| Plan Review Stops For Permit 17110534 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-12-20 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2017-12-20 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2017-12-20 |
Time |
15:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2017-11-17 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2017-11-17 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2017-11-17 |
Time |
07:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-12-28 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-12-28 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-12-28 |
Time |
16:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-12-04 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-12-04 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-12-04 |
Time |
16:03 |
Sent To |
I |
|
| Notes |
| 2017-12-04 16:45:16 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4 | | | 2. PROVIDE GRAPH/CALCULATION OF INTERIOR LIGHTING POWER | | | ALLOWANCES PER THE FBC ENERGY CODE IN RELATION TO THE | | | CONNECTED INTERIOR LIGHTING PROPOSED TO COMPLY WITH | | | CODE. FBC EC 405.5 | | | 3. PROVIDE RECEPTACLE CONTROL REQUIRED BY ASHREA 90.1: | | | 8.4.2. FBC EC 405.7.1 | | | 4. BE ADVISED THAT FIRE ALARM, LOW VOLTAGE SYSTEMS, | | | LIGHTNING PROTECTION, GENERATORS, COMMERCIAL HOOD | | | SYSTEMS, SIGNS, SITE LIGHTING, AND SWIMMING POOLS | | | (WHERE APPLICABLE) ARE NOT INCLUDED IN THE SCOPE OF | | | THIS PLAN REVIEW. PROVIDE A BLOCK NOTE INDICATING THE | | | REQUIRED SEPARATE PERMITS AND DATA SPECIFICATION SHEET | | | SUBMITTALS FOR ANY OF THESE SYSTEMS PRESENT. FBC 105.1, | | | 107.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-12-20 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2017-12-20 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2017-12-20 |
Time |
14:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2017-11-17 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2017-11-17 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2017-11-17 |
Time |
11:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-01-04 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-01-04 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-12-13 |
Time |
13:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-12-04 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-12-04 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-11-14 |
Time |
15:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2017-12-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-12-22 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-12-22 |
Time |
14:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-11-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-11-28 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-11-28 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2017-11-28 10:45:55 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #17110534 | | | 11/28/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET M-2, A-1, & A-2: PLEASE CLARIFY HOW THE FIRE | | | DAMPERS ARE BEING INSTALLED ON THE NORTH-SIDE TENANT | | | SEPARATION WALL. DETAIL 3/A-2 DOES NOT INDICATE THE | | | SEPARATION WALL IS FIRE-RATED, AND SHOWS IT TERMINATING | | | BELOW THE CEILING. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-01-04 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-01-04 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-01-04 |
Time |
09:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-11-29 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-11-29 |
Time |
18:01 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-11-29 |
Time |
18:01 |
Sent To |
|
|
| Notes |
| 2017-11-29 18:03:42 | | | | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | | | | PLUMBING COMMENTS: | | | | | | 1. PROVIDE ISOMETRIC DIAGRAM FOR WATER AND SANITARY. | | | PER WPB AMEND TO FBC 107.3.5.1.3(13) | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|