Plan Review Details - Permit 17110370
| Plan Review Stops For Permit 17110370 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2017-11-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-11-21 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-11-21 |
Time |
10:25 |
Sent To |
G |
|
| Notes |
| 2017-11-21 10:33:02 | SENT TO GAS FOR REVIEW UNDER SUB-PERMIT 17110372. CT |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2017-11-17 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-11-17 |
Time |
12:29 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-11-17 |
Time |
12:29 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2018-02-05 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-02-05 |
Time |
06:35 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-02-05 |
Time |
06:35 |
Sent To |
|
|
| Notes |
| 2018-02-05 06:37:23 | 1/5/18 APPROVED BY PLUMBING, SENT TO PROCESSING, LAC |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-01-19 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2018-01-19 |
Time |
07:33 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2018-01-19 |
Time |
07:33 |
Sent To |
|
|
| Notes |
| 2018-01-19 07:41:56 | 01/19/2018 GAS 2ND REVIEW**FAILED** | | | | | | 1) YOU ARE STILL MISSING THE SIZING TABLE FIR .5LB SCH | | | 40 METAL PIPING. 2ND REQEST.SUBMIT TWO COPIES OF THE | | | APPLICABLE SIZING TABLES USED TO SIZE THE GAS SYSTEM OR | | | PLACE A NOTE ON THE PLANS/DRAWINGS SPECIFYING WHICH | | | SIZING TABLE(S) FROM THE GAS CODE OR OTHER STANDARD | | | THAT WERE USED IN THE DESIGN OF THIS GAS SYSTEM. REFER | | | TO THE 2014 FBC-FUEL GAS SECS. 401.4, 401.8 THRU | | | 402.6.1 AND TABLES 402.4 (1) THRU 402.4 (37) OR 2014 | | | FBC-RES. SEC. G2412.4, G2412.8, G2413.1, G2413.2, & | | | G2413.3. | | | | | | 2) YOUR GAS PRESSURE REGULATORS ARE NOT DESIGNED FOR | | | DOWNSTREAM USAGE AND ALSO MUST COMPLY WITH FUEL AND GAS | | | CODE. SUBMIT MANUFACTURER?S SPECIFICATIONS FOR THE | | | PRESSURE REGULATORS. REGULATORS INSTALLED ON THE | | | EXTERIOR OF THE BUILDING SHALL BE APPROVED FOR OUTDOOR | | | INSTALLATION. 2014 FGC SEC.410.1. | | | | | | 3) SHOW THE DISTANCE OF PIPING FROM THE 2 PSI REGULATOR | | | TO THE APPLIANCE. COMPLY WITH 2014 FBC-FUEL GAS TABLE | | | 402.4 FOR THE PROPER PIPE SIZE AND BTU LOAD. | | | | | | TIM HUNT | | | PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER | | | CITY OF WEST PALM BEACH DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | 561-805-6695 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-02-05 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-02-05 |
Time |
06:35 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-01-31 |
Time |
15:03 |
Sent To |
|
|
| Notes |
| 2018-02-01 15:04:03 | RESUB ROUTED TO THUNT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-01-19 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2018-01-19 |
Time |
07:42 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2018-01-17 |
Time |
11:12 |
Sent To |
|
|
| Notes |
| 2018-01-18 11:12:40 | RESUB ROUTED TO THUNT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-11-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-11-21 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-11-09 |
Time |
09:59 |
Sent To |
G |
|
| Notes |
| 2017-11-13 09:59:29 | ROUTED TO ZONING |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
AW |
Date |
2017-11-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2017-11-14 |
Time |
11:44 |
Sent To |
E |
|
| Notes |
|
|
|