Plan Review Details - Permit 17120118
Plan Review Stops For Permit 17120118
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date   Cont ID  
Sent By jwitmer Date 2018-02-08 Time 07:20 Rev Time 0.00
Received By jwitmer Date 2018-02-08 Time 06:56 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-01-05 Cont ID  
Sent By jwitmer Date 2018-01-05 Time 11:26 Rev Time 0.00
Received By jwitmer Date 2018-01-05 Time 11:11 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-12-06 Cont ID  
Sent By jwitmer Date 2017-12-06 Time 07:26 Rev Time 0.00
Received By jwitmer Date 2017-12-06 Time 06:47 Sent To E
Notes
2017-12-06 07:25:592014 FBC- BUILDING PLAN REVIEW
 W. P. B. REVISION: 17120118
 W. P. B. PERMIT: 17050118
 ADD: 4420 BEACON CIRCLE
 CONT: DWW CONSTRUCTION INC.
 TEL: 772-215-2794
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. DEC. 06/2017
 ACTION: DENIED
  
 1) THE REVISION SHEET, SHEET # 2 DOES NOT HAVE THE
 REVISIONS INDICATED WITH BUBBLE OR DELTAS. THE REVISION
 REQUEST PLAN REVIEW FORM LIST THE DESCRIPTION OF WORK.
 THIS FORM DOES NOT STATE THERE ARE INTERIOR REVISIONS
 AS WELL. 107.2.1.3 ADDITIONAL INFORMATION REQUIRED ON
 PLANS WHERE THE REVISIONS ARE LOCATED.
  
 2) SHEET # 2 SHOWS INTERIOR REVISIONS THAT DELETE A
 RESTROOM AND WATER HEATER AND CLOSET. THERE WERE NO
 PLUMBING SHEETS OR DEMO SHEETS SHOWING THE REVISION.
 107. 2.1.3. ADDITIONAL INFORMATION IS REQUIRED.
  
 3) SHEET # 2 IN THE HALLWAY BETWEEN THE (2) PROPOSED
 CUBICLES NOW SHOWS A NEW DOOR IN A PROPOSED 4 FOOT WIDE
 HALLWAY. 2014 EXISTING BUILDING CODE. 801.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, 2014 ACCESS. CODE 404.2.4
 MANEUVERING CLEARANCES. MINIMUM MANEUVERING CLEARANCES
 AT DOORS AND GATES SHALL COMPLY WITH 404.2.4.
 MANEUVERING CLEARANCES SHALL EXTEND THE FULL WIDTH OF
 THE DOORWAY AND THE REQUIRED LATCH SIDE OR HINGE SIDE
 CLEARANCE. MISSING THE REQUIRED 18 INCHES LATCH SIDE OF
 DOOR FOR MANEUVERING CLEARANCE.
  
 4) SHEET # 2 A NEW DOORWAY IN THE CORRIDOR BETWEEN THE
 2 PROPOSED CUBICLES WILL NOW ALSO NEED DIRECTIONAL EXIT
 LIGHTING TO BE SHOWN ON SHEET # 3 THE ELECTRICAL PLAN.
 2014 FBC-B 1011.1 WHERE REQUIRED.
  
 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2017-12-28 Cont ID  
Sent By jleahy Date 2017-12-28 Time 10:53 Rev Time 0.00
Received By jleahy Date 2017-12-28 Time 10:51 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-12-06 Cont ID  
Sent By jleahy Date 2017-12-06 Time 07:54 Rev Time 0.00
Received By jleahy Date 2017-12-06 Time 07:54 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2018-02-08 Time   Rev Time 0.00
Received By lmarchan Date 2018-02-05 Time 09:17 Sent To  
Notes
2018-02-07 09:17:14RESUB OF REVISION ROUTED TO GJOHNSON

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2018-01-05 Time   Rev Time 0.00
Received By lmarchan Date 2017-12-19 Time 11:00 Sent To  
Notes
2017-12-20 11:00:33RESUB ROUTED TO JLEAHY

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-12-08 Cont ID  
Sent By gjohnson Date 2017-12-08 Time 06:55 Rev Time 0.00
Received By gjohnson Date 2017-12-04 Time 10:45 Sent To  
Notes
2017-12-05 10:46:01REVISION ROUTED TO JWITMER

Review Stop P PLUMBING
Rev No 3 Status P Date 2018-02-07 Cont ID  
Sent By gjohnson Date 2018-02-07 Time 13:08 Rev Time 0.00
Received By gjohnson Date 2018-02-07 Time 13:08 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2018-01-04 Cont ID  
Sent By gjohnson Date 2018-01-04 Time 08:28 Rev Time 0.00
Received By gjohnson Date 2018-01-04 Time 08:28 Sent To  
Notes
2018-01-04 08:38:212ND REVIEW: FBC 2014 5TH EDITION
  
 PLUMBING COMMENTS:
  
 1. YOU ARE ELIMINATING TWO WATER HEATERS AND STATING
 THAT A THIRD EXISTING WATER HEATER WILL BE USED TO
 SUPPLY ALL HOT WATER PLEASE SHOW LOCATION OF EXISTING
 HEATER THAT IS REMAINING. PER WPB AMEND TO FBC 107.2.1
  
 2. IF ANY PLEASE SHOW ANY NEW HOT WATER PIPING PROVIDE
 ISOMETRIC DIAGRAM. . PER WPB AMEND TO FBC
 107.3.5.1.3(13)
  
 3. IF NEW HIT WATER PIPING IS OVER 50' A RECIRCULATION
 HOT WATER SYSTEM IS REQUIRED. PER FBC PL 607.2
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-12-08 Cont ID  
Sent By gjohnson Date 2017-12-08 Time 06:49 Rev Time 0.00
Received By gjohnson Date 2017-12-08 Time 06:49 Sent To  
Notes
2017-12-08 06:54:521ST REVIEW: FBC 2014 5TH EDITION
  
 PLUMBING COMMENTS:
  
 1. PLEASE PROVIDE DETAILED SCOPE OF PLUMBING WORK
 PLEASE SHOW ON PLANS. PER WPB AMEND TO FBC 107.2.1
  
 2. IT APPEARS YOU ARE ELIMINATING THE WATER HEATER
 PLEASE INDICATE ON THE PLAN HOW YOU ARE GOING TO SUPPLY
 THE REQUIRED HOT WATER. PER FBC PL 607.1
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  