Plan Review Details - Permit 17110532
Plan Review Stops For Permit 17110532
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-12-21 Cont ID  
Sent By aclange Date 2017-12-21 Time 07:35 Rev Time 0.00
Received By aclange Date 2017-12-20 Time 16:10 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2017-11-20 Cont ID  
Sent By aclange Date 2017-11-20 Time 08:13 Rev Time 0.00
Received By aclange Date 2017-11-17 Time 16:43 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-12-29 Cont ID  
Sent By jpearson Date 2017-12-29 Time 10:16 Rev Time 0.00
Received By jpearson Date 2017-12-29 Time 10:16 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-12-04 Cont ID  
Sent By jpearson Date 2017-12-04 Time 14:30 Rev Time 0.00
Received By jpearson Date 2017-12-04 Time 13:46 Sent To I
Notes
2017-12-04 14:29:57CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION
 NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED
 CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS,
 AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY
 WITH CODE. NEC 210.8, 210.12, 215.5, 408.4
 2. PROVIDE RECEPTACLE CONTROL REQUIRED BY ASHREA 90.1:
 8.4.2. FBC EC 405.7.1
 3. PROVIDE GRAPH/CALCULATION OF INTERIOR LIGHTING POWER
 ALLOWANCES PER THE FBC ENERGY CODE IN RELATION TO THE
 CONNECTED INTERIOR LIGHTING PROPOSED TO COMPLY WITH
 CODE. FBC EC 405.5
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2017-12-15 Cont ID  
Sent By pleduc Date 2017-12-15 Time   Rev Time 0.00
Received By pleduc Date 2017-12-15 Time 09:56 Sent To  
Notes
2017-12-15 10:43:262ND REVIEW COMMENTS:
  
  
 THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
 1) SHEET A 1 - DOOR # 1 IS AN EXISTING 1 HOUR RATED
 DOOR. PLEASE ENSURE THAT THE REPLACEMENT IS EQUALLY
 RATED AND IS PROPERLY LABELED.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2017-11-17 Cont ID  
Sent By pleduc Date 2017-11-17 Time   Rev Time 0.00
Received By pleduc Date 2017-11-17 Time 09:29 Sent To  
Notes
2017-11-17 14:24:17THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
 1) SHEET A 1 - DOOR # 1 IS AN EXISTING 1 HOUR RATED
 DOOR. PLEASE ENSURE THAT THE REPLACEMENT IS EQUALLY
 RATED AND IS PROPERLY LABELED.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-01-04 Cont ID  
Sent By gjohnson Date 2018-01-04 Time 10:00 Rev Time 0.00
Received By gjohnson Date 2017-12-13 Time 13:12 Sent To  
Notes
2017-12-14 13:12:32B20

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-12-04 Cont ID  
Sent By jpearson Date 2017-12-04 Time 14:30 Rev Time 0.00
Received By jpearson Date 2017-11-14 Time 15:21 Sent To  
Notes
2017-11-14 15:21:14B20

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2017-12-22 Cont ID  
Sent By ccole Date 2017-12-22 Time 14:33 Rev Time 0.00
Received By ccole Date 2017-12-22 Time 14:27 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-11-28 Cont ID  
Sent By ccole Date 2017-11-28 Time 11:22 Rev Time 0.00
Received By ccole Date 2017-11-28 Time 11:22 Sent To  
Notes
2017-11-28 11:24:531ST REVIEW FBC-2014 MECHANICAL
 PERMIT #17110532
 11/28/17
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET M-2: PROVIDE FIRE DAMPER SYMBOLS AT DUCT
 PENETRATIONS OF FIRE-RATED WALLS, AND PROVIDE AN
 INSTALLATION DETAIL.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2018-01-04 Cont ID  
Sent By gjohnson Date 2018-01-04 Time 09:59 Rev Time 0.00
Received By gjohnson Date 2018-01-04 Time 09:59 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-11-29 Cont ID  
Sent By gjohnson Date 2017-11-29 Time 17:36 Rev Time 0.00
Received By gjohnson Date 2017-11-29 Time 15:53 Sent To  
Notes
2017-11-29 17:55:191ST REVIEW: FBC 2014 5TH EDITION
  
 PLUMBING COMMENTS:
  
 1. BREAKROOM SINK SHOW COMPLIANCE WITH FBC ACC 606.2
 CLEAR FLOOR SPACE.
 A CLEAR FLOOR SPACE COMPLYING WITH 305, POSITIONED FOR
 A FORWARD APPROACH, AND KNEE AND TOE CLEARANCE
 COMPLYING WITH 306 SHALL BE PROVIDED.
 606.3 HEIGHT.
 LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE FRONT
 OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES
 (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
  
 2. THE GRAB BARS SHALL BE MEASURED FROM THE GRIPPING
 SURFACE TO FINISH FLOOR. PER FBC ACC 608.3
  
 3. THE DOOR SWING OF THE BATHROOM DOOR APPEARS TO
 ENCROACH INTO THE CLEAR FLOOR SPACE THAT WAS PROVIDED
 TO COMPLY WITH FBC ACC 603.2.3 DOOR SWING.
 DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR
 CLEARANCE REQUIRED FOR ANY FIXTURE. DOORS SHALL BE
 PERMITTED TO SWING INTO THE REQUIRED TURNING SPACE.
  
 EXCEPTIONS:
 WHERE THE TOILET ROOM OR BATHING ROOM IS FOR INDIVIDUAL
 USE AND A CLEAR FLOOR SPACE COMPLYING WITH 305.3 IS
 PROVIDED WITHIN THE ROOM BEYOND THE ARC OF THE DOOR
 SWING, DOORS SHALL BE PERMITTED TO SWING INTO THE CLEAR
 FLOOR SPACE OR CLEARANCE REQUIRED FOR ANY FIXTURE.
  
 4. SHOW THE DIMENSIONS OF THE BATHROOM. PER WPB AMEND
 TO FBC 107.2.1
  
 5. PROVIDE ISOMETRIC DIAGRAMS FOR WATER AND SANITARY.
 PER WPB AMEND TO FBC 107.3.5.1.3(13)
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  
  