Plan Review Details - Permit 17110730
Plan Review Stops For Permit 17110730
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2018-08-06 Cont ID  
Sent By skennedy Date 2018-08-06 Time 13:34 Rev Time 0.00
Received By skennedy Date 2018-08-06 Time 13:34 Sent To Z
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2018-03-16 Cont ID  
Sent By rmcdouga Date 2018-03-16 Time 18:59 Rev Time 0.00
Received By rmcdouga Date 2018-03-16 Time 17:46 Sent To I
Notes
2018-03-16 18:59:55PLAN
 REVIEW COMMENTS
  
 2ND REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) ONE SET OF THE PLANS DOES NOT CONTAIN THE REVISED
 SHEET 02 THAT SHOWS THE WALL SECTION AND THE SLAB PLAN.
 FBC-R107.2.1
  
 2) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS
 FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC
 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE
 BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER
 OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH
 FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS
 AND MAXIMUM DESIGN PRESSURES FOR THE ROOFING MATERIALS.
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-12-07 Cont ID  
Sent By rmcdouga Date 2017-12-07 Time 19:11 Rev Time 0.00
Received By rmcdouga Date 2017-12-07 Time 16:42 Sent To  
Notes
2017-12-07 18:32:49PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) PROVIDE A STRUCTURAL REINFORCING AND FLASHING DETAIL
 AT WINDOW OPENING IN NEW BLOCK WALL. FBC-R611.8.1 &
 FBC-R703.8
  
 2) SPECIFY THE LINTEL FOR THE WINDOW OPENING AND
 PROVIDE A LINTEL TABLE. FBC-R611.8.2
  
 3) PROVIDE WINDOW BUCK FASTENING DETAIL ON THE PLANS.
 FBC-R612.7.2.1
  
 4) PROVIDE AN EXTERIOR WALL SECTION THAT SHOWS THE 16"
 OVERHANG DETAILS. FBC 107.2.1
  
 5) PROVIDE AN EXTERIOR WALL SECTION THAT SHOWS THE 12"
 OVERHANG. DETAILS. FBC 107.2.1
  
 6) THE AREA TABULATIONS THAT ARE PROVIDED ON SHEETS 01
 AND E-1 ARE UN-CLEAR AND CONFUSING. SPECIFY THE
 EXISTING AREAS AND THE NEW AREAS. THE EXISTING A/C AREA
 SHOULD BE ON TOP, FOLLOWED BY THE EXISTING LAUNDRY AREA
 AND FINALLY THE EXISTING TOTAL AREA. BELOW THIS LIST
 THE NEW ADDITION A/C AREA, FOLLOWED BY THE NEW TOTAL
 A/C AREA AND THEN THE NEW TOTAL AREA. FBC 107.2.1
  
 7) REVISE THE EXTERIOR WALL SECTION TO SHOW THAT THE
 WALL INSULATION WILL BE CONTINOUS UP TO THE ROOF
 INSULATION. THE SECTION ON SHEET 02 DOES NOT SHOW ANY
 INSULATION IN THE UN-VENTED ATTIC SPACE FROM THE TOP OF
 THE BLOCK WALL TO THE INSULATION ON THE UNDERSIDE OF
 THE ROOF. FBC-R806.5
  
 8) SUBMIT TWO COPIES OF THE PRODUCT EVALUATION REPORT
 FOR THE ICYNENE SPRAY FOAM INSULATION THAT WILL BE
 USED. FBC-R316
  
 9) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS
 FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC
 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE
 BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER
 OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH
 FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS
 AND MAXIMUM DESIGN PRESSURES FOR EACH OF THE DIFFERENT
 ROOFING MATERIALS AND THE SINGLE HUNG WINDOW.
  
 10) ONE SET OF THE PLANS HAS NOT BE SIGNED AND SEALED
 BY THE FLORIDA LICENSED PROFESSIONAL ENGINEER. F.S. 471
 AND FAC 61G15-23.003 REQUIRE THE ENGINEER'S HANDWRITTEN
 SIGNATURE AND SEAL ON THE PLANS.
  
 11) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT
 A RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW
 COMMENTS HAS BEEN ADDRESSED.
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-03-15 Cont ID  
Sent By jpearson Date 2018-03-15 Time 14:06 Rev Time 0.00
Received By jpearson Date 2018-03-15 Time 14:06 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-12-08 Cont ID  
Sent By jpearson Date 2017-12-08 Time 16:48 Rev Time 0.00
Received By jpearson Date 2017-12-08 Time 16:48 Sent To  
Notes
2017-12-08 16:48:33CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION
 NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. A MINIMUM OF ONE 20 AMPERE BRANCH CIRCUIT SHALL BE
 PROVIDED TO SUPPLY BATHROOM RECEPTACLE OUTLET(S). SUCH
 CIRCUITS SHALL HAVE NO OTHER OUTLETS. PROVIDE
 CORRECTION. NEC 210.11(C)(3) , FBC RE3703.4
 2. LIGHTING IN CLOSET NOT SPECIFIED. INCLUDE NOTE TO
 COMPLY: "LIGHTING WITH OPEN OR PARTIALLY ENCLOSED LAMPS
 AND PENDANT LUMINAIRES OR LAMPHOLDERS SHALL NOT BE
 PERMITTED IN CLOTHES CLOSETS". NEC 410.16; FBC
 RE4003.12
 3. PROVIDE COMPLIANCE: "ALL 120-VOLT, SINGLE PHASE, 15
 AND 20 AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS IN
 DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS,
 PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS,
 RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR AREAS
 OR ROOMS, SHALL HAVE AFCI PROTECTION." A NOTE WILL
 SUFFICE. NEC 210.12; FBC RE3902.12
 4. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED
 PER CODE. SHOW ON PLAN ALL EXISTING ALARMS. IF NONE ARE
 EXISTING OR NOT TO CODE, SHOW AS NEW INSTALLATIONS. FBC
 R314.3, 315.1, FBC 107.2.1
 5. FOR A ONE FAMILY DWELLING AND EACH UNIT OF A
 TWO-FAMILY DWELLING THAT IS AT GRADE LEVEL, AT LEAST
 ONE RECEPTACLE OUTLET READILY ACCESSIBLE FROM GRADE AND
 NOT MORE THAN 2.0 M (6.5 FT) ABOVE GRADE LEVEL SHALL BE
 INSTALLED AT THE FRONT AND BACK OF THE DWELLING.
 PROVIDE CORRECTION. NEC 210.52(E)(1) FBC RE3901.7
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-08-06 Cont ID  
Sent By skennedy Date 2018-08-06 Time 14:36 Rev Time 0.00
Received By skennedy Date 2018-08-06 Time 13:34 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-03-16 Cont ID  
Sent By rmcdouga Date 2018-03-16 Time 19:00 Rev Time 0.00
Received By rmcdouga Date 2018-03-08 Time 10:38 Sent To  
Notes
2018-03-09 10:38:53RESUB ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-12-14 Cont ID  
Sent By rmcdouga Date 2017-12-14 Time 08:41 Rev Time 0.00
Received By rmcdouga Date 2017-11-16 Time 14:06 Sent To  
Notes
2017-12-13 07:10:36TO RM DESK
  
  
2017-11-20 14:06:37R24

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2018-03-16 Cont ID  
Sent By rmcdouga Date 2018-03-16 Time 17:12 Rev Time 0.00
Received By rmcdouga Date 2018-03-16 Time 17:12 Sent To  
Notes
2018-03-16 17:13:07MU-2018-7730, NO FEES DUE

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2017-12-07 Cont ID  
Sent By rmcdouga Date 2017-12-07 Time 14:13 Rev Time 0.00
Received By rmcdouga Date 2017-12-07 Time 14:13 Sent To  
Notes
2017-12-07 14:13:56BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2018-03-16 Cont ID  
Sent By rmcdouga Date 2018-03-16 Time 16:54 Rev Time 0.00
Received By rmcdouga Date 2018-03-16 Time 16:54 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-12-07 Cont ID  
Sent By rmcdouga Date 2017-12-07 Time 16:42 Rev Time 0.00
Received By rmcdouga Date 2017-12-07 Time 16:42 Sent To  
Notes
2017-12-07 17:09:16PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY MECHANICAL
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) SUBMIT TWO SETS OF ENERGY CODE COMPLIANCE DOCUMENTS
 FOR THE NEW ADDITION. FBC ENERGY CONSERVATION SECTIONS
 R402 OR R405.
  
 2) FBC-R 303.9 REQUIRES HABITABLE ROOMS TO BE HEATED.
 SUBMIT TWO SETS OF EQUIPMENT SIZING CALCULATIONS TO
 SHOW THAT THE EXISTING HEATING AND COOLING EQUIPMENT IS
 ADEQUATE TO CONDITION THE NEW ADDITION. FBCR-M1401.3
  
 3) FBC 107.2.1 PROVIDE THE MODEL NUMBERS AND
 SPECIFICATIONS OF THE HEATING AND COOLING EQUIPMENT IN
 AN EQUIPMENT SCHEDULE ON THE MECHANICAL PLAN THAT
 CORRESPONDS WITH THE EQUIPMENT SIZING CALCULATIONS.
  
 4) SPECIFY THE SIZE OF THE DUCT THAT WILL BE CONNECTED
 TO THE EXISTING DISTRIBUTION BOX. FBC 107.2.1
  
 5) FBC-R - M 1602.4 PROVIDE BALANCED AIR RETURN AT THE
 NEW MASTER BEDROOM. HABITABLE ROOMS ONLY SHALL BE
 REQUIRED TO MEET THESE REQUIREMENTS FOR PROPER BALANCED
 RETURN AIR EXCLUDING BATHROOMS, CLOSETS, STORAGE ROOMS
 AND LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY AIR INTO THE
 MASTER SUITE SHALL BE INCLUDED.
  
 6) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT A
 RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW
 COMMENTS HAS BEEN ADDRESSED.

Review Stop P PLUMBING
Rev No 2 Status P Date 2018-03-16 Cont ID  
Sent By rmcdouga Date 2018-03-16 Time 17:46 Rev Time 0.00
Received By rmcdouga Date 2018-03-16 Time 16:54 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-12-14 Cont ID  
Sent By rmcdouga Date 2017-12-14 Time 08:41 Rev Time 0.00
Received By rmcdouga Date 2017-12-14 Time 06:59 Sent To I
Notes
2017-12-14 08:47:33PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE PLANS HAVE AN FLORIDA ENGINEER'S TITLE BLOCK AND
 ARE REQUIRED TO HAVE THE ENGINEER'S HANDWRITTEN
 SIGNATURE AND SEAL AFFIXED. ONE SET OF PLANS HAS NOT
 BEEN SIGNED AND SEALED BY THE ENGINEER. FS 471 & FAC
 61G15-23.003

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2018-08-06 Cont ID  
Sent By skennedy Date 2018-08-06 Time 13:56 Rev Time 0.00
Received By skennedy Date 2018-08-06 Time 13:56 Sent To  
Notes
2018-08-06 13:56:45ROOFING BY DEFERRED SUBMITTAL OR SEPARATE PERMIT.

Review Stop Z ZONING
Rev No 3 Status P Date   Cont ID  
Sent By   Date 2018-08-06 Time   Rev Time 0.00
Received By pgreilic Date 2018-08-06 Time 14:33 Sent To  
Notes
2018-08-06 14:34:19PAUL GREILICH, SENIOR PLANNER
 561-822-1443
 [email protected]

Review Stop Z ZONING
Rev No 2 Status F Date   Cont ID  
Sent By   Date 2018-03-13 Time   Rev Time 0.00
Received By pgreilic Date 2018-03-12 Time 16:12 Sent To E
Notes
2018-03-13 11:07:161.) LABEL SETBACKS OF PROPOSED ADDITION
  
 PAUL GREILICH, SENIOR PLANNER
 561-822-1443
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date   Cont ID  
Sent By AW Date 2017-12-05 Time   Rev Time 0.00
Received By pgreilic Date 2018-03-13 Time 11:06 Sent To  
Notes
2017-12-05 14:15:06***************************ZONING REVIEW
 FAILED*****************************
  
 PROVIDE A SURVEY OF THE SUBJECT PROPERTY AND A SITE
 PLAN SHOWING ALL SETBACKS (EXISTING AND NEW).
  
 FURTHER COMMENTS MAY FOLLOW.
  
 THANKS,
 ALANA WOOTEN
 ASSOCIATE PLANNER
 PLANNING DIVISION
 561-822-1449
 [email protected]