Plan Review Details - Permit 17121030
| Plan Review Stops For Permit 17121030 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2019-02-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-02-06 |
Time |
07:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-02-06 |
Time |
07:03 |
Sent To |
I |
|
| Notes |
| 2019-02-06 07:26:55 | "PROVISO" | | | THE EXTERIOR DOORS AND WINDOWS ARE NOT INCLUDED UNDER | | | THIS PERMIT. A SEPARATE PERMIT, APPLICATION AND REVIEWS | | | ARE REQUIRED. THE REQUIRED COMPONENT AND CLADDING | | | WINDLOAD PRESSURES FOR THE EXTERIOR OPENINGS WILL BE | | | SUBMITTED WITH THIS PERMIT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2019-01-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-01-30 |
Time |
07:38 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-01-29 |
Time |
14:00 |
Sent To |
I |
|
| Notes |
| 2019-01-30 07:37:57 | 2014 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 17121030 | | | ADD: 200 CLEMATIS ST. / 1ST FLOOR AND MEZZANINE. | | | CONT: CONSTRUCTION TECHNOLOGIES | | | TEL: 954-709-1935 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE & 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | PLAN | | | REVIEW COMMENTS | | | 4TH REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | PLEASE COMPLY WITH: WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE ANY VOIDED SHEETS & | | | REPLACE ANY PAGES AS NECESSARY, COLLATE PLANS INTO | | | COMPLETE SETS. PLANS WILL NOT BE ISSUED IN PARTIAL | | | SETS!!!!!!!!!!! | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | IT APPEARS THAT ALL OF THE ITEMS HAVE BEEN ADDRESSED | | | EXCEPT FOR THE FOLLOWING ITEMS: | | | | | | 1) THE EXTERIOR RAMP AT THE EXIT EGRESS DOOR ON THE | | | EAST SIDE OF THE BUILDING IS STILL SHOWN ON SHEETS A1.0 | | | AND A6.0. IN ORDER TO AVOID ANY CONFUSION, PLEASE | | | REVISE THESE DRAWINGS TO REMOVE THE RAMP. FBC 107.2.1 | | | | | | 2) THE HANDWRITTEN "PROVISO" NOTE BY THE ARCHITECT TO | | | PROVIDE WINDLOAD CALCULATIONS WITH THE SEPARATE | | | WINDOW/DOOR PERMIT IS LOCATED ON SHEET A6.0. THIS WILL | | | NEED TO BE ON THE NEW DRAWINGS. FBC 107.2.1 | | | | | | 3) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2019-01-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-01-11 |
Time |
19:28 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-01-10 |
Time |
07:40 |
Sent To |
|
|
| Notes |
| 2019-01-10 18:39:00 | 2014 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 17121030 | | | ADD: 200 CLEMATIS ST. / 1ST FLOOR AND MEZZANINE. | | | CONT: CONSTRUCTION TECHNOLOGIES | | | TEL: 954-709-1935 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE & 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | PLAN | | | REVIEW COMMENTS | | | 4TH REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | PLEASE COMPLY WITH: WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE ANY VOIDED SHEETS & | | | REPLACE ANY PAGES AS NECESSARY, COLATE PLANS INTO | | | COMPLETE SETS. PLANS WILL NOT BE ISSUED IN PARTIAL | | | SETS!!!!!!!!!!! | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | IT APPEARS THAT ALL OF THE ITEMS HAVE BEEN ADDRESSED | | | EXCEPT FOR THE FOLLOWING ITEMS: | | | | | | 1) THE WIND DESIGN DATA AND OPENING PRESSURES FOR THE | | | NEW EXTERIOR DOOR OPENINGS WAS NOT ADDRESSED. THIS WILL | | | BE ADDRESSED ALONG WITH THE REQUIRED PRODUCT APPROVALS | | | ON A SEPARATE PERMIT FOR THE INSTALLATION OF THE NEW | | | DOORS PER ARCHITECT'S RESPONSE LETTER. FBC 1603.1.4 | | | | | | 2) IT HAS BEEN BROUGHT TO MY ATTENTION THAT THE RAMP AT | | | THE EXIT EGRESS DOOR ON THE EAST SIDE OF THE BUILDING | | | WILL NOT BE REQUIRED. THE 2004 FBC ACCESSIBILITY | | | SECTION 207.1 STATES THAT MEANS OF EGRESS SHALL COMPLY | | | WITH 1003.2.13 OF THE 2000 EDITION OF THE INTERNATIONAL | | | BUILDING CODE OR SECTION 1007 OF THE 2003 IBC. THESE | | | SECTIONS HAVE AN EXCEPTION WHICH STATES THAT AN | | | ACCESSIBLE MEANS OF EGRESS IS NOT REQUIRED IN | | | ALTERATIONS TO EXISTING BUILDINGS. THEREFORE, THIS DOOR | | | IS NOT BE REQUIRED TO HAVE A RAMP. PLEASE SUBMIT | | | REVISED DRAWINGS THAT DO NOT SHOW THE RAMP. (THE RAMP | | | THAT IS SHOWN EXTENDS BEYOND THE PROPERTY LINE AND THE | | | LANDING WOULD NEED TO BE 60" WIDE DUE TO THE CHANGE IN | | | DIRECTION.) FBC ACCESSIBILITY SECTION 405.7.4 | | | | | | 3) THE CALCULATIONS AND DRAWINGS THAT WERE SUBMITTED | | | FOR THE VERTICAL TYPE B GAS VENTS LOCATED ON THE | | | BUILDINGS EXTERIOR ADDRESSED THE WIND LOADS. HOWEVER, | | | THE GRAVITY LOAD OF THE THESE VERTICAL GAS VENT PIPES | | | WAS NOT ADDRESSED. SPECIFY THE TYPE OF CLAMPS THAT WILL | | | BE USED AND HOW THEY WILL SUPPORT THE WEIGHT OF THE | | | VERTICALLY INSTALLED VENTS. FBC 107.2.1.3 | | | | | | 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2018-11-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-11-05 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-11-05 |
Time |
07:16 |
Sent To |
|
|
| Notes |
| 2018-11-05 13:37:04 | 2014 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 17121030 | | | ADD: 200 CLEMATIS ST. / 1ST FLOOR AND MEZZANINE. | | | CONT: CONSTRUCTION TECHNOLOGIES | | | TEL: 954-709-1935 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 3RD REVIEW | | | DATE: MON. NOV. 05/2018 | | | ACTION: DENIED | | | | | | PLEASE COMPLY WITH: WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE ANY VOIDED SHEETS & | | | REPLACE ANY PAGES AS NECESSARY, COLATE PLANS INTO | | | COMPLETE SETS. PLANS WILL NOT BE ISSUED IN PARTIAL | | | SETS!!!!!!!!!!! | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 1) THE COVERSHEET LIST THE OF DRAWINGS INDICATES THERE | | | ARE NO MECHANICAL, PLUMBING, ELECTRICAL, PLANS TO BE | | | UNDER SEPARATE PERMIT. PLEASE NOTE THE SCOPE OF THE | | | WHOLE PROJECT IS INTERRELATED WITH ALL TRADES. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC... THE ARCHITECT OF RECORD WILL NEED | | | TO COORDINATE TRADES, AND MATERIALS. THERE HAS TO BE A | | | PROFESSIONAL DESIGNER OVER ALL OF THE PROJECT. | | | | | | 1A) COMPLIED. ENGINEERING PLANS AND CALCULATIONS. | | | | | | | | | 2-3) NOT REQUIRED, THRESHOLD BUILDING WORK ON 1ST FLOOR | | | SLAB AFFECTING THE 1ST FLOOR TENANT ONLY | | | 4) 3RD REQUEST. THE RESPONSE INDICATES THE BEER ALCOHOL | | | CONTENT IS LESS THAN 16% IN THE MARGIN OF THE RESPONSE | | | BUT NOT STATED ON THE LIFE SAFETY PLAN A1.0. | | | THE PLANS INDICATE THIS IS A NEW BREWERY BUT THE PLANS | | | ARE SILENT AS TO THE ALCOHOL CONTENT. PLEASE NOTE WHEN | | | THE BEVERAGES HAVE AN ALCOHOL CONTENT OF OVER 16 PER | | | CENT THEN THE BREWERY WOULD BE CLASSIFIED AS AN F1 | | | OCCUPANCY AND OCCUPANCY SEPARATION MAY BE REQUIRED. SEE | | | FBC-B TABLE 508.4. ONE HOUR REDUCTION FOR SPRINKLERED | | | BUILDINGS. | | | | | | 5) 3RD REQUEST. IT WOULD APPEAR THAT IN THE MECHANICAL | | | REVIEW COMMENT # 3 HAS NOT BEEN CLARIFIED WHAT IS THE | | | WORKING PRESSURE. | | | 2ND REVIEW COMMENT. QUESTION, DOESN?T ALL BREWERIES | | | REQUIRE A BOILER AND 1 HOUR RATED ROOM. THE PLANS DO | | | NOT SHOW THE BOILER NOR SIZE? PLEASE REVIEW THE 2014 | | | FBC-B TABLE 509. ROOMS WITH BOILERS WHERE THE LARGEST | | | PIECE OF EQUIPMENT IS OVER 15 PSI AND 10 HORSEPOWER | | | WOULD REQUIRE 1 HOUR SEPARATION OR AUTOMATIC SPRINKLERS | | | SYSTEM. | | | | | | 6-7)3RD. SEMI- COMPLIED / NEW COMMENT. EXTERIOR BAR | | | REMOVED AND NEW EXIT DOOR ADDED ON THE EAST SIDE OF THE | | | BUILDING. | | | 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | | 107.3.5.1.1. COMMERCIAL BUILDINGS: BUILDING. | | | 8. STRUCTURAL REQUIREMENTS SHALL INCLUDE: | | | BUILDING ENVELOPE | | | WIND REQUIREMENTS | | | | | | 7) SEMI-COMPLIED. 2014 FBC-B 1603.1.4 WIND DESIGN DATA. | | | THE SUBMITTED WIND DESIGN DOES NOT PROVIDE THE BUILDING | | | MEAN ROOF HEIGHT, NEGATIVE PRESSURES ARE TAKEN FROM THE | | | ROOF LEVEL. | | | 8A) 3RD REQUEST. THIS CAN BE A PROVISO TO BE SUBMITTED | | | AS A SUBMITTAL AFTER PERMIT ISSUANCE BUT ALL OF THE | | | WIND DESIGN CRITERIA MUST BE KNOWN FOR THE CONTRACTOR | | | TO BID THE WORK OUT. | | | 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | | OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, | | | RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS | | | OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | | APPROVALS: | | | (31)(A) EXTERIOR DOORS & MULLION | | | (B) WINDOWS | | | 7( C ) BUILDING PROVISO DEFERRED SUBMITTAL. SHEET S-2 | | | WALL MOUNT MECHANICAL EQUIPMENT STAND TO BE SHOP | | | DRAWINGS BY DELEGATE ENGINEER AND REVIEWED BY THE | | | ENGINEER OF RECORD BEFORE BEING SUBMITTED TO THE | | | BUILDING DEPARTMENT. | | | | | | 8B) NEW COMMENT DEALING WITH THE NEW EXIT DOOR ON THE | | | EAST SIDE OF THE BUILDING. WITH AN OCCUPANT LOAD OF | | | GREATER THAN 50 2 EXITS ARE REQUIRED, AND 2 ACCESSIBLE | | | EXITS ARE REQUIRED. THERE IS A 2-3 INCH DIFFERENCE IN | | | GRADE FROM THE INSIDE OF THE TENANT SPACE TO THE | | | EXTERIOR SIDEWALK, HOW WILL THIS BE MADE TO COMPLY AS | | | AN ACCESSIBLE EGRESS? | | | | | | 2014 FBC-ACCESSIBILITY CODE SECTION 207.1 MEANS OF | | | EGRESS SHALL COMPLY WITH SECTION 1003.2.13 OF THE | | | INTERNATIONAL BUILDING CODE (2000 EDITION AND 2001 | | | SUPPLEMENT) OR SECTION 1007 OF THE INTERNATIONAL | | | BUILDING CODE (2003 EDITION). | | | | | | 2003 IBC-B 1007.1 WHERE MORE THAN ONE MEANS OF EGRESS | | | IS REQUIRED BY SECTIONS 1014.1 OR 1018.1 FROM ANY | | | ACCESSIBLE SPACE, EACH ACCESSIBLE PORTION OF THE SPACE | | | SHALL BE SERVED BY NOT LESS THAN TWO MEANS OF EGRESS. | | | | | | | | | 9) PROVISO/ DEFERRED SUBMITTAL: W. P. B. 107.3.4.1 | | | PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE REGULATED | | | BY THE DCA RULE 9N-03 SHALL BE REVIEWED AND APPROVED IN | | | WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL. FL 61G1-23.015 (2) THE | | | ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND REVIEWING | | | ALL PROJECT DATA, REPORTS, SHOP DRAWINGS ETC.. | | | | | | 10) COMPLIED. | | | 11) SEMI-COMPLIED. SHEET A1.0 & A4.0 SHOWS WHAT APPEARS | | | TO BEAN ACCESSIBLE BAR SECTION FOR THE INTERIOR BUT | | | THERE IS NO INDICATION AS TO THE HEIGHT OF THE | | | ACCESSIBLE PORTION OF THE BAR. 2014 FBC-ACCESSIBILITY | | | CODE 902.3 HEIGHT. THE TOPS OF DINING SURFACES AND WORK | | | SURFACES SHALL BE 28 INCHES MINIMUM AND 34 INCHES | | | MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. | | | | | | 12) SEMI-COMPLIED. 902.1 .DINING SURFACES AND WORK | | | SURFACES SHALL COMPLY WITH 902.2 AND 902.3. ADVISORY | | | 902.1 GENERAL. DINING SURFACES INCLUDE, BUT ARE NOT | | | LIMITED TO, BARS, INCLUDING THE EXTERIOR BAR, TABLES, | | | LUNCH COUNTERS, AND BOOTHS. | | | | | | 13)(A) 3RD REQUEST. SEMI-COMPLIED. 902.2 CLEAR FLOOR OR | | | GROUND SPACE. A CLEAR FLOOR SPACE COMPLYING WITH 305 | | | POSITIONED FOR A FORWARD APPROACH SHALL BE PROVIDED. | | | KNEE AND TOE CLEARANCE COMPLYING WITH 306 SHALL BE | | | PROVIDED. | | | | | | 13)(B) 3RD REQUEST. 902.3 HEIGHT. THE TOPS OF DINING | | | SURFACES AND WORK SURFACES SHALL BE 28 INCHES MINIMUM | | | AND 34 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. | | | | | | 14A-B) COMPLIED. | | | | | | 14C) 3RD REQUEST. RESPONSE INDICATES THE EXIT DOORS ARE | | | NOTED ON SHEET A1.0 LIFE SAFETY EGRESS DRAWINGS INSTEAD | | | OF A4.0, WHERE? | | | SHEET A4.0 2014 FBC-B 1008.1.10 PANIC AND FIRE EXIT | | | HARDWARE. DOORS SERVING ROOMS OR SPACES WITH AN | | | OCCUPANT LOAD OF 50 OR MORE IN A GROUP A OCCUPANCY | | | SHALL NOT BE PROVIDED WITH A LATCH OR LOCK UNLESS IT IS | | | PANIC HARDWARE OR FIRE EXIT HARDWARE. | | | | | | 15) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-02-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-02-08 |
Time |
11:57 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-02-08 |
Time |
09:11 |
Sent To |
|
|
| Notes |
| 2018-02-08 11:37:53 | 2014 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 17121030 | | | ADD: 200 CLEMATIS ST./ 1ST FLOOR AND MEZZANINE. | | | CONT: RISKAS CONSTRUCTION CORP. | | | TEL: 561-588-5455 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: THURS. FEB. 08/ 2018 | | | ACTION: DENIED | | | | | | PLEASE: WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | 1) THE COVERSHEET LIST THE OF DRAWINGS INDICATES THERE | | | ARE NO MECHANICAL, PLUMBING, ELECTRICAL, PLANS TO BE | | | UNDER SEPARATE PERMIT. PLEASE NOTE THE SCOPE OF THE | | | WHOLE PROJECT IS INTERRELATED WITH ALL TRADES. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC... THE ARCHITECT OF RECORD WILL NEED | | | TO COORDINATE TRADES, AND MATERIALS. THERE HAS TO BE A | | | PROFESSIONAL DESIGNER OVER ALL OF THE PROJECT. | | | | | | 1A) COMPLIED. ENGINEERING PLANS AND CALCULATIONS. | | | | | | 1B) BUILDING PROVISO. 106.1 LIVE LOADS POSTED. WHERE | | | THE LIVE LOADS FOR WHICH EACH FLOOR OR PORTION THEREOF | | | OF A COMMERCIAL OR INDUSTRIAL BUILDING IS OR HAS BEEN | | | DESIGNED TO EXCEED 50 PSF, SUCH DESIGN LIVE LOADS SHALL | | | BE CONSPICUOUSLY POSTED BY THE OWNER IN THAT PART OF | | | EACH STORY IN WHICH THEY APPLY, USING DURABLE SIGNS. IT | | | SHALL BE UNLAWFUL TO REMOVE OR DEFACE SUCH NOTICES | | | | | | 106.2 ISSUANCE OF CERTIFICATE OF OCCUPANCY. A | | | CERTIFICATE OF OCCUPANCY REQUIRED BY SECTION 111 SHALL | | | NOT BE ISSUED UNTIL THE FLOOR LOAD SIGNS, REQUIRED BY | | | SECTION 106.1, HAVE BEEN INSTALLED. | | | | | | 106.3 RESTRICTIONS ON LOADING. IT SHALL BE UNLAWFUL TO | | | PLACE, OR CAUSE OR PERMIT TO BE PLACED, ON ANY FLOOR OR | | | ROOF OF A BUILDING, STRUCTURE OR PORTION THEREOF, A | | | LOAD GREATER THAN IS PERMITTED BY THIS CODE. | | | | | | 2014 FBC-B 1607.4 CONCENTRATED LIVE LOADS. FLOORS AND | | | OTHER SIMILAR SURFACES SHALL BE DESIGNED TO SUPPORT THE | | | UNIFORMLY DISTRIBUTED LIVE LOADS PRESCRIBED IN SECTION | | | 1607.3 OR THE CONCENTRATED LIVE LOADS GIVEN IN TABLE | | | 1607.1, WHICHEVER PRODUCES THE GREATER LOAD EFFECTS. | | | UNLESS OTHERWISE SPECIFIED, THE INDICATED CONCENTRATION | | | SHALL BE ASSUMED TO BE UNIFORMLY DISTRIBUTED OVER AN | | | AREA OF 21/2 FEET BY 21/2 FEET (762 MM BY 762 MM) AND | | | SHALL BE LOCATED SO AS TO PRODUCE THE MAXIMUM LOAD | | | EFFECTS IN THE STRUCTURAL MEMBERS. | | | | | | 1607.2 LOADS NOT SPECIFIED. | | | FOR OCCUPANCIES OR USES NOT DESIGNATED IN TABLE 1607.1, | | | THE LIVE LOAD SHALL BE DETERMINED IN ACCORDANCE WITH A | | | METHOD APPROVED BY THE BUILDING OFFICIAL. | | | | | | 2) 2ND REQUEST. SHEET A4.0 INDICATES THERE WILL BE | | | STRUCTURAL PLANS TO FOLLOW. PLEASE BE AWARE THAT WITH | | | THIS BEING A 8 STORY BUILDING THIS BY DEFINITION A | | | THRESHOLD BUILDING AND MEETING THESE REQUIREMENTS: | | | THRESHOLD BUILDING / FL S. S. 553.71(7) ?THRESHOLD | | | BUILDING" MEANING ANY BUILDING WHICH IS GREATER THAN | | | (3) STORIES OR 50 FT. IN HEIGHT, OR WHICH HAS AN | | | ASSEMBLY OCCUPANCY CLASSIFICATION AS DENIED IN THE | | | FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ. FT. IN | | | AREA AND AN OCCUPANT CONTENT OF GREATER THAN 500 | | | PERSONS. | | | | | | 2A) 2ND REQUEST. 109.3.6.1 THRESHOLD INSPECTION PLAN. | | | THE ENFORCING AGENCY SHALL REQUIRE A (WRITTEN/ TYPED) | | | SPECIAL INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON | | | A THRESHOLD BUILDING PURSUANT TO A STRUCTURAL | | | INSPECTION PLAN PREPARED BY THE ENGINEER OF RECORD. THE | | | STRUCTURAL INSPECTION PLAN MUST BE SUBMITTED TO THE | | | ENFORCING AGENCY PRIOR TO THE ISSUANCE OF A BUILDING | | | PERMIT FOR THE CONSTRUCTION OF A THRESHOLD BUILDING. | | | THE PURPOSE OF THE STRUCTURAL INSPECTION PLAN IS TO | | | PROVIDE SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO | | | THAT THE BUILDING CAN BE ADEQUATELY INSPECTED FOR | | | COMPLIANCE WITH THE PERMITTED DOCUMENTS. | | | | | | 2B) 2ND REQUEST: THRESHOLD INSPECTOR: WPB AMENDMENT | | | 109.3.6.2 W.P.B. CONSTRUCTION SERVICES DEPARTMENT | | | REQUEST FOR THRESHOLD BUILDINGS A SPECIAL INSPECTOR AS | | | REQUIRED BY FL S S 553.79(5) FLORIDA STATUTES TO THE | | | MINIMUM INSPECTIONS REQUIRED BY THIS CODE. THE | | | THRESHOLD INSPECTION FORMS ARE REQUIRED TO BE FILED OUT | | | BY ALL PARTIES WITH INTEREST, NOTARIZED AND RETURNED TO | | | THIS OFFICE, AND REVIEWED AND APPROVED BEFORE PERMIT | | | ISSUANCE WILL TAKE PLACE. | | | FORMS E-MAILED: [email protected] | | | SENT: 02/08/2018 10:38 AM | | | | | | 2C) 2ND REQUEST. THRESHOLD BLDG., REQUIRED STATEMENT: | | | W.P.B. AMENDMENT 110.3.7.4.4 ALL PLANS FOR THE BUILDING | | | WHICH ARE REQUIRED TO BE SIGNED AND SEALED BY THE | | | ARCHITECT OR ENGINEER OF RECORD CONTAIN A STATEMENT | | | THAT, TO THE BEST OF THE ARCHITECT'S OR ENGINEER'S | | | KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE | | | APPLICABLE FIRE-SAFETY STANDARDS AS DETERMINED BY THE | | | LOCAL AUTHORITY IN ACCORDANCE WITH THIS SECTION AND 633 | | | FLORIDA STATUTE. | | | | | | 2D) 2ND REQUEST. FOR THE SPECIAL INSPECTOR PLEASE | | | PROVIDE A RESUME' OF INSPECTION EXPERIENCE ON PREVIOUS | | | PROJECT. THE RESUME' MUST BE ACCOMPANIED BY ALL | | | CERTIFICATES AS SPECIFIED HEREIN. THE BUILDING OFFICIAL | | | OR HIS DESIGNEE WILL REVIEW THE RESUME'. AFTER THE | | | RESUME' IS REVIEWED, AN INTERVIEW WILL BE SCHEDULED. | | | UNDER NO CIRCUMSTANCES WILL AN INSPECTOR BE INTERVIEWED | | | FOR WORK WITHOUT FIRST MEETING THE ABOVE CRITERIA. | | | | | | 2E) 2ND REQUEST. THE CONTRACTOR WILL PRODUCE A JOB | | | SUMMARY OR HISTORY FOR THIS TYPE OF CONSTRUCTION. | | | | | | 2F) 2ND REQUEST. NOTE FOR PAPER PLANS 3 SETS OF | | | DOCUMENTS ARE REQUIRED. 