION C101.4.4 FBC-14 ENERGY CONSERVATION AND | | | SUBMIT AN ENERGY EFFICIENCY COMPLIANCE REPORT. SEE | | | | | | SECTION C401.2 FOR COMPLIANCE PATH INFORMATION. | | | | | | 2) A SMOKE DETECTOR IS REQUIRED IN THE RETURN AIR | | | SYSTEM OF THE 5-TON AC SYSTEM PER SECTION 606.2.1. | | | PLEASE NOTE THAT AN EXEMPTION CAN BE APPLIED IF THE | | | MANUFACTURER'S SPECIFICATIONS INDICATE THE SYSTEM IS | | | NOT CAPABLE OF PRODUCING OVER 2000 CFMS OF SUPPLY AIR. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2018-06-29 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-06-29 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-06-29 |
Time |
12:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2018-05-02 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-05-02 |
Time |
08:25 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-05-01 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2018-05-02 08:40:35 | 2ND REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. THE WATER TEMPERING DEVICE WATTS FL1170 IS NOT A | | | CODE COMPLIANT FORR THE REQUIREMENTS OF TEMPERED WATER | | | AT THE LAVATORY'S. PER MANUFACTURE SPECIFICATIONS | | | A) IT IS A DISCONTINUED PRODUCT BECAUSE IT IS NOT LEAD | | | FREE. | | | B) IT DOES NOT MEET ASSE 1070 OR CSA B125.3 AS REQUIRED | | | BY FBC PL 614.5 | | | PLEASE NOTE ON THE PLAN THAT THE WATER-TEMPERATURE | | | LIMITING DEVICE IS REQUIRED FO THE LAVATORY'S AND MEETS | | | ASSE 1070 OR CSA B125.3 | | | | | | 2. TWO COPY'S OF THE GREASE MONKEY SIZING CALCULATION | | | SHALL BE SIGNED AND SEALED BY THE DESIGN PROFESSIONAL. | | | PER WPB AMEND TO FBC 107.2.1.2 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-01-22 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-01-22 |
Time |
12:51 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-01-22 |
Time |
08:17 |
Sent To |
|
|
| Notes |
| 2018-01-22 12:57:34 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. THIS SHALLL BE A CHANGE OF OCCUPANCY PER FBC EX 202 | | | AND 1001.2 PLEASE CHANGE PLAN TO INDICATE THIS. PER WPB | | | AMEND TO FBC 107.2.1 | | | | | | 2. VALUATION OF JOB IS LOW PLEASE PROVIDE DOCUMENTATION | | | TO SHOW VALUATION. PER WPB AMEND TO FBC 109.3 BUILDING | | | PERMIT VALUATIONS. IF, IN THE OPINION OF THE BUILDING | | | OFFICIAL, THE CLAIMED VALUATION OF | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOW | | | DETAILED, QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED | | | CONTRACTS (EXCLUDING LAND VALUE) TO MEET THE | | | APPROVAL OF THE BUILDING OFFICIAL. FOR PERMITTING | | | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL | | | BE TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING | | | ONLY LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE | | | LATEST PUBLISHED DATA OF NATIONAL CONSTRUCTION | | | COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), | | | AS PUBLISHED BY INTERNATIONAL CODE CONGRESS. | | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | | BUILDING OFFICIAL. | | | | | | 3. SHT. 1.0A SHOWS CENTER OF TOILET OFF SIDE WALL AT | | | 18" MIN IT SHALL BE 16" MIN - 18" MAX. PER FBC ACC | | | 604.2 | | | | | | 4. THE GRAB BARS SHALL BE MEASURED FROM FROM FINISHED | | | FLOOR TO TOP OF GRIPPING SURFACE PLEASE SHOW ON PLAN. | | | PER FBC ACC 609.4 | | | | | | 5. TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND | | | SHALL BE 7 INCHES MINIMUM AND 9 INCHES MAXIMUM IN FRONT | | | OF THE WATER CLOSET MEASURED TO THE CENTERLINE OF THE | | | DISPENSER. THE PLAN SHOWS 19 MIN OFF FINISHED FLOOR IT | | | SHALL BE 15 INCHES MINIMUM AND 48 INCHES MAXIMUM ABOVE | | | THE FINISH FLOOR AND SHALL NOT BE LOCATED BEHIND GRAB | | | BARS. PER FBC ACC 604.7 | | | | | | 6. THE REQUIRED TEMPERED WATER AT THE LAVATORY'S SHAL | | | BE DELIVERED BY TEMPERATURE LIMITING DEVISE COMPILING | | | WITH ASSE 1070 OR CSA B125.3. PER FBC PL 416.5 PROVIDE | | | NOTE ON PLAN. | | | | | | 7. TRAP PRIMERS ARE REQUIRED ON FLOOR DRAIN SHOW ON | | | PLAN. PER FBC PL 1002.4 | | | | | | 8. PROVIDE GREASE INTERCEPTOR CALCULATION FROM SCHIER. | | | PER WPB AMEND TO FBC 107.2.1 | | | | | | 9. A TESTPORT IS REQUIRED ON OUTLET OF GREASE | | | INTERCEPTOR IT SHALL BE A 4" MIN TWOWAY CLEAN OUT OR A | | | PRE MANUFACTURED TEST PORT. PER WPB UTIL. DEPT. PROVIDE | | | DETAIL PER MANUFACTURE INSTALLATION GUIDE. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P-GREASE |
GREASE INTERCEPTOR/TRAP REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2019-02-20 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-02-20 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-02-20 |
Time |
11:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-05-29 |
|
|
Cont ID |
|
| Sent By |
LL |
Date |
2018-05-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2018-05-29 |
Time |
|
Sent To |
|
|
| Notes |
| 2018-05-29 10:56:45 | INTERIOR MODIFICATIONS ONLY. CAFE USE PERMITTED IN | | | NMUD-TYPE I. | | | | | | | | | | | 2018-05-04 07:49:44 | CHANGE OF OCCUPANCY |
|
|
|