| Plan Review Stops For Permit 17111014 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
3 |
Status |
P |
Date |
2018-03-01 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-03-01 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-03-01 |
Time |
15:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
F |
Date |
2018-01-04 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-01-04 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-01-04 |
Time |
10:32 |
Sent To |
|
|
| Notes |
| 2018-01-04 10:37:16 | | | | ****PLAN REVIEW COMMENTS**** | | | | | | ART LANGE BUILDING PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FL 33402 | | | 561-805-6718 [email protected] | | | | | | 2ND REVIEW: | | | | | | THIS BUILDING IS ADDRESS CORRECTLY BUT ON SP 1 THERE IS | | | A SECOND BUILDING WITH THE SAME ADDRESS. ITS ADDRESS IS | | | SHOWN AS 2211 AND SHOULD BE 2221. | | | | | | THE ADDRESS OF 2211 N AUSTRALIAN IS USED FOR TWO | | | BUILDINGS AS SHOWN ON SP 1. | | | | | | ADDRESSING: CITY MUNI CODE SEC.78-6 (1-7) | | | | | | (2) LOCATION, BUILDINGS CONTAINING MORE THAN ONE | | | ADDRESS. ALL ADDRESSES SHALL BE POSTED ON THAT PORTION | | | OF THE STRUCTURE FRONTING OR FACING UPON THE STREET OR | | | PRINCIPAL VEHICULAR ACCESS TO THE PREMISES, SO AS TO BE | | | READILY VISIBLE TO APPROACHING VEHICLES. OWNERS OR | | | TENANTS OF ALL HOUSES AND BUILDINGS USING A SERVICE | | | ALLEY SHALL ALSO POST A NUMBER ON THE SIDE OF THE | | | BUILDINGS ADJACENT TO AND FACING SUCH ALLEY. IF THE | | | HOUSE OR BUILDING IS OBSTRUCTED BY A FENCE, THEN THE | | | NUMBER SHALL BE POSTED ON THE FENCE. THE PLACEMENT OF | | | NUMBERS ON BUILDINGS OR FENCES, AS THE CASE MAY BE, | | | SHALL BE SUBJECT TO THE DIRECTION OR APPROVAL OF THE | | | CITY'S CONSTRUCTION SERVICES DEPARTMENT. BUILDINGS | | | WHICH CONTAIN MORE THAN ONE RESIDENTIAL, COMMERCIAL, | | | INDUSTRIAL, OR INSTITUTIONAL ADDRESS SHALL POST A | | | SEPARATE ADDRESS MEETING THE REQUIREMENTS OF THIS | | | SECTION AT THE EXTERIOR ENTRANCE TO EACH INDIVIDUAL | | | ADDRESS OR COMMON EXTERIOR ENTRANCE TO SEVERAL | | | ADDRESSES THEREIN, AND THE UNIT NUMBER SHALL ALSO BE | | | POSTED ON THE EXTERIOR DOOR OF EACH UNIT SERVED BY SUCH | | | A COMMON EXTERIOR ENTRANCE. | | | | | | (3) MONUMENT SIGNS. ALL MONUMENT SIGNS FOR MULTIPLE | | | RESIDENTIAL, COMMERCIAL, INDUSTRIAL, OR INSTITUTIONAL | | | DEVELOPMENTS SHALL POST THE ADDRESS RANGE FOR THE | | | DEVELOPMENT. THE POSTED ADDRESS RANGE SHALL MEET THE | | | REQUIREMENTS OF THIS SECTION. | | | | | | CONTACT: MICHAEL ORIO GIS SUPPORT SPECIALIST/ | | | INFORMATION TECHNOLOGY | | | TEL: 561-494-1040 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2017-12-11 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2017-12-11 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2017-12-11 |
Time |
10:25 |
Sent To |
|
|
| Notes |
| 2017-12-11 10:27:45 | THE ADDRESS OF 2211 N AUSTRALIAN IS USED FOR TWO | | | BUILDINGS AS SHOWN ON SP 1. | | | | | | ADDRESSING: CITY MUNI CODE SEC.78-6 (1-7) | | | | | | (2) LOCATION, BUILDINGS CONTAINING MORE THAN ONE | | | ADDRESS. ALL ADDRESSES SHALL BE POSTED ON THAT PORTION | | | OF THE STRUCTURE FRONTING OR FACING UPON THE STREET OR | | | PRINCIPAL VEHICULAR ACCESS TO THE PREMISES, SO AS TO BE | | | READILY VISIBLE TO APPROACHING VEHICLES. OWNERS OR | | | TENANTS OF ALL HOUSES AND BUILDINGS USING A SERVICE | | | ALLEY SHALL ALSO POST A NUMBER ON THE SIDE OF THE | | | BUILDINGS ADJACENT TO AND FACING SUCH ALLEY. IF THE | | | HOUSE OR BUILDING IS OBSTRUCTED BY A FENCE, THEN THE | | | NUMBER SHALL BE POSTED ON THE FENCE. THE PLACEMENT OF | | | NUMBERS ON BUILDINGS OR FENCES, AS THE CASE MAY BE, | | | SHALL BE SUBJECT TO THE DIRECTION OR APPROVAL OF THE | | | CITY'S CONSTRUCTION SERVICES DEPARTMENT. BUILDINGS | | | WHICH CONTAIN MORE THAN ONE RESIDENTIAL, COMMERCIAL, | | | INDUSTRIAL, OR INSTITUTIONAL ADDRESS SHALL POST A | | | SEPARATE ADDRESS MEETING THE REQUIREMENTS OF THIS | | | SECTION AT THE EXTERIOR ENTRANCE TO EACH INDIVIDUAL | | | ADDRESS OR COMMON EXTERIOR ENTRANCE TO SEVERAL | | | ADDRESSES THEREIN, AND THE UNIT NUMBER SHALL ALSO BE | | | POSTED ON THE EXTERIOR DOOR OF EACH UNIT SERVED BY SUCH | | | A COMMON EXTERIOR ENTRANCE. | | | | | | (3) MONUMENT SIGNS. ALL MONUMENT SIGNS FOR MULTIPLE | | | RESIDENTIAL, COMMERCIAL, INDUSTRIAL, OR INSTITUTIONAL | | | DEVELOPMENTS SHALL POST THE ADDRESS RANGE FOR THE | | | DEVELOPMENT. THE POSTED ADDRESS RANGE SHALL MEET THE | | | REQUIREMENTS OF THIS SECTION. | | | | | | CONTACT: MICHAEL ORIO GIS SUPPORT SPECIALIST/ | | | INFORMATION TECHNOLOGY | | | TEL: 561-494-1040 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-02-14 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-02-14 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-02-14 |
Time |
07:49 |
Sent To |
|
|
| Notes |
| 2018-03-01 15:17:44 | DEFERRED SUBMITTALS: | | | | | | SHOP DRAWING: | | | RAILING CALCULATIONS | | | METAL STAIR CALCULATIONS | | | METAL CANOPY CALCULATIONS | | | ROOF DRAWINGS | | | HVAC CUT SHEET | | | LOW VOLTAGE DATA AND SECURITY | | | LIGHTING PACKAGE | | | FLOORING UNDERLAYMENT STC/IIC TEST REPORTS | | | FLOORING UNDERLAYMENT GLAME SPREAD REPORTS | | | | | | ROOF PRODUCT APPROVALS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-01-04 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-01-04 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-01-04 |
Time |
08:39 |
Sent To |
|
|
| Notes |
| 2018-01-04 11:32:54 | ****PLAN REVIEW COMMENTS**** | | | | | | ART LANGE BUILDING PLANS EXAMINER | | | | | | DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FL 33402 | | | | | | 561-805-6718 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2014 5TH EDITION W/2010 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION / FRC FLORIDA RESIDENTIAL CODE | | | 2015 5TH EDITION | | | | | | VILLAGE AT MANGONIA LAKE 17111014 3 STORY 12 UNITS | | | | | | SECOND REVIEW: | | | | | | ART IN PUBLIC PLACES | | | | | | 1. RECEIVED ACKNOWLEDGEMENT LETTER. OK | | | | | | PER CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE | | | V, ART IN PUBLIC PLACES, SECTION 78-122, RENOVATION AND | | | NEW CONSTRUCTION PROJECTS ARE ASSESSED CUMULATIVELY, SO | | | THE ART ASSESSMENT WILL BE APPLICABLE TO ALL FUTURE | | | PROJECTS. | | | | | | FOR CONTACT INFORMATION PLEASE CONTACT: | | | MS. SYBILLE WELTER ART IN PUBLIC PLACES COORDINATOR | | | 822-1515 E-MAIL: [email protected] | | | | | | 2. NEW COMMENTS. SINCE YOU HAVE NOT CHOSEN TO USE | | | PRIVATE PROVIDER. PLEASE COMPLETE THE RESIDENT | | | INSPECTOR AGGREEMENT THE MOST UPDATE VERSION IS | | | AVAILABLE AT OUR DEPARTMENT. IF YOU NEED AN ADDITION | | | COPY I CAN EMAIL THE ATTACHMENT TO YOU. | | | | | | PREVIOUS COMMENTS. OWNER HAS ELECTED TO USE PRIVATE | | | PROVIDER FOR INSPECTIONS. I CONTACTED KRYSTAL COURCHENE | | | WITH EPC SERVICES. I EMAILED THE PRIVATE PROVIDER | | | PROCEDURE. | | | PROVIDE REQUIRED DOCUMENTS PER SECTION 553.791 FLORIDA | | | STATUTES AND FLORIDA BUILDING COMMISSION FORM | | | (61G20-2.005-2002-01). | | | | | | 3. OK RECEIVED. | | | PROVIDE SOILS INVESTIGATION REPORT. | | | | | | FBC 1803.1 GEOTECHNICAL INVESTIGATIONS SHALL BE | | | CONDUCTED IN ACCORDANCE WITH SECTION 1803.2 AND | | | REPORTED IN ACCORDANCE WITH SECTION 1803.6. WHERE | | | REQUIRED BY THE BUILDING OFFICIAL OR WHERE GEOTECHNICAL | | | INVESTIGATIONS INVOLVE IN-SITU TESTING, LABORATORY | | | TESTING OR ENGINEERING CALCULATIONS, SUCH | | | INVESTIGATIONS SHALL BE CONDUCTED BY A REGISTERED | | | DESIGN PROFESSIONAL. | | | | | | 4. OK | | | | | | 5. NOT ADDRESSED: | | | | | | PRODUCT APPROVALS: | | | | | | A. NOA 16 0407.10 IS FOR AN OUTSWING DOOR. DOOR ON PLAN | | | IS IN SWING. | | | | | | B. NOA 15 0512.10 CGI SINGLE HUNG WINDOW IS NOT SHOWN | | | ON WINDOW SCHEDULE. | | | | | | NEW COMMENTS: | | | | | | C. DOORS 5 AND 6 ON SCHEDULE NOA 16.0407.09 HAS NOT | | | BEEN PROVIDED. | | | | | | D. NOA FOR GENSTORM INSWING DOOR 17 0130.02 IS NOT ON | | | THE DOOR SCHEDULE. | | | | | | E. ROOFING PRODUCT APPROVAL SHOULD BE SUBMITTED FOR | | | REVIEW PRIOR TO A ROOFING PERMIT BEING ISSUED. | | | | | | 4. OK | | | | | | 5. NEW COMMENTS: | | | | | | PLEASE GO THROUGH DOCUMENTS BEFORE RESUBMITTING. SUBMIT | | | 3 COMPLETE SETS OF DOCUMENTS FOR PERMITTING. REMOVE ANY | | | EXTRA COPIES THAT ARE NOT REQUIRED. | | | | | | FBC 107.1 GENERAL. | | | | | | SUBMITTAL DOCUMENTS CONSISTING OF CONSTRUCTION | | | DOCUMENTS, STATEMENT OF SPECIAL INSPECTIONS, | | | GEOTECHNICAL REPORT AND OTHER DATA SHALL BE SUBMITTED | | | IN TWO OR MORE SETS WITH EACH PERMIT APPLICATION. THE | | | CONSTRUCTION DOCUMENTS SHALL BE PREPARED BY A | | | REGISTERED DESIGN PROFESSIONAL WHERE REQUIRED BY | | | CHAPTER 471, FLORIDA STATUTES OR CHAPTER 481, FLORIDA | | | STATUTES. WHERE SPECIAL CONDITIONS EXIST, THE BUILDING | | | OFFICIAL IS AUTHORIZED TO REQUIRE ADDITIONAL | | | CONSTRUCTION DOCUMENTS TO BE PREPARED BY A REGISTERED | | | DESIGN PROFESSIONAL. | | | | | | | | | | | | WHEN RESUBMITTING, PLEASE COMPLETE A RESUBMITTAL FORM: | | | | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | THIS FORM IS ALSO AVAILABLE AT THE BUILDING DIVISION. | | | | | | WHEN RESUBMITTING, SWAP OUT SHEETS WHICH HAVE CHANGED | | | SO THAT THERE ARE TWO COMPLETE, COLLATED SETS OF PLANS | | | READY FOR PERMIT ISSUANCE. OLD SHEETS ARE TO BE | | | RETAINED IN THE PERMIT APPLICATION PACKAGE (SEPARATE | | | FROM THE PERMIT SETS) AND MARKED *OLD SHEETS* OR | | | *VOID*. PLEASE KEEP BOTH SETS OF OLD VOIDED SHEETS IN | | | THE PERMIT PACKAGE. | | | | | | A RESPONSE LETTER INDICATING HOW EACH ITEM WAS | | | ADDRESSED WILL HELP TO EXPEDITE PLAN REVIEW. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-12-11 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2017-12-11 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2017-12-08 |
Time |
15:08 |
Sent To |
|
|
| Notes |
