| 2018-01-10 13:24:31 | RESIDENTIAL (R3) CHANGE OF OCCUPANCY FROM CARPORT TO |
| | LIVABLE AREA, BUILDING REVIEW COMMENTS. |
| | CODE: FBC 5TH EDITION (2014). |
| | |
| | 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH |
| | COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT. |
| | BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID |
| | RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF |
| | THE UNIFIED LAND DEVELOPMENT CODE. |
| | |
| | 2- THE EGRESS WINDOW "B" DOESN'T COMPLY WITH THE |
| | MINIMUM CLEAR HEIGHT AND TOTAL CLEAR OPENING AS |
| | REQUIRED BY SEC. R310.1.2 AND R310.1.1 FBC-RESIDENTIAL, |
| | 5TH EDITION (2014). REVISE SIZE OF WINDOW AS REQUIRED |
| | OR PROVIDE MANUFACTURER'S SPECIFICATIONS SHOWING THAT |
| | THE PROPOSED SIZE WILL COMPLY WITH ALL THE EGRESS |
| | REQUIREMENTS. NOTE: NORMAL WINDOW OPERATION IS REQUIRED |
| | TO ACHIEVE THE EGRESS REQUIREMENTS. ADDITIONAL STEPS OR |
| | KNOWLEDGE TO OPERATE THE WINDOW IS NOT ALLOWED. |
| | |
| | 3- CEILING INSULATION R-VALUE SPECIFIED ON THE TYPICAL |
| | WALL SECTION "A" ON SHEET A-1 DOESN'T MATCH R-VALUE |
| | REQUIRED ON THE ENERGY CALCULATIONS SUBMITTED. REVISE |
| | AS REQUIRED. SEC. R103.2 FBC-ENERGY CONSERVATION, 5TH |
| | EDITION (2014). |
| | |
| | 4- SHEET SP-1: THE NOTE BELOW THE SCOPE OF WORK STATES |
| | THAT THE LEVEL OF ALTERATION SHALL COMPLY WITH SEC. 404 |
| | AND ALTERATION LEVEL 2 OF THE EXISTING BUILDING CODE. |
| | THE SCOPE OF WORK IS NOT ALTERATION LEVEL 2. THIS IS A |
| | PARTIAL CHANGE OF CHANGE OF OCCUPANCY FROM GROUP U TO |
| | GROUP R. REVISE NOTE AS REQUIRED. SEC. 506 FBC-EXISTING |
| | BUILDING, 5TH EDITION (2014). |
| | |
| | 5- SHEET A-4: REVISE THE STRUCTURAL NOTE #1. THE |
| | BUILDING CODE IN EFFECT AT THE TIME OF THIS PERMIT |
| | APPLICATION IS THE FBC 5TH EDITION (2014) NOT 2010. AND |
| | THE ACI 318 AND ACI 530 REFERENCED EDITION IS THE 11 |
| | EDITION NOT THE 08 EDITION. REVISE AS REQUIRED. SEE |
| | CHAPTER 46 FC-RESIDENTIAL AND REVISE AS REQUIRED. |
| | |
| | 6- PROVIDE CURRENT FLORIDA PRODUCT APPROVAL FOR THE |
| | SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON PLANS. ICC |
| | EVALUATION REPORT ESR-2613 SUBMITTED EXPIRED ON |
| | 06/2016. PROVIDE CURRENT FLORIDA PRODUCT APPROVAL AS |
| | REQUIRED BY FAC 61G20-3.001. |
| | |
| | NOTE: |
| | FOR INFORMATION PURPOSES ONLY. COPY OF THE SURVEY |
| | SUBMITTED STATES THAT THIS PROPERTY IS LOCATED IN FLOOD |
| | ZONE "C". THIS IS INCORRECT. THIS PROPERTY WAS |
| | CONSIDERED AS FLOOD ZONE "B" BEFORE THE NEW FLOOD MAPS |
| | WENT INTO EFFECT. AFTER THE NEW FLOOD MAPS WENT INTO |
| | EFFECT ON 10/05/17 THIS BUILDING IS LOCATED BETWEEN 2 |
| | DIFFERENT FLOOD ZONES: X500 AND AE. THEREFORE, TAKE |
| | THIS INTO CONSIDERATION FOR FUTURE WORK. |
| | |
| | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH |
| | COMMENT TO HELP EXPEDITE THE REVIEW PROCESS. |
| | ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD |
| | DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS |
| | FOR REFERENCE. |
| | |