2014 WEST PALM BEACH AMENDMENTS | | | TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION, 110.3.7 THRESHOLD BUILDINGS, GUIDELINES | | | AND POLICIES FOR PROJECTS CONCERNING SPECIAL | | | INSPECTORS. | | | | | | 2G) 2ND REQUEST. 110.3.7.4.3 ALL SHORING AND RESHORING | | | PROCEDURES, PLANS AND DETAILS SHALL BE SUBMITTED TO THE | | | ENFORCEMENT AGENCY FOR RECORDKEEPING. EACH SHORING AND | | | RESHORING INSTALLATION SHALL BE SUPERVISED, INSPECTED | | | AND CERTIFIED TO BE IN COMPLIANCE WITH THE SHORING | | | DOCUMENTS BY THE CONTRACTOR. | | | | | | 2H) 2ND REQUEST. PLEASE CALL THE CITY OF WEST PALM | | | BEACHS AUTOMATED TELEPHONE INSPECTIONS LINE (561) | | | 805-6700) FOR ALL BUILDING INSPECTIONS FOR AUDITING OF | | | JOBSITE INSPECTIONS WITHOUT THIS THE PERMIT EXPIRES IN | | | 6 MONTHS, ABANDONMENT OF JOB, NO INSPECTION ACTIVITY. | | | | | | I) 2ND REQUEST. 109.3.6 THRESHOLD BUILDINGS, OPERATING | | | GUIDELINES FOR THRESHOLD INSPECTORS #26. ASSURE THAT | | | THE DESIGNER HAS REQUIRED ON THE PLANS OR | | | SPECIFICATIONS ONE MATERIAL, APPROVED FOR FIRE STOPPING | | | PENETRATIONS, FOR WALLS AND CEILINGS. | | | | | | 3) 2ND REQUEST. SHEET A-4 INDICATES A NEW POLISHED | | | CONCRETE SLAB THE A-4 SHEET DOESN?T INDICATE ANY WIRE | | | MESH OR STEEL IN THE SLAB. THE STRUCTURAL SHEET S-2 | | | DETAIL 2 SHOWS THE STRUCTURAL STEEL FOR THE 2ND FLOOR | | | AND 3 DETAILS ON S3 DETAILS A, B & C. ALL 3 OF THESE | | | DETAILS SHOW THE NEW STEEL FRAME WORK TO BE INSTALLED | | | BENEATH THE 2ND FLOOR. THE PLAN SHOWS THE STRUCTURAL | | | SLAB, NO TOPPING OF 4 TO 5 INCHES? SHEET A2.1 IN THE | | | BOTTOM LEFT CORNER OF THE PLAN HAS A NOTE THIS AREA TO | | | BE REINFORCED BY A STRUCTURAL ENGINEER. ENGINEERING | | | PLANS ARE TO BE SUBMITTED FOR APPROVAL. PLEASE NOTE | | | THERE IS NO SHOP DRAWING STAMP REVIEWED BY THE | | | ARCHITECT OF RECORD. | | | | | | 1ST ROUND OF COMMENTS. SHEET A4.0 SHOWS THE 2ND FLOOR | | | IN THE AREA OF THE NEW TANKS ARE TO BE LOCATED, THE | | | FLOOR BEING RAISED 5 INCHES AND A LINEAR FLOOR DRAIN, | | | THE PLANS ARE SILENT, NO DETAILS FOR THE RAISED FLOOR | | | FRAMING, DECKING OR FINISH MATERIAL NOR FLOOR DRAIN | | | MATERIAL? 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 4) 2ND REQUEST. THE PLANS INDICATE THIS IS A NEW | | | BREWERY BUT THE PLANS ARE SILENT AS TO THE ALCOHOL | | | CONTENT. PLEASE NOTE WHEN THE BEVERAGES HAVE AN ALCOHOL | | | CONTENT OF OVER 16 PER CENT THEN THE BREWERY WOULD BE | | | CLASSIFIED AS AN F1 OCCUPANCY AND OCCUPANCY SEPARATION | | | MAY BE REQUIRED. SEE FBC-B TABLE 508.4. ONE HOUR | | | REDUCTION FOR SPRINKLERED BUILDINGS. | | | | | | 5) 2ND REQUEST. QUESTION, DOESN?T ALL BREWERIES REQUIRE | | | A BOILER AND 1 HOUR RATED ROOM. THE PLANS DO NOT SHOW | | | THE BOILER NOR SIZE? PLEASE REVIEW THE 2014 FBC-B TABLE | | | 509. ROOMS WITH BOILERS WHERE THE LARGEST PIECE OF | | | EQUIPMENT IS OVER 15 PSI AND 10 HORSEPOWER WOULD | | | REQUIRE 1 HOUR SEPARATION OR AUTOMATIC SPRINKLERS | | | SYSTEM. | | | | | | 6) SEMI- COMPLIED SEE COMMENT # 7. SHEETS A.1 AND A3.0 | | | BOTH SHOW A NEW BAR SYSTEM ON THE EAST SIDE OF THE | | | BUILDING. PLEASE PROVIDE A WALL DETAIL OF THE INFILL | | | WALL AND DOOR/ WINDOW SYSTEM. 107.2.1.3 ADDITIONAL | | | INFORMATION IS REQUIRED. | | | 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | | 107.3.5.1.1. COMMERCIAL BUILDINGS: BUILDING. | | | 8. STRUCTURAL REQUIREMENTS SHALL INCLUDE: | | | BUILDING ENVELOPE | | | WIND REQUIREMENTS | | | | | | 7) SEMI-COMPLIED. 2014 FBC-B 1603.1.4 WIND DESIGN DATA. | | | 7.5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR | | | COMPONENTS AND CLADDING. 1609.3.1 WIND SPEED CONVERSION | | | VULT TO VASD. | | | | | | 8) 2ND REQUEST. 2014 FBC-B 1609.1.2 PROTECTION OF | | | OPENINGS, 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA | | | DEPARTMENT OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE | | | 61G20-3.005, RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY | | | OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE | | | PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS , | | | (B) WINDOWS | | | ( C ) MECHANICAL EQUIPMENT STAND WALL MOUNT SHEETS A1, | | | A3 & A4 ALL REFER TO THE ENGINEERING PLAN. NOTHING FOR | | | A MECHANICAL WALL MOUNT STAND IN THE STRUCTURAL PLANS | | | OR M1 PLAN. | | | | | | 9) 2ND REQUEST. W. P. B. 107.3.4.1 PRODUCT APPROVALS. | | | THOSE PRODUCTS WHICH ARE REGULATED BY THE DCA RULE | | | 9N-03 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. FL 61G1-23.015 (2) THE | | | ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND REVIEWING | | | ALL PROJECT DATA, REPORTS, SHOP DRAWINGS ETC.. | | | | | | 10) 2ND REQUEST. SHEET A1.0 INDICATES THERE ARE 180 | | | INDOOR SEATS AND THE PLAN SHOWS 84 EXTERIOR SEATS WITH | | | A TOTAL OF 264 SEATS. THE ACCESSIBILITY CODE REQUIRES | | | 0.05 % OF ALL SEATING TO BE ACCESSIBLE. 13.2 OR 14 | | | SEATS ALWAYS ROUND UP. 226.1 WHERE DINING SURFACES ARE | | | PROVIDED FOR THE CONSUMPTION OF FOOD OR DRINK, AT LEAST | | | 5 PERCENT OF THE SEATING SPACES AND STANDING SPACES AT | | | THE DINING SURFACES SHALL COMPLY WITH 902. | | | | | | 11) SEMI-COMPLIED. SHEET A-4.0 SHOWS A ACCESSIBLE BAR | | | SECTION FOR THE INTERIOR BARS BUT NOT THE EXTERIOR | | | BARS. 226.2 DISPERSION. DINING SURFACES AND WORK | | | SURFACES REQUIRED TO COMPLY WITH 902 SHALL BE DISPERSED | | | THROUGHOUT THE SPACE OR FACILITY CONTAINING DINING | | | SURFACES AND WORK SURFACES. | | | | | | 12) 2ND REQUEST. 902.1 .DINING SURFACES AND WORK | | | SURFACES SHALL COMPLY WITH 902.2 AND 902.3. ADVISORY | | | 902.1 GENERAL. DINING SURFACES INCLUDE, BUT ARE NOT | | | LIMITED TO, BARS, INCLUDING THE EXTERIOR BAR, TABLES, | | | LUNCH COUNTERS, AND BOOTHS. | | | | | | 13)(A) 2ND REQUEST. 902.2 CLEAR FLOOR OR GROUND SPACE. | | | A CLEAR FLOOR SPACE COMPLYING WITH 305 POSITIONED FOR A | | | FORWARD APPROACH SHALL BE PROVIDED. KNEE AND TOE | | | CLEARANCE COMPLYING WITH 306 SHALL BE PROVIDED. | | | | | | 13)(B)2ND REQUEST. 902.3 HEIGHT. THE TOPS OF DINING | | | SURFACES AND WORK SURFACES SHALL BE 28 INCHES MINIMUM | | | AND 34 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. | | | | | | 14A-B) COMPLIED. | | | | | | 14C) 2ND REQUEST. SHEET A4.0 2014 FBC-B 1008.1.10 PANIC | | | AND FIRE EXIT HARDWARE. DOORS SERVING ROOMS OR SPACES | | | WITH AN OCCUPANT LOAD OF 50 OR MORE IN A GROUP A | | | OCCUPANCY SHALL NOT BE PROVIDED WITH A LATCH OR LOCK | | | UNLESS IT IS PANIC HARDWARE OR FIRE EXIT HARDWARE. | | | | | | 15) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-01-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-01-12 |
Time |
13:58 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-01-11 |
Time |
13:50 |
Sent To |
|
|
| Notes |
| 2018-01-12 13:58:46 | 2014 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 17121030 | | | ADD: 200 CLEMATIS ST./ 1ST FLOOR AND MEZZANINE. | | | CONT: RISKAS CONSTRUCTION CORP. | | | TEL: 561-588-5455 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: FRI. JAN. 12/ 2018 | | | ACTION: DENIED | | | | | | 1) THE COVERSHEET LIST THE OF DRAWINGS INDICATES THERE | | | ARE NO MECHANICAL, PLUMBING, ELECTRICAL, PLANS TO BE | | | UNDER SEPARATE PERMIT. PLEASE NOTE THE SCOPE OF THE | | | WHOLE PROJECT IS INTERRELATED WITH ALL TRADES. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC... THE ARCHITECT OF RECORD WILL NEED | | | TO COORDINATE TRADES, AND MATERIALS. THERE HAS TO BE A | | | PROFESSIONAL DESIGNER OVER ALL OF THE PROJECT. | | | | | | 2A) SHEET A-4 INDICATES THERE WILL BE FUTURE | | | ENGINEERING PLANS BUT THERE ARE NO ENGINEERING SHEETS | | | IN THIS SET OF PLANS. TERMS THAT NEED TO BE DEFINED IS: | | | BBL/ BARREL PLEASE PROVIDE THE GALLONS IN U. S. GALLONS | | | AND WEIGHT FOR 5BBL, 10 BBL & 20 BBL. FOR THIS REVIEW I | | | WILL USE 50 GALLONS = 1 BARREL. | | | | | | TANK SIZES ARE AS FOLLOWS (ASSUMED) : | | | | | | 5 BBL 5X50GAL/ BBL= 250 GAL, 250 X 8.34 LBS/ GAL= 2,000 | | | LBS. + TANK WEIGHT | | | 10 BBL 10 X50GAL/BBL= 500 GAL. 500X 8.34 LBS/ GAL = | | | 4,170 LBS. + TANK WEIGHT | | | 20 BBL 20X50 GAL/BBL= 1000 GAL. 1000X 8.34 LBS/ GAL = | | | 8,340 LBS. + TANK WEIGHT | | | | | | PLEASE PROVIDE THE ACTUAL WEIGHT THAT WILL BE ADDING TO | | | THE EXISTING FLOOR. | | | | | | 2B) 106.1 LIVE LOADS POSTED. WHERE THE LIVE LOADS FOR | | | WHICH EACH FLOOR OR PORTION THEREOF OF A COMMERCIAL OR | | | INDUSTRIAL BUILDING IS OR HAS BEEN DESIGNED TO EXCEED | | | 50 PSF, SUCH DESIGN LIVE LOADS SHALL BE CONSPICUOUSLY | | | POSTED BY THE OWNER IN THAT PART OF EACH STORY IN WHICH | | | THEY APPLY, USING DURABLE SIGNS. IT SHALL BE UNLAWFUL | | | TO REMOVE OR DEFACE SUCH NOTICES | | | | | | 106.2 ISSUANCE OF CERTIFICATE OF OCCUPANCY. A | | | CERTIFICATE OF OCCUPANCY REQUIRED BY SECTION 111 SHALL | | | NOT BE ISSUED UNTIL THE FLOOR LOAD SIGNS, REQUIRED BY | | | SECTION 106.1, HAVE BEEN INSTALLED. | | | | | | 106.3 RESTRICTIONS ON LOADING. IT SHALL BE UNLAWFUL TO | | | PLACE, OR CAUSE OR PERMIT TO BE PLACED, ON ANY FLOOR OR | | | ROOF OF A BUILDING, STRUCTURE OR PORTION THEREOF, A | | | LOAD GREATER THAN IS PERMITTED BY THIS CODE. | | | | | | 2014 FBC-B 1607.4 CONCENTRATED LIVE LOADS. FLOORS AND | | | OTHER SIMILAR SURFACES SHALL BE DESIGNED TO SUPPORT THE | | | UNIFORMLY DISTRIBUTED LIVE LOADS PRESCRIBED IN SECTION | | | 1607.3 OR THE CONCENTRATED LIVE LOADS GIVEN IN TABLE | | | 1607.1, WHICHEVER PRODUCES THE GREATER LOAD EFFECTS. | | | UNLESS OTHERWISE SPECIFIED, THE INDICATED CONCENTRATION | | | SHALL BE ASSUMED TO BE UNIFORMLY DISTRIBUTED OVER AN | | | AREA OF 21/2 FEET BY 21/2 FEET (762 MM BY 762 MM) AND | | | SHALL BE LOCATED SO AS TO PRODUCE THE MAXIMUM LOAD | | | EFFECTS IN THE STRUCTURAL MEMBERS. | | | | | | 1607.2 LOADS NOT SPECIFIED. | | | FOR OCCUPANCIES OR USES NOT DESIGNATED IN TABLE 1607.1, | | | THE LIVE LOAD SHALL BE DETERMINED IN ACCORDANCE WITH A | | | METHOD APPROVED BY THE BUILDING OFFICIAL. | | | | | | 2) SHEET A4.0 INDICATES THERE WILL BE STRUCTURAL PLANS | | | TO FOLLOW. PLEASE BE AWARE THAT WITH THIS BEING A 8 | | | STORY BUILDING THIS BY DEFINITION A THRESHOLD BUILDING | | | AND MEETING THESE REQUIREMENTS: | | | THRESHOLD BUILDING / FL S. S. 553.71(7) ?THRESHOLD | | | BUILDING" MEANING ANY BUILDING WHICH IS GREATER THAN | | | (3) STORIES OR 50 FT. IN HEIGHT, OR WHICH HAS AN | | | ASSEMBLY OCCUPANCY CLASSIFICATION AS DENIED IN THE | | | FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ. FT. IN | | | AREA AND AN OCCUPANT CONTENT OF GREATER THAN 500 | | | PERSONS. | | | | | | 2A) 109.3.6.1 THRESHOLD INSPECTION PLAN. THE ENFORCING | | | AGENCY SHALL REQUIRE A (WRITTEN/ TYPED) SPECIAL | | | INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON A | | | THRESHOLD BUILDING PURSUANT TO A STRUCTURAL INSPECTION | | | PLAN PREPARED BY THE ENGINEER OF RECORD. THE STRUCTURAL | | | INSPECTION PLAN MUST BE SUBMITTED TO THE ENFORCING | | | AGENCY PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR | | | THE CONSTRUCTION OF A THRESHOLD BUILDING. THE PURPOSE | | | OF THE STRUCTURAL INSPECTION PLAN IS TO PROVIDE | | | SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO THAT | | | THE BUILDING CAN BE ADEQUATELY INSPECTED FOR COMPLIANCE | | | WITH THE PERMITTED DOCUMENTS. | | | | | | 2B) THRESHOLD INSPECTOR: WPB AMENDMENT 109.3.6.2 W.P.B. | | | CONSTRUCTION SERVICES DEPARTMENT REQUEST FOR THRESHOLD | | | BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY FL S S | | | 553.79(5) FLORIDA STATUTES TO THE MINIMUM INSPECTIONS | | | REQUIRED BY THIS CODE. THE THRESHOLD INSPECTION FORMS | | | ARE REQUIRED TO BE FILED OUT BY ALL PARTIES WITH | | | INTEREST, NOTARIZED AND RETURNED TO THIS OFFICE, AND | | | REVIEWED AND APPROVED BEFORE PERMIT ISSUANCE WILL TAKE | | | PLACE. | | | FORMS E-MAILED: | | | | | | 2C) THRESHOLD BLDG., REQUIRED STATEMENT: W.P.B. | | | AMENDMENT 110.3.7.4.4 ALL PLANS FOR THE BUILDING WHICH | | | ARE REQUIRED TO BE SIGNED AND SEALED BY THE ARCHITECT | | | OR ENGINEER OF RECORD CONTAIN A STATEMENT THAT, TO THE | | | BEST OF THE ARCHITECT'S OR ENGINEER'S KNOWLEDGE, THE | | | PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE | | | FIRE-SAFETY STANDARDS AS DETERMINED BY THE LOCAL | | | AUTHORITY IN ACCORDANCE WITH THIS SECTION AND 633 | | | FLORIDA STATUTE. | | | | | | 2D) FOR THE SPECIAL INSPECTOR PLEASE PROVIDE A RESUME' | | | OF INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE | | | RESUME' MUST BE ACCOMPANIED BY ALL CERTIFICATES AS | | | SPECIFIED HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE | | | WILL REVIEW THE RESUME'. AFTER THE RESUME' IS REVIEWED, | | | AN INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES | | | WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST | | | MEETING THE ABOVE CRITERIA. | | | | | | 2E) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR | | | HISTORY FOR THIS TYPE OF CONSTRUCTION. | | | | | | 2F) NOTE FOR PAPER PLANS 3 SETS OF DOCUMENTS ARE | | | REQUIRED. 2014 WEST PALM BEACH AMENDMENTS TO THE | | | FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION, | | | 110.3.7 THRESHOLD BUILDINGS, GUIDELINES AND POLICIES | | | FOR PROJECTS CONCERNING SPECIAL INSPECTORS. | | | | | | 2G) 110.3.7.4.3 ALL SHORING AND RESHORING PROCEDURES, | | | PLANS AND DETAILS SHALL BE SUBMITTED TO THE ENFORCEMENT | | | AGENCY FOR RECORDKEEPING. EACH SHORING AND RESHORING | | | INSTALLATION SHALL BE SUPERVISED, INSPECTED AND | | | CERTIFIED TO BE IN COMPLIANCE WITH THE SHORING | | | DOCUMENTS BY THE CONTRACTOR. | | | | | | 2H) PLEASE CALL THE CITY OF WEST PALM BEACH?S AUTOMATED | | | TELEPHONE INSPECTIONS LINE (561) 805-6700) FOR ALL | | | BUILDING INSPECTIONS FOR AUDITING OF JOBSITE | | | INSPECTIONS WITHOUT THIS THE PERMIT EXPIRES IN 6 | | | MONTHS, ABANDONMENT OF JOB, NO INSPECTION ACTIVITY. | | | | | | I) 109.3.6 THRESHOLD BUILDINGS, OPERATING GUIDELINES | | | FOR THRESHOLD INSPECTORS #26. ASSURE THAT THE DESIGNER | | | HAS REQUIRED ON THE PLANS OR SPECIFICATIONS ONE | | | MATERIAL, APPROVED FOR FIRE STOPPING PENETRATIONS, FOR | | | WALLS AND CEILINGS. | | | | | | 3) SHEET A4.0 SHOWS THE 2ND FLOOR IN THE AREA OF THE | | | NEW TANKS ARE TO BE LOCATED, THE FLOOR BEING RAISED 5 | | | INCHES AND A LINEAR FLOOR DRAIN, THE PLANS ARE SILENT, | | | NO DETAILS FOR THE RAISED FLOOR FRAMING, DECKING OR | | | FINISH MATERIAL NOR FLOOR DRAIN MATERIAL? 107.2.1.3 | | | ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 4) THE PLANS INDICATE THIS IS A NEW BREWERY BUT THE | | | PLANS ARE SILENT AS TO THE ALCOHOL CONTENT. PLEASE NOTE | | | WHEN THE BEVERAGES HAVE AN ALCOHOL CONTENT OF OVER 16 | | | PER CENT THEN THE BREWERY WOULD BE CLASSIFIED AS AN F1 | | | OCCUPANCY AND OCCUPANCY SEPARATION MAY BE REQUIRED. SEE | | | FBC-B TABLE 508.4. ONE HOUR REDUCTION FOR SPRINKLERED | | | BUILDINGS. | | | | | | 5) QUESTION, DOESN?T ALL BREWERIES REQUIRE A BOILER AND | | | 1 HOUR RATED ROOM. THE PLANS DO NOT SHOW THE BOILER NOR | | | SIZE? PLEASE REVIEW THE 2014 FBC-B TABLE 509. ROOMS | | | WITH BOILERS WHERE THE LARGEST PIECE OF EQUIPMENT IS | | | OVER 15 PSI AND 10 HORSEPOWER WOULD REQUIRE 1 HOUR | | | SEPARATION OR AUTOMATIC SPRINKLERS SYSTEM. | | | | | | 6) SHEETS A.1 AND A3.0 BOTH SHOW A NEW BAR SYSTEM ON | | | THE EAST SIDE OF THE BUILDING. PLEASE PROVIDE A WALL | | | DETAIL OF THE INFILL WALL AND DOOR/ WINDOW SYSTEM. | | | 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. | | | 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | | 107.3.5.1.1. COMMERCIAL BUILDINGS: BUILDING. | | | 8. STRUCTURAL REQUIREMENTS SHALL INCLUDE: | | | BUILDING ENVELOPE | | | WIND REQUIREMENTS | | | | | | 7) MISSING THE WIND DESIGN. PLEASE NOTE THE NEGATIVE | | | PRESSURES ARE TAKEN FROM THE ROOF. | | | 2014 FBC-B 1603.1.4 WIND DESIGN DATA. | | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | | DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE | | | STRUCTURE: | | | | | | 7.1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), | | | MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED, | | | VASD, AS DETERMINED IN ACCORDANCE WITH SECTION | | | 1609.3.1. | | | | | | 7.2. RISK CATEGORY. | | | | | | 7.3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE | | | THAN ONE WIND EXPOSURE IS UTILIZED. TABLE 1609.7.2. | | | HEIGHT AND EXPOSURE. | | | | | | 7.4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. | | | | | | 7.5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR | | | COMPONENTS AND CLADDING MATERIALS NOT SPECIFICALLY | | | DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL | | | RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF. | | | | | | TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT & | | | EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE | | | BUILDING. | | | | | | 1609.3.1 WIND SPEED CONVERSION VULT TO VASD. | | | | | | 8) 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | | OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, | | | RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS | | | OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | | APPROVALS: | | | (31)(A) EXTERIOR DOORS , | | | (B) WINDOWS | | | ( C ) MECHANICAL EQUIPMENT STAND WALL MOUNT | | | | | | 9) W. P. B. 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 10) SHEET A1.0 INDICATES THERE ARE 180 INDOOR SEATS AND | | | THE PLAN SHOWS 84 EXTERIOR SEATS WITH A TOTAL | | | 264 SEATS. THE ACCESSIBILITY CODE REQUIRES 0.05 % OF | | | ALL SEATING TO BE ACCESSIBLE. 13.2 OR 14 SEATS ALWAYS | | | ROUND UP. 226.1 WHERE DINING SURFACES ARE PROVIDED FOR | | | THE CONSUMPTION OF FOOD OR DRINK, AT LEAST 5 PERCENT OF | | | THE SEATING SPACES AND STANDING SPACES AT THE DINING | | | SURFACES SHALL COMPLY WITH 902. | | | | | | 11) 226.2 DISPERSION. DINING SURFACES AND WORK SURFACES | | | REQUIRED TO COMPLY WITH 902 SHALL BE DISPERSED | | | THROUGHOUT THE SPACE OR FACILITY CONTAINING DINING | | | SURFACES AND WORK SURFACES. | | | | | | 12) 902.1 .DINING SURFACES AND WORK SURFACES SHALL | | | COMPLY WITH 902.2 AND 902.3. ADVISORY 902.1 GENERAL. | | | DINING SURFACES INCLUDE, BUT ARE NOT LIMITED TO, BARS, | | | INCLUDING THE EXTERIOR BAR, TABLES, LUNCH COUNTERS, AND | | | BOOTHS. | | | | | | 13)(A) 902.2 CLEAR FLOOR OR GROUND SPACE. A CLEAR FLOOR | | | SPACE COMPLYING WITH 305 POSITIONED FOR A FORWARD | | | APPROACH SHALL BE PROVIDED. KNEE AND TOE CLEARANCE | | | COMPLYING WITH 306 SHALL BE PROVIDED. | | | | | | 13)(B) 902.3 HEIGHT. THE TOPS OF DINING SURFACES AND | | | WORK SURFACES SHALL BE 28 INCHES MINIMUM AND 34 INCHES | | | MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. | | | | | | 14) SHEET A2.1 THE UPSTAIRS SHOWS A NEW FIRE RATED EXIT | | | DOOR. NO NOTATION AS TO THE SIZE OF DOOR OR HARDWARE | | | FOR THE FIRE RATED DOOR. | | | | | | 14A) 2014 FBC-B TABLE 716.5 OPENING PROTECTIVES. | | | | | | 14B) 2014 FBC-B 1008.1.1 SIZE OF DOORS. THE MINIMUM | | | WIDTH OF EACH DOOR OPENING SHALL BE SUFFICIENT FOR THE | | | OCCUPANT LOAD THEREOF AND SHALL PROVIDE A CLEAR WIDTH | | | OF 32 INCHES (813 MM). CLEAR OPENINGS OF DOORWAYS WITH | | | SWINGING DOORS SHALL BE MEASURED BETWEEN THE FACE OF | | | THE DOOR AND THE STOP, WITH THE DOOR OPEN 90 DEGREES. | | | | | | 14C) 2014 FBC-B 1008.1.10 PANIC AND FIRE EXIT HARDWARE. | | | DOORS SERVING ROOMS OR SPACES WITH AN OCCUPANT LOAD OF | | | 50 OR MORE IN A GROUP A OCCUPANCY SHALL NOT BE PROVIDED | | | WITH A LATCH OR LOCK UNLESS IT IS PANIC HARDWARE OR | | | FIRE EXIT HARDWARE. | | | | | | 15) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2019-01-14 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-01-14 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-01-14 |
Time |
08:13 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-10-07 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-10-07 |
Time |
12:48 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-10-07 |
Time |
12:48 |
Sent To |
|
|
| Notes |
| 2018-10-07 12:48:36 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. MANY AREAS OF THE PLAN ARE SO LIGHT AS TO BE | | | UNREADABLE. PROVIDE PLANS IN LINE WITH THE WEST PALM | | | BEACH AMENDMENTS TO THE FBC: 107.2.1.4 QUALITY OF | | | BUILDING PLANS. BUILDING PLANS SHALL BE DRAWN TO A | | | MINIMUM 1/8 INCH SCALE UPON SUBSTANTIAL PAPER, CLOTH OR | | | OTHER ACCEPTABLE MEDIUM. THIS POLICY MAY INCLUDE SUCH | | | THINGS AS MINIMUM SIZE, SHAPE, CONTRAST, CLARITY, OR | | | OTHER ITEMS RELATED TO RECORDS MANAGEMENT. FBC 107.2.1 | | | (PLAN PROVIDED HAS SOME DUPLICATE SHEETS WITH | | | CONFLICTING INFORMATION. REMOVE OLD SHEETS.) | | | 2. PLAN SHOWS THE 1000 AMP FEED AS (4)400 KCMIL AND A | | | 2/0 IN AN EXISTING 2" CONDUIT. THE TOTAL AREA OF THESE | | | WIRES EXCEEDS THE ALLOWABLE SPACE OF 2" CONDUIT, SO A | | | LARGER SIZE CONDUIT IS REQUIRED. PROVIDE CORRECTION. | | | NEC CHAPTER 9, TABLE 2 AND 4. (PLAN PROVIDED HAS SOME | | | DUPLICATE SHEETS WITH CONFLICTING INFORMATION. REMOVE | | | OLD SHEETS.) | | | 3. PLAN SHOWS AN EXISTING 1000 AMP PANEL THAT HAS AN | | | 800 AMP DISCONNECT BEING CHANGED TO A 1000 AMP | | | DISCONNECT FOR NEW FEED. PROVIDE LOAD CALCULATION FOR | | | THIS SERVICE TO CONFIRM THE CAPACITY OF THIS IS | | | ADEQUATE FOR THE ADDITIONAL LOAD. LOAD CALCULATION | | | SHOULD SHOW THE PROPER DEMAND FACTORS, INCLUDING 100% | | | OF THE NON-CONTINUOUS LOAD AND 125% OF THE CONTINUOUS | | | LOAD FOR SIZING OF FEEDERS. NEC 215.2, 220, 408.30; FBC | | | 107.2.1 (PLAN PROVIDED HAS SOME DUPLICATE SHEETS WITH | | | CONFLICTING INFORMATION. REMOVE OLD SHEETS. LOAD | | | CALCULATION NOT PROVIDED FOR MAIN SERVICE AS | | | REQUESTED.) | | | 4. PROVIDE LOAD CALCULATION OF NEW PANELS BEING ADDED | | | TO CONFIRM FEEDER AND OCP IS SIZED PROPERLY. NEC 215.2, | | | 220, 408.30; FBC 107.2.1 (PLAN PROVIDED HAS SOME | | | DUPLICATE SHEETS WITH CONFLICTING INFORMATION. REMOVE | | | OLD SHEETS.) | | | 5. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10 (PLAN PROVIDED HAS SOME DUPLICATE | | | SHEETS WITH CONFLICTING INFORMATION. REMOVE OLD | | | SHEETS.) | | | 6. INDICATE WIRE SIZES ON PLAN FOR ANY CIRCUITS TO BE | | | INSTALLED. NEC 215.2, 310.15(B)(16); FBC 107.2.1 (PLAN | | | PROVIDED HAS SOME DUPLICATE SHEETS WITH CONFLICTING | | | INFORMATION. REMOVE OLD SHEETS.) | | | 7. BE ADVISED THAT FIRE ALARM, LOW VOLTAGE SYSTEMS, | | | DAS, LIGHTNING PROTECTION, GENERATORS, COMMERCIAL HOOD | | | SYSTEMS, SIGNS, SITE LIGHTING, AND SWIMMING POOLS | | | (WHERE APPLICABLE) ARE NOT INCLUDED IN THE SCOPE OF | | | THIS PLAN REVIEW. PROVIDE A BLOCK NOTE INDICATING THE | | | REQUIRED SEPARATE PERMITS AND DATA SPECIFICATION SHEET | | | SUBMITTALS FOR ANY OF THESE SYSTEMS PRESENT. FBC 105.1, | | | 107.2.1 (PLAN PROVIDED HAS SOME DUPLICATE SHEETS WITH | | | CONFLICTING INFORMATION. REMOVE OLD SHEETS.) | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-02-02 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-02-02 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-02-02 |
Time |
15:15 |
Sent To |
|
|
| Notes |
| 2018-02-02 15:15:55 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. MANY AREAS OF THE PLAN ARE SO LIGHT AS TO BE | | | UNREADABLE. PROVIDE PLANS IN LINE WITH THE WEST PALM | | | BEACH AMENDMENTS TO THE FBC: 107.2.1.4 QUALITY OF | | | BUILDING PLANS. BUILDING PLANS SHALL BE DRAWN TO A | | | MINIMUM 1/8 INCH SCALE UPON SUBSTANTIAL PAPER, CLOTH OR | | | OTHER ACCEPTABLE MEDIUM. THIS POLICY MAY INCLUDE SUCH | | | THINGS AS MINIMUM SIZE, SHAPE, CONTRAST, CLARITY, OR | | | OTHER ITEMS RELATED TO RECORDS MANAGEMENT. FBC 107.2.1 | | | 2. PLAN SHOWS THE 1000 AMP FEED AS (4)400 KCMIL AND A | | | 2/0 IN AN EXISTING 2 ? CONDUIT. THE TOTAL AREA OF THESE | | | WIRES EXCEEDS THE ALLOWABLE SPACE OF 2 ? CONDUIT, SO A | | | LARGER SIZE CONDUIT IS REQUIRED. PROVIDE CORRECTION. | | | NEC CHAPTER 9, TABLE 2 AND 4. | | | 3. PLAN SHOWS AN EXISTING 1000 AMP PANEL THAT HAS AN | | | 800 AMP DISCONNECT BEING CHANGED TO A 1000 AMP | | | DISCONNECT FOR NEW FEED. PROVIDE LOAD CALCULATION FOR | | | THIS SERVICE TO CONFIRM THE CAPACITY OF THIS IS | | | ADEQUATE FOR THE ADDITIONAL LOAD. LOAD CALCULATION | | | SHOULD SHOW THE PROPER DEMAND FACTORS, INCLUDING 100% | | | OF THE NON-CONTINUOUS LOAD AND 125% OF THE CONTINUOUS | | | LOAD FOR SIZING OF FEEDERS. NEC 215.2, 220, 408.30; FBC | | | 107.2.1 | | | 4. PROVIDE LOAD CALCULATION OF NEW PANELS BEING ADDED | | | TO CONFIRM FEEDER AND OCP IS SIZED PROPERLY. NEC 215.2, | | | 220, 408.30; FBC 107.2.1 | | | 5. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10 | | | 6. INDICATE WIRE SIZES ON PLAN FOR ANY CIRCUITS TO BE | | | INSTALLED. NEC 215.2, 310.15(B)(16); FBC 107.2.1 | | | 7. BE ADVISED THAT FIRE ALARM, LOW VOLTAGE SYSTEMS, | | | DAS, LIGHTNING PROTECTION, GENERATORS, COMMERCIAL HOOD | | | SYSTEMS, SIGNS, SITE LIGHTING, AND SWIMMING POOLS | | | (WHERE APPLICABLE) ARE NOT INCLUDED IN THE SCOPE OF | | | THIS PLAN REVIEW. PROVIDE A BLOCK NOTE INDICATING THE | | | REQUIRED SEPARATE PERMITS AND DATA SPECIFICATION SHEET | | | SUBMITTALS FOR ANY OF THESE SYSTEMS PRESENT. FBC 105.1, | | | 107.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2018-12-31 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-12-31 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-12-31 |
