Plan Review Details - Permit 17110339
| Plan Review Stops For Permit 17110339 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-01-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-01-29 |
Time |
11:54 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-01-29 |
Time |
10:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-11-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-11-18 |
Time |
08:12 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-11-18 |
Time |
07:15 |
Sent To |
|
|
| Notes |
| 2017-11-18 08:11:52 | 2014 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 17110339 | | | ADD: 4600 N. FLAGLER DR. | | | CONT: MICHAEL ENNIS CONSTRUCTION CO. | | | TEL: 772-486-2373 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: SAT. NOV. 18/ 2017 | | | ACTION: DENIED | | | | | | 1) IT WOULD APPEAR THE CONTRACTOR NEEDS TO TAKE | | | OWNERSHIP OF THE PLANS, SINCE THE CONSTRUCTION COMPANY | | | NAME APPEARS IN THE TITLE BLOCK. | | | CERTIFICATION BY CONTRACTOR. THE CONTRACTOR (QUALIFIER) | | | THAT CREATED / DRAWN THE SET OF PLANS WILL NEED TO | | | IDENTIFY THEMSELVES AS THE AUTHOR OF THE PLANS. PLEASE | | | PRINT YOUR NAME, SIGN YOUR NAME AND LICENSE NUMBER FOR | | | THE TRADE YOU ARE LICENSED IN AND PLANS DRAWN. | | | 107.3.4.3 CERTIFICATION BY CONTRACTOR. | | | | | | 2) SHEET # 1 THE COVERSHEET INDICATES THE CLOSING IN OF | | | A WINDOW ON A WOOD FRAME STRUCTURE, THE PLANS INDICATE | | | 2 X 6 STUDS TO BE INSTALLED AT 16 INCHES ON CENTER BUT | | | THE PLANS DOES NOT INDICATE HOW THE STUDS WILL BE | | | ANCHORED (STRAPPED) TO THE FRAMING MEMBERS AROUND THE | | | EXISTING WINDOW TO BECOME PART OF THE | | | MAIN WIND FORCE RESISTING SYSTEM (MWFRS)? THE WIND | | | SPEED AT THE JOBSITE LOCATION IS 170 VULT MPH, 3SECOND | | | GUST & EXPOSURE D. | | | | | | 2014 FBC-B 2308.2.1 ULTIMATE DESIGN WIND SPEED GREATER | | | THAN 115 MPH (3-SECOND GUST). | | | WHERE THE ULTIMATE DESIGN WIND SPEED, VULT EXCEEDS 115 | | | MPH (3-SECOND GUST), THE PROVISIONS OF EITHER AF&PA | | | WFCM OR ICC 600 ARE PERMITTED TO BE USED. WIND SPEEDS | | | IN FIGURES 1609A, 1609B, AND 1609C SHALL BE CONVERTED | | | IN ACCORDANCE WITH SECTION 1609.3.1 FOR USE WITH ICC | | | 600. | | | | | | 3) SHEET # 1 THE COVERSHEET INDICATES THE CLOSING IN OF | | | A WINDOW ON A WOOD FRAME STRUCTURE, THE PLANS INDICATE | | | WIRE LATH AND STUCCO TO BE INSTALLED WHERE THE INFILL | | | OF THE WINDOW WILL OCCUR. | | | PLEASE SHOW COMPLIANCE WITH 2 LAYERS OF WATER RESISTANT | | | BARRIERS INSTALLED INDEPENDENTLY. SEE 2014 FBC-B 2510.6 | | | WATER-RESISTANT BARRRIERS. | | | | | | 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2018-03-14 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-03-14 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-03-14 |
Time |
15:20 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-02-07 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-02-07 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-02-07 |
Time |
15:10 |
Sent To |
I |
|
| Notes |
