Plan Review Details - Permit 17110812
Plan Review Stops For Permit 17110812
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-01-23 Cont ID  
Sent By jwitmer Date 2018-01-23 Time 12:27 Rev Time 0.00
Received By jwitmer Date 2018-01-23 Time 11:54 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-12-06 Cont ID  
Sent By jwitmer Date 2017-12-06 Time 10:23 Rev Time 0.00
Received By jwitmer Date 2017-12-06 Time 07:28 Sent To  
Notes
2017-12-06 09:22:03BUILDING PLAN REVIEW
 W. P. B. REVISION: 17110812
 W. P. B. PERMIT: 16010290
 ADD: 805 N. RAILROAD AVE.
 CONT: PALM BEACH CAST STONE
 TEL: 561-835-4085
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. DEC. 06/2017
 ACTION: DENIED
  
 1) THE ORIGINAL APPROVED SET OF PLANS WITH THE
 ARCHITECTS DATE STAMP OF 09/06/ 2016 SHOWS A MAXIMUM
 DIFFERENCE IN HEIGHT OF 1/2 INCH DIFFERENCE IN HEIGHT.
 IT DOES STATE ON THE PLANS TO COORDINATE SIDEWALK
 REPLACEMENT WITH THE CITY OF WEST PALM BEACH PUBLIC
 WORKS DEPARTMENT. RAISED CONCRETE SIDEWALK TO WITHIN
 1/2 INCH OF THE 1ST FLOOR ELEVATION (+/- 4 INCHES) SEE
 DETAIL.
  
 CREATION OR EXTENSION OF NONCONFORMITY.
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING. CREATION OR EXTENSION
 OF NONCONFORMITY. ALL NEW WORK, RE-CONFIGURATION SHALL
 NOT CREATE OR EXTEND ANY NONCONFORMITY IN THE EXISTING
 BUILDING TO WHICH THE RE-CONFIGURATION OF SPACE IS
 BEING MADE WITH REGARD TO ACCESSIBILITY, STRUCTURAL
 STRENGTH, FIRE SAFETY, MEANS OF EGRESS, OR THE CAPACITY
 OF MECHANICAL, PLUMBING, OR ELECTRICAL SYSTEMS.
  
 UNDER THE 2014 THE 1ST ITEM UNDER ACCESSIBILITY 202.4.1
 DISPROPORTIONATE COST IS AN ACCESSIBLE ENTRANCE. WHEN
 THE COST OF ALTERATIONS NECESSARY TO MAKE THE PATH OF
 TRAVEL TO THE ALTERED AREA FULLY ACCESSIBLE IS
 DISPROPORTIONATE TO THE COST OF THE OVERALL ALTERATION,
 THE PATH OF TRAVEL SHALL BE MADE ACCESSIBLE TO THE
 EXTENT THAT IT CAN BE MADE ACCESSIBLE WITHOUT INCURRING
 DISPROPORTIONATE COSTS. IN CHOOSING WHICH ACCESSIBLE
 ELEMENTS TO PROVIDE, PRIORITY SHOULD BE GIVEN TO THOSE
 ELEMENTS THAT WILL PROVIDE THE GREATEST ACCESS, IN THE
 FOLLOWING ORDER: (I) AN ACCESSIBLE ENTRANCE;
  
 2) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-02-07 Cont ID  
Sent By jpearson Date 2018-02-07 Time 15:26 Rev Time 0.00
Received By jpearson Date 2018-02-07 Time 15:26 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-12-07 Cont ID  
Sent By jpearson Date 2017-12-07 Time 16:25 Rev Time 0.00
Received By jpearson Date 2017-12-07 Time 16:25 Sent To  
Notes
2017-12-07 16:25:27CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION
 NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. A DISCREPANCY EXIST FOR PANEL B1. THE PANEL SCHEDULE
 STATES THAT IT IS SINGLE PHASE, BUT THE FEEDERS TO THE
 PANEL ARE FOR 3 PHASE, AS WELL AS THE BREAKER FEEDING
 THIS PANEL. CLARIFY AND/OR CORRECT. FBC 107.2.1
 2. PROVIDE ACCURATE LOAD CALCULATION FOR PANEL B. PHASE
 B OF THE LOAD CALC SHOWS RECEPTACLE LOADS, WHICH WOULD
 NOT BE ON THE HIGH LEG OF THE SYSTEM. NEC 220; FBC
 107.2.1
 3. FIRST FLOOR POWER PLAN SHOWS A SHUNT TRIP INSTALLED
 ADJACENT TO THE METER CAN, BUT THE RISER SHOWS THIS AS
 A FUTURE INSTALLMENT. CLARIFY AND/OR CORRECT. FBC
 107.2.1
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2018-01-19 Cont ID  
Sent By pleduc Date 2018-01-19 Time   Rev Time 0.00
Received By pleduc Date 2018-01-19 Time 12:00 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2017-11-22 Cont ID  
Sent By pleduc Date 2017-11-22 Time   Rev Time 0.00
Received By pleduc Date 2017-11-22 Time 12:28 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2018-03-19 Time   Rev Time 0.00
Received By lmarchan Date 2018-03-13 Time 15:30 Sent To  
Notes
2018-03-14 15:30:34RESUB ROUTED TO CCOLE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-03-06 Cont ID  
Sent By ajones Date 2018-03-06 Time 09:55 Rev Time 0.00
Received By ajones Date 2018-01-16 Time 14:20 Sent To  
Notes
2018-01-17 14:20:51C19

