Plan Review Details - Permit 17110392
| Plan Review Stops For Permit 17110392 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-10-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-10-06 |
Time |
12:24 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-10-06 |
Time |
12:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-11-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-11-27 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-11-27 |
Time |
11:34 |
Sent To |
|
|
| Notes |
| 2017-11-27 15:49:18 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. ALL ITEMS OTHER THAN BUILDING, ROOFING, MECHANICAL, | | | ELECTRICAL, PLUMBING REQUIRE SEPARATE PERMITS AND | | | SEPARATE FEES, FBC 107. PLEASE SUBMIT A PERMIT | | | APPLICATION AND THE SAME NUMBER WILL BE USED FOR THE | | | PERMIT. | | | | | | 2. THE FLAGPOLE IS CONSIDERED A STRUCTURE WHICH IS | | | REQUIRED TO RESIST WIND LOADS. PROVIDE AN ENGINEERED | | | DETAIL, INCLUDING WIND DESIGN CRITERIA, FLORIDA STATUTE | | | 471. THE SOILS REPORT FOR THIS PARCEL SHOULD BE | | | REVIEWED BY DESIGNER OF FLAGPOLE PRIOR TO DESIGN; | | | INDICATE REVIEW ON ENGINEERING (OR IN A SEPARATE REVIEW | | | LETTER). | | | | | | 3. SEE THE SHOP DRAWING FOR THE FLAGPOLE, FOUNDATION IS | | | EXCLUDED FROM THE DESIGN. PLEASE INCLUDE FOUNDATION | | | DESIGN IN THE FLAGPOLE ENGINEERING. | | | | | | 4. THERE ARE A NUMBER OF REDLINES ON THE SHOP DRAWINGS. | | | INCORPORATE INTO THE ENGINEERING, FS 471. FOR INSTANCE, | | | FLAGPOLE WAS DESIGNED FOR A SPECIFIED SIZE OF FLAG; | | | THIS AFFECTS RESISTANCE TO WIND LOADS AND THEREFORE | | | CANNOT BE DONE WITH REDLINES BUT SHOULD BE INCORPORATED | | | INTO THE ENGINEERING. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-10-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-10-16 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-10-16 |
Time |
15:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-11-28 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-11-28 |
Time |
07:05 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-11-28 |
Time |
07:05 |
Sent To |
|
|
| Notes |
| 2017-11-28 07:05:10 | NO ELECTRICAL ISSUES, BUT NEED TO ADDRESS BUILDING | | | COMMENTS FOR A COMPLETE ELECTRICAL REVIEW. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-10-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-10-06 |
Time |
12:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-12-06 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2017-12-06 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-11-09 |
Time |
12:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2018-10-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-10-06 |
Time |
12:25 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-10-06 |
Time |
12:25 |
Sent To |
|
|
| Notes |
| 2018-10-06 12:25:44 | ORIGINAL SIGNED & SEALED ENGINEERING RECEIVED AND | | | ROUTED TO RECORDS (PAPER) | | | | | 2018-10-04 10:09:03 | 10/2/18 HARD COPIES ROUTED TO SHILL. | | 2018-09-05 13:32:55 | 9/5/18 HARD COPIES ROUTED TO SHILL. LEM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2017-12-06 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2017-12-06 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2017-12-06 |
Time |
16:24 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |