Plan Review Details - Permit 17110975
Plan Review Stops For Permit 17110975
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-12-22 Cont ID  
Sent By cthroop Date 2017-12-22 Time 12:43 Rev Time 0.00
Received By cthroop Date 2017-12-22 Time 12:43 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-12-07 Cont ID  
Sent By cthroop Date 2017-12-07 Time 13:44 Rev Time 0.00
Received By cthroop Date 2017-12-07 Time 13:43 Sent To  
Notes
2017-12-07 13:47:57BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE SITE PLAN. SHOW SETBACKS TO PROPERTY LINES
 AND OTHER STRUCTURES ON SITE.
 2. INDICATE ON PLANS WHICH FOUNDATION/ATTACHMENT SYSTEM
 WILL BE USED.
 3. PROVIDE 2ND SET OF PLANS.
  
 FBC 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS.
 THE EXAMINATION OF THE DOCUMENTS BY THE BUILDING
 OFFICIAL SHALL INCLUDE THE FOLLOWING MINIMUM CRITERIA
 AND DOCUMENTS: A FLOOR PLAN; SITE PLAN; FOUNDATION
 PLAN; FLOOR/ROOF FRAMING PLAN OR TRUSS LAYOUT; ALL
 FENESTRATION PENETRATIONS; FLASHING; AND ROUGH OPENING
 DIMENSIONS; AND ALL EXTERIOR ELEVATIONS:
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN
 UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE
 OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT
 IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 FBC107.1 GENERAL. SUBMITTAL DOCUMENTS CONSISTING OF
 CONSTRUCTION DOCUMENTS, STATEMENT OF SPECIAL
 INSPECTIONS, GEOTECHNICAL REPORT AND OTHER DATA SHALL
 BE SUBMITTED IN TWO OR MORE SETS WITH EACH PERMIT
 APPLICATION.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-12-22 Cont ID  
Sent By cthroop Date 2017-12-22 Time 12:43 Rev Time 0.00
Received By cthroop Date 2017-12-12 Time 11:11 Sent To I
Notes
2017-12-13 11:12:05RESUB ROUTED TO AJONES VIA ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-12-07 Cont ID  
Sent By cthroop Date 2017-12-07 Time 13:48 Rev Time 0.00
Received By cthroop Date 2017-11-27 Time 13:15 Sent To I
Notes
2017-11-28 13:15:29ROUTED TO ZONING

Review Stop Z ZONING
Rev No 2 Status P Date 2017-12-22 Cont ID  
Sent By ajones Date 2017-12-22 Time 10:15 Rev Time 0.00
Received By ajones Date 2017-12-14 Time 14:53 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date   Cont ID  
Sent By AW Date 2017-12-05 Time   Rev Time 0.00
Received By ajones Date 2017-11-30 Time 14:44 Sent To B
Notes
2017-12-05 14:35:48********************************ZONING REVIEW
 FAILED***************************************
  
 SHEDS REQUIRED A MINIMUM FIVE FOOT SETBACK FROM THE
 SIDE AND REAR PROPERTY LINES. PLEASE INDICATE SIDE AND
 REAR SETBACK FOR SHED ON THE SURVEY.
  
 THANKS,
 ALANA WOOTEN
 ASSOCIATE PLANNER
 PLANNING DIVISION
 561-822-1449
 [email protected]


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved