| 2018-06-16 14:32:54 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED | | | SETS OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | | NEED "VOID", RENDERING THEM NOT USABLE. | | | | | | 2. SEE PLUMBING REVIEW; ACCESSIBILITY COMMENTS ARE | | | APPLICABLE FOR BUILDING REVIEW. PLEASE REVISE PLAN | | | ACCORDINGLY. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-03-23 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-03-23 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-03-23 |
Time |
08:22 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-03-02 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-03-02 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-03-02 |
Time |
07:54 |
Sent To |
|
|
| Notes |
| 2018-03-02 09:16:00 | ****PLAN REVIEW COMMENTS**** | | | | | | ART LANGE BUILDING PLANS EXAMINER | | | | | | DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FL 33402 | | | | | | 561-805-6718 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2014 5H EDITION W/2010 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | SECOND REVIEW: | | | | | | 1. PRODUCT APPROVALS. | | | | | | A) TWO DIFFERENT PRODUCT APPROVALS WERE SUBMITTED FOR | | | THE ONE OVERHEAD DOOR OPENING. NOTE, THE OPENING IS 15 | | | FT.. THE PRODUCT APPROVALS SUBMITTED ARE FOR A WIDTH OF | | | 12 FT 2 INCHES. | | | | | | B) A CASEMENT WINDOW PRODUCT APPROVAL WAS RECEIVED. | | | PROVIDE ADDITIONAL PRODUCT APPROVALS FOR MULLIONS AND | | | FIXED WINDOWS. | | | | | | C) PROVIDE PRODUCT APPROVAL FOR SINGLE ENTRY DOOR. | | | | | | D) ROOFING HAS BEEN REMOVED FROM THE SCOPE OF WORK PER | | | ARCHITECTS REQUEST. FBC 107.1 SUBMITTAL DOCUMENTS | | | | | | 2. PAGE S300 MISSING FROM ONE SET. FBC 107.1 SUBMITTAL | | | DOCUMENTS | | | | | | | | | WHEN RESUBMITTING, PLEASE COMPLETE A RESUBMITTAL FORM: | | | | | | HTTP://WPB.ORG/DEVELOPMENT/WPCONTENT/UPLOADS/SITES/33/2 | | | 013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | THIS FORM IS ALSO AVAILABLE AT THE BUILDING DIVISION. | | | WHEN RESUBMITTING, SWAP OUT SHEETS WHICH HAVE CHANGED | | | SO THAT THERE ARE TWO COMPLETE, COLLATED SETS OF PLANS | | | READY FOR PERMIT ISSUANCE. OLD SHEETS ARE TO BE | | | RETAINED IN THE PERMIT APPLICATION PACKAGE (SEPARATE | | | FROM THE PERMIT SETS) AND MARKED *OLD SHEETS* OR | | | *VOID*. PLEASE KEEP BOTH SETS OF OLD VOIDED SHEETS IN | | | THE PERMIT PACKAGE. | | | | | | A RESPONSE LETTER INDICATING HOW EACH ITEM WAS | | | ADDRESSED WILL HELP TO EXPEDITE PLAN REVIEW. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-01-02 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-01-02 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-01-02 |
Time |
14:57 |
Sent To |
|
|
| Notes |
| 2018-01-02 16:08:03 | ****PLAN REVIEW COMMENTS**** | | | | | | ART LANGE BUILDING PLANS EXAMINER | | | | | | DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FL 33402 | | | | | | 561-805-6718 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2014 5TH EDITION W/2010 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | | | | 1. PROVIDE PRODUCT APPROVALS FOR THE FOLLOWING. | | | EXTERIOR DOORS, OVERHEAD DOORS, WINDOWS AND ROOFING. | | | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | ALTERNATIVELY YOU CAN LIST THESE ON THE COVER SHEET AND | | | PROVIDE THEM LATER AS DEFERRED SUBMITTALS. | | | | | | FBC 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF | | | THIS SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | | | | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS | | | FOR REVIEW BY THE BUILDING OFFICIAL. | | | | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | | | | 2. NOTE: ONE SET OF PLANS HAS TWO SETS OF S PAGES. | | | | | | | | | WHEN RESUBMITTING, PLEASE COMPLETE A RESUBMITTAL FORM: | | | | | | HTTP://WPB.ORG/DEVELOPMENT/WPCONTENT/UPLOADS/SITES/33/2 | | | 013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | THIS FORM IS ALSO AVAILABLE AT THE BUILDING DIVISION. | | | WHEN RESUBMITTING, SWAP OUT SHEETS WHICH HAVE CHANGED | | | SO THAT THERE ARE TWO COMPLETE, COLLATED SETS OF PLANS | | | READY FOR PERMIT ISSUANCE. OLD SHEETS ARE TO BE | | | RETAINED IN THE PERMIT APPLICATION PACKAGE (SEPARATE | | | FROM THE PERMIT SETS) AND MARKED *OLD SHEETS* OR | | | *VOID*. PLEASE KEEP BOTH SETS OF OLD VOIDED SHEETS IN | | | THE PERMIT PACKAGE. | | | | | | A RESPONSE LETTER INDICATING HOW EACH ITEM WAS | | | ADDRESSED WILL HELP TO EXPEDITE PLAN REVIEW. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2018-08-14 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-08-14 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-08-14 |
Time |
07:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2018-06-12 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2018-06-12 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2018-06-12 |
Time |
09:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-03-16 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-03-16 |
Time |
07:53 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-03-16 |
Time |
07:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-01-11 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-01-11 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-01-11 |
Time |
11:33 |
Sent To |
|
|
| Notes |
| 2018-01-11 11:33:53 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. A DISCREPANCY EXIST BETWEEN PANEL SCHEDULE AND | | | ELECTRICAL PLAN IN REFERENCE TO THE FUSE SIZE OF | | | DISCONNECT. THE PLAN STATES THAT THE FUSE IS 125 AMP | | | AND THE PANEL SCHEDULE STATES THAT THE FUSE IS 150 AMP. | | | PROVIDE RISER DIAGRAM SHOWING EXISTING WIRE AND FUSE | | | SIZE TO HANDLE LOAD STATED IN PANEL SCHEDULE OF | | | APPROXIMATELY 142 AMPS. NEC 215.2, 215.5, 240.4; FBC | | | 17.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-06-01 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-06-01 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-05-31 |
Time |
16:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2018-01-22 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-01-22 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-01-22 |
Time |
14:36 |
Sent To |
|
|
| Notes |
| 2018-01-22 14:37:36 | GAS PLAN REVIEW | | | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | | THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE | | | REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK. | | | PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT | | | SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE | | | SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE | | | FBC-R, SEC. G2404.3. | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL | | | GAS SEC. 301.3. | | | | | | A SEPARATE PERMIT AND PLANS IS REQUIRED FOR THE GAS | | | INSTALLATION OR MODIFICATION OF SYSTEM. | | | | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2018-08-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-25 |
Time |
17:40 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-07-24 |
Time |
15:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2018-06-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-06-16 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-05-25 |
Time |
10:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-04-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-04-02 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-03-20 |
Time |
15:51 |
Sent To |
|
|
| Notes |
| 2018-03-22 15:51:19 | RESUB ROUTED TO ACLANGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-03-17 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-03-17 |
Time |
07:13 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-02-26 |
Time |
15:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-01-30 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-01-30 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2017-12-27 |
Time |
09:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2018-11-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-11-15 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-11-15 |
Time |
15:38 |
Sent To |
|
|
| Notes |
| 2018-11-15 15:39:24 | MU-2018-030532 | | | $1,565.28 PAID | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2018-08-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-25 |
Time |
17:47 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-08-25 |
Time |
17:47 |
Sent To |
|
|
| Notes |
| 2018-08-25 17:47:41 | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | | RETURNED STAMPED AND WITH A COPY OF THE RECEIPT AS | | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2018-06-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-06-07 |
Time |
17:22 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-06-07 |
Time |
16:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2018-04-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-04-02 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-04-02 |
Time |
10:27 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2018-03-08 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-03-08 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-03-08 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2018-03-08 16:06:13 | 2ND REVIEW FBC-2014 MECHANICAL | | | PERMIT #17120971 | | | 3/8/18 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) REVISE THE ARCHITECTURAL PLANS TO SHOW THE REQUIRED | | | WALL AND ROOF INSULATIONS THAT ARE SHOWN ON THE | | | MECHANICAL PLANS AND IN THE ENERGY CALCULATIONS. THE | | | ARCHITECT OF RECORD SHALL REVIEW THE ENERGYGAUGE | | | COMPLIANCE SUBMITTAL, MAKE ANY REQUIRED CHANGES TO THE | | | PLANS, AND CERTIFY THE PROJECT BY PROVIDING HIS/HER | | | SIGNATURE ON PAGE 3 OF THE SUBMITTAL- SECTION | | | C103.1.1.2 FBC-14 | | | | | | ENERGY CONSERVATION. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-01-11 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-01-11 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-01-11 |
Time |
09:05 |
Sent To |
|
|
| Notes |
| 2018-01-11 10:30:48 | 1ST REVIEW FBC-2014 BUILDING | | | PERMIT #17120971 | | | 1/11/18 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) ENGINEERING FOR INSTALLATION OF THE RTU IS | | | INCOMPLETE: | | | | | | A) PROVIDE STRUCTURAL DETAILS FOR THE NEW ROOF OPENING. | | | | | | B) PROVIDE THE WIND LOAD DESIGN CRITERIA AS OUTLINED IN | | | SECTION 1609 FBC-14 BUILDING. | | | | | | C) PROVIDE THE NOA FOR THE THYBAR CURB WITH SHOP | | | DRAWING STAMP BY THE EOR. | | | | | | D) PROVIDE COMPLETE ATTACHMENT DETAILS- CURB TO ROOF, | | | RTU TO CURB. | | | | | | 2) CLARIFY HOW ACCESS TO THE NEW RTU WILL BE PROVIDED. | | | WHAT IS THE HEIGHT OF THE ROOF SURFACE FROM GRADE- SEE | | | SECTION 306.5. | | | | | | 3) PLEASE CLARIFY WHY AIR CONDITIONING IS BEING | | | PROVIDED FOR A WAREHOUSE. IDENTIFY WHAT PURPOSE THE | | | SPACE WILL SEVE AND WHAT MATERIALS WILL BE STORED | | | THERE. | | | | | | 4) ENERGYGAUGE COMPLIANCE FORM AND INPUT DATA REPORT: | | | | | | A) NO DATA PROVIDED FOR THE OVERHEAD DOORS. | | | | | | B) NO DATA PROVIDED FOR THE NORTH AND WEST WALLS | | | ENCLOSING THE 3100 SF WAREHOUSE BUILDING. | | | | | | C) SHOW ON THE PLANS WHERE ALL THE INSULATIONS THAT ARE | | | LISTED ON PAGE 5 OF THE INPUT DATA REPORT ARE TO BE | | | INSTALLED OR ARE EXISTING. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | BUILDING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2018-08-23 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-08-23 |
Time |
17:43 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-08-23 |
Time |
16:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2018-06-15 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-06-15 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-06-15 |
Time |
10:49 |
Sent To |
|
|
| Notes |
| 2018-06-15 14:44:34 | 3RD REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. SHT. A8.1 DETAIL #1 FOR THE ACCESSIBLE BATHROOMS THE | | | CLEAR FLOOR SPACE FOR THE TOILET SHALL EXTEND FROM THE | | | SIDE WALL OF THE TOILET 60" ACROSS TO THE LAVATORY IT | | | APPEARS ON THE DETAIL THAT THE CLEAR FLOOR SPACE IS | | | TURNED 180* AND THERE IS ONLY 56" WHERE THERE SHOULD BE | | | 60" AND 60" WHERE THERE SHOULD BE 56" PLEASE CLARIFY | | | PER FBC ACC 604.3.1 SIZE. CLEARANCE AROUND A WATER | | | CLOSET SHALL BE 60 INCHES MINIMUM MEASURED | | | PERPENDICULAR FROM THE SIDE WALL AND 56 INCHES MINIMUM | | | MEASURED PERPENDICULAR FROM THE REAR WALL. | | | | | | 2. SHT. A8.1 DETAIL #1 PLEASE SHOW THE 30" X 48" CLEAR | | | FLOOR SPACE FOR THE LAVATORY. PER FBC ACC 606.2 CLEAR | | | FLOOR SPACE. A CLEAR FLOOR SPACE COMPLYING WITH 305, | | | POSITIONED FOR A FORWARD APPROACH, AND KNEE AND TOE | | | CLEARANCE COMPLYING WITH 306 SHALL BE PROVIDED. | | | | | | 3. THE DOOR SHALL NOT SWING INTO THE BATHROOM UNLESS A | | | 30"X48" CLEAR FLOOR SPACE CLEAR OF THE ARC OF THE DOOR. | | | PER FBC ACC 603.2.3 | | | | | | 4. SHOW COMPLIANCE FOR FBC ACC 604.7 DISPENSERS. TOILET | | | PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND SHALL BE 7 | | | INCHES MINIMUM AND 9 INCHES MAXIMUM IN FRONT OF THE | | | WATER CLOSET MEASURED TO THE CENTERLINE OF THE | | | DISPENSER. THE OUTLET OF THE DISPENSER SHALL BE 15 | | | INCHES MINIMUM AND 48 INCHES MAXIMUM ABOVE THE FINISH | | | FLOOR | | | | | | 5. THE MIRROR SHALL BE 40" TO THE REFLECTIVE SURFACE | | | NOT TO THE FRAME. PER FBC ACC 603.3 | | | | | | 6.SHT. A8.1 PLEASE REVISE DETAIL TO SHOW COMPLIANCE | | | WITH FBC ACC 604.5.2 REAR WALL. THE REAR WALL GRAB BAR | | | SHALL BE 36 INCHES LONG MINIMUM AND EXTEND FROM THE | | | CENTERLINE OF THE WATER CLOSET 12 INCHES MINIMUM ON ONE | | | SIDE AND 24 INCHES MINIMUM ON THE OTHER SIDE. | | | | | | 7. THE TOILET IN THE BACK OF THE WARE HOUSE AND THE ONE | | | NEXT TO THE BREAK BOTH APPEAR TO HAVE BEEN ENLARGED IF | | | SO THEY BOTH SHALL COMPLY WITH FBC ACC 213, 603, 604, | | | 606 | | | | | | 8. THE SINKS IN THE BREAK ROOM AND NEXT TO STORAGE | | | ROOMS 102- 103 SHALL COMPLY WITH FBC ACC 603.2, 606.3 | | | | | | 9. PROVIDE GPM FOR THE 3" ROOF DRAIN RISER. PER WPB | | | AMEND TO FBC 107.2.1 | | | | | | 10. IF THE HOT WATER RUN FROM THE WATER HEATER #1 TO | | | BATHROOM 107 IS OVER 50' A RECIRCULATION SYSTEM WILL BE | | | REQUIRED IT LOOKS CLOSE IT WILL BE MEASURED IN THE | | | FIELD. PER FBC PL 607.2 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2018-03-17 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-03-17 |
Time |
07:05 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-03-17 |
Time |
07:05 |
Sent To |
|
|
| Notes |
| 2018-03-17 07:09:27 | NO PLUMBING WORK UNDER THIS SCOPE OF WORK PER RESPONSE | | | LETTER FROM ARCHITECT. | | | | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-01-22 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-01-22 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-01-22 |
Time |
14:37 |
Sent To |
|
|
| Notes |
| 2018-01-22 14:44:36 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. PROVIDE DETAILED SCOPED OF PLUMBING WORK BEING DONE. | | | PER WPB AMEND TO FBC 107.2.1 | | | | | | 2. IT APPEARS A BATHROOM IS BEING ELIMINATED PROVIDE A | | | PLUMBING FIXTURE COUNT CALCULATION TO SHOW THE REQUIRED | | | PLUMBING FIXTURES ARE PROVIDED FOR THE OCCUPANT LOAD. | | | PER FBC PL 403.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2018-03-17 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-03-17 |
Time |
07:13 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-03-17 |
Time |
07:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2018-06-14 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2018-06-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2018-06-14 |
Time |
09:56 |
Sent To |
|
|
| Notes |
| 2018-06-14 15:32:11 | ZONING APPROVED WITH THE FOLLOWING PROVISOS: | | | | | | 1.) THE VALUE OF CONSTRUCTION FOR THIS PERMIT | | | ($775,000) EXCEEDS 50% OF THE VALUE OF THE EXISTING | | | STRUCTURE ($576,995). THEREFORE, THE LANDSCAPING ON THE | | | PROPERTY SHALL BE IMPROVED/UPGRADED ON THE PROPERTY TO | | | MEET THE CURRENT LANDSCAPE REQUIREMENTS OF THE CITY AS | | | BEST AS POSSIBLE. A LANDSCAPE PERMIT SHALL BE REQUIRED | | | PRIOR TO THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY. | | | | | | 2.) AN EXPANSION OF THE USE TO THE BUILDING LOCATED AT | | | 424 PALM STREET WILL BE REQUIRED A UNITY OF TITLE/UNITY | | | OF CONTROL. PLEASE CONTACT THE ENGINEERING SERVICES | | | DEPARTMENT FOR MORE INFORMATION @ (561) 494-1040. | | | | | | 3.) SEPARATE PERMITS REQUIRED FOR: FENCE/WALL, PARKING | | | AREA, LANDSCAPE AND IRRIGATION. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-03-01 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2018-03-01 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2018-03-01 |
Time |
|
Sent To |
|
|
| Notes |
| 2018-03-01 15:08:35 | ZONING APPROVED WITH THE FOLLOWING PROVISOS: | | | | | | 1.) THE VALUE OF CONSTRUCTION FOR THIS PERMIT IS | | | $225,000. ANY FURTHER IMPROVEMENTS TO THE BUILDING MAY | | | TRIGGER THE 50% LANDSCAPE IMPROVEMENT REQUIREMENT. | | | ASSESS IMPROVEMENT VALUE PER PAPA (2017) IS $576,995. | | | | | | 2.) AN EXPANSION OF THE USE TO THE BUILDING LOCATED AT | | | 424 PALM STREET WILL REQUIRE A UNITY OF TITLE/UNITY OF | | | CONTROL. PLEASE CONTACT THE ENGINEERING SERVICES | | | DEPARTMENT FOR MORE INFORMATION @ (561) 494-1040. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-01-29 |
|
|
Cont ID |
|
| Sent By |
LL |
Date |
2018-01-29 |
Time |
|
Rev Time |
|
| Received By |
llouie |
Date |
2018-01-24 |
Time |
|
Sent To |
|
|
| Notes |
| 2018-01-29 17:33:46 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) ELEVATIONS INCORRECT. PLEASE ADDRESS. | | | | | | 2.) EAST ELEVATION ON SHEET A3.1 SEEMS TO BE THE SOUTH | | | ELEVATION. PLEASE ADDRESS. | | | | | | NOTES: | | | | | | * REVISIONS MAY RESULT IN ADDITIONAL COMMENTS. | | | | | | * PROPOSED USE: RETAIL BUSINESS AND WAREHOUSING HAVING | | | MODERATE EXTERNAL IMPACTS. | | | | | | * THE VALUE OF CONSTRUCTION FOR THIS PERMIT IS | | | $225,000. ANY FURTHER IMPROVEMENTS TO THE BUILDING MAY | | | TRIGGER THE 50% LANDSCAPE IMPROVEMENT REQUIREMENT. | | | ASSESSED IMPROVEMENT VALUE PER PAPA (2017) IS $576,995. | | | | | | * AN EXPANSION OF THE USE TO THE BUILDING LOCATED AT | | | 424 PALM STREET WILL REQUIRE A UNITY OF TITLE/UNITY OF | | | CONTROL. PLEASE CONTACT THE ENGINEERING SERVICES | | | DEPARTMENT FOR MORE INFORMATION @ (561) 494-1040. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | | | | * ZONE: GC | | | |
|
|