| 2018-02-07 15:10:03 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. NEW COMMENTS | | | ARE ADDED BELOW PREVIOUS COMMENTS. | | | | | | 1. CORRECTED. | | | 2. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4 (NOT | | | PROVIDED.) | | | 3. ALL KITCHEN RECEPTACLE OUTLETS ARE REQUIRED TO BE | | | GFCI PROTECTED. PROVIDE CORRECTION. NEC 210.8 (ONE | | | OUTLET STILL IS SHOWN WITH NO GFCI PROTECTION.) | | | 4. PROVIDE THE ADDITIONAL AUTOMATIC LIGHTING CONTROLS | | | STIPULATED IN THE FBC ENERGY CODE. FBC CE 405.2.2, | | | 405.2.2.2 (NOT PROVIDED.) | | | 5. PROVIDE DETAILS OF THE METHOD OF SHUTDOWN FOR THE | | | ELECTRICAL EQUIPMENT LOCATED UNDER THE HOOD PER NFPA | | | 96. NFPA 96, SECTION 10.4.1, FBC 107.2.1 (NOT | | | PROVIDED.) | | | | | | NEW COMMENTS: | | | | | | 6. PROVIDE LOCATION OF PANEL FOR KITCHEN. FBC 107.2.1 | | | 7. CONDUIT FROM EXTERIOR DISCONNECT TO INTERIOR PANEL | | | IS REQUIRED TO HAVE AN EQUIPMENT GROUNDING CONDUCTOR. | | | PROVIDE CORRECTION. NEC 250.122 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-11-29 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-11-29 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-11-29 |
Time |
07:57 |
Sent To |
I |
|
| Notes |
| 2017-11-29 09:15:51 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. ELECTRICAL PLAN NEEDS TO BE PREPARED BY A DESIGN | | | PROFESSIONAL OR THE ELECTRICAL CONTRACTOR QUALIFIER. | | | PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED AND SEALED | | | BY A LICENSED DESIGN PROFESSIONAL OR THE ELECTRICAL | | | CONTRACTOR QUALIFIER. FS 471.003(2)(H); 471.025; FBC | | | 107.2.1, 107.3.5 | | | 2. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4 | | | 3. ALL KITCHEN RECEPTACLE OUTLETS ARE REQUIRED TO BE | | | GFCI PROTECTED. PROVIDE CORRECTION. NEC 210.8 | | | 4. PROVIDE THE ADDITIONAL AUTOMATIC LIGHTING CONTROLS | | | STIPULATED IN THE FBC ENERGY CODE. FBC CE 405.2.2, | | | 405.2.2.2 | | | 5. PROVIDE DETAILS OF THE METHOD OF SHUTDOWN FOR THE | | | ELECTRICAL EQUIPMENT LOCATED UNDER THE HOOD PER NFPA | | | 96. NFPA 96, SECTION 10.4.1, FBC 107.2.1 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-01-26 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-01-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-01-25 |
Time |
13:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2017-11-14 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-11-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-11-13 |
Time |
15:28 |
Sent To |
|
|
| Notes |
| 2017-11-14 12:51:03 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | 1) PLEASE ENSURE THAT THE LOCKS AND LATCHES ON BOTH | | | EXIT DDORS COMPLY WITH NFPA 101, CHAPTER 7 MEANS OF | | | EGRESS. | | | | | | | | | 7.2.1.5 LOCKS, LATCHES, AND ALARM DEVICES. | | | | | | 7.2.1.5.3 LOCKS, IF PROVIDED, SHALL NOT REQUIRE THE USE | | | OF A KEY, A TOOL, OR SPECIAL KNOWLEDGE OR EFFORT FOR | | | OPERATION FROM THE EGRESS SIDE. | | | | | | 7.2.1.5.5 KEY-OPERATED LOCKS. | | | 7.2.1.5.5.1 EXTERIOR DOOR ASSEMBLIES SHALL BE PERMITTED | | | TO HAVE KEYOPERATED LOCKS FROM THE EGRESS SIDE, | | | PROVIDED THAT ALL OF THE FOLLOWING CRITERIA ARE MET: | | | (1) THIS ALTERNATIVE IS PERMITTED IN CHAPTERS 11 | | | THROUGH 43 FOR THE SPECIFIC OCCUPANCY. | | | (2) A READILY VISIBLE, DURABLE SIGN IN LETTERS NOT LESS | | | THAN 1 IN. (25 MM) HIGH ON A CONTRASTING BACKGROUND | | | THAT READS AS FOLLOWS IS LOCATED ON OR ADJACENT TO THE | | | DOOR LEAF: THIS DOOR TO REMAIN UNLOCKED WHEN THE | | | BUILDING IS | | | OCCUPIED. | | | (3) THE LOCKING DEVICE IS OF A TYPE THAT IS READILY | | | DISTINGUISHABLE AS LOCKED. | | | (4) A KEY IS IMMEDIATELY AVAILABLE TO ANY OCCUPANT | | | INSIDE THE BUILDING WHEN IT IS LOCKED | | | | | | 7.2.1.5.10* A LATCH OR OTHER FASTENING DEVICE ON A DOOR | | | LEAF SHALL BE PROVIDED WITH A RELEASING DEVICE THAT HAS | | | AN OBVIOUS METHOD OF OPERATION AND THAT IS READILY | | | OPERATED UNDER ALL LIGHTING CONDITIONS. | | | 7.2.1.5.10.1 THE RELEASING MECHANISM FOR ANY LATCH | | | SHALL BE LOCATED AS FOLLOWS: | | | (1) NOT LESS THAN 34 IN. (865 MM) ABOVE THE FINISHED | | | FLOOR FOR OTHER THAN EXISTING INSTALLATIONS | | | (2) NOT MORE THAN 48 IN. (1220 MM) ABOVE THE FINISHED | | | FLOOR 7.2.1.5.10.2 THE RELEASING MECHANISM SHALL OPEN | | | THE DOOR LEAF WITH NOT MORE THAN ONE RELEASING | | | OPERATION, UNLESS OTHERWISE SPECIFIED IN 7.2.1.5.10.3, | | | 7.2.1.5.10.4, OR 7.2.1.5.10.6. | | | | | | 7.2.1.5.12* DEVICES SHALL NOT BE INSTALLED IN | | | CONNECTION WITH ANY DOOR ASSEMBLY ON WHICH PANIC | | | HARDWARE OR FIRE EXIT HARDWARE IS REQUIRED WHERE SUCH | | | DEVICES PREVENT OR ARE INTENDED TO PREVENT THE FREE USE | | | OF THE LEAF FOR PURPOSES OF EGRESS, UNLESS OTHERWISE | | | PROVIDED IN 7.2.1.6. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2017-11-28 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-11-28 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-11-28 |
Time |
16:11 |
Sent To |
|
|
| Notes |
| 2017-11-28 16:12:33 | GAS PLAN REVIEW | | | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | | THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE | | | REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK. | | | PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT | | | SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE | | | SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE | | | FBC-R, SEC. G2404.3. | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL | | | GAS SEC. 301.3. | | | | | | A SEPARATE PERMIT IS REQUIRED FOR THE GAS INSTALLATION. | | | | | | | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-03-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-03-12 |
Time |
13:36 |
Sent To |
|
|
| Notes |
| 2018-03-13 13:37:04 | RESUB ROUTED TO JPEARSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-02-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-01-23 |
Time |
11:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-11-29 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-11-29 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-11-08 |
Time |
12:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2017-11-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-11-18 |
Time |
08:12 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-11-18 |
Time |
07:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2018-02-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-02-02 |
Time |
12:11 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-02-02 |
Time |
11:44 |
Sent To |
|
|
| Notes |
| 2018-02-02 12:13:25 | SEPARATE PERMITS FOR GAS AND GAS APPLIANCES, KITCHEN | | | HOOD AND FIRE SUPPRESSION SYSTEM. | | | COMBUSTION AIR CALCULATIONS REQUIRED ON GAS PLAN. | | | | | | CCOLE-2/2/18 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-11-18 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-11-18 |
Time |
