| Plan Review Stops For Permit 17110755 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-02-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-02-07 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-02-06 |
Time |
17:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-01-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-01-03 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-12-27 |
Time |
16:35 |
Sent To |
|
|
| Notes |
| 2018-01-03 11:39:49 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. OWNER/AGENT TO SIGN ENERGY SUBMITTAL. | | | | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-02-05 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-02-05 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-02-05 |
Time |
15:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-12-13 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-12-13 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-12-13 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2017-12-13 11:09:11 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PLAN SHOWS STANDARD RECESS LIGHTS IN CLOSETS. PER | | | CODE: "LIGHTING WITH OPEN OR PARTIALLY ENCLOSED LAMPS | | | AND PENDANT LUMINAIRES OR LAMPHOLDERS SHALL NOT BE | | | PERMITTED IN CLOTHES CLOSETS". PROVIDE CORRECTION. NEC | | | 410.16; FBC RE4003.12 | | | 2. PROVIDE GFCI PROTECTION FOR POOL PUMP AND POOL SPA | | | PUMP, WHERE APPLICABLE. NEC 680.21(C), 680.44; FBC RE | | | 4203.1.3, 4208.1 | | | 3. NOTE 2 ON SHEET E-002 REFERENCES THE 2008 NEC, WHICH | | | IS NOT THE CURRENT CODE. PROVIDE CORRECTION. FBC | | | PREFACE, 2011 NEC | | | 4. BE ADVISED THAT FIRE ALARM, LOW VOLTAGE SYSTEMS, | | | LIGHTNING PROTECTION, GENERATORS, COMMERCIAL HOOD | | | SYSTEMS, SIGNS, SITE LIGHTING, AND SWIMMING POOLS | | | (WHERE APPLICABLE) ARE NOT INCLUDED IN THE SCOPE OF | | | THIS PLAN REVIEW. PROVIDE A BLOCK NOTE INDICATING THE | | | REQUIRED SEPARATE PERMITS AND DATA SPECIFICATION SHEET | | | SUBMITTALS FOR ANY OF THESE SYSTEMS PRESENT. FBC 105.1, | | | 107.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2018-02-07 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2018-02-07 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2018-02-07 |
Time |
13:02 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2017-11-28 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2017-11-28 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2017-11-28 |
Time |
15:33 |
Sent To |
|
|
| Notes |
| 2017-11-28 15:37:23 | 11-28-2017 GAS 1ST REVIEW**DENIED** | | | | | | 1) SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE 2014 | | | FBC-FUEL GAS CODE SEC.304.1, 614.5 (CLOTHES DRYERS) OR | | | 2014 FBC-RES. SEC. G 2407.1 AND G2439.4 (CLOTHES | | | DRYERS). | | | | | | 2) SUBMIT MANUFACTURER?S SPECIFICATION SHEETS / | | | INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO VERIFY | | | COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, AND | | | FBC-2014 FUEL GAS CODE SEC. 402.2, AND 301.3 OR 2014 | | | FBC-RES. SEC. G2404.3. GAS APPLIANCES SHALL BE LISTED | | | AND LABELED. THE INSTALLATION MANUALS FOR ALL GAS | | | APPLIANCES / EQUIPMENT SHALL BE ONSITE AT THE TIME OF | | | INSPECTION. FGC SEC.305.1, FBC-RES. SEC.G2408.1 | | | | | | 3) SUBMIT TWO COPIES OF THE APPLICABLE SIZING TABLES | | | USED TO SIZE THE GAS SYSTEM OR PLACE A NOTE ON THE | | | PLANS/DRAWINGS SPECIFYING WHICH SIZING TABLE(S) FROM | | | THE GAS CODE OR OTHER STANDARD THAT WERE USED IN THE | | | DESIGN OF THIS GAS SYSTEM. REFER TO THE 2014 FBC-FUEL | | | GAS SECS. 401.4, 401.8 THRU 402.6.1 AND TABLES 402.4 | | | (1) THRU 402.4 (37) OR 2014 FBC-RES. SEC. G2412.4, | | | G2412.8, G2413.1, G2413.2, & G2413.3 | | | | | | 4) ) SHOW THE LOCATION OF ALL MP (STEP-DOWN) | | | REGULATORS. A LISTED SHUTOFF VALVE SHALL BE INSTALLED | | | IMMEDIATELY AHEAD OF EACH MP REGULATOR. FBC-FUEL GAS | | | SEC.409.4, FBC-RESIDENTIAL SEC. G 2420.4. I | | | | | | 5) SUBMIT MANUFACTURER?S SPECIFICATIONS FOR THE | | | PRESSURE REGULATORS. REGULATORS INSTALLED ON THE | | | EXTERIOR OF THE BUILDING SHALL BE APPROVED FOR OUTDOOR | | | INSTALLATION. 2014 FGC SEC.410.1 | | | | | | 6) SHOW THE DISTANCE FROM THE 2 PSI REGULATOR TO THE | | | APPLIANCE. COMPLY WITH 2014 FBC-FUEL GAS TABLE 402.4 | | | (28) FOR THE PROPER PIPE SIZE AND BTU LOAD | | | | | | TIM HUNT | | | PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER | | | CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | 561-805-6695 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-02-07 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2018-02-07 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2018-01-12 |
Time |
14:20 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-01-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-01-03 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-11-17 |
Time |
14:01 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2018-02-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-02-07 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-02-06 |
Time |
17:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2018-01-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-01-03 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-12-27 |
Time |
16:35 |
Sent To |
|
|
| Notes |
| 2018-01-03 10:33:28 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT | | | FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID. | | | UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE | | | SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN | | | IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP | | | AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE | | | CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN | | | BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY | | | IMPACT FEES AT (561) 233-5025. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2017-12-13 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2017-12-13 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2017-12-13 |
Time |
13:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2017-11-28 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2017-11-28 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2017-11-28 |
Time |
15:33 |
Sent To |
G |
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2018-02-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-02-07 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-02-06 |
Time |
17:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-01-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-01-03 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-12-27 |
Time |
16:35 |
Sent To |
|
|
| Notes |
| 2018-01-03 11:36:49 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE PRODUCT APPROVALS FOR NEW FLAT ROOF. | | | 2. SELECT METAL ROOF SYSTEM TO BE INSTALLED FROM | | | PRODUCT APPROVAL. | | | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING, WINDOW AND DOOR | | | SUBMITTALS. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-01-19 |
|
|
Cont ID |
|
| Sent By |
AW |
Date |
2018-01-19 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2018-01-19 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
AW |
Date |
2017-12-01 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
2017-12-01 |
Time |
|
Sent To |
|
|
| Notes |
| 2017-12-01 13:23:10 | ***************************ZONING REVIEW | | | FAILED****************************** | | | | | | STRUCTURAL INTRUSIONS. STRUCTURAL OVERHANGS, INCLUDING | | | BUT NOT LIMITED TO BALCONIES, CORNICES, GUTTERS, EAVES, | | | AND ROOF OVERHANG PROJECTIONS SHALL NOT EXTEND FARTHER | | | THAN THREE FEET INTO ANY SETBACK. | | | | | | PROVIDE THE DIMENSIONS FROM THE ROOF OVERHANGS. | | | | | | ALANA WOOTEN | | | ASSOCIATE PLANNER | | | PLANNING DIVISION | | | 561-466-1449 | | | [email protected] |
|
|