Plan Review Details - Permit 17110755
Plan Review Stops For Permit 17110755
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-02-07 Cont ID  
Sent By cthroop Date 2018-02-07 Time 08:29 Rev Time 0.00
Received By cthroop Date 2018-02-06 Time 17:15 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-01-03 Cont ID  
Sent By cthroop Date 2018-01-03 Time 11:37 Rev Time 0.00
Received By cthroop Date 2017-12-27 Time 16:35 Sent To  
Notes
2018-01-03 11:39:49BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. OWNER/AGENT TO SIGN ENERGY SUBMITTAL.
  
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-02-05 Cont ID  
Sent By jpearson Date 2018-02-05 Time 15:53 Rev Time 0.00
Received By jpearson Date 2018-02-05 Time 15:53 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-12-13 Cont ID  
Sent By jpearson Date 2017-12-13 Time 11:09 Rev Time 0.00
Received By jpearson Date 2017-12-13 Time 11:09 Sent To  
Notes
2017-12-13 11:09:11CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION
 NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PLAN SHOWS STANDARD RECESS LIGHTS IN CLOSETS. PER
 CODE: "LIGHTING WITH OPEN OR PARTIALLY ENCLOSED LAMPS
 AND PENDANT LUMINAIRES OR LAMPHOLDERS SHALL NOT BE
 PERMITTED IN CLOTHES CLOSETS". PROVIDE CORRECTION. NEC
 410.16; FBC RE4003.12
 2. PROVIDE GFCI PROTECTION FOR POOL PUMP AND POOL SPA
 PUMP, WHERE APPLICABLE. NEC 680.21(C), 680.44; FBC RE
 4203.1.3, 4208.1
 3. NOTE 2 ON SHEET E-002 REFERENCES THE 2008 NEC, WHICH
 IS NOT THE CURRENT CODE. PROVIDE CORRECTION. FBC
 PREFACE, 2011 NEC
 4. BE ADVISED THAT FIRE ALARM, LOW VOLTAGE SYSTEMS,
 LIGHTNING PROTECTION, GENERATORS, COMMERCIAL HOOD
 SYSTEMS, SIGNS, SITE LIGHTING, AND SWIMMING POOLS
 (WHERE APPLICABLE) ARE NOT INCLUDED IN THE SCOPE OF
 THIS PLAN REVIEW. PROVIDE A BLOCK NOTE INDICATING THE
 REQUIRED SEPARATE PERMITS AND DATA SPECIFICATION SHEET
 SUBMITTALS FOR ANY OF THESE SYSTEMS PRESENT. FBC 105.1,
 107.2.1
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2018-02-07 Cont ID  
Sent By thunt Date 2018-02-07 Time 14:02 Rev Time 0.00
Received By thunt Date 2018-02-07 Time 13:02 Sent To I
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2017-11-28 Cont ID  
Sent By thunt Date 2017-11-28 Time 15:33 Rev Time 0.00
Received By thunt Date 2017-11-28 Time 15:33 Sent To  
Notes
2017-11-28 15:37:2311-28-2017 GAS 1ST REVIEW**DENIED**
  
 1) SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE 2014
 FBC-FUEL GAS CODE SEC.304.1, 614.5 (CLOTHES DRYERS) OR
 2014 FBC-RES. SEC. G 2407.1 AND G2439.4 (CLOTHES
 DRYERS).
  
 2) SUBMIT MANUFACTURER?S SPECIFICATION SHEETS /
 INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO VERIFY
 COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND
 FBC-2014 FUEL GAS CODE SEC. 402.2, AND 301.3 OR 2014
 FBC-RES. SEC. G2404.3. GAS APPLIANCES SHALL BE LISTED
 AND LABELED. THE INSTALLATION MANUALS FOR ALL GAS
 APPLIANCES / EQUIPMENT SHALL BE ONSITE AT THE TIME OF
 INSPECTION. FGC SEC.305.1, FBC-RES. SEC.G2408.1
  
 3) SUBMIT TWO COPIES OF THE APPLICABLE SIZING TABLES
 USED TO SIZE THE GAS SYSTEM OR PLACE A NOTE ON THE
 PLANS/DRAWINGS SPECIFYING WHICH SIZING TABLE(S) FROM
 THE GAS CODE OR OTHER STANDARD THAT WERE USED IN THE
 DESIGN OF THIS GAS SYSTEM. REFER TO THE 2014 FBC-FUEL
 GAS SECS. 401.4, 401.8 THRU 402.6.1 AND TABLES 402.4
 (1) THRU 402.4 (37) OR 2014 FBC-RES. SEC. G2412.4,
 G2412.8, G2413.1, G2413.2, & G2413.3
  
 4) ) SHOW THE LOCATION OF ALL MP (STEP-DOWN)
 REGULATORS. A LISTED SHUTOFF VALVE SHALL BE INSTALLED
 IMMEDIATELY AHEAD OF EACH MP REGULATOR. FBC-FUEL GAS
 SEC.409.4, FBC-RESIDENTIAL SEC. G 2420.4. I
  
 5) SUBMIT MANUFACTURER?S SPECIFICATIONS FOR THE
 PRESSURE REGULATORS. REGULATORS INSTALLED ON THE
 EXTERIOR OF THE BUILDING SHALL BE APPROVED FOR OUTDOOR
 INSTALLATION. 2014 FGC SEC.410.1
  
 6) SHOW THE DISTANCE FROM THE 2 PSI REGULATOR TO THE
 APPLIANCE. COMPLY WITH 2014 FBC-FUEL GAS TABLE 402.4
 (28) FOR THE PROPER PIPE SIZE AND BTU LOAD
  
 TIM HUNT
 PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER
 CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 561-805-6695
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-02-07 Cont ID  
Sent By thunt Date 2018-02-07 Time 14:02 Rev Time 0.00
Received By thunt Date 2018-01-12 Time 14:20 Sent To I
Notes
2018-01-16 14:20:50R23

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-01-03 Cont ID  
Sent By cthroop Date 2018-01-03 Time 11:39 Rev Time 0.00
Received By cthroop Date 2017-11-17 Time 14:01 Sent To I
Notes
2017-11-20 14:01:34R23

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2018-02-07 Cont ID  
Sent By cthroop Date 2018-02-07 Time 08:29 Rev Time 0.00
Received By cthroop Date 2018-02-06 Time 17:16 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2018-01-03 Cont ID  
Sent By cthroop Date 2018-01-03 Time 10:32 Rev Time 0.00
Received By cthroop Date 2017-12-27 Time 16:35 Sent To  
Notes
2018-01-03 10:33:28BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT
 FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID.
 UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE
 SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN
 IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP
 AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE
 CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN
 BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY
 IMPACT FEES AT (561) 233-5025.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2017-12-13 Cont ID  
Sent By hmoser Date 2017-12-13 Time 14:38 Rev Time 0.00
Received By hmoser Date 2017-12-13 Time 13:37 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2017-11-28 Cont ID  
Sent By thunt Date 2017-11-28 Time 15:33 Rev Time 0.00
Received By thunt Date 2017-11-28 Time 15:33 Sent To G
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2018-02-07 Cont ID  
Sent By cthroop Date 2018-02-07 Time 08:29 Rev Time 0.00
Received By cthroop Date 2018-02-06 Time 17:15 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2018-01-03 Cont ID  
Sent By cthroop Date 2018-01-03 Time 11:34 Rev Time 0.00
Received By cthroop Date 2017-12-27 Time 16:35 Sent To  
Notes
2018-01-03 11:36:49BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE PRODUCT APPROVALS FOR NEW FLAT ROOF.
 2. SELECT METAL ROOF SYSTEM TO BE INSTALLED FROM
 PRODUCT APPROVAL.
  
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING, WINDOW AND DOOR
 SUBMITTALS.
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2018-01-19 Cont ID  
Sent By AW Date 2018-01-19 Time 11:41 Rev Time 0.00
Received By awooten Date 2018-01-19 Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date   Cont ID  
Sent By AW Date 2017-12-01 Time   Rev Time  
Received By   Date 2017-12-01 Time   Sent To  
Notes
2017-12-01 13:23:10***************************ZONING REVIEW
 FAILED******************************
  
 STRUCTURAL INTRUSIONS. STRUCTURAL OVERHANGS, INCLUDING
 BUT NOT LIMITED TO BALCONIES, CORNICES, GUTTERS, EAVES,
 AND ROOF OVERHANG PROJECTIONS SHALL NOT EXTEND FARTHER
 THAN THREE FEET INTO ANY SETBACK.
  
 PROVIDE THE DIMENSIONS FROM THE ROOF OVERHANGS.
  
 ALANA WOOTEN
 ASSOCIATE PLANNER
 PLANNING DIVISION
 561-466-1449
 [email protected]