| 2017-12-11 10:21:03 | ****PLAN REVIEW COMMENTS**** | | | | | | ART LANGE BUILDING PLANS EXAMINER | | | | | | DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FL 33402 | | | | | | 561-805-6718 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2014 5TH EDITION W/2010 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION / FRC FLORIDA RESIDENTIAL CODE | | | 2015 5TH EDITION | | | | | | VILLAGE AT MANGONIA LAKE 17111014 3 STORY 12 UNITS | | | | | | FIRST REVIEW: | | | | | | ART IN PUBLIC PLACES | | | | | | 1. INFORMATION NOTICE: THE CITY OF WEST PALM BEACH ART | | | IN PUBLIC PLACES ORDINANCE REQUIREMENT THAT APPLIES TO | | | ANY REMODEL OR NEW CONSTRUCTION PROJECT FOR WHICH THE | | | PERMIT APPLICATION WAS SUBMITTED AFTER 6/29/14, AND THE | | | TOTAL PROJECT CONSTRUCTION COSTS ARE EQUAL TO OR | | | GREATER THAN $750,000 WILL NEED TO COMPLY WITH THIS | | | ORDINANCE. | | | PER CITY OF WEST PALM BEACH ORDINANCE NO. 4504-14, AND | | | CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE V, | | | ART IN PUBLIC PLACES, SECTION 78-123(A) AND SECTION | | | 78-126(A), THE ART ASSESSMENT IS 1% OF THE TOTAL | | | PROJECT CONSTRUCTION COST. | | | | | | PER CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE | | | V, ART IN PUBLIC PLACES, SECTION 78-122, RENOVATION AND | | | NEW CONSTRUCTION PROJECTS ARE ASSESSED CUMULATIVELY, SO | | | THE ART ASSESSMENT WILL BE APPLICABLE TO ALL FUTURE | | | PROJECTS. | | | | | | FOR CONTACT INFORMATION PLEASE CONTACT: | | | MS. SYBILLE WELTER ART IN PUBLIC PLACES COORDINATOR | | | 822-1515 E-MAIL: [email protected] | | | | | | 2. OWNER HAS ELECTED TO USE PRIVATE PROVIDER FOR | | | INSPECTIONS. I CONTACTED KRYSTAL COURCHENE WITH EPC | | | SERVICES. I EMAILED THE PRIVATE PROVIDER PROCEDURE. | | | PROVIDE REQUIRED DOCUMENTS PER SECTION 553.791 FLORIDA | | | STATUTES AND FLORIDA BUILDING COMMISSION FORM | | | (61G20-2.005-2002-01). | | | | | | 3. PROVIDE SOILS INVESTIGATION REPORT. | | | | | | FBC 1803.1 GEOTECHNICAL INVESTIGATIONS SHALL BE | | | CONDUCTED IN ACCORDANCE WITH SECTION 1803.2 AND | | | REPORTED IN ACCORDANCE WITH SECTION 1803.6. WHERE | | | REQUIRED BY THE BUILDING OFFICIAL OR WHERE GEOTECHNICAL | | | INVESTIGATIONS INVOLVE IN-SITU TESTING, LABORATORY | | | TESTING OR ENGINEERING CALCULATIONS, SUCH | | | INVESTIGATIONS SHALL BE CONDUCTED BY A REGISTERED | | | DESIGN PROFESSIONAL. | | | | | | 4. NOTE: ON PAGE A 6.3 THE CLEAR FLOOR SPACE BETWEEN | | | THE TUB AND DOOR IS EXACTLY AT THE MINIMUM. NO ACTION | | | REQUIRED. | | | | | | 5. PRODUCT APPROVALS | | | | | | A. NOA 16 0407.10 IS FOR AN OUTSWING DOOR. DOOR ON PLAN | | | IS IN SWING. | | | | | | B. NOA 15 0512.10 CGI SINGLE HUNG WINDOW IS NOT SHOWN | | | ON WINDOW SCHEDULE. | | | | | | 4. ACCESSIBLE PARKING SIGNAGE SHOWN ON C 13 SHOULD BE | | | UPDATED TO REFLECT A MINIMUM OF 60 INCHES. | | | SEE FS CHANGE 553.5041 (6) | | | | | | | | | WHEN RESUBMITTING, PLEASE COMPLETE A RESUBMITTAL FORM: | | | | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | THIS FORM IS ALSO AVAILABLE AT THE BUILDING DIVISION. | | | | | | WHEN RESUBMITTING, SWAP OUT SHEETS WHICH HAVE CHANGED | | | SO THAT THERE ARE TWO COMPLETE, COLLATED SETS OF PLANS | | | READY FOR PERMIT ISSUANCE. OLD SHEETS ARE TO BE | | | RETAINED IN THE PERMIT APPLICATION PACKAGE (SEPARATE | | | FROM THE PERMIT SETS) AND MARKED *OLD SHEETS* OR | | | *VOID*. PLEASE KEEP BOTH SETS OF OLD VOIDED SHEETS IN | | | THE PERMIT PACKAGE. | | | | | | A RESPONSE LETTER INDICATING HOW EACH ITEM WAS | | | ADDRESSED WILL HELP TO EXPEDITE PLAN REVIEW. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2017-12-11 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-12-11 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-12-11 |
