|
 |
 |
 |
 |
 |
Plan Review Details - Permit 17111018
| Plan Review Stops For Permit 17111018 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-12-08 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-12-08 |
Time |
07:37 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-12-08 |
Time |
07:37 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-12-01 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-12-01 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-12-01 |
Time |
16:30 |
Sent To |
I |
|
| Notes |
| 2017-12-01 16:30:49 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. WE RECEIVED THE LOAD CALCULATION AND PANEL SCHEDULE, | | | BUT THERE IS NO ELECTRICAL PLAN SHOWING WHAT IS TO BE | | | INSTALLED. PROVIDE ELECTRICAL PLAN SHOWING LOCATION OF | | | UNITS TO BE WIRED, AND WIRE SIZE TO THE UNITS. FBC | | | 107.2.1 | | | 2. PROVIDE GFCI PROTECTED OUTLET FOR SERVICING OF A/C | | | EQUIPMENT PER CODE. NEC 210.63; FBC RE3901.12 | | | 3. PROVIDE FLOOR PLAN SHOWING ALL SMOKE ALARMS REQUIRED | | | PER CODE. SHOW ON PLAN ALL EXISTING ALARMS. IF NONE ARE | | | EXISTING OR NOT TO CODE, SHOW AS NEW INSTALLATIONS. FBC | | | R314.3, FBC 107.2.1 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-12-08 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-12-08 |
Time |
07:37 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-12-07 |
Time |
18:13 |
Sent To |
|
|
| Notes |
| 2017-12-07 18:14:05 | JPEARSON'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-12-01 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-12-01 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-11-28 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2017-11-29 11:19:13 | ELEC <5K |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |