Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-12-20 Cont ID  
Sent By aclange Date 2017-12-20 Time 15:23 Rev Time 0.00
Received By aclange Date 2017-12-20 Time 15:18 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2017-11-17 Cont ID  
Sent By aclange Date 2017-11-17 Time 08:53 Rev Time 0.00
Received By aclange Date 2017-11-17 Time 07:58 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-12-28 Cont ID  
Sent By jpearson Date 2017-12-28 Time 16:03 Rev Time 0.00
Received By jpearson Date 2017-12-28 Time 16:03 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-12-04 Cont ID  
Sent By jpearson Date 2017-12-04 Time 16:45 Rev Time 0.00
Received By jpearson Date 2017-12-04 Time 16:03 Sent To I
Notes
2017-12-04 16:45:16CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION
 NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED
 CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS,
 AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY
 WITH CODE. NEC 210.8, 210.12, 215.5, 408.4
 2. PROVIDE GRAPH/CALCULATION OF INTERIOR LIGHTING POWER
 ALLOWANCES PER THE FBC ENERGY CODE IN RELATION TO THE
 CONNECTED INTERIOR LIGHTING PROPOSED TO COMPLY WITH
 CODE. FBC EC 405.5
 3. PROVIDE RECEPTACLE CONTROL REQUIRED BY ASHREA 90.1:
 8.4.2. FBC EC 405.7.1
 4. BE ADVISED THAT FIRE ALARM, LOW VOLTAGE SYSTEMS,
 LIGHTNING PROTECTION, GENERATORS, COMMERCIAL HOOD
 SYSTEMS, SIGNS, SITE LIGHTING, AND SWIMMING POOLS
 (WHERE APPLICABLE) ARE NOT INCLUDED IN THE SCOPE OF
 THIS PLAN REVIEW. PROVIDE A BLOCK NOTE INDICATING THE
 REQUIRED SEPARATE PERMITS AND DATA SPECIFICATION SHEET
 SUBMITTALS FOR ANY OF THESE SYSTEMS PRESENT. FBC 105.1,
 107.2.1
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2017-12-20 Cont ID  
Sent By wjolin Date 2017-12-20 Time 14:29 Rev Time 0.00
Received By wjolin Date 2017-12-20 Time 14:27 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2017-11-17 Cont ID  
Sent By wjolin Date 2017-11-17 Time 11:21 Rev Time 0.00
Received By wjolin Date 2017-11-17 Time 11:16 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-01-04 Cont ID  
Sent By gjohnson Date 2018-01-04 Time 09:36 Rev Time 0.00
Received By gjohnson Date 2017-12-13 Time 13:16 Sent To  
Notes
2017-12-14 13:16:41B21

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-12-04 Cont ID  
Sent By jpearson Date 2017-12-04 Time 16:45 Rev Time 0.00
Received By jpearson Date 2017-11-14 Time 15:17 Sent To  
Notes
2017-11-14 15:17:43B18

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2017-12-22 Cont ID  
Sent By ccole Date 2017-12-22 Time 15:25 Rev Time 0.00
Received By ccole Date 2017-12-22 Time 14:49 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-11-28 Cont ID  
Sent By ccole Date 2017-11-28 Time 10:36 Rev Time 0.00
Received By ccole Date 2017-11-28 Time 10:36 Sent To  
Notes
2017-11-28 10:45:551ST REVIEW FBC-2014 MECHANICAL
 PERMIT #17110534
 11/28/17
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET M-2, A-1, & A-2: PLEASE CLARIFY HOW THE FIRE
 DAMPERS ARE BEING INSTALLED ON THE NORTH-SIDE TENANT
 SEPARATION WALL. DETAIL 3/A-2 DOES NOT INDICATE THE
 SEPARATION WALL IS FIRE-RATED, AND SHOWS IT TERMINATING
 BELOW THE CEILING.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2018-01-04 Cont ID  
Sent By gjohnson Date 2018-01-04 Time 09:36 Rev Time 0.00
Received By gjohnson Date 2018-01-04 Time 09:36 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-11-29 Cont ID  
Sent By gjohnson Date 2017-11-29 Time 18:01 Rev Time 0.00
Received By gjohnson Date 2017-11-29 Time 18:01 Sent To  
Notes
2017-11-29 18:03:42 
 1ST REVIEW: FBC 2014 5TH EDITION
  
  
 PLUMBING COMMENTS:
  
 1. PROVIDE ISOMETRIC DIAGRAM FOR WATER AND SANITARY.
 PER WPB AMEND TO FBC 107.3.5.1.3(13)
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  