Plan Review Details - Permit 17120845
| Plan Review Stops For Permit 17120845 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2018-06-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-06-12 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-06-12 |
Time |
14:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2018-05-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-05-08 |
Time |
17:07 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-05-08 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2018-05-08 17:10:33 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE, 5TH EDITION W/2010 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 3RD REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PREVIOUS COMMENT NOT ADDRESSED. REMOVE VOIDED PLAN | | | SHEETS FROM SUBMITTAL AND RE-SUBMIT. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED AND MARK VOID. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-03-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-03-27 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-03-26 |
Time |
12:44 |
Sent To |
|
|
| Notes |
| 2018-03-27 09:29:37 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE, 5TH EDITION W/2010 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. WINDOW SCHEDULE LIST'S NOA 15-0511.05 FOR SH-7500 | | | SERIES WINDOWS. NOA 17-1017.06 SUBMITTED IS FOR | | | HORIZONTAL SLIDER WINDOWS. PLEASE CLARUFY. | | | 2. VALUE HAS NOT BEEN ADDRESSED. PROVIDE CONTRACT | | | SIGNED BY OWNER OR VALUE WILL BE SET BY BUILDING | | | OFFICIAL. | | | 3. PLAN SET HAS VOIDED PAGES. REMOVE VOIDED PAGES UPON | | | RE-SUBMITTAL. | | | | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING, WINDOW AND DOOR | | | SUBMITTALS. | | | | | | THE PERMIT VALUATION AND PERMIT FEE MUST BE | | | COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED | | | CONTRACTOR WOULD PROVIDE. | | | YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY THE | | | OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT | | | RENTAL TO VERIFY VALUE. | | | | | | CITY OF WPB CHPT. 1 ? VALUE | | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE | | | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION | | | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION | | | COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), | | | AS PUBLISHED BY INTERNATIONAL CODE CONGRESS. | | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | | BUILDING OFFICIAL. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED AND MARK VOID. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-01-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-01-08 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-01-06 |
Time |
13:45 |
Sent To |
P |
|
| Notes |
| 2018-01-08 09:11:50 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. SUBMITTAL INCLUDES NOA FOR SHUTTERS. NO REFERENCE TO | | | SHUTTERS IN APPLICATION OR ON PLANS. | | | 2. IF SHUTTERS ARE TO BE INCLUDED IN THIS SUBMITTAL | | | PROVIDE SHUTTER SCHEDULE AND INDICATED LOCATION OF | | | PROPOSED SHUTTER ON PLANS. | | | 3. PLANS INCLUDE WINDOW SCHEDULE. NO PRODUCT APPROVALS | | | ARE PROVIDED FOR WINDOWS IN THIS SUBMITTAL AND NO | | | REFERENCE IS MADE FOR WINDOWS ON APPLICATION. | | | 4. IF WINDOWS ARE TO BE INCLUDED IN THIS SUBMITTAL | | | PROVIDE PRODUCT APPROVALS FOR PROPOSED WINDOWS. | | | 5. BASED ON THE INFORMATION PROVIDED, VALUE CANNOT BE | | | DETERMINED AT THIS TIME. | | | THE PERMIT VALUATION AND PERMIT FEE MUST BE | | | COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED | | | CONTRACTOR WOULD PROVIDE. | | | YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY THE | | | OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT | | | RENTAL TO VERIFY VALUE. | | | | | | CITY OF WPB CHPT. 1 - VALUE | | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE | | | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION | | | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION | | | COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), | | | AS PUBLISHED BY INTERNATIONAL CODE CONGRESS. | | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | | BUILDING OFFICIAL. | | | | | | PROVIDE COMPLETED CITY OF WEST PALM BEACH - SCHEDULE | | | FOR INSTALLATION OF OPENING PROTECTIVE DEVICES AND | | | ASSEMBLIES | | | | | | FBC-R310.1 EMERGENCY ESCAPE - WINDOWS | | | EMERGENCY ESCAPE AND RESCUE REQUIRED IN BEDROOM 2 AS | | | FOLLOWS: WHERE EMERGENCY ESCAPE AND RESCUE OPENINGS ARE | | | PROVIDED THEY SHALL HAVE A SILL HEIGHT OF NOT MORE THAN | | | 44 INCHES (1118 MM) MEASURED FROM THE FINISHED FLOOR TO | | | THE BOTTOM OF THE CLEAR OPENING. R310.1.1 MINIMUM | | | OPENING AREA GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM | | | NET CLEAR OPENING OF 5 SQUARE FEET | | | R310.1.2 MINIMUM OPENING HEIGHT. | | | THE MINIMUM NET CLEAR OPENING HEIGHT SHALL BE 24 INCHES | | | R310.1.3 MINIMUM OPENING WIDTH. THE MINIMUM NET CLEAR | | | OPENING WIDTH SHALL BE 20 INCHES | | | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW SUBMITTALS. | | | | | | DUE TO THE DEFICIENCIES OF THIS PLAN, A COMPLETE AND | | | THOROUGH REVIEW CANNOT BE PERFORMED AT THIS TIME. UPON | | | RE-SUBMITTAL, ADDITIONAL COMMENTS MAY BE MADE. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED AND MARK VOID. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2018-05-02 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-05-02 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-05-02 |
Time |
09:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-03-07 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-03-07 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-03-07 |
Time |
11:40 |
Sent To |
|
|
| Notes |
| 2018-03-07 11:40:36 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY HAVE BEEN NOTED AS CORRECTED. ITEMS | | | REMAINING HAVE FURTHER COMMENTS IN PARENTHESES. | | | | | | 1. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND VALUE | | | OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THE | | | ESTIMATE PROVIDED DOES NOT APPEAR TO INCLUDE ALL OF THE | | | WORK. FBC 109.3 (CONTRACT PROVIDED DOES NOT SHOW ALL | | | WORK THAT IS DESCRIBED ON PLANS. PROVIDE ACCURATE COST | | | OF WORK INCLUDING LABOR AND MATERIALS.) | | | 2. CORRECTED. | | | 3. CORRECTED. | | | 4. CORRECTED. | | | 5. CORRECTED. | | | 6. CORRECTED. | | | 7. CORRECTED. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-01-05 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-01-05 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-01-05 |
Time |
13:52 |
Sent To |
|
|
| Notes |
| 2018-01-05 13:52:05 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND VALUE | | | OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THE | | | ESTIMATE PROVIDED DOES NOT APPEAR TO INCLUDE ALL OF THE | | | WORK. FBC 109.3 | | | 2. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO INTERIOR | | | PANEL. SHOW GEC SIZE AND SYSTEM, SHOW INTERSYSTEM | | | BONDING TERMINATION POINT. NEC 215.5, 230, 250.50, | | | 250.94, 408.30 FBC RE3706.1, RE3608.1, RE3609.3; FBC | | | 107.2.1 | | | 3. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE3602.3 | | | 4. PROVIDE CLARIFICATION OF SPACE IN FRONT OF | | | ELECTRICAL PANEL. IT APPEARS THAT THERE COULD BE A | | | CABINET THERE, ALTHOUGH THE PLAN DOES NOT STATE EITHER | | | WAY. THERE MUST BE 3 FEET OF CLEARANCE IN FRONT OF THE | | | PANEL. NEC 110.26; FBC 107.2.1 | | | 5. NOTE 3 AND NOTE 9 STATE THAT TAMPER RESISTANT | | | RECEPTACLES ARE REQUIRED. NOTE 3 QUOTES THE WRONG CODE | | | SECTION, NEC 406.11, WHICH DOES NOT PERTAIN TO TAMPER | | | RESISTANT RECEPTACLES. PROVIDE CORRECTION BY REMOVING | | | REDUNDANT NOTE THAT IS WRONG, OR CORRECTING NOTE. FBC | | | 107.2.1 | | | 6. NOTE 7 RELATES TO BROWARD COUNTY. THIS PROJECT IS | | | NOT LOCATED IN BROWARD, PLEASE REMOVE THIS REFERENCE. | | | FBC 107.2.1 | | | 7. PALM BEACH COUNTY PROPERTY APPRAISER WEBSITE STATES | | | THAT THERE IS NO AC/HEAT IN THIS HOUSE. THERE WAS AN | | | APPLICATION TO INSTALL 4 A/C'S SUBMITTED TO THE CITY IN | | | APRIL OF 2017, BUT THIS PERMIT WAS NEVER ISSUED. THE | | | PLAN SUBMITTED STATES THAT EXISTING UNITS WILL BE | | | REPLACED, HOWEVER, NONE SHOULD HAVE BEEN INSTALLED | | | WITHOUT A PERMIT. PLEASE CLARIFY WHAT WILL BE | | | INSTALLED. PROVIDE DETAIL OF ANY ELECTRICAL INSTALLED | | | TO THESE UNITS, AS THEY NEED A DEDICATED CIRCUIT. FBC | | | 107.2.1, NEC 422.12 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2018-06-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-06-12 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-06-08 |
Time |
11:19 |
Sent To |
I |
|
| Notes |
| 2018-06-11 11:19:52 | RESUB ROUTED TO HMOSER |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-05-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-05-08 |
Time |
17:10 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-04-18 |
Time |
16:00 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-03-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-03-27 |
Time |
09:29 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-02-21 |
Time |
14:24 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-01-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-01-08 |
Time |
17:35 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-12-21 |
Time |
09:46 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2018-06-12 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-06-12 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2018-06-12 |
Time |
09:03 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2018-01-02 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-01-02 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2018-01-02 |
Time |
14:29 |
Sent To |
|
|
| Notes |
| 2018-01-02 14:31:01 | MECHANICAL PERMIT NOT REQUIRED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2018-05-01 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-05-01 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-05-01 |
Time |
15:41 |
Sent To |
|
|
| Notes |
| 2018-05-01 15:59:06 | 05/01/18 APPROVED BY PLUMBING AND PUT BACK IN R02, LAC |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2018-03-14 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-03-14 |
Time |
06:05 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-03-14 |
Time |
06:05 |
Sent To |
|
|
| Notes |
| 2018-03-14 06:06:43 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: PREVIOUS COMMENT NOT COMPLIED | | | | | | 1- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | | LOW BASED ON ALL THE SCOPE OF WORK SHOWN ON PLANS | | | SUBMITTED. VALUATION TO INCLUDE ALL LABOR, MATERIALS, | | | CONTRACTOR'S OVERHEAD AND PROFIT AS REQUIRED BY SEC. | | | 109.3 CITY AMENDMENTS. UPDATE VALUATION. SEE COMMENTS | | | BY OTHER TRADES. | | | NEW 1)THE PROPOSALS THAT WERE PROVIDED WERE NOT SIGNED | | | AND DO NOT INCLUDED THE COMPLETE SCOPE OF WORK THAT IS | | | SHOWN ON THE PLAN. REQUIRED A SIGNED CONTRACT WITH A | | | BREAK DOWN OF THE COST OF MATERIALS AND LABOR FOR ALL | | | THE WORK UNDER SCOPE OF WORK AND SHOWN ON THE PLAN. | | | | | | PER WPB AMEND TO FBC 109.3 BUILDING PERMIT VALUATIONS. | | | IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE | | | CLAIMED VALUATION OF | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOW | | | DETAILED, QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED | | | CONTRACTS (EXCLUDING LAND VALUE) TO MEET THE | | | APPROVAL OF THE BUILDING OFFICIAL. FOR PERMITTING | | | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL | | | BE TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING | | | ONLY LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE | | | LATEST PUBLISHED DATA OF NATIONAL CONSTRUCTION | | | COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), | | | AS PUBLISHED BY INTERNATIONAL CODE CONGRESS. | | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | | BUILDING OFFICIAL. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-01-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-01-08 |
Time |
17:29 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-01-08 |
Time |
17:17 |
Sent To |
|
|
| Notes |
| 2018-01-08 17:35:33 | RESIDENTIAL (R3) ALTERATION, PLUMBING REVIEW COMMENTS. | | | CODE: FBC 5TH EDITION (2014). | | | | | | 1- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | | LOW BASED ON ALL THE SCOPE OF WORK SHOWN ON PLANS | | | SUBMITTED. VALUATION TO INCLUDE ALL LABOR, MATERIALS, | | | CONTRACTOR'S OVERHEAD AND PROFIT AS REQUIRED BY SEC. | | | 109.3 CITY AMENDMENTS. UPDATE VALUATION. SEE COMMENTS | | | BY OTHER TRADES. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
|