Plan Review Details - Permit 17110738
Plan Review Stops For Permit 17110738
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-07-20 Cont ID  
Sent By dharvey Date 2018-07-20 Time 18:16 Rev Time 0.00
Received By dharvey Date 2018-07-20 Time 18:16 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-12-11 Cont ID  
Sent By cthroop Date 2017-12-11 Time 15:40 Rev Time 0.00
Received By cthroop Date 2017-12-11 Time 14:50 Sent To  
Notes
2017-12-11 15:46:55BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. DESIGNER OF RECORD TO ESTABLISH RISK CATEGORY PER
 FBC CHPT. 16.
 2. PROVIDE DESIGN WIND LOADS FOR SOLAR TREE PER FBC
 CHPT. 16.
 3. PROVIDE ATTACHMENT DETAIL FOR SOLAR TREE TO
 FOUNDATION.
 4. PROVIDE 2ND COPY OF SITE PLAN.
  
  
 FBC 107.3.5.1.1(8) - PROVIDE WIND DESIGN LOADS/DESIGN
 PRESSURES PURSUANT TO FBC-CHAPTER 16
  
 1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE
 STRUCTURE:
 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST),
 MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED,
 VASD, AS DETERMINED IN ACCORDANCE WITH SECTION
 1609.3.1.
 2. RISK CATEGORY.
 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE
 THAN ONE WIND EXPOSURE IS UTILIZED.
 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT.
 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY
 DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL
 RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/
 M2).
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN
 UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE
 OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT
 IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 FBC107.1 GENERAL. SUBMITTAL DOCUMENTS CONSISTING OF
 CONSTRUCTION DOCUMENTS, STATEMENT OF SPECIAL
 INSPECTIONS, GEOTECHNICAL REPORT AND OTHER DATA SHALL
 BE SUBMITTED IN TWO OR MORE SETS WITH EACH PERMIT
 APPLICATION.
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2017-12-07 Cont ID  
Sent By jleahy Date 2017-12-07 Time 12:57 Rev Time 0.00
Received By jleahy Date 2017-11-27 Time 17:25 Sent To B
Notes
2017-11-27 17:25:39SENT TO ZONING JLEAHY

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-12-11 Cont ID  
Sent By cthroop Date 2017-12-11 Time 15:47 Rev Time 0.00
Received By cthroop Date 2017-11-16 Time 13:49 Sent To I
Notes
2017-11-20 13:50:03ROUTED TO JLEAHY

Review Stop Z ZONING
Rev No 1 Status F Date 2017-12-06 Cont ID  
Sent By JR Date 2017-12-06 Time 13:46 Rev Time 0.00
Received By jroach Date 2017-12-01 Time 10:18 Sent To E
Notes
2017-12-06 13:46:12ZONING PLAN REVIEW
 ___________________________________________
  
 DATE OF REVIEW: 12.06.2017
 PERMIT NO.: 17110738
 ___________________________________________
  
 REVIEW STATUS: FAILED
 ___________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. AS THE SUBJECT SITE IS PART OF AN APPROVED
 DEVELOPMENT OF SIGNIFICANT IMPACT (DSI), A MINOR
 AMENDMENT TO THE DSI SHALL BE SUBMITTED TO THE
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION,
 AND APPROVED, PRIOR TO THE ISSUANCE OF A BUILDING
 PERMIT.
  
 2. TWO (2) COPIES OF A SITE PLAN IDENTIFYING THE
 LOCATION OF THE PROPOSED IMPROVEMENTS SHALL BE
 PROVIDED?ONLY ONE (1) COPY WAS INCLUDED IN THE PERMIT
 PACKAGE.
  
 3. THE SITE PLAN PROVIDED HAS A SHADED AREA
 (HIGHLIGHTED IN YELLOW) AS WELL AS TWO (2) RED
 ?X?S?PLEASE CLARIFY WHICH REPRESENTS THE PROPOSED
 LOCATION OF THE IMPROVEMENTS.
 ___________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ___________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 F: 561.822.1460
  
 E: [email protected]
  
 W: WPB.ORG
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved