| Plan Review Stops For Permit 17110532 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-12-21 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2017-12-21 |
Time |
07:35 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2017-12-20 |
Time |
16:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2017-11-20 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2017-11-20 |
Time |
08:13 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2017-11-17 |
Time |
16:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-12-29 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-12-29 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-12-29 |
Time |
10:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-12-04 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-12-04 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-12-04 |
Time |
13:46 |
Sent To |
I |
|
| Notes |
| 2017-12-04 14:29:57 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4 | | | 2. PROVIDE RECEPTACLE CONTROL REQUIRED BY ASHREA 90.1: | | | 8.4.2. FBC EC 405.7.1 | | | 3. PROVIDE GRAPH/CALCULATION OF INTERIOR LIGHTING POWER | | | ALLOWANCES PER THE FBC ENERGY CODE IN RELATION TO THE | | | CONNECTED INTERIOR LIGHTING PROPOSED TO COMPLY WITH | | | CODE. FBC EC 405.5 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-12-15 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-12-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-12-15 |
Time |
09:56 |
Sent To |
|
|
| Notes |
| 2017-12-15 10:43:26 | 2ND REVIEW COMMENTS: | | | | | | | | | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | 1) SHEET A 1 - DOOR # 1 IS AN EXISTING 1 HOUR RATED | | | DOOR. PLEASE ENSURE THAT THE REPLACEMENT IS EQUALLY | | | RATED AND IS PROPERLY LABELED. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2017-11-17 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-11-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-11-17 |
Time |
09:29 |
Sent To |
|
|
| Notes |
| 2017-11-17 14:24:17 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | 1) SHEET A 1 - DOOR # 1 IS AN EXISTING 1 HOUR RATED | | | DOOR. PLEASE ENSURE THAT THE REPLACEMENT IS EQUALLY | | | RATED AND IS PROPERLY LABELED. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-01-04 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-01-04 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-12-13 |
Time |
13:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-12-04 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-12-04 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-11-14 |
Time |
15:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2017-12-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-12-22 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-12-22 |
Time |
14:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-11-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-11-28 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-11-28 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2017-11-28 11:24:53 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #17110532 | | | 11/28/17 | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET M-2: PROVIDE FIRE DAMPER SYMBOLS AT DUCT | | | PENETRATIONS OF FIRE-RATED WALLS, AND PROVIDE AN | | | INSTALLATION DETAIL. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-01-04 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-01-04 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-01-04 |
Time |
09:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-11-29 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-11-29 |
Time |
17:36 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-11-29 |
Time |
15:53 |
Sent To |
|
|
| Notes |
| 2017-11-29 17:55:19 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. BREAKROOM SINK SHOW COMPLIANCE WITH FBC ACC 606.2 | | | CLEAR FLOOR SPACE. | | | A CLEAR FLOOR SPACE COMPLYING WITH 305, POSITIONED FOR | | | A FORWARD APPROACH, AND KNEE AND TOE CLEARANCE | | | COMPLYING WITH 306 SHALL BE PROVIDED. | | | 606.3 HEIGHT. | | | LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE FRONT | | | OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES | | | (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. | | | | | | 2. THE GRAB BARS SHALL BE MEASURED FROM THE GRIPPING | | | SURFACE TO FINISH FLOOR. PER FBC ACC 608.3 | | | | | | 3. THE DOOR SWING OF THE BATHROOM DOOR APPEARS TO | | | ENCROACH INTO THE CLEAR FLOOR SPACE THAT WAS PROVIDED | | | TO COMPLY WITH FBC ACC 603.2.3 DOOR SWING. | | | DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR | | | CLEARANCE REQUIRED FOR ANY FIXTURE. DOORS SHALL BE | | | PERMITTED TO SWING INTO THE REQUIRED TURNING SPACE. | | | | | | EXCEPTIONS: | | | WHERE THE TOILET ROOM OR BATHING ROOM IS FOR INDIVIDUAL | | | USE AND A CLEAR FLOOR SPACE COMPLYING WITH 305.3 IS | | | PROVIDED WITHIN THE ROOM BEYOND THE ARC OF THE DOOR | | | SWING, DOORS SHALL BE PERMITTED TO SWING INTO THE CLEAR | | | FLOOR SPACE OR CLEARANCE REQUIRED FOR ANY FIXTURE. | | | | | | 4. SHOW THE DIMENSIONS OF THE BATHROOM. PER WPB AMEND | | | TO FBC 107.2.1 | | | | | | 5. PROVIDE ISOMETRIC DIAGRAMS FOR WATER AND SANITARY. | | | PER WPB AMEND TO FBC 107.3.5.1.3(13) | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | |
|
|