Time |
13:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2018-09-21 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-09-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-09-21 |
Time |
13:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-02-07 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-02-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-02-06 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2018-02-07 08:41:14 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | | | | 1) ALL FIRE ALARM AND FIRE SPRINKLER WORK SHALL BE DONE | | | UNDER SEPARATE SHOP DRAWINGS BY CERTIFIED LIFE SAFETY | | | CONTRACTORS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-01-08 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-01-08 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-01-08 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2018-01-08 13:34:13 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | | | | 1) ALL FIRE ALARM AND FIRE SPRINKLER WORK SHALL BE DONE | | | UNDER SEPARATE SHOP DRAWINGS BY CERTIFIED LIFE SAFETY | | | CONTRACTORS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2019-01-16 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2019-01-16 |
Time |
12:51 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2019-01-16 |
Time |
09:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2018-10-29 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-10-29 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-10-29 |
Time |
09:11 |
Sent To |
|
|
| Notes |
| 2018-10-29 09:26:32 | | | | 1) CUT SHEETS FOR THE BREW TANKS HAVE BEEN PROVIDED | | | EACH INDICATING THAT THEY ARE PRESSURE VESSELS AND | | | WOULD REQUIRE CERTIFICATION IN ACCORDANCE WITH THE ASME | | | BOILER AND PRESSURE VESSEL CODE. THE CUT SHEETS DO NOT | | | INDICATE THE TANKS HAVE THAT CERTIFICATION. PLEASE NOTE | | | THAT HOT TANKS D AND E DO NOT LIST THE WORKING | | | PRESSURES. | | | | | | 2) PROVIDE THE CLEARANCE DISTANCE FOR THE COMBUSTION | | | AIR OPENING TO THE PROPERTY LINE. | | | | | | 3) M-1: THE SUBMITTED MANUFACTURER SPECIFICATIONS FOR | | | THE POWER FLAME EQUIPMENT BURNERS INDICATE THEY ARE TO | | | BE ATTACHED IN SOME MANNER TO THE HOT LIQUOR AND BREW | | | HOUSE TANKS EITHER DIRECTLY OR VIA A HEAT EXCHANGER. | | | PLEASE PROVIDE A DETAIL SHOWING HOW THIS ATTACHMENT | | | WILL BE MADE, AND HOW BY-PRODUCTS OF COMBUSTION WILL BE | | | VENTED FROM THE TANKS OR THE EXHANGERS. THERE IS AN 8" | | | VENT INDICATED FOR THE BREW HOUSE (E) ON SHEET M-2 | | | HOWEVER NO INFORMATION ON VENT SIZNG, VENT TYPE, OR | | | VENT RUN WAS PROVIDED EITHER IN THE SPECS OR ON THE | | | PLAN AS PREVIOOUSLY REQUESTED. PLEASE NOTE THAT NO VENT | | | IS SHOWN FOR THE HOT LIQUOR TANK (D). PROVIDE A VENTING | | | DIAGRAM THAT PROVIDES THE REQUESTED MISSING INFORMATION | | | AND SUBMIT CUT SHEETS FOR THE VENT PIPE AND TERMINATION | | | CAP- SEE SECTIONS 502, 503, AND 504 FBC FG. GAS VENTS | | | SHALL TERMINATE IN ACCORDANCE WITH 2014 FBC-FUEL GAS | | | SEC. | | | | | | 4) REFER TO SECTION 619.1 FBC FG AND VERIFY THAT THE | | | POWER FLAME BURNERS CONFORM TO ANSI Z21.8. | | | | | | 5) THERE IS A DISCREPANCY IN THE PLANS AND THE SPECS ON | | | THE REQUIRED COMBUSTION AIR OPENING SIZING FOR THE | | | POWER FLAME BURNERS. THE PLANS INDICATE 1 SQ. INCH PER | | | 3000 BTU/H, HOWEVER THE SPECS INDICATE 1/2 SQ. INCH PER | | | 1000 BTU/H. PROVIDE THE CORRECT CALCULATION AND OPENING | | | SIZE PER THE MANUFACTURER'S SPECS. ADDITIONALLY PLEASE | | | REFER TO SECTION 304.6.2 FBC FG FOR THE REQUIRED | | | LOCATION OF THE OPENING TO COMMENCE WITHIN 12 INCHES OF | | | THE TOP OF THE ENCLOSURE. | | | | | | 6) IN ACCORDANCE WITH SECTIONS 107.1 AND 107.2 WPB ALL | | | EQUIPMENT AND APPLIANCE SUBMITTALS INCLUDING THE | | | CHILLER AND BREW TANKS SHALL BEAR THE SHOP DRAWING | | | STAMP OF THE EOR. | | | | | | 7) THE REGULATOR VENTS FOR THE POWER FLAME BURNERS | | | SHALL BE PIPED TO THE EXTERIOR PER 2014 FBC-FUEL GAS | | | SEC.410.3. SEE EXCEPTION FOR VENT-LIMITING DEVICE. | | | | | | 8) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE LINE | | | PRESSURE REGULATORS FOR THE POWER FLAME BURNERS. FBC | | | SEC. 107.2.1. | | | | | | 9) THERE IS ONLY ONE SHEET OF INFORMATION FOR TANK "E" | | | AND IT IS JUST A PRODUCT SHEET. SUBMIT ADDITIONAL | | | INFORMATION FOR THIS TANK.FBC 107.2.1. | | | | | | 10) SHOW THE DISTANCE FROM THE LINE PRESSURE REGULATORS | | | TO THE POWER FLAME BURNERS. | | | | | | 11) COMPLETE PIPING PLANS SHALL BE PROVIDED FOR ALL THE | | | TANKS. FBC 107.2.1. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-02-06 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-02-06 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-02-06 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2018-02-06 15:58:11 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. SHT. P-6 UNDER NATURAL GAS SYSTEM TWO SIZING TABLES | | | ARE LISTED SYSTEM IS UNDER SIZED IF TABLE 402.1(1) IS | | | USED BOTH TABLE ARE .5 LB SYSTEMS PLEASE CLARIFY. PER | | | WPB AMEND TO FBC 107.2.1 | | | | | | 2. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE AND | | | TERMINATION OF THE GAS VENTS PER FBC-2014 FUEL GAS CODE | | | SEC. 502 THRU 505. | | | | | | 3. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL | | | NEW GAS EQUIPMENT AND REGULATORS TO VERIFY COMPLIANCE | | | WITH STANDARDS NFPA 54, NFPA 58, AND FBC-2014 FUEL GAS | | | SEC. 402.2 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2019-02-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-02-06 |
Time |
07:44 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-01-30 |
Time |
15:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2019-01-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-01-30 |
Time |
07:39 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-01-25 |
Time |
18:23 |
Sent To |
|
|
| Notes |
| 2019-02-05 15:21:29 | ROUTED FROM ZONING TO PERMIT LIBRARIAN 2/5/2019 EL | | 2019-01-28 12:57:17 | 1/28 TO LIZ LEVESQUE | | | | | | | | 2019-01-25 18:24:06 | TO RM DESK | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2019-01-22 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-01-22 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-12-26 |
Time |
12:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2018-12-04 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-12-04 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-11-29 |
Time |
11:35 |
Sent To |
|
|
| Notes |
| 2019-01-22 15:00:36 | ROUTED FROM ZONING TO PERMIT LIBRARIAN 1/22/19 EL | | 2018-12-03 11:35:56 | C34 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-11-05 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-12-04 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-09-17 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2018-10-22 11:07:18 | ROUTED FROM ZONING TO LM 10/22/18 | | 2018-09-18 15:30:09 | C34 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-02-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-02-01 |
Time |
09:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-02-02 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2018-02-02 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-12-29 |
Time |
10:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2018-01-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-01-12 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-01-11 |
Time |
13:50 |
Sent To |
|
|
| Notes |
| 2018-01-12 13:55:55 | 01/12/2017 CALLED THE COUNTY IMPACT FEE OFFICE, NO | | | CHANGE OF OCCUPANCY NO INCREASE IN SQUARE FEET, NO | | | REVIEW REQUIRED. JWL |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2019-01-03 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-01-03 |
Time |
17:32 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-01-03 |
Time |
14:56 |
Sent To |
|
|
| Notes |
| 2019-01-03 17:33:29 | MECHANICAL PROVISOS. | | | 1/3/18 | | | | | | 1) COMMISSIONING OF THE BREWERY OR DISTILLERY SYSTEM | | | SHALL BE PERFORMED BY A THIRD PARTY AGENCY (FL. | | | LICENSED ENGINEER OR FL. LICENSED MECHANICAL | | | CONTRACTOR), OR BY THE MANUFACTURER OF THE SYSTEM, AND | | | A LETTER OR REPORT CERTIFYING THE INSTALLATION AND | | | FUNCTIONING OF THE SYSTEM SHALL BE PROVIDED. THE LETTER | | | AND/OR REPORT SHALL BE REVIEWED AND APPROVED BY THE FL. | | | LICENSED ENGINEER OR ARCHITECT IN RESPONSIBLE CHARGE OF | | | THE PROJECT. | | | | | | 2) TEST AND BALANCE REPORT FOR THE HVAC SYSTEMS DUE AT | | | FINAL MECHANICAL INSPECTION. | | | | | | 3) DEFERRED SUBMITTALS: | | | | | | A) WIND LOAD ENGINEERING FOR INSTALLATION OF THE | | | OUTDOOR CHILLER ON THE WALL MOUNTED PLATFORM. | | | | | | B) GAS VENT PIPING, VENT TERMINATION CAP, AND VENT | | | SUPPORT STRAPS. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2018-10-18 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-10-18 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-10-18 |
Time |
11:33 |
Sent To |
|
|
| Notes |
| 2018-10-18 16:33:30 | 3RD REVIEW FBC-2014 MECHANICAL | | | PERMIT #17121030 | | | 10/18/18 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | SOME OF THE COMMENTS FROM THE 1ST AND 2ND REVIEW HAVE | | | NOT BEEN ADDRESSED COMPLETELY AND STILL EXIST. I HAVE | | | REPRINTED THOSE COMMENTS BELOW, HOWEVER THE NUMERICAL | | | AND ALPHABETICAL ORDERS HAVE CHANGED. OTHER COMMENTS | | | THAT HAVE BEEN ADDRESSED HAVE BEEN DELETED. IN ORDER TO | | | EXPEDITE REVIEW OF THE RESUBMITTED PLANS, PLEASE | | | PROVIDE A RESPONSE NARRATIVE ADDRESSING EACH REMAINING | | | AND EACH NEW COMMENT. | | | | | | 1) THE MINIMUM VENTILATION CALCULATIONS FOR EXHAUST | | | SYSTEMS WERE NOT PROVIDED. THERE IS A NEW EXHAUST FAN | | | (EF-A) IN THE BREW TANK ROOM. PLEASE PROVIDE THE SIZING | | | CALCULATIONS AND THE SEQUENCE OF OPERATION FOR THE FAN. | | | | | | 2) THE REQUESTED CUT SHEET FOR THE NEW CHILLER WAS NOT | | | PROVIDED- PLEASE PROVIDE. | | | | | | 3) CUT SHEETS FOR THE BREW TANKS HAVE BEEN PROVIDED | | | EACH INDICATING THAT THEY ARE PRESSURE VESSELS AND | | | WOULD REQUIRE CERTIFICATION IN ACCORDANCE WITH THE ASME | | | BOILER AND PRESSURE VESSEL CODE. THE CUT SHEETS DO NOT | | | INDICATE THE TANKS HAVE THAT CERTIFICATION. PLEASE NOTE | | | THAT HOT TANKS D AND E DO NOT LIST THE WORKING | | | PRESSURES. | | | | | | 4) THE REQUESTED WIND LOAD ENGINEERING FOR THE CHILLER | | | WAS NOT PROVIDED. THE NEW NOTE ON S-2 INDICATES IT WILL | | | BE DONE UNDER A SEPARATE PERMIT WHICH IS NOT | | | ACCEPTABLE. PLEASE PROVIDE THE ENGINEERING OR REQUEST | | | IT TO BE A DEFERRED SUBMITTAL. | | | | | | 5) WORKING CLEARANCES AND ANCHORING DETAILS FOR THE | | | BREW TANKS NOT PROVIDED. | | | | | | 6) PROVIDE THE CLEARANCE DISTANCE FOR THE COMBUSTION | | | AIR OPENING TO THE PROPERTY LINE, AND SUBMIT MIAMI-DADE | | | NOA # 16-0201.08. PLEASE NOTE FL. PRODUCT APPROVAL | | | #12941.1 IS NOT VALID FOR 2017. | | | | | | 7) M-1: THE SUBMITTED MANUFACTURER SPECIFICATIONS FOR | | | THE POWER FLAME EQUIPMENT BURNERS INDICATE THEY ARE TO | | | BE ATTACHED IN SOME MANNER TO THE HOT LIQUOR AND BREW | | | HOUSE TANKS EITHER DIRECTLY OR VIA A HEAT EXCHANGER. | | | PLEASE PROVIDE A DETAIL SHOWING HOW THIS ATTACHMENT | | | WILL BE MADE, AND HOW BY-PRODUCTS OF COMBUSTION WILL BE | | | VENTED FROM THE TANKS OR THE EXHANGERS. THERE IS AN 8" | | | VENT INDICATED FOR THE BREW HOUSE (E) ON SHEET M-2 | | | HOWEVER NO INFORMATION ON VENT SIZNG, VENT TYPE, OR | | | VENT RUN WAS PROVIDED EITHER IN THE SPECS OR ON THE | | | PLAN AS PREVIOOUSLY REQUESTED. PLEASE NOTE THAT NO VENT | | | IS SHOWN FOR THE HOT LIQUOR TANK (D). PROVIDE A VENTING | | | DIAGRAM THAT PROVIDES THE REQUESTED MISSING INFORMATION | | | AND SUBMIT CUT SHEETS FOR THE VENT PIPE AND TERMINATION | | | CAP- SEE SECTIONS 502, 503, AND 504 FBC FG. | | | | | | 8) REFER TO SECTION 619.1 FBC FG AND VERIFY THAT THE | | | POWER FLAME BURNERS CONFORM TO ANSI Z21.8. | | | | | | 9) THERE IS A DISCREPANCY IN THE PLANS AND THE SPECS ON | | | THE REQUIRED COMBUSTION AIR OPENING SIZING FOR THE | | | POWER FLAME BURNERS. THE PLANS INDICATE 1 SQ. INCH PER | | | 3000 BTU/H, HOWEVER THE SPECS INDICATE 1/2 SQ. INCH PER | | | 1000 BTU/H. PROVIDE THE CORRECT CALCULATION AND OPENING | | | SIZE PER THE MANUFACTURER'S SPECS. ADDITIONALLY PLEASE | | | REFER TO SECTION 304.6.2 FBC FG FOR THE REQUIRED | | | LOCATION OF THE OPENING TO COMMENCE WITHIN 12 INCHES OF | | | THE TOP OF THE ENCLOSURE. | | | | | | 10) SHEET M-2: IT IS NOT CLEAR IF AIR FROM THE NEW | | | ENCLOSED BREWERY ROOM WILL BE RECIRCULATED TO THE | | | OCCUPIED DINING AREAS, HOWEVER BASED ON TABLE 403.3.1.1 | | | RECIRCULATION OF AIR FROM KITCHEN COOKING AREAS IS | | | PROHIBITIED, AND ALTHOUGH BREWERY AREAS ARE NOT LISTED | | | IN THE TABLE, THE KITCHEN OCCUPANCY WOULD BE THE MOST | | | SIMILAR- SEE SECTION 404.3.1.1 FOR AN EXPALNATION OF | | | THIS. | | | | | | 11) IN ACCORDANCE WITH SECTIONS 107.1 AND 107.2 WPB ALL | | | EQUIPMENT AND APPLIANCE SUBMITTALS INCLUDING THE | | | CHILLER AND BREW TANKS SHALL BEAR THE SHOP DRAWING | | | STAMP OF THE EOR. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2018-02-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-02-22 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-02-22 |
Time |
10:21 |
Sent To |
I |
|
| Notes |
| 2018-02-22 11:05:53 | 2ND REVIEW FBC-2014 MECHANICAL | | | PERMIT #17121030 | | | 2/22/18 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | | | | 1) MANY OF THE COMMENTS FROM THE 1ST REVIEW HAVE NOT | | | BEEN ADDRESSED AND STILL EXIST. I HAVE REPRINTED THOSE | | | COMMENTS BELOW. OTHER COMMENTS THAT HAVE BEEN ADDRESSED | | | HAVE BEEN DELETED. IN ORDER TO EXPEDITE REVIEW OF THE | | | RESUBMITTED PLANS, PLEASE PROVIDE A RESPONSE NARRATIVE | | | ADDRESSING EACH REMAINING AND EACH NEW COMMENT. PLEASE | | | PROVIDE: | | | | | | A) COMPLETE DUCT LAYOUT DRAWINGS THAT SHOW ALL NEW AND | | | RELOCATED DUCTS, DIFFUSERS, GRILLS, FIRE DAMPERS, DUCT | | | SMOKE DETECTORS ETC. (SECOND FLOOR PLAN HAS BEEN | | | SUBMITTED NO PLAN SUBMITTED FOR THE FIRST FLOOR). | | | | | | B) AIR DEVICE SCHEDULE | | | | | | C) DUCT HANGING, CONNECTION, AND SUPPORT DETAILS | | | | | | B) MINIMUM VENTILATION CALCULATIONS FOR ALL ROOMS AND | | | SPACES. (IT IS NOT CLEAR IF ADEQUATE O/A IS BEING | | | PROVIDED TO THE ALTERED ROOMS AND SPACES. | | | | | | D) MINIMUM VENTILATION CALCULATIONS FOR EXHAUST SYSTEMS | | | | | | G) EQUIPMENT SCHEDULES AND CUT SHEETS FOR THE BREW | | | TANKS, CHILLER, BOILER, FLUE VENTS, REFRIGERATION, | | | APPLIANCES ETC. | | | | | | I) WORKING CLEARANCES FOR EQUIPMENT AND ACCESS FOR | | | SERVICE AND REPLACEMENT. | | | | | | J) EQUIPMENT ANCHORING DETAILS | | | | | | K) WIND LOAD ENGINEERING FOR ALL EXTERIOR MOUNTED | | | APPLIANCES AND EQUIPMENT. | | | | | | L) OUTDOOR AIR INLET AND EXHAUST OUTLET LOCATIONS, | | | CLEARANCES AND OPENING PROTECTIONS. | | | | | | 2) ADVISORY: SEPARATE PERMITS ARE REQUIRED FOR KITCHEN | | | HOODS, FIRE SUPPRESSION, AND WALK-IN COOLERS AND | | | FREEZERS. PLEASE PLACE NOTES ON THE PLAN ACCORDINGLY. | | | | | | 3) SHEET M-1: SHOW THE LOCATION OF THE BOILER AND | | | SUBMIT MANUFACTURER'S SPECIFICATIONS PER SECTION 631 | | | FBC-14 FUEL GAS.THE NEW COMBUSTION AIR OPENING APPEARS | | | TO BE LOCATED BY THE BREW TANKS, THE BOILER IS NOT | | | SHOWN AND THERE IS NO EQUIPMENT SCHEDULE PROVIDED, | | | PLEASE NOTE THAT THE BOILER MAY BE REQUIRED TO BE IN A | | | FIRE-RATED ROOM PER TABLE 509 FBC-14 BUILDING. | | | | | | 4) M-1: PROVIDE A VENTING PLAN FOR THE BOILER | | | INDICATING THE TYPE AND SIZE OF FLUE PIPE, LENGTH OF | | | THE VENT RUN, TERMINATION HEIGHT ABOVE THE ROOF, AND | | | CLEARANCE DISTANCES TO GRAVITY AND MECHANICAL AIR | | | INTAKES- SECTION 503 FBC-14 FUEL GAS | | | | | | 5) M-1: SUBMIT MANUFACTURER SPECIFICATIONS FOR THE | | | POWER FLAME EQUIPMENT BURNERS AND INDICATE WHAT | | | FUNCTION THEY ARE PERFORMING IN THE BREWING PROCESS. | | | BECASUE THESE BURNERS ARE ATTACHED TO TANKS, PLEASE | | | PROVIDE THE WORKING PRESSURE OF THE TANKS, AND NOTE | | | THAT PRESSURE VESSELS EXCEEDING 15 PSI SHALL BE IN | | | ACCORDANCE WITH THE ASME BOILER AND PRESURE VESSEL | | | CODE- | | | | | | SECTION 1003.1 FBC-14 MECHANICAL. | | | | | | 6) M-1: INDICATE HOW COMBUSTION AIR IS BEING PROVIDED | | | TO THE POWER FLAME UNITS AND PROVIDE CALCULATIONS PER | | | SECTION 304 FBC-14 FUEL GAS. | | | | | | 7) M-1: PROVIDE A VENTING PLAN FOR THE EQUIPMENT | | | BURNERS INDICATING THE TYPE AND SIZE OF VENT PIPE, | | | LENGTH OF THE VENT RUN, TERMINATION HEIGHT ABOVE THE | | | ROOF OR FROM GRADE, AND CLEARANCE DISTANCES TO GRAVITY | | | AND MECHANICAL AIR INTAKES- SECTION 503 FBC-14 FUEL | | | GAS. | | | | | | 8) M-1: PROVIDE A FLORIDA PRODUCT APPROVAL OR | | | MIAMI-DADE NOA FOR THE NEW BOILER COMBUSTION AIR | | | OPENING- RULE 9N-03 FLORIDA ADMINISTRATIVE CODE. REFER | | | TO SECTIIO N 304.6.2 AND PROVIDE A NOTE OR ELEVATION | | | DRAWING TO INDICATE THE LOCATION OF THE COMBUSTION AIR | | | OPENING. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-01-29 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-01-29 |
Time |
08:11 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-01-29 |
Time |
07:22 |
Sent To |
|
|
| Notes |
| 2018-01-29 08:36:31 | 1ST REVIEW FBC-2014 MECHANICAL & EXISTING BUILDING | | | CODES, WPB AMENDMENTS TO THE FBC. | | | PERMIT #17121030 | | | 1/29/18 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET CS: THE ARCHITECT OF RECORD HAS PROVIDED | | | CONFUSING INFORMATION ON THE PLANS REGARDING THE | | | PERMITTING OF THE MECHANICAL WORK ON THE PROJECT. THE | | | ARCHITECT STATES THAT MEP SHEETS ARE ATTACHED BUT THEN | | | HAS A NOTE STATING "UNDER SEPARATE PERMIT". THAT NOTE | | | APPEARS TO BE IN CONFLICT WITH THE SCOPE OF WORK NOTES | | | WHICH INDICATE NEW DUCTWORK AND RELOCATION OF | | | | | | DUCTWORK. CURRENTLY NO MECHANICAL PLANS OR | | | SPECIFICATIONS HAVE BEEN SUBMITTED FOR REVIEW. | | | | | | REFER TO SECTION 107.3.5.1.4 AND REVIEW THE MINIMUM | | | MECHANICAL PLAN REVIEW CRITERIA REQUIRED FOR | | | PERMITTING. PERTAINING TO THE PROPOSED PROJECT PLEASE | | | PROVIDE COMPLETE MECHANICAL PLANS UNDER THIS PERMIT, OR | | | SEPARATE PERMIT, INCLUDING BUT NOT LIMITED TO: | | | | | | A) DUCT LAYOUT DRAWINGS THAT SHOW ALL NEW AND RELOCATED | | | DUCTS, DIFFUSERS, GRILLS, FIRE DAMPERS, DUCT SMOKE | | | DETECTORS ETC. | | | | | | B) AIR DEVICE SCHEDULE | | | | | | C) DUCT HANGING, CONNECTION, AND SUPPORT DETAILS | | | | | | B) MINIMUM VENTILATION CALCULATIONS FOR ALL ROOMS AND | | | SPACES | | | | | | D) MINIMUM VENTILATION CALCULATIONS FOR EXHAUST SYSTEMS | | | | | | E) COOLING AND HEATING LOAD CALCULATIONS FOR ALL NEW AC | | | SYSTEMS | | | | | | F) COMBUSTION AIR CALCULATIONS FOR ALL GAS-FIRED | | | EQUIPMENT | | | | | | G) EQUIPMENT SCHEDULES AND CUT SHEETS FOR THE BREW | | | TANKS, CHILLER, BOILER, FLUE VENTS, REFRIGERATION, | | | APPLIANCES ETC. | | | | | | H) CHILLER WATER AND STEAM PIPING LAYOUT PLANS AND | | | SPECIFICATIONS. | | | | | | I) WORKING CLEARANCES FOR EQUIPMENT AND ACCESS FOR | | | SERVICE AND REPLACEMENT. | | | | | | J) EQUIPMENT ANCHORING DETAILS | | | | | | K) WIND LOAD ENGINEERING FOR ALL EXTERIOR MOUNTED | | | APPLIANCES AND EQUIPMENT. | | | | | | L) OUTDOOR AIR INLET AND EXHAUST OUTLET LOCATIONS, | | | CLEARANCES AND OPENING PROTECTIONS. | | | | | | 2) ADVISORY: SEPARATE PERMITS ARE REQUIRED FOR KITCHEN | | | HOODS, FIRE SUPPRESSION, AND WALK-IN COOLERS AND | | | FREEZERS. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2019-01-16 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2019-01-16 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2019-01-10 |
Time |
12:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2018-10-29 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-10-29 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-10-29 |
Time |
09:08 |
Sent To |
|
|
| Notes |
| 2018-10-29 10:39:15 | 1) THE CHANNEL DRAIN SHALL BE EQUIPPED WITH A TRAP | | | PRIMER. 2014 FBC-PLUMBING SEC.1002.4. | | | 2) SHT. A7.1 - ELEVATION "B" - THE TOILET PAPER | | | DISPENSER SHALL BE LOCATED 7-9 INCHES TO THE CENTERLINE | | | OF THE DISPENSER. 2014 FBC-ACCESS. SEC.604.7. | | | 3) SHT. A7.1 - ELEVATIONS A & B - THE HEIGHT OF THE | | | GRAB BARS SHALL BE MEASURED TO THE TOP OF THE GRIPPING | | | SURFACE. 2014 FBC-ACCESS. SEC. 609.4. | | | 4) THE MIRROR SHALL BE INSTALLED WITH THE BOTTOM EDGE | | | OF THE REFLECTING SURFACE 40 INCHES MAXIMUM ABOVE THE | | | FINISH FLOOR OR GROUND. 2014 FBC-ACCESS SEC. 603.3. | | | 5) SHT. P.5 - HOW IS THE HAND SINK ON THE 2ND FLOOR | | | BEING VENTED? THE SANITARY RISER SHOWS IT AS AN "S" | | | TRAP. CLARIFY. | | | 6) THE DRAIN FOR THE HAND SINK AND FLOOR SINK ON THE | | | 2ND FLOOR AND THE SINK ON THE FIRST FLOOR MUST CONNECT | | | TO THE 1ST FLOOR HORIZONTAL DRAIN DOWNSTREAM OF THE | | | BATHROOM GROUP. 2014 FBC-PLUMBING SEC.912.1. | | | 7) REMOVE ALL THE OLD PLUMBING SHEETS FROM THE PLAN | | | SETS. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-02-06 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-02-06 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-02-02 |
Time |
11:11 |
Sent To |
|
|
| Notes |
| 2018-02-06 15:50:38 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. THE FIXTURES IN THE NEW BAR AREA SHOULD NOT BE | | | CONNECTED TO THE GREASE WASTE UNLESS FOOD PREP OR | | | COOKING IS BEING DONE IN THIS AREA. FIXTURES THAT DON'T | | | PRODUCE GREASY WASTE SHALL NOT DISCHARGE TO GREASE | | | INTERCEPTOR, OR PROVIDE SIZING CALCULATIONS WITH NEW | | | GREASE WASTE LOAD. PER FBC PL 1003.3.1 | | | | | | 2. THE NEW HAND SINK ON SECOND LEVEL SHALL BE PROVIDED | | | WITH HOT WATER. PER FBC PL 607.1 | | | | | | 3. THE FLOOR DRAIN ON THE SECOND LEVEL IS SHOWN AS 3" | | | ON THE ISOMETRIC DRAWING THE BRANCH DRAIN CONNECTED TO | | | IT IS SHOWN AS 2" A PIPE CAN NOT DECREASE IN SIZE IN | | | THE DIRECTION OF FLOW.PER FBC PL 704.2 | | | | | | 4. A TRAP PRIMER IS REQUIRED ON THE FLOOR DRAINS . PER | | | FBC PL 1002.4 | | | | | | 5. PLEASE PROVIDE A RISER DIAGRAM FOR ALL PROCESS | | | PIPING FOR BREWING. PER WPB AMEND TO FBC | | | 107.3.5.1.3(13) | | | | | | 6. PROVIDE MANUFACTURE SPECIFICATIONS FOR THE BREWING | | | EQUIPMENT. PER WPB AMEND TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
1 |
Status |
N |
Date |
2018-11-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-11-05 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2019-02-05 |
|
|
Cont ID |
|
| Sent By |
elevesqu |
Date |
2019-02-05 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
2019-02-05 |
Time |
15:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
2019-01-28 |
|
|
Cont ID |
|
| Sent By |
elevesqu |
Date |
2019-01-28 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
2019-01-28 |
Time |
14:32 |
Sent To |
B |
|
| Notes |
| 2019-01-28 14:36:43 | IF RAMP IS NOT PROPOSED, IT NEEDS TO BE REMOVED FROM | | | LIFE SAFETY PLANS SHEET A1.0 AS THIS IS THE SHEET | | | REVIEWED BY FIRE DEPARTMENT AND BUILDING DEPARTMENT | | | | | | IF RAMP IS NOT PROPOSED, IT NEEDS TO BE REMOVED FROM | | | ELEVATIONS SHEET A6.0 | | | | | | PLEASE ENSURE ALL OTHER PLANS ARE CONSISTENT. | | | | | | LIZ LEVESQUE, URBAN DESIGN PLANNER | | | 561 422 1426 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2019-01-22 |
|
|
Cont ID |
|
| Sent By |
elevesqu |
Date |
2019-01-22 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
2019-01-22 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2019-01-22 14:59:32 | RAMP TO DOOR ENTRANCE CANNOT BE LOCATED IN THE ROW- | | | PLEASE LOCATE INSIDE. | | | | | | PLEASE MAKE NOTE: NEW DOORS TO MATCH MULLION PATTERN OF | | | EXISTING ADJACENT DOORS TO EXTENT POSSIBLE. | | | | | | LIZ LEVESQUE, URBAN DESIGN PLANNER | | | 561 822 1426 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-10-22 |
|
|
Cont ID |
|
| Sent By |
elevesqu |
Date |
2018-10-19 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
2018-10-19 |
Time |
09:51 |
Sent To |
|
|
| Notes |
| 2018-10-22 11:06:39 | PROVISO: OUTDOOR SEATING TO BE REVIEWED THROUGH | | | SEPARATE PERMIT. | | | | | | LIZ LEVESQUE, URBAN DESIGN PLANNER | | | 561 822 1426 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-02-08 |
|
|
Cont ID |
|
| Sent By |
AA |
Date |
2018-02-08 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2018-02-08 |
Time |
13:44 |
Sent To |
|
|
| Notes |
| 2018-02-08 13:53:17 | 1. NEW WALL ON NARCISSUS AVE SHALL NOT HAVE A FOOT REST | | | ATTACHED TO IT (EXTERIOR). | | | 2. PACKAGE SALES ARE NOT PERMITTED AT THIS LOCATION. |
|
|
|