Plan Review Details - Permit 17121038
Plan Review Stops For Permit 17121038
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-01-29 Cont ID  
Sent By cthroop Date 2018-01-29 Time 14:51 Rev Time 0.00
Received By cthroop Date 2018-01-25 Time 13:50 Sent To  
Notes
2018-01-29 15:11:29BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. RENOVATION OF AN ACCESSORY BUILDING TO A HABITABLE
 DWELLING UNIT IS A CHANGE OF OCCUPANCY/CHANGE OF USE
 PER THE FBC EXISTING BLDG. SECTION 407.
 2. ALL STRUCTURAL ELEMENTS SHALL BE EVALUATED BY A
 LICENSED FLORIDA PROFESSIONAL ENGINEER.
 3. ENGINEER TO SUBMIT EVALUATION REPORT AS PART OF
 RE-SUBMITTAL.
 4. PROVIDE SITE PLAN.
 5. PROVIDE COPY OF CURRENT SURVEY.
 6. PROVIDE ENERGY SUBMITTAL.
 7. PROVIDE PRODUCT APPROVALS FOR EXTERIOR CLADDING,
 ROOFING, DOORS AND WINDOWS.
 8. IF WINDOWS AND DOORS ARE NOT IMPACT RATED, PROVIDE
 SCHEDULE FOR INSTALLATION OF OPENING PROTECTION
 DEVICES.
  
 FBC 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS.
 THE EXAMINATION OF THE DOCUMENTS BY THE BUILDING
 OFFICIAL SHALL INCLUDE THE FOLLOWING MINIMUM CRITERIA
 AND DOCUMENTS: A FLOOR PLAN; SITE PLAN; FOUNDATION
 PLAN; FLOOR/ROOF FRAMING PLAN OR TRUSS LAYOUT; ALL
 FENESTRATION PENETRATIONS; FLASHING; AND ROUGH OPENING
 DIMENSIONS; AND ALL EXTERIOR ELEVATIONS:
  
 FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402
 SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO
 DEMONSTRATE CODE COMPLIANCE BY THIS METHOD.
  
 _ OR _
  
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE EXTERIOR CLADDING, ROOFING,
 WINDOW AND DOOR SUBMITTALS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED AND MARK VOID.
  
2018-01-09 16:59:01SCOPE OF WORK ON PLAN MAY NOT STATE "CONVERT STORAGE
 BUILDING TO GUEST HOUSE.'

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-01-22 Cont ID  
Sent By jpearson Date 2018-01-22 Time 12:17 Rev Time 0.00
Received By jpearson Date 2018-01-22 Time 12:17 Sent To  
Notes
2018-01-22 12:16:46CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION
 NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF
 SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE,
 WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY
 SUB-PANEL. SHOW GEC SIZE AND SYSTEM, SHOW INTERSYSTEM
 BONDING TERMINATION POINT. NEC 215.5, 230, 250.50,
 250.94, 408.30 FBC RE3706.1, RE E3608.1, RE E3609.3;
 FBC 107.2.1
 2. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED
 CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS,
 AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY
 WITH CODE. PROVIDE DEDICATED 20 AMP CIRCUIT FOR
 BATHROOM RECEPTACLE. NEC 210.8, 210.11(C)(3), 210.12,
 215.5, 408.4; FBC RE E3706.2, RE E3902
 3. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE
 EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE
 IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.3,
 E3703.4
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2018-01-09 Cont ID  
Sent By destabro Date 2018-01-09 Time 13:43 Rev Time 0.00
Received By destabro Date 2018-01-09 Time 13:43 Sent To B
Notes
2018-01-09 13:47:241/8/2018 - NO EXTERIOR MODFICIATIONS PROPOSED. IF
 WINDOWS REQUIRE RELOCATION, OR IF THE EXTERIOR WILL BE
 ALTERED, PLEASE CONTACT HISTORIC PRESERVATION STAFF.
 DLE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-01-29 Cont ID  
Sent By cthroop Date 2018-01-29 Time 15:16 Rev Time 0.00
Received By cthroop Date 2017-12-29 Time 11:31 Sent To I
Notes
2018-01-02 11:31:38R02

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2018-01-29 Cont ID  
Sent By cthroop Date 2018-01-29 Time 14:51 Rev Time 0.00
Received By cthroop Date 2018-01-25 Time 13:50 Sent To  
Notes
2018-01-29 14:51:42BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT
 FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID.
 UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE
 SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN
 IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP
 AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE
 CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN
 BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY
 IMPACT FEES AT (561) 233-5025.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2018-01-05 Cont ID  
Sent By cmontell Date 2018-01-05 Time 15:17 Rev Time 0.00
Received By cmontell Date 2018-01-05 Time 14:56 Sent To  
Notes
2018-01-05 15:28:00MECHANICAL PLAN REVIEW FAILED
 1 - PROVIDE ENERGY CALCULATIONS PER FLORIDA BUILDING
 CODE ENERGY CONSERVATION SEC. R101.5.1.1.2
 2 - PROVIDE HEAT LOAD CALCULATIONS PER FLORIDA BUILDING
 CODE ENERGY CONSERVATION SEC. R403.6.1
 CHRIS MONTELLO
 [email protected]
 561-805-6733

Review Stop P PLUMBING
Rev No 1 Status P Date 2018-01-12 Cont ID  
Sent By thunt Date 2018-01-12 Time 06:44 Rev Time 0.00
Received By thunt Date 2018-01-12 Time 06:44 Sent To  
Notes
2018-01-12 06:44:59ROUTED BACK TO R02

Review Stop Z ZONING
Rev No 1 Status P Date 2018-01-09 Cont ID  
Sent By destabro Date 2018-01-09 Time 13:39 Rev Time 0.00
Received By destabro Date 2018-01-09 Time 13:39 Sent To B
Notes
2018-01-09 13:43:371/9/2018 - NO PROPOSED EXTERIOR CHANGES - INTERIOR
 MODIFICATION ONLY. WIDTH OF LOT (50') DOES NOT PERMIT A
 SEPARATE RENTABLE UNIT. PERMIT PLANS ACCURATELY REFLECT
 THE ABSENCE OF A STOVE/RANGE COOKTOP; HOWEVER, A RENTAL
 LICENSE WILL NOT BE PERMITTED FOR THIS UNIT. PLEASE
 DIRECT QUESTIONS TO DESIREE ESTABROOK, HISTORIC
 PRESERVATION PLANNER AT 561.822.1428.