Time |
08:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2017-12-13 |
|
|
Cont ID |
|
| Sent By |
squinone |
Date |
2017-12-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
squinone |
Date |
2017-12-13 |
Time |
|
Sent To |
|
|
| Notes |
| 2017-12-13 15:45:33 | NO CIVIL PLANS WERE INCLUDED WITH THIS SUBMITTAL. CIVIL | | | PLANS ARE UNDER REVIEW THROUGH ENGINEERING PLAN REVIEW, | | | E17060013. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-01-05 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2018-01-05 |
Time |
09:56 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2018-01-05 |
Time |
09:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2017-11-29 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2017-11-29 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2017-11-29 |
Time |
15:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2018-03-01 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-03-01 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-02-27 |
Time |
14:12 |
Sent To |
|
|
| Notes |
| 2018-02-28 14:12:11 | RESUB ROUTED TO ACLANGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-02-14 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-02-14 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-01-23 |
Time |
13:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-01-22 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-01-22 |
Time |
12:51 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-01-02 |
Time |
13:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-12-16 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-12-16 |
Time |
07:11 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-11-28 |
Time |
09:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
P |
Date |
2018-03-01 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-03-01 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-03-01 |
Time |
15:04 |
Sent To |
|
|
| Notes |
| 2018-03-01 15:28:33 | PALM BEACH COUNTY IMPACT FEES PAID | | | 2/20/18 | | | MU2018-5454 | | | $85,762.20 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2018-02-14 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-02-14 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-02-14 |
Time |
07:50 |
Sent To |
|
|
| Notes |
| 2018-02-14 10:22:20 | IMPACT FEES: | | | | | | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2018-01-04 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-01-04 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-01-04 |
Time |
10:25 |
Sent To |
|
|
| Notes |
| 2018-01-04 10:25:17 | IMPACT FEES: | | | | | | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2017-12-11 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2017-12-11 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2017-12-11 |
Time |
10:24 |
Sent To |
|
|
| Notes |
| 2017-12-11 10:24:48 | | | | IMPACT FEES: | | | | | | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2018-02-06 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-02-06 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-02-06 |
Time |
10:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2018-01-11 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-01-11 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-01-11 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2018-01-11 16:30:23 | 2ND REVIEW FBC-2014 MECHANICAL, ENERGY CONSERVATION | | | CODE | | | PERMIT #17111014 | | | 1/11/18 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) AC CALCULATIONS: PLEASE PROVIDE ADDITIONAL "PROJECT | | | INFORMATION" IN THE NOTES SECTION IDENTIFTYING ALL OF | | | THE 12 APARTMENTS INCLUDED IN THE CALCULATIONS, AND | | | WHICH APARTMENT ON WAS USED AS THE BASE MODEL FOR THE | | | MULTIPLE ORIENTATION CALCULATIONS. WAS THE APARTMENT ON | | | THE 1ST, 2ND, OR 3RD LEVEL? DO THE MULTIPLE | | | ORIENTATIONS PERTAIN TO ALL 3 LEVELS? | | | | | | 2) SHEETS M-1 & M-2: PLEASE REMOVE OR CORRECT ALL THE | | | NOTES THAT ARE SPECIFYING PVC CONDENSATE PIPING IN THE | | | AC CLOSETS. REFER TO SECTIONS R403.2.2 FBC-14 ENERGY | | | CONSERVATION AND SECTION 602.2.1 FBC-14 MECHANICAL- PVC | | | IS COMBUSTIBLE AND NOT PERMITTED IN THE AC CLOSETS. | | | PLEASE NOTE THAT IS IS SPECIFIED AS COPPER (CU) IN THE | | | AIR HANDLER DETAIL ON M-3. | | | | | | 3) SHEET A-7.1: PLEASE CLARIFY HOW THE AC CLOSET WOOD | | | DOOR IS ALSO SPECIFIED AS "NON-COMBUSTIBLE" IN THE | | | SCHEDULE. REFER TO THE CODE SECTIONS LISTED IN COMMENT | | | #2. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-12-12 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-12-12 |
Time |
17:40 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-12-12 |
Time |
17:01 |
Sent To |
|
|
| Notes |
| 2017-12-12 17:53:42 | 1ST REVIEW FBC-2014 MECHANICAL AND FBC-14RESIDENTIAL | | | ENERGY CODE | | | PERMIT #1711014 | | | 12/12/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE COOLING AND HEATING CALCULATIONS FOR THE AC | | | SYSTEMS- SECTION R403.6.1 FBC-14 ENERGY CONSERVATION | | | | | | 2) THE 718 TOTAL SQUARE FOOTAGE LISTED ON PAGE 1 OF THE | | | ENERGY EFFICIENCY FORM R405-2014 INDICATES THE | | | COMPLIANCE REPORT IS FOR ONLY ONE OF THE 12 APARTMENTS. | | | COMPLIANCE FOR THE ENTIRE BUILDING IS REQUIRED PER | | | SECTION R101.2 FBC-14 ENERGY CONSERVATION | | | | | | 3) THE OWNER/AGENT SHALL SIGN AND DATE THE ENERGY FORM | | | R405-2014 AS REQUIRED BY SECTION R103.1.1.2 FBC-14 | | | ENERGY CONSERVATION. | | | | | | 4) MANDATORY BLOWER DOOR TESTING IS REQUIRED PER | | | SECTION R402.4.1.2. PLEASE PLACE A NOTE ON THE PLANS | | | ACCORDINGLY. | | | | | | 5) AC STAND NOA #15-0902.05: THE ENGINEER OF RECORD | | | SHALL CIRCLE, HIGHLIGHT, OR OTHERWISE MARK ALL DETAILS, | | | NOTES, DESIGN PRESSURES ETC. THAT PERTAIN TO THE | | | PROPOSED ROOFTOP AC INSTALLATIONS. | | | | | | 6) M1: EXHAUST VENTILATION AT A RATE OF 25 CFMS | | | CONTINUOUSLY OR 100 CFMS INTERMITTENTLY IS REQUIRED FOR | | | THE KITCHENS- SEE TABLE 403.3 | | | | | | 7) M1: AUTO-CONTROLLED SHUT OFF DAMPERS ARE REQUIRED | | | FOR THE OUTDOOR AIR SUPPLY DUCTS- SECTION C403.2.44 | | | FBC-14 ENERGY CONSERVATION. PLEASE SHOW THE LOCATION OF | | | THE DAMPERS AND PROVIDE A PRODUCT DATA SHEET THAT | | | INDICATES COMPLIANCE WITH SECTION C402.4.5.2. | | | | | | 8) SUBMIT A FLORIDA PRODUCT APPROVAL OR A MIAMI-DADE | | | NOA FOR THE THE WALL CAPS. IN LIEU OF STATE APPROVAL, | | | MANUFACTURER'S SPECIFICATIONS MAY BE SUBMITTED THAT | | | INDICATE THE PRODUCT IS COMPLIANT WITH SECTION 401.5 | | | | | | CHRISTOPHER L. COLE | | | BUILDING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2018-02-13 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-02-13 |
