| Plan Review Stops For Permit 17120495 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-04-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-04-02 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-04-02 |
Time |
07:37 |
Sent To |
|
|
| Notes |
| 2018-04-02 11:50:33 | OCCUPANCY: A-2 | | | BUILDING TYPE: II-B | | | SPRINKLERED | | | 3520 SQ. FT. | | | 145 OCCUPANT LOAD | | | FLOOD ZONE-NO | | | 2 RESTROOMS | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-02-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-02-23 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-02-23 |
Time |
11:52 |
Sent To |
|
|
| Notes |
| 2018-02-23 15:32:32 | 2014 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 17120495 | | | W. P. B. PERMIT: 17060769 (SHELL) | | | ADD: 1560 PALM BEACH LAKES BLVD. SUITE # 08 | | | CONT: U.S. CONSTRUCTION | | | TEL: 407-399-4630 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2ND REVIEW | | | DATE: FRI. FEB. 23/ 2018 | | | ACTION: DENIED | | | | | | 1) COMPLIED. | | | | | | 2) SEMI-COMPLIED. SHEET A1.0. THE ACCESSIBLE SEATING AT | | | THE COUNTER SHOWING A DROPPED SECTION WITH PIANO HINGE | | | IS NOT EQUIVALENT FACILITATION AS REQUIRED BY THE | | | FLORIDA ACCESSIBILITY CODE SECTION 103. | | | A PORTION OF THE COUNTER WILL NEED TO BE DROPPED TO | | | SHOW COMPLIANCE WITH THE ACCESSIBILITY CODE SECTION: | | | 902.1 .DINING SURFACES AND WORK SURFACES SHALL COMPLY | | | WITH 902.2 AND 902.3. | | | ADVISORY 902.1 GENERAL. DINING SURFACES INCLUDE, BUT | | | ARE NOT LIMITED TO, BARS, TABLES, LUNCH COUNTERS, AND | | | BOOTHS. | | | PLEASE ALSO SHOW AT LEAST ONE ACCESSIBLE BOOTH AND | | | COMPLIANCE WITH 226.2 DISPERSION. DINING SURFACES AND | | | WORK SURFACES REQUIRED TO COMPLY WITH 902 SHALL BE | | | DISPERSED THROUGHOUT THE SPACE OR FACILITY CONTAINING | | | DINING SURFACES.. | | | | | | 2)(A) 902.2 CLEAR FLOOR OR GROUND SPACE. A CLEAR FLOOR | | | SPACE COMPLYING WITH 305 POSITIONED FOR A FORWARD | | | APPROACH SHALL BE PROVIDED. KNEE AND TOE CLEARANCE | | | COMPLYING WITH 306 SHALL BE PROVIDED. | | | | | | 2)(B) 902.3 HEIGHT. THE TOPS OF DINING SURFACES AND | | | WORK SURFACES SHALL BE 28 INCHES MINIMUM AND 34 INCHES | | | MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. | | | | | | 1ST ROUND COMMENTS. SHEET A1.0 SHOWS APPROXIMATELY 130 | | | SEATS ON BOTH THE INTERIOR AND EXTERIOR OF THE A2 | | | OCCUPANCY AND OF THESE SEATS 7 SEATS ARE ACCESSIBLE | | | MEETING THE 5% ACCESSIBLE SEATING. WHAT THE FLOOR PLAN | | | DOES NOT SHOW IS DISPERSION BETWEEN TYPE OF DINING, | | | SUCH AS BANQUETS AND STOOLS; NONE OF THESE ELEMENTS | | | SHOW ACCESSIBLE SEATING. | | | 2014 FBC-ACCESSIBILITY CODE 226.2 DISPERSION. DINING | | | SURFACES AND WORK SURFACES REQUIRED TO COMPLY WITH 902 | | | SHALL BE DISPERSED THROUGHOUT THE SPACE OR FACILITY | | | CONTAINING DINING SURFACES AND WORK SURFACES. | | | | | | 3-4) COMPLIED. | | | | | | 5) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. ONE SET OF | | | PLANS WILL HAVE TO BE TAKEN (BY THE CONTRACTOR OR | | | REPRESENTATIVE) TO THE PALM BEACH COUNTY IMPACT FEE | | | OFFICE LOCATED AT 2300 N. JOG RD. ROOMS 2W01-2W14 WEST | | | PALM BEACH, FL. THE ACTUAL PERMIT SET OF PLANS MUST BE | | | STAMPED BY THAT OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. PLEASE CALL | | | (561)233-5025 FOR MORE INFORMATION. | | | | | | 6) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-12-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-12-19 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-12-19 |
Time |
10:52 |
Sent To |
|
|
| Notes |
| 2017-12-19 15:50:31 | 2014 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 17120495 | | | W. P. B. PERMIT: 17060769 (SHELL) | | | ADD: 1560 PALM BEACH LAKES BLVD. SUITE # 08 | | | CONT: U.S. CONSTRUCTION | | | TEL: 407-399-4630 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 1ST REVIEW | | | DATE: TUES. DEC. 19/ 2017 | | | ACTION: DENIED | | | | | | 1) THE COVERSHEET CS1 INDICATES THIS BUILDING IS | | | DESIGNED UNDER THE 2014 FBC-EXISTING BUILDING CODE AND | | | AS AN ALTERATION LEVEL II. PLEASE REVIEW BUILDINGS THAT | | | WERE NEVER PREVIOUSLY OCCUPIED ARE TO BE DESIGNED & | | | REVIEW UNDER THE: | | | 2014 FBC-BUILDING. 101.4.1 BUILDINGS NOT PREVIOUSLY | | | OCCUPIED. A BUILDING OR PORTION OF A BUILDING THAT HAS | | | NOT BEEN PREVIOUSLY OCCUPIED OR USED FOR ITS INTENDED | | | PURPOSE IN ACCORDANCE WITH THE LAWS IN EXISTENCE AT THE | | | TIME OF ITS COMPLETION SHALL COMPLY WITH THE PROVISIONS | | | OF THE FLORIDA BUILDING CODE, BUILDING OR FLORIDA | | | BUILDING CODE, RESIDENTIAL, AS APPLICABLE, FOR NEW | | | CONSTRUCTION OR WITH ANY CURRENT PERMIT FOR SUCH | | | OCCUPANCY. | | | PLEASE DELETE THE REFERENCE TO THE EXISTING BUILDING | | | CODE AND LEVEL II ALTERATION. | | | | | | 2) SHEET A1.0 SHOWS APPROXIMATELY 130 SEATS ON BOTH THE | | | INTERIOR AND EXTERIOR OF THE A2 OCCUPANCY AND OF THESE | | | SEATS 7 SEATS ARE ACCESSIBLE MEETING THE 5% ACCESSIBLE | | | SEATING. WHAT THE FLOOR PLAN DOES NOT SHOW IS | | | DISPERSION BETWEEN TYPE OF DINING, SUCH AS BANQUETS AND | | | STOOLS; NONE OF THESE ELEMENTS SHOW ACCESSIBLE SEATING. | | | 2014 FBC-ACCESSIBILITY CODE 226.2 DISPERSION. DINING | | | SURFACES AND WORK SURFACES REQUIRED TO COMPLY WITH 902 | | | SHALL BE DISPERSED THROUGHOUT THE SPACE OR FACILITY | | | CONTAINING DINING SURFACES AND WORK SURFACES. | | | | | | 3) SHEET A2.1 AND A2.2 SHOWS AWNINGS AND SIGNAGE, BOTH | | | OF THESE ITEMS REQUIRE A SEPARATE PERMIT, REVIEW AND | | | ASSOCIATED FEES. | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION 105.1 PERMITS REQUIRED. | | | | | | 4A) SHEET A4.2 DETAIL 2 AND SHEET M3.1 SHOW THE | | | INSTALLATION OF A ROOF TOP CONDENSING STAND PLEASE SHOW | | | COMPLIANCE WITH: | | | 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | | OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, | | | RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS | | | OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | | APPROVALS: | | | (31) (G) PRE-ENGINEERED A/C STANDS | | | | | | 4B) W. P. B. 107.3.4.1 PRODUCT APPROVALS. THOSE | | | PRODUCTS WHICH ARE REGULATED BY THE DCA RULE 9N-03 | | | SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. FL 61G1-23.015 (2) THE | | | ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND REVIEWING | | | ALL PROJECT DATA, REPORTS, SHOP DRAWINGS ETC.. | | | | | | 4C) THE ROOF TOP A/C STAND PRODUCT APPROVALS. PLEASE | | | IDENTIFY THE FOLLOWING REQUIREMENTS CALCULATING THE | | | AREA (SIDE VIEW) OF THE ROOF TOP COMPRESSORS, | | | CONFIGURATION ON STAND, THE MEAN ROOF HEIGHT OF THE | | | STAND AND COMPRESSORS, WEIGHT, CIRCLED THE DESIGN | | | PARAMETERS IN THE TABLES, ANCHORS AND UPLIFT VERSES | | | MOMENT FOR THE UNIT TO THE STAND AND THE STAND TO THE | | | ROOF. THE PRODUCT APPROVAL IS TO BE REVIEWED BY THE | | | DESIGNER OF RECORD, APPROVED BEFORE SUBMISSION TO THE | | | BUILDING DEPARTMENT. | | | | | | 2014 FBC-B 1604.4 ANALYSIS. LOAD EFFECTS ON STRUCTURAL | | | MEMBERS AND THEIR CONNECTIONS SHALL BE DETERMINED BY | | | METHODS OF STRUCTURAL ANALYSIS THAT TAKE INTO ACCOUNT | | | EQUILIBRIUM, GENERAL STABILITY, GEOMETRIC COMPATIBILITY | | | AND BOTH SHORT- AND LONG-TERM MATERIAL PROPERTIES. | | | EVERY STRUCTURE SHALL BE DESIGNED TO RESIST THE | | | OVERTURNING EFFECTS CAUSED BY THE LATERAL FORCES | | | SPECIFIED IN THIS CHAPTER. SEE SECTION 1609 FOR WIND | | | LOADS. | | | | | | 5) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. ONE SET OF | | | PLANS WILL HAVE TO BE TAKEN (BY THE CONTRACTOR OR | | | REPRESENTATIVE) TO THE PALM BEACH COUNTY IMPACT FEE | | | OFFICE LOCATED AT 2300 N. JOG RD. ROOMS 2W01-2W14 WEST | | | PALM BEACH, FL. THE ACTUAL PERMIT SET OF PLANS MUST BE | | | STAMPED BY THAT OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. PLEASE CALL | | | (561)233-5025 FOR MORE INFORMATION. | | | | | | 6) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-03-05 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-03-05 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-03-05 |
Time |
09:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-01-02 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-01-02 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-01-02 |
Time |
15:49 |
Sent To |
|
|
| Notes |
| 2018-01-02 15:49:24 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. SHEET EO.1, NOTE 10 REFERENCES NEC 250.95 FOR | | | EQUIPMENT GROUNDING CONDUCTOR SIZE. THIS CODE SECTION | | | DOES NOT EXIST IN THE 2011 NEC. PROVIDE CORRECTION. NEC | | | 250.122; FBC 107.2.1 | | | 2. RISER SHOWS AN EXISTING SERVICE, BUT THE PROPERTY | | | APPRAISER'S SITE SHOWS THIS AS A VACANT LOT. WHAT IS | | | EXISTING ON SITE? IF THIS IS FED FROM AN EXISTING | | | SERVICE, PROVIDE LOAD CALCULATION FOR ENTIRE SERVICE. | | | PROVIDE CLARIFICATION. NEC 220, FBC 107.2.1 | | | 3. PROVIDE GROUNDING ELECTRODE SYSTEM AND CONDUCTORS | | | PER CODE. PROVIDE DETAIL ON PLAN. NEC 250.50, 250.66; | | | FBC 107.2.1 | | | 4. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | | SERVICE. NEC 250.94 | | | 5. BE ADVISED THAT FIRE ALARM, LOW VOLTAGE SYSTEMS, | | | LIGHTNING PROTECTION, GENERATORS, COMMERCIAL HOOD | | | SYSTEMS, SIGNS, SITE LIGHTING, AND SWIMMING POOLS | | | (WHERE APPLICABLE) ARE NOT INCLUDED IN THE SCOPE OF | | | THIS PLAN REVIEW. PROVIDE A BLOCK NOTE INDICATING THE | | | REQUIRED SEPARATE PERMITS AND DATA SPECIFICATION SHEET | | | SUBMITTALS FOR ANY OF THESE SYSTEMS PRESENT. FBC 105.1, | | | 107.2.1 | | | 6. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10 | | | 7. IT APPEARS THAT THE PANEL SCHEDULES HAVE NOT BEEN | | | COMPLETELY FILLED OUT. DOES PANEL A HAVE A MAIN | | | BREAKER, OR WILL THERE BE A DISCONNECT OUTSIDE? PROVIDE | | | CLARIFICATION. FBC 107.2.1; NEC 230.71 | | | 8. PROVIDE NOTES TO INDICATE THE REQUIRED MARKING OF | | | SERVICE EQUIPMENT FOR ARC FLASH HAZARD WARNING AND | | | AVAILABLE FAULT CURRENT PER CODE. NEC 110.16, 110.24 | | | 9. PROVIDE GRAPH/CALCULATION OF INTERIOR LIGHTING POWER | | | ALLOWANCES EXPRESSED IN WATTAGE PER THE FBC ENERGY CODE | | | IN RELATION TO THE WATTAGE OF THE CONNECTED INTERIOR | | | LIGHTING PROPOSED TO COMPLY WITH CODE. FBC EC 405.5.2 | | | 10. PROVIDE THE ADDITIONAL LIGHTING CONTROLS STIPULATED | | | IN THE FBC ENERGY CODE. MANY AREAS DO NOT SHOW THE | | | AUTOMATIC CONTROL REQUIRED. FBC EC 405.2.2, 405.2.2.2, | | | 405.2.4 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2018-03-30 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-03-30 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-03-30 |
Time |
11:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-02-15 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-02-15 |
Time |
12:05 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-02-15 |
Time |
12:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2017-12-20 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2017-12-20 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2017-12-20 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2017-12-20 14:51:58 | 1560 PALM BEACH LAKES BOULEVARD - SUITE #8 | | | PERMIT #17120495 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | FOR ISSUANCE OF A GENERAL BUILDING PERMIT, SECTION | | | 105.3.1.2(2) OF THE FLORIDA BUILDING CODE REQUIRES | | | SEALED FIRE PROTECTION CONSTRUCTION DOCUMENTS FOR THE | | | DESIGN OR ALTERATION OF 50 OR MORE AUTOMATIC FIRE | | | SPRINKLERS. AFTER THE BUILDING PERMIT HAS BEEN ISSUED, | | | THE SUBCONTRACTORS CAN THEN SUBMIT SHOP DRAWINGS | | | (CONFORMING TO THE ENGINEERED CONSTRUCTION DOCUMENTS) | | | FOR A SUB-PERMIT. PER FLORIDA ADMINISTRATIVE CODE | | | SECTION 61G15-32.004, FIRE PROTECTION ENGINEERING | | | DOCUMENTS SHALL INCLUDE THE POINT OF SERVICE FOR THE | | | WATER SUPPLY, A LIST OF APPLICABLE NFPA STANDARDS | | | APPLICABLE TO THE PROJECT, CLASSIFICATION OF HAZARD | | | OCCUPANCY FOR EACH ROOM OR AREA, SUPPRESSION SYSTEM | | | TYPE, DESIGN DENSITIES, WATER SUPPLY DATA (FIRE PUMP | | | DATA, HYDRANT FLOW TEST DATA) AND ANY PERFORMANCE BASED | | | INFORMATION SUCH AS PRE-ENGINEERED SYSTEMS. | | | | | | PROVIDE AN EXTERIOR KEY SAFE TO ALLOW EMERGENCY | | | RESPONDERS NON-FORCIBLE ENTRY INTO THE BUILDING DURING | | | NON-BUSINESS HOURS. A KEY SAFE CAN BE ORDERED FROM | | | WWW.KNOXBOX.COM. | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2018-04-09 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-04-09 |
Time |
17:31 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-04-09 |
Time |
17:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2018-03-08 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-03-08 |
Time |
12:24 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2018-03-08 12:35:56 | 2ND REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. THE BTU LOAD FOR THE FRYER DOES NOT MATCH , ON THE | | | COMBUSTION AIR CALCS IT LIST 330 MBTU ON THE RISER IT | | | LIST 360 MBTU.PLEASE CLARIFY PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | 2. THE RISER AND EQUIPMENT SCHEDULE LIST THE CONVECTION | | | OVEN AT 100 MBTU THE MANUFACTURE SPECS LIST 88 MBTU. | | | PLEASE CLARIFY PER WPB AMEND TO FBC 107.2.1 | | | | | | 3. THE RISER AND EQUIPMENT SCHEDULE LIST THE1 FRYER AT | | | 360 MBTU THE MANUFACTURE SPECS LIST MODEL SG14 AT110 | | | MBTU.PLEASE CLARIFY PER WPB AMEND TO FBC 107.2 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-01-08 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-01-08 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-01-08 |
Time |
15:18 |
Sent To |
|
|
| Notes |
| 2018-01-08 15:22:44 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. WHERE A SEDIMENT TRAP IS NOT INCORPORATED AS PART OF | | | THE APPLIANCE, A SEDIMENT TRAP SHALL BE INSTALLED | | | DOWNSTREAM OF THE APPLIANCE SHUTOFF VALVE AS CLOSE TO | | | THE INLET OF THE APPLIANCE AS PRACTICAL. PER FBC FG | | | 408.4 | | | | | | 2. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE | | | FBC-2014 FUEL GAS CODE SEC. 304. | | | | | | 3. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE AND | | | TERMINATION OF THE GAS VENTS PER FBC-2014 FUEL GAS CODE | | | SEC. 502 THRU 505. | | | | | | 4. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL | | | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA | | | 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-04-10 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-04-10 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2018-03-28 |
Time |
13:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-03-13 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-03-13 |
Time |
17:52 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-02-13 |
Time |
13:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-01-22 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-01-22 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2017-12-13 |
Time |
14:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2018-04-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-04-02 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-04-02 |
Time |
10:42 |
Sent To |
|
|
| Notes |
| 2018-04-02 10:59:52 | PALM BEACH COUNTY IMPACT FEE OFFICE | | | DATE RECEIVED: 03/28/2018 | | | RECEIPT NUMBER: 2018-0328-274 | | | TRACKING NUMBER: MU-2018-003337-0000 | | | TOTAL AMOUNT: $4,954.99 | | | | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2018-02-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-02-23 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-02-23 |
Time |
15:13 |
Sent To |
|
|
| Notes |
| 2018-02-23 15:13:56 | IMPACT FEES | | | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. ONE SET OF | | | PLANS WILL HAVE TO BE TAKEN (BY THE CONTRACTOR OR | | | REPRESENTATIVE) TO THE PALM BEACH COUNTY IMPACT FEE | | | OFFICE LOCATED AT 2300 N. JOG RD. ROOMS 2W01-2W14 WEST | | | PALM BEACH, FL. THE ACTUAL PERMIT SET OF PLANS MUST BE | | | STAMPED BY THAT OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. PLEASE CALL | | | (561)233-5025 FOR MORE INFORMATION. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2017-12-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-12-19 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-12-19 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2017-12-19 15:51:09 | 1) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. ONE SET OF | | | PLANS WILL HAVE TO BE TAKEN (BY THE CONTRACTOR OR | | | REPRESENTATIVE) TO THE PALM BEACH COUNTY IMPACT FEE | | | OFFICE LOCATED AT 2300 N. JOG RD. ROOMS 2W01-2W14 WEST | | | PALM BEACH, FL. THE ACTUAL PERMIT SET OF PLANS MUST BE | | | STAMPED BY THAT OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. PLEASE CALL | | | (561)233-5025 FOR MORE INFORMATION. | | | | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2018-04-10 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-04-10 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2018-04-10 |
Time |
07:56 |
Sent To |
|
|
| Notes |
| 2018-04-10 08:22:04 | PASS PROVISO | | | SEPARATE APPLICATION, PLANS, AND PERMITS REQUIRED | | | FOR HOODS, AND COOLERS | | | | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 516-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2018-02-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-02-28 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-02-28 |
Time |
08:59 |
Sent To |
|
|
| Notes |
| 2018-02-28 10:22:58 | 2ND REVIEW FBC-2014 MECHANICAL | | | PERMIT #17120495 | | | 2/28/18 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET M1.1 COMBUSTION AIR CALCULATION: PLEASE REFER | | | TO SHEETS CS1 AND A1.3. BASED ON THE 3520 SQ. FT. AREA | | | AND AN AVERAGE CEILING HEIGHT OF 9'6" THE MAXIMUM | | | VOLUME OF THE SPACE IN CUBIC FEET WOULD BE 33,440. THAT | | | TOTAL WOULD ALSO BE CUT DRASTICALLY WHEN DEDUCTING | | | CLOSED OFF SPACES SUCH AS THE RESTROOMS, STORAGE, AND | | | OFFICE ROOMS ETC. HOW ARE YOU CALCULATING THE | | | | | | INDOOR VOLUME AT 46.392 FT3. IT DOES NOT SEEM | | | PHYSICALLY POSSIBLE. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-12-27 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-12-27 |
Time |
12:30 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-12-27 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2017-12-27 12:57:31 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #17120495 | | | 12/27/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) DUE TO THE LOW WALLS SEPARATING THE KITCHEN AND THE | | | DINING ROOMS, IT APPEARS THAT SOME OF THE AIR SUPPLIED | | | TO THE KIITCHEN WILL BE RECIRCULATED INTO THE DINING | | | ROOM WHICH IS PROHIBITED- TABLE 403.3 FOOTNOTE B. | | | | | | 2) PROVIDE COMBUSTION FOR THE COOKING APPLIANCES AND | | | SHOW HOW THE AIR WILL BE PROVIDED- SEE SECTION 304 | | | FBC-14 FUEL GAS. | | | | | | 3) SEPARATE PERMITS ARE REQUIRED FOR THE KITCHEN HOODS, | | | THE FIRE SUPPRESSION SYSTEMS, AND THE WALK-IN COOLER | | | AND FREEZER. PLEASE PLACE A NOTE ON THE PLAN. | | | | | | ADVISORY- KITCHEN HOOD PLANS: COMPLIANCE WITH SECTION | | | 508.1.1 MAKEUP AIR TEMPERATURE WILL BE REQUIRED. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2018-04-09 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-04-09 |
