Plan Review Details - Permit 17110377
| Plan Review Stops For Permit 17110377 |
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2018-03-28 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2018-03-28 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2018-03-28 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2018-03-28 13:24:36 | MANUFACURE SPEC/ INSTALLATION MANUAL MUST BE ON-SITE | | | FOR GAS PREESURE REGUALTORS |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2018-03-13 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-03-13 |
Time |
05:41 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-03-13 |
Time |
05:40 |
Sent To |
I |
|
| Notes |
| 2018-03-13 05:41:16 | 1) THERE ARE TWO DIFFERENT GAS DRAWINGS IN THIS | | | SUBMITTAL PACKAGE. ONE SHOWS AN EXISTING GAS SYSTEM AND | | | GAS METER TO WHICH THE GAS LINE FOR THE GENERATOR IS | | | CONNECTED AND THE OTHER SHOWS A NEW GAS METER DEDICATED | | | TO THE GENERATOR. IN ADDITION, THE GAS PERMIT | | | APPLICATION DESCRIPTION OF WORK STATES "TIE INTO | | | EXISTING NG METER FOR GENERATOR INSTALL." ALSO, THE | | | RESPONSE LETTER FROM APS STATES THAT THIS IS A NEWW | | | NATURAL GAS LINE FROM THE METER TO THE GENERATOR ONLY. | | | NO OTHER APPLIANCES ARE ON THIS LINE WITH THE | | | GENERATOR. AT THIS POINT, I HAVE NO IDEA WHAT IS BEING | | | DONE OR HOW DUE TO THE CONFLICTING PLANS AND | | | INFORMATION THAT HAS BEEN SUBMITTED. CLARIFY. | | | 2) REMOVE ALL OLD PLANS AND DOCUMENTS FROM THIS | | | SUBMITTAL AND SUBMIT TWO COMPLETE SETS OF PLANS THAT | | | CLEARLY REFLECT THE SCOPE OF PROPOSED WORK TO BE DONE. | | | WPB AMEND. TO FBC SEC. 107.1, 107.2.1. | | | 3) THE REGULATOR SPECIFICATIONA THAT HAVE BEEN | | | SUBMITTED ARE FOR SERVICE REGULATORS WHICH ARE | | | INSTALLED BY THE GAS SUPPLIER. ARE YOU USING THESE AS | | | THE 2ND STAGE REGULATOR AT THE GENERATOR? CLARIFY. | | | 4) SHEET P1 IS BECOMING DIFFICULT TO READ IN AREAS WITH | | | SMALL PRINTING. SUBMIT TWO COPIES OF A CLEAR AND | | | LEGIBLE PLAN. WPB AMEND. TO FBC SEC. 107.2.1. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2017-11-27 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2017-11-27 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2017-11-27 |
Time |
15:12 |
Sent To |
|
|
| Notes |
| 2017-11-27 15:16:49 | 11-27-2017 1ST GAS REVIEW**DENIED** | | | | | | 1) MISSING SCH 40 METALLIC SIZING TABLE. SUBMIT TWO | | | COPIES OF THE APPLICABLE SIZING TABLES USED TO SIZE THE | | | GAS SYSTEM OR PLACE A NOTE ON THE PLANS/DRAWINGS | | | SPECIFYING WHICH SIZING TABLE(S) FROM THE GAS CODE OR | | | OTHER STANDARD THAT WERE USED IN THE DESIGN OF THIS GAS | | | SYSTEM. REFER TO THE 2014 FBC-FUEL GAS SECS. 401.4, | | | 401.8 THRU 402.6.1 AND TABLES 402.4 (1) THRU 402.4 (37) | | | OR 2014 FBC-RES. SEC. G2412.4, G2412.8, G2413.1, | | | G2413.2, & G2413.3. | | | | | | 2) SUBMIT MANUFACTURER?S SPECIFICATIONS FOR THE | | | PRESSURE REGULATORS. REGULATORS INSTALLED ON THE | | | EXTERIOR OF THE BUILDING SHALL BE APPROVED FOR OUTDOOR | | | INSTALLATION. 2014 FGC SEC.410.1. | | | | | | 3) CITY RECORD SHOWS EXISTING GAS SYSTEM. THE BTU LOAD | | | OF THE EXISTING GAS SYSTEM MUST BE ADDED INTO THE TOTAL | | | BTU LOAD ON THE SYSTEM TO ENSURE THE EXISTING SYSTEM IS | | | PROPERLY SIZED. IF UNDERSIZED, THE EXISTING SYSTEM MUST | | | BE REDONE TO ENSURE A SAFE OPERATING SYSTEM. SUBMIT A | | | GAS PIPING RISER DIAGRAM THAT SHOWS THE TYPE OF | | | EXISTING APPLIANCE, THE BTU LOAD OF EACH APPLIANCE, THE | | | PIPE SIZE AND TYPE OF PIPE TO EACH APPLIANCE, AND THE | | | DISTANCE OF THE LONGEST LENGTH OF PIPING FROM THE POINT | | | OF DELIVERY TO THE MOST REMOTE OUTLET AND THE LOAD OF | | | THE SECTION | | | | | | TIM HUNT | | | PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER | | | CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | 561-805-6695 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-03-28 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2018-03-28 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2018-03-28 |
Time |
13:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-03-13 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-03-13 |
Time |
05:41 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-03-13 |
Time |
05:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-12-20 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2017-12-20 |
Time |
06:18 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2017-12-20 |
Time |
06:18 |
Sent To |
|
|
| Notes |
|
|
|