Time |
07:38 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-02-12 |
Time |
15:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2018-01-19 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-01-19 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-01-19 |
Time |
15:27 |
Sent To |
|
|
| Notes |
| 2018-01-19 15:34:24 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. PLEASE PROVIDE DETAILS FOR MOUNTING THE BACKING FOR | | | THE GRAB BARS IN THE BATHROOMS.AS SHOWN IN THE FHA | | | DESIGN MANUAL REQUIREMENT #6 PG. 6.3, 6.4, 6.8, 6.9, | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-12-14 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-12-14 |
Time |
18:58 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-12-14 |
Time |
15:00 |
Sent To |
|
|
| Notes |
| 2017-12-14 19:11:47 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. PROVIDE DIMENSION BETWEEN THE TUB AND CENTER OF | | | WATER CLOSET, 18" ABSOLUTE IS REQUIRED. PER FHA DESIGN | | | MANUAL REQUIREMENT 7 PG. 7.43 | | | | | | 2. PLEASE SHOW CLEAR FLOOR SPACE FOR THE WATER CLOSETS. | | | PER FHA DESIGN MANUAL REQUIREMENT 7 PG. 7.43 | | | | | | 3. SHT. A-6.3 DETAIL #3(B) WHAT IS THE DIMENSION OF | | | 1'4" FOR PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 4. PROVIDE DIMENSION FOR DEPTH OF VANITY , MAX 24" PER | | | PER FHA DESIGN MANUAL REQUIREMENT 7 PG. 7.43. 7.44 | | | | | | 5. PLEASE PROVIDE A DETAIL FOR THE EMERGENCY OVERFLOW | | | SCUPPER SHOWING THE DIMENSION FROM THE LOWEST POINT OF | | | THE ROOF AND THE BOTTOM OF THE SCUPPER. PER FBC PL | | | 1101.7 | | | | | | 6. IN THE AC CLOSETS WHAT TYPE OF PIPE WILL BE USED FOR | | | THE PAN DRAIN AND THE CONDENSATE DRAIN. PER WPB AMEND | | | TO FBC 107.2.1 | | | | | | 7. PLEASE CHANGE THE NOTE ON THE PLAN ON THE WATER | | | RISER PAGE TO READ THE MANUFACTURE SPECIFICATION FOR | | | THE SUBMETER SHALL BE PROVIDED PRIOR TO INSPECTION. PER | | | WPB AMEND TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2018-03-01 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-03-01 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-03-01 |
Time |
15:13 |
Sent To |
|
|
| Notes |
| 2018-03-01 15:13:56 | DEFERRED SUBMITTAL, REQUIRED FOR ROOFING PERMIT |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-01-04 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-01-04 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-01-04 |
Time |
10:26 |
Sent To |
|
|
| Notes |
| 2018-01-04 10:31:41 | ****PLAN REVIEW COMMENTS**** | | | | | | ART LANGE BUILDING PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FL 33402 | | | 561-805-6718 [email protected] | | | | | | PROVIDE ROOFING PRODUCT APPROVALS ALONG WITH THE | | | ROOFING CALCULATIONS. | | | |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
2 |
Status |
P |
Date |
2018-03-01 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-03-01 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-03-01 |
Time |
15:08 |
Sent To |
|
|
| Notes |
| 2018-03-01 15:09:22 | PRIVATE PROVIDER DOCUMENTS ALREADY ON FILE AND APPROVED | | | FOR THIS PROJECT. |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
1 |
Status |
F |
Date |
2018-02-14 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-02-14 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-02-14 |
Time |
07:50 |
Sent To |
|
|
| Notes |
| 2018-02-14 10:21:20 | ****PLAN REVIEW COMMENTS**** | | | | | | ART LANGE BUILDING PLANS EXAMINER | | | | | | DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FL 33402 | | | | | | 561-805-6718 [email protected] | | | | | | | | | 1. THIS BUILDING MEETS THE DEFINITION OF: THRESHOLD | | | BUILDING F.S. 553.71 (12) | | | ?THRESHOLD BUILDING? ANY BUILDING WHICH IS GREATER THAN | | | (3) STORIES OR 50 FT. IN HEIGHT OR WHICH HAS AN | | | ASSEMBLY OCCUPANCY CLASSIFICATION AS DEFINED IN THE | | | FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ. FT. IN | | | AREA AND HAS AN OCCUPANT CONTENT OF GREATER THAN 500 | | | PERSONS. | | | | | | I EMAILED MARIA DIAZ FROM AHS RESIDENTIAL A COPY OF THE | | | THRESHOLD INSPECTOR AGREEMENT ON 2/13/18. | | | | | | 2. SINCE ALL OF THE STRUCTURAL AND M,E,P INSPECTIONS | | | WILL BE COMPLETED BY GFA FROM START TO PROJECT | | | COMPLETION THIS WILL ALSO BE A PRIVATE PROVIDER PROJECT | | | ONCE THE THRESHOLD INSPECTIONS ARE COMPLETED. | | | CLEARLY SHOW ON THE THRESHOLD AND PRIVATE PROVIDER | | | APPLICATIONS THE SCOPE OF INSPECTIONS TO BE COMPLETED | | | FOR EACH PROJECT. | | | | | | A. WHEN A FEE OWNER OR THE FEE OWNER?S CONTRACTOR | | | ELECTS TO USE A PRIVATE PROVIDER FOR INSPECTION | | | SERVICES ONLY, IT IS BEST TO SUBMIT THE ?NOTICE TO | | | BUILDING OFFICIAL? FORM (61G20-2.005-2002-01) AT TIME | | | OF PERMIT APPLICATION. WHEN THE ?NOTICE TO BUILDING | | | OFFICIAL? IS NOT SUBMITTED AT PERMIT APPLICATION, IT | | | MUST BE SUBMITTED NO LESS THAN 7 BUSINESS DAYS PRIOR TO | | | THE FIRST SCHEDULED INSPECTION PER 553.791 (4). THE FEE | | | OWNER OR CONTRACTOR MUST SUBMIT THE ?NOTICE TO BUILDING | | | OFFICIAL? TO THE BUILDING DIVISION. DEVELOPMENT | | | SERVICES. THE LICENSE AND PERMIT SPECIALISTS SHALL THEN | | | DIRECT THE ?NOTICE TO BUILDING OFFICIAL? TO AN | | | ASSISTANT BUILDING OFFICIAL TO REVIEW THE STATUS OF THE | | | FORM. | | | | | | B. THE ASSISTANT BUILDING OFFICIAL SHALL REVIEW THE | | | APPLICANT'S SUBMITTAL FOR COMPLIANCE WITH FS 553.791; | | | AND SHALL VERIFY THAT "NOTICE TO THE BUILDING OFFICIAL? | | | OF USE OF PRIVATE PROVIDER (61G20-2.005-2002-01) HAS | | | BEEN PROPERLY FILLED OUT, ALL QUALIFICATION STATEMENTS | | | AND RESUMES ARE COMPLETE, AND PROOF OF INSURANCE AS | | | OUTLINED IN 553.791 (16) HAVE BEEN SUBMITTED. | | | | | | 3. THE CONSTRUCTION COST FOR THIS PROJECT IS OVER $5 | | | MILLION. PRIVATE PROVIDER SHALL HAVE A MINIMUM POLICY | | | LIMIT OF $2 MILLION PER OCCURRENCE AND $4 MILLION IN | | | THE AGGREGATE. FS 553.791 (16). | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-02-02 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2018-01-30 |
Time |
16:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-01-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2018-01-19 |
Time |
08:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
PG |
Date |
2017-12-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2017-12-12 |
Time |
09:29 |
Sent To |
|
|
| Notes |
|
|