Time |
17:07 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-04-09 |
Time |
09:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2018-03-08 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-03-08 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-03-08 |
Time |
11:47 |
Sent To |
|
|
| Notes |
| 2018-03-08 12:23:46 | | | | 2ND REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. THE GREASE INTERCEPTOR SIZING CALCULATIONS SHALL | | | INCLUDE ALL THE FLOOR DRAINS, FLOOR SINKS, TROUGH | | | DRAINS AND HUBDRAINS RECEIVING DISCHARGE OF GREASY | | | WASTE SUCH AS THE KETTLE.AND HOT WELLS OR USE THE | | | SIZING METHOD FOR RESTAURANT USING THE NUMBER OF SEATS | | | X GALLONS PER SEAT X HR OF OPERATION X LOAD FACTOR. PER | | | FBC PL 1003.2, 1003.3.1 | | | | | | 2. ON THE WATER RISER SHUT OFF VALVES ARE REQUIRED ON | | | ALL DROPS A NOTE ON THE PLAN SHALL COMPLY. PER FBC PL | | | 606.1(5) | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-01-08 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-01-08 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-01-08 |
Time |
07:35 |
Sent To |
|
|
| Notes |
| 2018-01-08 15:12:06 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. THE GRAB BARS SHALL BE MEASURED TO THE TOP OF THE | | | GRIPPING SURFACE IF MEASURED TO CENTERLINE OF BAR TO | | | THE MAX OF 36" BARS WILL BE INSTALLED TO HIGH. PER FBC | | | ACC 609.4 | | | | | | 2. SHT. A7.1-7.2 DETAILS SHOWS HORIZONTAL GRAB BARS PER | | | FBC ACC 909.4 GRAB BARS SHALL BE INSTALLED IN A | | | HORIZONTAL POSITION, | | | | | | 3. SHT. P1.1 SHOWS 3 GREASE INTERCEPTORS THE APPROVED | | | PLANS FOR BUILDING SHELL SHOW FOUR GREASE INTERCEPTORS | | | PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 4. THE SANITARY ISOMETRIC IS TO COMPACT TO DETERMINE | | | CODE COMPLIANCE PLEASE EXPAND AND SEPARATE THE SANITARY | | | AND GREASE ISOMETRIC DRAWINGS. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | 5. PROVIDE WATER ISOMETRIC SHOWING PIPE SIZE, ALL | | | VALVES, HAMMER ARESTORS AND BACK FLOWS. PER WPB AMEND | | | TO FBC 107.3.5.1.3(13) | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-03-13 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2018-03-13 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2018-03-13 |
Time |
15:48 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-01-22 |
|
|
Cont ID |
|
| Sent By |
JR |
Date |
2018-01-22 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2018-01-16 |
Time |
14:51 |
Sent To |
PC |
|
| Notes |
| 2018-01-22 14:15:04 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 01.22.2018 | | | PERMIT NO.: 17120495 | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. STAFF IS CONCERNED WITH REGARD TO THE ?BLACKOUT? AND | | | ?NEW WALL? THAT IS PROPOSED TO BE CONSTRUCTED BEHIND | | | NEARLY EVERY ONE OF THE STOREFRONT WINDOWS THAT WERE | | | APPROVED THROUGH THE MAJOR PLANNED DEVELOPMENT | | | AMENDMENT PROCESS. THESE STOREFRONTS WERE SPECIFICALLY | | | ADDED DURING APPROVAL PROCESS FOR THE SITE PLAN AND IT | | | IS COUNTERINTUITIVE TO HAVE EACH OF THEM BLOCKED OFF. | | | STAFF WOULD LIKE TO DISCUSS THIS MATTER TO SEE IF THERE | | | ARE ALTERNATIVES THAT WOULD MAINTAIN TRANSPARENCY INTO | | | THE SPACE. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|