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-01-03 Cont ID  
Sent By lmarchan Date 2018-01-03 Time 16:10 Rev Time 0.00
Received By lmarchan Date 2017-11-20 Time 14:20 Sent To  
Notes
2017-11-21 14:21:12C11

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2018-03-19 Cont ID  
Sent By ccole Date 2018-03-19 Time 17:32 Rev Time 0.00
Received By ccole Date 2018-03-19 Time 17:32 Sent To I
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2018-01-31 Cont ID  
Sent By ccole Date 2018-01-31 Time 10:56 Rev Time 0.00
Received By ccole Date 2018-01-31 Time 10:56 Sent To  
Notes
2018-01-31 11:01:431ST REVIEW FBC-2014 MECHANICAL
 PERMIT #17110812
 1/31/18
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE AIR HANDLER PERFORMANCE DATA SUBMITTED IS FOR A
 TRANE UNIT, HOWEVER THE AC PLANS ARE SPECIFYING A
 CARRIER SYSTEM. PLEASE PROVIDE THE CORRECT DATA.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-11-30 Cont ID  
Sent By ccole Date 2017-11-30 Time 07:23 Rev Time 0.00
Received By ccole Date 2017-11-30 Time 07:16 Sent To  
Notes
2017-11-30 07:41:511ST REVIEW FBC-2014 MECHANICAL
 REVISION #17110812
 MASTER PERMIT #16010290
 11/30/17
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE CITY OF WEST PALM BEACH BUILDING DEPARTMENT
 REQUIRES A SMOKE DETECTOR IN THE RETURN AIR SYSTEM OF
 AHU-2- SECTION 606.2.1. PLEASE NOTE THAT AN EXEMPTION
 CAN BE APPLIED IF THE MANUFACTURER'S SPECIFICATIONS
 INDICATE THE SYSTEM IS NOT CAPABLE OF PRODUCING OVER
 2000 CFMS OF SUPPLY AIR.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2018-02-07 Cont ID  
Sent By gjohnson Date 2018-02-07 Time 12:04 Rev Time 0.00
Received By gjohnson Date 2018-02-07 Time 12:04 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-12-14 Cont ID  
Sent By gjohnson Date 2017-12-14 Time 11:49 Rev Time 0.00
Received By gjohnson Date 2017-12-14 Time 11:49 Sent To  
Notes
2017-12-14 11:55:241ST REVIEW: FBC 2014 5TH EDITION
  
 PLUMBING COMMENTS:
  
 1. SHT. A4.2 IF THE SHOWER HAS BEEN ELIMINATED FROM THE
 JOB PLEASE REMOVE DETAIL #7 FOR THE SHOWER PAN AND ANY
 OTHER REFERENCE TO THE SHOWER. PER WPB AMEND TO FBC
 107.2.1
  
 2. SHT. P0.1 IN THE PLUMBING FIXTURE SPECIFICATIONS
 PLEASE REMOVE THE SHOWER SET. PER WPB AMEND TO FBC
 107.2.1
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 2018-03-06 Cont ID  
Sent By AA Date 2018-03-06 Time 09:55 Rev Time 0.00
Received By ajones Date 2018-02-13 Time 12:06 Sent To PC
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2018-01-03 Cont ID  
Sent By kmartin Date 2018-01-03 Time   Rev Time 0.00
Received By kmartin Date 2018-01-03 Time 16:08 Sent To  
Notes
***NONE***