Plan Review Details - Permit 17110868
Plan Review Stops For Permit 17110868
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-01-10 Cont ID  
Sent By cthroop Date 2018-01-10 Time 15:46 Rev Time 0.00
Received By cthroop Date 2018-01-10 Time 15:16 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-12-14 Cont ID  
Sent By cthroop Date 2017-12-14 Time 14:17 Rev Time 0.00
Received By cthroop Date 2017-12-14 Time 14:17 Sent To  
Notes
2017-12-14 14:20:07BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE ATTACHMENT DETAIL FOR PROPOSED LETTERING.
 2. IF LETTERING IS 3 DEMENSIONAL, PROVIDE DESIGN WIND
 LOADS PER FBC CHPT. 16.
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN
 UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE
 OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT
 IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 FBC 107.3.5.1.1(8) - PROVIDE WIND DESIGN LOADS/DESIGN
 PRESSURES PURSUANT TO FBC-CHAPTER 16
  
 1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE
 STRUCTURE:
 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST),
 MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED,
 VASD, AS DETERMINED IN ACCORDANCE WITH SECTION
 1609.3.1.
 2. RISK CATEGORY.
 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE
 THAN ONE WIND EXPOSURE IS UTILIZED.
 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT.
 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY
 DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL
 RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/
 M2).
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-01-10 Cont ID  
Sent By cthroop Date 2018-01-10 Time 15:46 Rev Time 0.00
Received By cthroop Date 2018-01-03 Time 13:52 Sent To I
Notes
2018-01-04 13:52:36RESUB ROUTED TO AJONES VIA ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-12-14 Cont ID  
Sent By cthroop Date 2017-12-14 Time 14:20 Rev Time 0.00
Received By cthroop Date 2017-11-21 Time 10:55 Sent To I
Notes
2017-11-22 10:56:05ROUTED TO ZONING

Review Stop Z ZONING
Rev No 2 Status P Date 2018-01-10 Cont ID  
Sent By AW Date 2018-01-10 Time 09:20 Rev Time 0.00
Received By awooten Date 2018-01-09 Time 12:11 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date   Cont ID  
Sent By AW Date   Time   Rev Time 0.00
Received By ajones Date 2017-11-27 Time 16:15 Sent To B
Notes
2017-12-08 14:32:28********ZONING REVIEW FAILED**********
  
 THE PEMITTED SQUARE FOOTAGE FOR WALL SIGNS IS BASED ON
 THE SQUARE FOOTAGE OF THE BUILDING FACADE. PLEASE
 PROVIDE THE SQUARE FOOTAGE FOR THE FRONT FACADE OF THE
 BUILDING ELEVATION WHERE THE EACH SIGN IS TO BE
 LOCATED. PLEASE LET ME KNOW WHAT QUESTIONS YOU MAY
 HAVE. FURTHER COMMENTS MAY FOLLOW.
  
 ALANA WOOTEN
 ASSOCIATE PLANNER
 PLANNING DIVISION
 561-822-1449
 [email protected]