09:08 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-11-18 |
Time |
09:08 |
Sent To |
|
|
| Notes |
| 2017-11-18 09:12:22 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #17110339 | | | 11/18/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHOW THE MECHANICAL ALTERATIONS RELATED TO THE | | | DEMOLITION AND RECONFIGURATION OF THE NEW KITCHEN. | | | | | | 2) ADVISORY: SEPARATE PERMITS ARE REQUIRED FOR KITCHEN | | | EXHAUST HOODS AND FIRE SUPPRESSION SYSTEMS- SECTION | | | 107.2.1 WPB AMENDMENTS TO THE FBC. COMPLIANCE WITH | | | SECTION 508.1.1 MAKEUP AIR TEMPERATURE WILL BE | | | REQUIRED. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | BUILDING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-02-07 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-02-07 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-02-07 |
Time |
14:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-11-28 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-11-28 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-11-28 |
Time |
15:14 |
Sent To |
|
|
| Notes |
| 2017-11-28 16:11:48 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. THE GREASE INTERCEPTOR SPECIFICATIONS AND SANITARY | | | RISER ARE TO SMALL PLEASE ENLARGE ON PLAN SHEET. PER | | | WPB AMEND TO FBC 107.2.1.4 QUALITY OF BUILDING PLANS. | | | BUILDING PLANS SHALL BE DRAWN TO A MINIMUM 1/8 INCH | | | SCALE UPON SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE | | | MEDIUM. THE BUILDING OFFICIAL MAY | | | ESTABLISH THROUGH DEPARTMENTAL POLICY, OTHER STANDARDS | | | FOR PLANS AND SPECIFICATIONS, IN | | | ORDER TO PROVIDE CONFORMITY TO ITS RECORD RETENTION | | | PROGRAM. THIS POLICY MAY INCLUDE SUCH | | | THINGS AS MINIMUM SIZE, SHAPE, CONTRAST, CLARITY, OR | | | OTHER ITEMS RELATED TO RECORDS | | | MANAGEMENT. ELECTRONIC MEDIA MUST BE COMPATIBLE WITH | | | THE ARCHIVE REQUIREMENTS OF | | | FLORIDA STATUTES. | | | | | | 2. PLEASE PROVIDE MANUFACTURE SIZING CALCULATIONS FOR | | | GREASE INTERCEPTOR. PER FBC PL 1003.2 | | | | | | 3. THE RISER DIAGRAM DOES NOT MATCH FLOOR PLAN THE HAND | | | SINK IS NOT SHOWN ON FLOOR PLAN AND THE 3" VENT IS NOT | | | SHOWN ON RISER. PER WPB AMEND TO FBC 107.2.1 | | | | | | 4. A TRAP PRIMER IS REQUIRED ON FLOOR DRAINS. PER FBC | | | PL 1002.4 | | | | | | 5. PLEASE PROVIDE WATER RISER DIAGRAM. PER WPB AMEND TO | | | FBC 107.3.5.1.3(13) | | | | | | 6. SHOW LOCATION OF WATER HEATER ON PLAN SHALL COMPLY | | | WITH FBC PL 607.2 HOT OR TEMPERED WATER SUPPLY TO | | | FIXTURES. | | | THE DEVELOPED LENGTH OF HOT OR TEMPERED WATER PIPING, | | | FROM THE SOURCE OF HOT WATER TO THE FIXTURES THAT | | | REQUIRE HOT OR TEMPERED WATER, SHALL NOT EXCEED 50 FEET | | | (15 240 MM). RECIRCULATING SYSTEM PIPING AND | | | HEAT-TRACED PIPING SHALL BE CONSIDERED TO BE SOURCES OF | | | HOT OR TEMPERED WATER. | | | | | | 7. A CLEANOUT IS REQUIRED ON INLET SIDE OF GREASE | | | INTERCEPTOR AND A TESTPORT/ CLEAN OUT MIN 4" REQUIRED | | | ON OUTLET SIDE. PER WPB UTILITIES DEPT. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P-GREASE |
GREASE INTERCEPTOR/TRAP REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2018-02-07 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-02-07 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-02-07 |
Time |
14:01 |
Sent To |
|
|
| Notes |
|
|
|