Plan Review Details - Permit 17110126
| Plan Review Stops For Permit 17110126 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2019-02-14 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-02-14 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-02-14 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2019-02-14 13:58:53 | *PROVISO* | | | | | | PROVIDE THE REQUIERED TEST REPORTS FOR THE SPECIFIC | | | CONDITIONS FOR THIS JOB. THIS CAN PERFORMED ON SITE AND | | | CERTIFIED BY AN ENGINEER. | | | | | | | | | A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING | | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR | | | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90. | | | THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM | | | CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | | | B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN | | | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC | | | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN | | | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN | | | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH | | | ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED | | | GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | | | C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE | | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | | OR UL 723. | | | | | | | | | . | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
F |
Date |
2019-02-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-02-04 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-02-04 |
Time |
08:15 |
Sent To |
|
|
| Notes |
| 2019-02-04 08:18:17 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | COURTESY REVIEW VIA EMAIL: | | | | | | 1. THE FLOORING SPEC SHEETS (PARKAY FLOORS) DOES NOT | | | APPEAR TO BE TESTED TO THE REQUIRED STANDARD, ASTME-84 | | | (SEE PREVIOUS COMMENT LISTS). | | | | | | 2. THE UNDERLAYMENT TEST REPORTS USED A DROPPED GYPSUM | | | CEILING WHICH IS NOT YOUR JOB CONDITION. EITHER PROVIDE | | | A TEST REPORT OR A COMPARATIVE ANALYSIS. | | | | | | 3. ASTM E-84 TEST REPORT FOR FLOOR MUFFLER WAS SENT TO | | | RICHARD MCCALLA VIA EMAIL. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
F |
Date |
2019-01-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-01-04 |
Time |
07:11 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-01-04 |
Time |
07:11 |
Sent To |
|
|
| Notes |
| 2019-01-04 07:11:39 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | FROM PREVIOUS LISTS: PLEASE DO NOT RESUBMIT WITHOUT | | | THIS INFORMATION!! PLEASE CONTACT ME IF YOU NEED | | | ASSISTANCE!! | | | | | | 7TH REVIEW - THE TEST REPORTS PROVIDED FOR "MASTERS | | | BUILDING PRODUCTS" (STAPLED TO SPEC SHEET FOR | | | "SOUNDGUARD") USED AN ASSEMBLY WITH A DROPPED GYPSUM | | | CEILING. FLAME SPREAD TEST NOT PROVIDED. | | | | | | "QUIET WALK PLUS" SPEC SHEET WAS ALSO PROVIDED; NO TEST | | | REPORTS WERE PROVIDED WITH THE SPEC SHEET. | | | | | | PLEASE SEE PREVIOUS SIX COMMENT LISTS REGARDING THE | | | THREE TEST REPORTS REQUIRED FOR FLOORING UNDERLAYMENT. | | | PLEASE CONTACT ME IF YOU NEED ASSISTANCE. | | | | | | THIS INFORMATION CAN BE SENT VIA EMAIL RATHER THAN | | | RESUBMITTAL; INCLUDE PERMIT NUMBER AND "FLOORING | | | UNDERLAYMENT" IN THE SUBJECT LINE. | | | | | | 2. TILE IS PROPOSED ON 1ST FLOOR, VINYL ON 2ND FLOOR. | | | | | | A. FBC B 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING | | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR | | | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90. | | | THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM | | | CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | | | B. FBC B 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN | | | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC | | | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN | | | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN | | | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH | | | ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED | | | GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | | | C. FBC B 720.2, SOUND-INSULATING MATERIALS TO HAVE A | | | FLAME SPREAD INDEX OF NOT MORE THAN 25, SMOKE-DEVELOPED | | | INDEX NOT MORE THAN 450. (NOTE THAT THIS CODE REFERENCE | | | HAS BEEN CORRECTED TO REFLECT COMBUSTIBLE | | | CONSTRUCTION). | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2018-12-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-12-05 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-12-05 |
Time |
15:05 |
Sent To |
|
|
| Notes |
| 2018-12-05 15:05:31 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | FROM PREVIOUS LISTS: PLEASE DO NOT RESUBMIT WITHOUT | | | THIS INFORMATION!! PLEASE CONTACT ME IF YOU NEED | | | ASSISTANCE!! | | | | | | 2. TILE IS PROPOSED ON 1ST FLOOR, VINYL ON 2ND FLOOR. | | | | | | RESPONSE LETTER STATES THAT THE FLOORING UNDERLAYMENT | | | INFO IS ATTACHED, BUT I WAS NOT ABLE TO LOCATE IT. | | | PROVIDE THE FOLLOWING TEST REPORTS: | | | | | | A. FBC B 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING | | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR | | | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90. | | | THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM | | | CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | | | B. FBC B 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN | | | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC | | | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN | | | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN | | | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH | | | ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED | | | GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | | | C. FBC B 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25. SEE | | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | | OR UL 723. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2018-09-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-25 |
Time |
18:04 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-09-25 |
Time |
18:04 |
Sent To |
|
|
| Notes |
| 2018-09-25 18:06:02 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. OK | | | | | | 2. TILE IS PROPOSED ON 1ST FLOOR, VINYL ON 2ND FLOOR. | | | | | | RESPONSE LETTER STATES THAT THE FLOORING UNDERLAYMENT | | | INFO IS ATTACHED, BUT I WAS NOT ABLE TO LOCATE IT. | | | PROVIDE THE FOLLOWING TEST REPORTS: | | | | | | A. FBC B 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING | | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR | | | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90. | | | THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM | | | CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | | | B. FBC B 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN | | | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC | | | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN | | | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN | | | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH | | | ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED | | | GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | | | C. FBC B 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25. SEE | | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | | OR UL 723. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2018-05-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-05-13 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-05-13 |
Time |
10:00 |
Sent To |
|
|
| Notes |
| 2018-05-13 10:15:04 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. A0 INDICATES THE BUILDING TYPE AS IIB. PLEASE ADVISE | | | AS TO HOW ENGINEER HAS MADE THIS DETERMINATION. OUR | | | RECORDS SHOW TWO RECORDS RESEARCH REQUESTS DONE IN | | | 2/2017 AND 9/2017, AND THE RECORDS SHOW WOOD FRAME IN | | | THIS STRUCTURE. ALSO, THE ROOF PERMIT 98090008 HAS A | | | SPECIFICATION FOR A NAILABLE DECK. | | | | | | THE PREVIOUS REVIEWER RELIED ON THIS INFORMATION WHEN | | | DOING THE REVIEW. FOR A COMBUSTIBLE BUILDING, THE FLAME | | | SPREAD FOR THE FLOORING UNDERLAYMENT HAS A MORE | | | STRINGENT REQUIREMENT OF 25 AS OPPOSED TO 200 FOR TYPE | | | I/TYPE II BUILDINGS. | | | | | | WITHOUT ACCURATE INFORMATION, AN ACCURATE CHECKLIST | | | CANNOT BE PROVIDED AT THIS TIME. HAS ENGINEER BEEN TO | | | THIS JOB? PROVIDE INFORMATION REGARDING WALL | | | CONTRUCTION, FLOOR CONSTRUCTION, ROOF CONSTRUCTION. | | | | | | 2. FLOORING PROPOSED IS NOT CLEAR. PLEASE ADVISE. A | | | FLOORING UNDERLAYMENT CANNOT BE REVIEWED UNTIL THE | | | FLOOR CONSTRUCTION AND FLOORING PROPOSED IS DETERMINED. | | | | | | PLEASE NOTE THAT VERY FEW PRODUCTS HAVE THE THREE TESTS | | | REQUIRED. | | | | | | TEST REPORTS ARE REQUIRED - MANUFACTURER SPEC SHEETS | | | ARE NOT ACCEPTABLE DUE TO DISCREPANCIES BETWEEN SPEC | | | SHEETS/BROCHURES AND TEST REPORTS FOR SOME | | | MANUFACTURERS (NOT NECESSARILY THE MANUFACTURER | | | SELECTED; THIS IS A GENERAL COMMENT) | | | | | | A. FBC B 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING | | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR | | | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90. | | | THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM | | | CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | | | B. FBC B 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN | | | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC | | | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN | | | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN | | | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH | | | ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED | | | GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | | | C. FBC B 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE | | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | | OR UL 723. | | | | | | EXCEPTION IN FBC B 603.1 IS FOR BUILDING TYPE I & II. | | | IF THE BUILDING IS III, IV, V, PER FBC B 720.2 FLAME | | | SPREAD LESS THAN 25 IS REQUIRED. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2018-02-23 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-02-23 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-02-23 |
Time |
09:38 |
Sent To |
|
|
| Notes |
| 2018-02-23 10:28:39 | ****PLAN REVIEW COMMENTS**** | | | | | | ART LANGE BUILDING PLANS EXAMINER | | | | | | DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FL 33402 | | | | | | 561-805-6667 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2014 5TH EDITION/ FRC FLORIDA | | | RESIDENTIAL CODE 2015 5TH EDITION | | | | | | THIRD REVIEW: | | | | | | SANE COMMENT: | | | | | | 1. PROVIDE TWO COPIES OF THE SOUND PROOFING | | | SPECIFICATIONS FOR THE SECOND FLOOR APARTMENTS THAT | | | SHOW COMPLIANCE WITH THE FOLLOWING STANDARDS. | | | | | | FBC 1207.3 STRUCTURE-BORNE SOUND. ASTM E - 492-09 | | | | | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | | | | ALTERNATIVELY YOU CAN SUBMIT THESE LATER AS A DEFERRED | | | SUBMITTAL BY LISTING THEM ON THE COVER SHEET. | | | | | | 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS | | | SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS | | | FOR REVIEW BY THE BUILDING OFFICIAL. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | | | | NEW COMMENT: | | | | | | A. ON PAGE A.0 THE BUILDING DEPARTMENT IS SHOWN IN | | | HIALEAH GARDE, FL.. PLEASE UPDATE ADDRESS TO 401 | | | CLEMATIS ST. WEST PALM BEACH, FL 33402 FBC 107.2.1 | | | | | | | | | | | | | | | WHEN RESUBMITTING, PLEASE COMPLETE A RESUBMITTAL FORM: | | | | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | THIS FORM IS ALSO AVAILABLE AT THE BUILDING DIVISION. | | | WHEN RESUBMITTING, SWAP OUT SHEETS WHICH HAVE CHANGED | | | SO THAT THERE ARE TWO COMPLETE, COLLATED SETS OF PLANS | | | READY FOR PERMIT ISSUANCE. OLD SHEETS ARE TO BE | | | RETAINED IN THE PERMIT APPLICATION PACKAGE (SEPARATE | | | FROM THE PERMIT SETS) AND MARKED *OLD SHEETS* OR | | | *VOID*. PLEASE KEEP BOTH SETS OF OLD VOIDED SHEETS IN | | | THE PERMIT PACKAGE. | | | | | | A RESPONSE LETTER INDICATING HOW EACH ITEM WAS | | | ADDRESSED WILL HELP TO EXPEDITE PLAN REVIEW. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2017-12-27 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2017-12-27 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2017-12-27 |
Time |
07:46 |
Sent To |
|
|
| Notes |
| 2017-12-27 09:14:03 | ****PLAN REVIEW COMMENTS**** | | | | | | ART LANGE BUILDING PLANS EXAMINER | | | | | | DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FL 33402 | | | | | | 561-805-6667 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2014 5TH EDITION/ FRC FLORIDA | | | RESIDENTIAL CODE 2015 5TH EDITION | | | | | | SECOND REVIEW: | | | | | | 1. PROVIDE TWO COPIES OF THE SOUND PROOFING | | | SPECIFICATIONS FOR THE SECOND FLOOR APARTMENTS THAT | | | SHOW COMPLIANCE WITH THE FOLLOWING STANDARDS. | | | | | | FBC 1207.3 STRUCTURE-BORNE SOUND. ASTM E - 492-09 | | | | | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | | | | | | | 2. OK ADDRESSED. | | | | | | 3. PERMIT VALUE ADJUSTED PER ESTIMATE SUBMITTED. OK. | | | | | | 4. OK ADDRESSED. | | | | | | | | | | | | WHEN RESUBMITTING, PLEASE COMPLETE A RESUBMITTAL FORM: | | | | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | THIS FORM IS ALSO AVAILABLE AT THE BUILDING DIVISION. | | | WHEN RESUBMITTING, SWAP OUT SHEETS WHICH HAVE CHANGED | | | SO THAT THERE ARE TWO COMPLETE, COLLATED SETS OF PLANS | | | READY FOR PERMIT ISSUANCE. OLD SHEETS ARE TO BE | | | RETAINED IN THE PERMIT APPLICATION PACKAGE (SEPARATE | | | FROM THE PERMIT SETS) AND MARKED *OLD SHEETS* OR | | | *VOID*. PLEASE KEEP BOTH SETS OF OLD VOIDED SHEETS IN | | | THE PERMIT PACKAGE. | | | | | | A RESPONSE LETTER INDICATING HOW EACH ITEM WAS | | | ADDRESSED WILL HELP TO EXPEDITE PLAN REVIEW. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-11-14 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2017-11-14 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2017-11-14 |
Time |
10:52 |
Sent To |
|
|
| Notes |
| 2017-11-14 12:31:16 | ****PLAN REVIEW COMMENTS**** | | | | | | ART LANGE BUILDING PLANS EXAMINER | | | 561-805-6667 [email protected] | | | FBC FLORIDA BUILDING CODE 2014 5TH EDITION/ FRC FLORIDA | | | RESIDENTIAL CODE 2015 5TH EDITION | | | | | | 1. PROVIDE TWO COPIES OF THE SOUND PROOFING | | | SPECIFICATIONS FOR THE SECOND FLOOR APARTMENTS. | | | | | | FBC 1207.3 STRUCTURE-BORNE SOUND. ASTM E - 492-09 | | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | FBC-107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. ALL | | | INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING | | | DATA SHALL BEAR THE NAME AND SIGNATURE OF THE PERSON | | | RESPONSIBLE FOR THE DESIGN. | | | | | | 2. PERMIT VALUE TOO LOW. ADJUST PERMIT VALUE. FBC 109.3 | | | BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF THE | | | BUILDING OFFICIAL, THE CLAIMED VALUATION OF BUILDING, | | | ALTERATION, STRUCTURE, ELECTRICAL, GAS, MECHANICAL OR | | | PLUMBING SYSTEMS APPEARS TO BE UNDERESTIMATED ON THE | | | APPLICATION, THE PERMIT SHALL BE DENIED, UNLESS THE | | | APPLICANT CAN SHOW DETAILED, QUANTITY ESTIMATES, AND/OR | | | BONA FIDE SIGNED CONTRACTS (EXCLUDING LAND VALUE) TO | | | MEET THE APPROVAL OF THE BUILDING OFFICIAL. FOR | | | PERMITTING PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS | | | SHALL BE TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY | | | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST | | | PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS | | | SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | | INTERNATIONAL CODE CONGRESS. | | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | | BUILDING OFFICIAL. | | | | | | 3. SINCE THE VALUE OF THE PROJECT WILL BE ABOVE $25,000 | | | A DESIGN PROFESSIONAL IS REQUIRED. | | | DESIGN PROFESSIONAL ? REQUIRED | | | PURSUANT TO FBC 107.1, AND FS 481.229 (1) (C), AS THIS | | | DESIGN EXCEEDS $25,000.00 IN VALUE, THE DESIGN MUST BE | | | PREPARED BY A LICENSED PROFESSIONAL PURSUANT TO FS 481. | | | SEE BELOW: | | | | | | FBC107.1 GENERAL. SUBMITTAL DOCUMENTS CONSISTING OF | | | CONSTRUCTION DOCUMENTS, STATEMENT OF SPECIAL | | | INSPECTIONS, GEOTECHNICAL REPORT AND OTHER DATA SHALL | | | BE SUBMITTED IN TWO OR MORE SETS WITH EACH PERMIT | | | APPLICATION. | | | | | | THE CONSTRUCTION DOCUMENTS SHALL BE PREPARED BY A | | | REGISTERED DESIGN PROFESSIONAL WHERE REQUIRED BY | | | CHAPTER 471, FLORIDA STATUTES& 61G15 FLORIDA | | | ADMINISTRATIVE CODE OR CHAPTER 481, FLORIDA STATUTES& | | | 61G1 FLORIDA ADMINISTRATIVE CODE. | | | | | | WHERE SPECIAL CONDITIONS EXIST, THE BUILDING OFFICIAL | | | IS AUTHORIZED TO REQUIRE ADDITIONAL CONSTRUCTION | | | DOCUMENTS TO BE PREPARED BY A REGISTERED DESIGN | | | PROFESSIONAL. ELECTRONIC MEDIA DOCUMENTS SHALL BE | | | SUBMITTED WHEN REQUIRED BY THE BUILDING OFFICIAL, AND | | | MAY REQUIRE ONLY ONE SET OF SUBMITTALS. | | | PLANS THAT HAVE BEEN PREPARED BY AN ENGINEER AND | | | SUBMITTED FOR PUBLIC RECORD SHALL BEAR THE SIGNATURE, | | | DATE AND SEAL OF THE ENGINEER PER FL ADMIN. CODE RULE | | | 61G15-23.001. | | | DESIGN PROFESSIONAL ? EXCEPTIONS | | | | | | FS 481.229 -EXCEPTIONS; EXEMPTIONS FROM LICENSURE. | | | | | | (1) NO PERSON SHALL BE REQUIRED TO QUALIFY AS AN | | | ARCHITECT IN ORDER TO MAKE PLANS AND SPECIFICATIONS | | | FOR, OR SUPERVISE THE ERECTION, ENLARGEMENT, OR | | | ALTERATION OF: | | | | | | (A) ANY BUILDING UPON ANY FARM FOR THE USE OF ANY | | | FARMER, REGARDLESS OF THE COST OF THE BUILDING; | | | | | | (B) ANY ONE-FAMILY OR TWO-FAMILY RESIDENCE BUILDING, | | | TOWNHOUSE, OR DOMESTIC OUTBUILDING APPURTENANT TO ANY | | | ONE-FAMILY OR TWO-FAMILY RESIDENCE, REGARDLESS OF COST; | | | OR | | | | | | (C) ANY OTHER TYPE OF BUILDING COSTING LESS THAN | | | $25,000, EXCEPT A SCHOOL, AUDITORIUM, OR OTHER BUILDING | | | INTENDED FOR PUBLIC USE, PROVIDED THAT THE SERVICES OF | | | A REGISTERED ARCHITECT SHALL NOT BE REQUIRED FOR MINOR | | | SCHOOL PROJECTS PURSUANT TO S. 1013.45. | | | | | | 4. NOTE SHOWN ON A-3 OTHER AREAS AFFECTED BY THE | | | ALTERATION. PROVIDE ADDITIONAL INFORMATION. | | | WILL FRAMING, DRYWALL OR INSULATION BE PART OF THIS | | | PROJECT? IF SO SHOW ON PLANS THE LOCATION AND EXTENT OF | | | THIS WORK. SHOW THE EXTERIOR WORK THAT WILL BE | | | COMPLETED. | | | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | | UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE | | | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE | | | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT | | | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL. | | | | | | | | | | | | WHEN RESUBMITTING, PLEASE COMPLETE A RESUBMITTAL FORM: | | | | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | THIS FORM IS ALSO AVAILABLE AT THE BUILDING DIVISION. | | | WHEN RESUBMITTING, SWAP OUT SHEETS WHICH HAVE CHANGED | | | SO THAT THERE ARE TWO COMPLETE, COLLATED SETS OF PLANS | | | READY FOR PERMIT ISSUANCE. OLD SHEETS ARE TO BE | | | RETAINED IN THE PERMIT APPLICATION PACKAGE (SEPARATE | | | FROM THE PERMIT SETS) AND MARKED *OLD SHEETS* OR | | | *VOID*. PLEASE KEEP BOTH SETS OF OLD VOIDED SHEETS IN | | | THE PERMIT PACKAGE. | | | | | | A RESPONSE LETTER INDICATING HOW EACH ITEM WAS | | | ADDRESSED WILL HELP TO EXPEDITE PLAN REVIEW. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2018-12-20 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-12-20 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-12-20 |
Time |
10:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2018-11-05 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-11-05 |
Time |
17:09 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-11-05 |
Time |
17:09 |
Sent To |
|
|
| Notes |
| 2018-11-05 17:09:46 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: NEW REVIEW BASED ON DESIGN | | | PROFESSIONAL CHANGE. DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. PROVIDE ACCURATE LOAD CALCULATION TO JUSTIFY SERVICE | | | SIZE. LOAD CALCULATION PROVIDED IS NOT CODE COMPLIANT. | | | NEC 220 (LOAD CALCULATION FOR MAIN NOT PROVIDED. LOAD | | | CALCULATION FOR PANELS DOES NOT MATCH LOADS SPECIFIED | | | IN PANEL SCHEDULE ON SHEET E-1. PROVIDE AS PREVIOUSLY | | | REQUESTED.) | | | 2. BASED ON LOADS PROVIDED, SERVICE IS NOT OF | | | SUFFICIENT SIZE FOR THE LOAD. PROVIDE CORRECTION. NEC | | | 215.2, 215.3, 408.30, 408.36 (NOT CORRECTED, SEE NOTE | | | 1) | | | 3. BASED ON LOADS PROVIDED, FEEDERS TO FPL ARE NOT | | | SIZED PROPERLY. PROVIDE CORRECTION. NEC 310.15(B)(16) | | | (ONCE LOAD IS CALCULATED PROPERLY, SIZE FEEDERS | | | APPRORIATELY.) | | | 4. PROVIDE CALCULATION FOR WIRE SIZE TO METERS/ METER | | | BANKS. NEC 220, 215.2, 215.3, 240.21 (NOT PROVIDED.) | | | 5. PROVIDE METHOD OF TAPPING WIRES TO EACH METER. AS | | | SHOWN ON PLAN, THE WIRES WOULD GO TO INDIVIDUAL METERS. | | | HOW WOULD THIS BE ACCOMPLISHED? IF A TAP IS TO BE USED, | | | TAP RULES DICTATE THAT THE TAPS MUST TERMINTATE IN A | | | SINGLE BREAKER OR SET OF FUSES. PROVIDE COMPLIANCE. NEC | | | 240.21(B)(5); WPB FBC 107.2.1 (NOT CORRECTED.) | | | 6. SHEET E-1 SHOWS UNIT TYPES A, B, AND C. SHEET E-3 | | | SHOWS UNIT TYPES A AND B. ATTEMPTED LOAD CALCULATION | | | SHOWS 3 TYPES OF UNITS. PROVIDE CLARIFICATION AND/OR | | | CORRECTION. WPB FBC 107.2.1 (NOT CORRECTED.) | | | 7. PROVIDE ACCURATE SIZED GROUNDING ELECTRODE | | | CONDUCTOR. NEC 250.66 (CANNOT BE DETERMINED UNTIL LOAD | | | IS CALCULATED PROPERLY.) | | | 8. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10 (NOT PROVIDED.) | | | 9. PROVIDE AIC RATING OF SERVICE DISCONNECT AND PANELS. | | | NEC 110.3, 110.9 (NOT PROVIDED.) | | | 10. PROVIDE NOTES TO INDICATE THE REQUIRED MARKING OF | | | SERVICE EQUIPMENT FOR ARC FLASH HAZARD WARNING AND | | | AVAILABLE FAULT CURRENT PER CODE. NEC 110.16, 110.24 | | | (NOT PROVIDED.) | | | 11. PROVIDE SPEC SHEET FOR 4000 VA RANGE SPECIFIED IN | | | LOAD CALCULATIONS. NEC 110.3 (NOT PROVIDED. LOAD | | | CALCULATION NOW SHOWS 8000 VA FOR RANGE, PANEL SCHEDULE | | | SHOWS 4000 VA. PROVIDE CLARIFICATION AND/OR | | | CORRECTION.) | | | | | | BE ADVISED THAT THERE SEEMS TO BE A SUBSTANTIAL AMOUNT | | | OF INFORMATION INCORRECT AND/OR MISSING WITH THIS PLAN. | | | FUTURE ADDITIONAL COMMENTS ARE POSSIBLE WHEN THE | | | INFORMATION ABOVE IS SUPPLIED. | | | | | | NEW COMMENTS: | | | | | | 12. NEW RISER SHOWS 2 - 500 MCM WIRES TO MAIN | | | DISCONNECT FUSED AT 650 AMP. THERE SHOULD BE A MINIMUM | | | OF 3 WIRES IN A SINGLE PHASE SERVICE. THIS WIRE SIZE IS | | | NOT RATED FOR 650 AMPS. A 650 AMP FUSE IS NOT A | | | STANDARD FUSE SIZE PER NEC 240.6, PROVIDE DETAILS. | | | PROVIDE SIZE AND AIC RATING OF MAIN DISCONNECT. NEC | | | 110.3, 215.5, 220.5, 240.6, 310.15; WPB FBC 107.2.1 | | | 13. IT APPEARS THAT THERE IS NOT AN EQUIPMENT GROUNDING | | | CONDUCTOR IN THE CONDUITS ON THE LOAD SIDE OF THE | | | SERVICE DISCONNECTING MEANS. A GROUNDED CIRCUIT | | | CONDUCTOR IS NOT PERMITTED TO FUNCTION AS THE EQUIPMENT | | | GROUNDING CONDUCTOR. PROVIDE CORRECTION. NEC 250.142(B) | | | 14. CONDUIT SIZES SPECIFIED FOR FEEDERS IS NOT CODE | | | COMPLIANT. PROVIDE CORRECTION. NEC TABLE 1 AND 4, | | | INFORMATIVE ANNEX C. | | | 15. PLEASE BE ADVISED THAT SOME OF THESE COMMENTS HAVE | | | NOT BEEN ADDRESSED FOR TWO REVIEWS. IF UPON THE NEXT | | | REVIEW, IF IT IS NECESSARY TO REJECT THE SUBMITTED PLAN | | | A THIRD TIME FOR THE SAME REASONS, AN ADDITIONAL PLAN | | | REVIEW IS REQUIRED. FLORIDA STATUTES STATE: WITH | | | RESPECT TO EVALUATION OF DESIGN PROFESSIONALS | | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. FS 553.80(2)(B) | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2018-09-18 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-09-18 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-09-18 |
Time |
08:17 |
Sent To |
|
|
| Notes |
| 2018-09-18 11:06:14 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: NEW REVIEW BASED ON DESIGN | | | PROFESSIONAL CHANGE. DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE ACCURATE LOAD CALCULATION TO JUSTIFY SERVICE | | | SIZE. LOAD CALCULATION PROVIDED IS NOT CODE COMPLIANT. | | | NEC 220 | | | 2. BASED ON LOADS PROVIDED, SERVICE IS NOT OF | | | SUFFICIENT SIZE FOR THE LOAD. PROVIDE CORRECTION. NEC | | | 215.2, 215.3, 408.30, 408.36 | | | 3. BASED ON LOADS PROVIDED, FEEDERS TO FPL ARE NOT | | | SIZED PROPERLY. PROVIDE CORRECTION. NEC 310.15(B)(16) | | | 4. PROVIDE CALCULATION FOR WIRE SIZE TO METERS/ METER | | | BANKS. NEC 220, 215.2, 215.3, 240.21 | | | 5. PROVIDE METHOD OF TAPPING WIRES TO EACH METER. AS | | | SHOWN ON PLAN, THE WIRES WOULD GO TO INDIVIDUAL METERS. | | | HOW WOULD THIS BE ACCOMPLISHED? IF A TAP IS TO BE USED, | | | TAP RULES DICTATE THAT THE TAPS MUST TERMINTATE IN A | | | SINGLE BREAKER OR SET OF FUSES. PROVIDE COMPLIANCE. NEC | | | 240.21(B)(5); WPB FBC 107.2.1 | | | 6. SHEET E-1 SHOWS UNIT TYPES A, B, AND C. SHEET E-3 | | | SHOWS UNIT TYPES A AND B. ATTEMPTED LOAD CALCULATION | | | SHOWS 3 TYPES OF UNITS. PROVIDE CLARIFICATION AND/OR | | | CORRECTION. WPB FBC 107.2.1 | | | 7. PROVIDE ACCURATE SIZED GROUNDING ELECTRODE | | | CONDUCTOR. NEC 250.66 | | | 8. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10 | | | 9. PROVIDE AIC RATING OF SERVICE DISCONNECT AND PANELS. | | | NEC 110.3, 110.9 | | | 10. PROVIDE NOTES TO INDICATE THE REQUIRED MARKING OF | | | SERVICE EQUIPMENT FOR ARC FLASH HAZARD WARNING AND | | | AVAILABLE FAULT CURRENT PER CODE. NEC 110.16, 110.24 | | | 11. PROVIDE SPEC SHEET FOR 4000 VA RANGE SPECIFIED IN | | | LOAD CALCULATIONS. NEC 110.3 | | | | | | BE ADVISED THAT THERE SEEMS TO BE A SUBSTANTIAL AMOUNT | | | OF INFORMATION INCORRECT AND/OR MISSING WITH THIS PLAN. | | | FUTURE ADDITIONAL COMMENTS ARE POSSIBLE WHEN THE | | | INFORMATION ABOVE IS SUPPLIED. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2018-05-08 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-05-08 |
Time |
07:28 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-05-07 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2018-05-07 17:19:22 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY HAVE BEEN NOTED AS CORRECTED. ITEMS | | | REMAINING HAVE FURTHER COMMENTS IN PARENTHESES. | | | | | | 1. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | | LOADS. THE LOAD CALCULATION PROVIDED USED A DEMAND | | | FACTOR FOR EACH UNIT, AND THEN USED THOSE NUMBERS TO | | | APPLY A SECOND DEMAND FACTOR FOR MULTI-FAMILY | | | DWELLINGS, WHICH IS NOT PERMITTED. ADDITIONALLY, I DO | | | NOT SEE ANY HOUSE PANEL LOADS ADDED. WILL THERE BE ANY | | | HOUSE LOADS INCLUDING LIGHTING OF EXTERIOR? FBC | | | 107.2.1; NEC 220.40 (NEC 220.83 CANNOT BE USED FOR THIS | | | PROJECT, IT IS ONLY FOR A ONE FAMILY DWELLING WHERE | | | LOAD IS TO BE ADDED. PROVIDE ACCURATE LOAD CALCULATION | | | AS REQUESTED.)(4TH REVIEW, LOAD CALCULCATION NOT | | | CORRECT. MATH FOR EACH COLUMN IS NOT TOTALED CORRECTLY, | | | RESULTING IN A FINAL NUMBER THAT IS INCORRECT. IT IS | | | RECOMMENDED THAT THE DESIGN PROFESSIONAL MAKE AN | | | APPOINTMENT TO MEET WITH PLAN REVIEWER.) | | | 2. CORRECTED. | | | 3. BASED ON THE LOADS PROVIDED, THE PROPOSED SERVICE IS | | | NOT ADEQUATE FOR THE LOADS. PROVIDE CORRECTION. NEC | | | 215.2, 215.3, 220.40 (BASED ON MY CALCULATION FROM THE | | | LOADS PROVIDED ON PLAN, THE MINIMUM SERVICE WOULD NEED | | | TO HAVE A CAPACITY OF AT LEAST 886 AMPS. SERVICE | | | DESIGNED IS NOT ADEQUATE FOR THE LOADS SPECIFIED.)(4TH | | | REVIEW, LOAD CALCULATION PROVIDED, WHICH IS INCORRECT, | | | CALLED FOR A 900 AMP SERVICE, BUT THE PLAN SHOWS AN 800 | | | AMP SERVICE. THIS ITEM STILL NEEDS CORRECTION.) | | | 4. PROVIDE ACCURATE RISER DIAGRAM. BASED ON SITE VISIT, | | | THE EXISTING MAIN IS 400 AMPS, NOT 800. IS THE PROPOSED | | | SERVICE JUST A DISCONNECT, OR DOES IT HAVE BREAKERS | | | THAT FEED THE METER STACKS? HOW ARE THE METER STACKS | | | FED? IS THERE A GUTTER WITH TAPS? WHAT IS THE PHYSICAL | | | LOCATION OF ALL THE METERS? RISER PROVIDED DOES NOT | | | HAVE ENOUGH INFORMATION. PROVIDE CLARIFICATION. FBC | | | 107.2.1; NEC 215.5 (THE KEY PLAN SHOWS THE METER STACKS | | | IN 3 LOCATIONS, SO TAP RULES DICTATE THAT THESE TAPS | | | MUST TERMINATE IN A SINGLE BREAKER OR SET OF FUSES. | | | PROVIDE CORRECTION. NEC 240.21(B)(5) ) | | | 5. CORRECTED. | | | 6. GROUNDING ELECTRODE CONDUCTOR SPECIFIED IS NOT SIZED | | | PROPERLY. PROVIDE CORRECTION. NEC 250.66 (4TH REVIEW, | | | SIZE NOT CORRECT.) | | | 7. SHOW LOCATION OF SERVICE ON PLAN. FBC 107.2.1 (NOT | | | CORRECTED.)(4TH REVIEW. KEY PLAN IS NOT TO SCALE AND | | | DIFFICULT TO SEE, PROVIDE AS PREVIOUSLY REQUESTED. | | | THERE WERE TWO E-2 SHEETS PROVIDED AND THE SECOND ONE | | | SHOWS A FULL LAYOUT OF BUILDING, BUT NEED TO REMANE THE | | | SHEET SO THERE ARE NOT DUPLICATES.) | | | 8. SHOW LOCATION OF NEW CU UNITS ON PLAN. PROVIDE GFCI | | | PROTECTED OUTLET FOR SERVICING OF A/C EQUIPMENT PER | | | CODE. NEC 210.63; FBC 107.2.1 (4TH REVIEW, NOT PROVIDED | | | SATISFACTORILY. NEED FULL PLAN SHOWING BUILDING AND THE | | | LOCATIONS OF UNITS. THERE WERE TWO E-2 SHEETS PROVIDED | | | AND THE SECOND ONE SHOWS A FULL LAYOUT OF BUILDING, BUT | | | DOES NOT SHOW LOCATIONS OF UNITS. NEED TO REMANE THE | | | SHEET SO THERE ARE NOT DUPLICATES.) | | | 9. CORRECTED. | | | 10. CORRECTED. | | | 11. CORRECTED. | | | 12. ADDITIONAL PLAN REVIEW FEE ADDED PER PREVIOUS | | | COMMENT. PLAN REVIEW FEES NEED TO BE PAID BEFORE | | | RESUBMITTAL OF PLANS. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2018-02-28 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-02-28 |
Time |
08:12 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-02-28 |
Time |
08:12 |
Sent To |
|
|
| Notes |
| 2018-02-28 08:12:06 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY HAVE BEEN NOTED AS CORRECTED. ITEMS | | | REMAINING HAVE FURTHER COMMENTS IN PARENTHESES. | | | | | | 1. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | | LOADS. THE LOAD CALCULATION PROVIDED USED A DEMAND | | | FACTOR FOR EACH UNIT, AND THEN USED THOSE NUMBERS TO | | | APPLY A SECOND DEMAND FACTOR FOR MULTI-FAMILY | | | DWELLINGS, WHICH IS NOT PERMITTED. ADDITIONALLY, I DO | | | NOT SEE ANY HOUSE PANEL LOADS ADDED. WILL THERE BE ANY | | | HOUSE LOADS INCLUDING LIGHTING OF EXTERIOR? FBC | | | 107.2.1; NEC 220.40 (NEC 220.83 CANNOT BE USED FOR THIS | | | PROJECT, IT IS ONLY FOR A ONE FAMILY DWELLING WHERE | | | LOAD IS TO BE ADDED. PROVIDE ACCURATE LOAD CALCULATION | | | AS REQUESTED.) | | | 2. CORRECTED. | | | 3. BASED ON THE LOADS PROVIDED, THE PROPOSED SERVICE IS | | | NOT ADEQUATE FOR THE LOADS. PROVIDE CORRECTION. NEC | | | 215.2, 215.3, 220.40 (BASED ON MY CALCULATION FROM THE | | | LOADS PROVIDED ON PLAN, THE MINIMUM SERVICE WOULD NEED | | | TO HAVE A CAPACITY OF AT LEAST 886 AMPS. SERVICE | | | DESIGNED IS NOT ADEQUATE FOR THE LOADS SPECIFIED.) | | | 4. PROVIDE ACCURATE RISER DIAGRAM. BASED ON SITE VISIT, | | | THE EXISTING MAIN IS 400 AMPS, NOT 800. IS THE PROPOSED | | | SERVICE JUST A DISCONNECT, OR DOES IT HAVE BREAKERS | | | THAT FEED THE METER STACKS? HOW ARE THE METER STACKS | | | FED? IS THERE A GUTTER WITH TAPS? WHAT IS THE PHYSICAL | | | LOCATION OF ALL THE METERS? RISER PROVIDED DOES NOT | | | HAVE ENOUGH INFORMATION. PROVIDE CLARIFICATION. FBC | | | 107.2.1; NEC 215.5 (MANY OF THE QUESTIONS IN THIS | | | PARAGRAPH ARE NOT ANSWERED WITH YOUR RESPONSE TO ?SEE | | | E-1?. PROVIDE DETAILS AS REQUESTED.) | | | 5. IF METER BANKS ARE ALL TAPPED FROM 800 AMP MAIN, | | | PROVIDE LOAD CALCULATION FOR EACH SET OF FEEDERS TO | | | CONFIRM THE FEEDER IS SIZED ADEQUATELY. NEC 215.2, | | | 220.40 (LOAD CALCULATION TO EACH OF THE 8 METER BANKS | | | IS NOT CORRECT AND WIRE IS NOT SIZED PROPERLY.) | | | 6. GROUNDING ELECTRODE CONDUCTOR SPECIFIED IS NOT SIZED | | | PROPERLY. PROVIDE CORRECTION. NEC 250.66 | | | 7. SHOW LOCATION OF SERVICE ON PLAN. FBC 107.2.1 (NOT | | | CORRECTED.) | | | 8. SHOW LOCATION OF NEW CU UNITS ON PLAN. PROVIDE GFCI | | | PROTECTED OUTLET FOR SERVICING OF A/C EQUIPMENT PER | | | CODE. NEC 210.63; FBC 107.2.1 (NOT PROVIDED) | | | 9. PROVIDE COPY OF SIGNED CONTRACT FOR ELECTRICAL WORK, | | | SHOWING TOTAL VALUE OF ALL WORK INCLUDING MATERIALS AND | | | LABOR. THE ESTIMATE PROVIDED IS TOO LOW AND DOES NOT | | | REFLECT THE AMOUNT OF WORK REQUIRED FOR THIS PROJECT. | | | FBC 109.3 (CONTRACT PROVIDED DOES NOT INCLUDE WORK TO | | | SERVICE. PROVIDE CORRECTION) | | | 10. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | | SERVICE (SHOW ON PLAN). THIS IS NOT A WIRE, BUT AN | | | ACTUAL TERMINATION POINT. SEE CODE. NEC 250.94 (NOT | | | SHOWN ON PLAN) | | | | | | NEW COMMENT: | | | | | | 11. PROVIDE SPECS FOR MECHANICAL EQUIPMENT TO CONFIRM | | | STATED DEMAND IS ACCURATE. NEC 110.3, 220; FBC 107.2.1 | | | 12. PLEASE BE ADVISED THAT SOME OF THE COMMENTS HAVE | | | NOT BEEN ADDRESSED FOR TWO REVIEWS. IF UPON THE THIRD | | | REVIEW, IF IT IS NECESSARY TO REJECT THE SUBMITTED PLAN | | | A THIRD TIME FOR THE SAME REASONS, AN ADDITIONAL PLAN | | | REVIEW IS REQUIRED. FLORIDA STATUTES STATE: WITH | | | RESPECT TO EVALUATION OF DESIGN PROFESSIONALS? | | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. FS 553.80(2)(B) | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-01-04 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-01-04 |
Time |
12:40 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-01-04 |
Time |
12:40 |
Sent To |
|
|
| Notes |
| 2018-01-04 12:40:40 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | | LOADS. THE LOAD CALCULATION PROVIDED USED A DEMAND | | | FACTOR FOR EACH UNIT, AND THEN USED THOSE NUMBERS TO | | | APPLY A SECOND DEMAND FACTOR FOR MULTI-FAMILY | | | DWELLINGS, WHICH IS NOT PERMITTED. ADDITIONALLY, I DO | | | NOT SEE ANY HOUSE PANEL LOADS ADDED. WILL THERE BE ANY | | | HOUSE LOADS INCLUDING LIGHTING OF EXTERIOR? FBC | | | 107.2.1; NEC 220.40 | | | 2. PER CODE, FOR DWELLING UNITS, ATTACHED GARAGES, AND | | | DETACHED GARAGES WITH ELECTRIC POWER, AT LEAST ONE WALL | | | SWITCH-CONTROLLED LIGHTING OUTLET SHALL BE INSTALLED ON | | | THE EXTERIOR SIDE OF OUTDOOR ENTRANCES/EXITS WITH GRADE | | | LEVEL ACCESS. PROVIDE CORRECTION. NEC 210.70(A)(2)(B) | | | 3. BASED ON THE LOADS PROVIDED, THE PROPOSED SERVICE IS | | | NOT ADEQUATE FOR THE LOADS. PROVIDE CORRECTION. NEC | | | 215.2, 215.3, 220.40 | | | 4. PROVIDE ACCURATE RISER DIAGRAM. BASED ON SITE VISIT, | | | THE EXISTING MAIN IS 400 AMPS, NOT 800. IS THE PROPOSED | | | SERVICE JUST A DISCONNECT, OR DOES IT HAVE BREAKERS | | | THAT FEED THE METER STACKS? HOW ARE THE METER STACKS | | | FED? IS THERE A GUTTER WITH TAPS? WHAT IS THE PHYSICAL | | | LOCATION OF ALL THE METERS? RISER PROVIDED DOES NOT | | | HAVE ENOUGH INFORMATION. PROVIDE CLARIFICATION. FBC | | | 107.2.1; NEC 215.5 | | | 5. IF METER BANKS ARE ALL TAPPED FROM 800 AMP MAIN, | | | PROVIDE LOAD CALCULATION FOR EACH SET OF FEEDERS TO | | | CONFIRM THE FEEDER IS SIZED ADEQUATELY. NEC 215.2, | | | 220.40 | | | 6. GROUNDING ELECTRODE CONDUCTOR SPECIFIED IS NOT SIZED | | | PROPERLY. PROVIDE CORRECTION. NEC 250.66 | | | 7. SHOW LOCATION OF SERVICE ON PLAN. FBC 107.2.1 | | | 8. SHOW LOCATION OF NEW CU UNITS ON PLAN. PROVIDE GFCI | | | PROTECTED OUTLET FOR SERVICING OF A/C EQUIPMENT PER | | | CODE. NEC 210.63; FBC 107.2.1 | | | 9. PROVIDE COPY OF SIGNED CONTRACT FOR ELECTRICAL WORK, | | | SHOWING TOTAL VALUE OF ALL WORK INCLUDING MATERIALS AND | | | LABOR. THE ESTIMATE PROVIDED IS TOO LOW AND DOES NOT | | | REFLECT THE AMOUNT OF WORK REQUIRED FOR THIS PROJECT. | | | FBC 109.3 | | | 10. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | | SERVICE (SHOW ON PLAN). THIS IS NOT A WIRE, BUT AN | | | ACTUAL TERMINATION POINT. SEE CODE. NEC 250.94 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-11-20 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-11-20 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-11-20 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2017-11-20 15:52:31 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED AND | | | SEALED BY A LICENSED DESIGN PROFESSIONAL OR THE | | | ELECTRICAL CONTRACTOR QUALIFIER. FS 471.003(2)(H); | | | 471.025; FBC 107.2.1, 107.3.5 | | | 2. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4 | | | 3. SHOW ON FLOOR PLAN ALL EXISTING SMOKE ALARMS. IF | | | NONE ARE EXISTING, OR NOT TO CODE, SHOW AS NEW | | | INSTALLATION. FBC 107.2.1 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2018-12-10 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-12-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-12-10 |
Time |
15:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2018-09-14 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-09-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-09-13 |
Time |
15:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2018-04-26 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-04-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-04-25 |
Time |
15:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-12-27 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-12-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-12-27 |
Time |
10:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2017-11-13 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-11-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-11-09 |
Time |
12:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
6 |
Status |
P |
Date |
2019-01-03 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-01-03 |
Time |
07:54 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-01-03 |
Time |
07:42 |
Sent To |
|
|
| Notes |
| 2019-01-03 07:54:44 | GAS COMMENTS: APPROVED | | | | | | PROVISO | | | 1. PERMIT IS TO BE FOR GAS DEMO ONLY | | | 2. ALL WORK PER CITY CODES SUBJECT TO FIELD INSPECTOR'S | | | APPROVAL | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
5 |
Status |
P |
Date |
2018-09-27 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2018-09-27 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-09-27 |
Time |
09:00 |
Sent To |
|
|
| Notes |
| 2018-09-27 09:00:19 | 5TH REVIEW: | | | PERMIT 17110126 | | | GAS COMMENTS: APPROVED | | | | | | PROVISO | | | GAS PERMIT IS REQUIRED; PERMIT IS TO BE FOR GAS DEMO | | | ONLY | | | | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2018-05-02 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-05-02 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-05-02 |
Time |
14:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2018-03-03 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-03-03 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-03-03 |
Time |
09:02 |
Sent To |
|
|
| Notes |
| 2018-03-03 09:04:50 | 3RD REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: PREVIOUS COMMENT NOT COMPLIED 2ND | | | REQUEST | | | | | | 1. PROVIDE PLAN SHOWING HOW AND WHERE GAS WILL BE | | | DEMOED AND CAPPED OFF. PER WPB AMEND TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2018-01-18 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-01-18 |
Time |
17:47 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-01-18 |
Time |
17:47 |
Sent To |
|
|
| Notes |
| 2018-01-18 17:50:00 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. PROVIDE PLAN SHOWING HOW AND WHERE GAS WILL BE | | | DEMOED AND CAPPED OFF. PER WPB AMEND TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2017-11-22 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-11-22 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-11-22 |
Time |
12:33 |
Sent To |
|
|
| Notes |
| 2017-11-22 13:00:33 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. UNDER THE SCOPE OF WORK IT LIST REPLACE A TANK WATER | | | HEATER SHT. A-2 SHOWS A TANK WATER HEATER IN THE A UNIT | | | AND A TANKLESS IN THE B UNITS PLEASE CLARIFY WHICH TYPE | | | OF WATER HEATERS ARE BEING USED HOW MANY ARE BEING | | | CHANGED AND IN WHICH APARTMENTS. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | 2. PROVIDE EXISTING GAS PIPING DIAGRAM SHOWING TYPE OF | | | PIPE, SIZE, BTU LOAD, PRESSURE AND APPROXIMATE LENGTH | | | OF PIPING. PER FBC FG 402.4.1, 402.4.2. AND WPB AMEND | | | TO FBC 107.2.1 | | | | | | 3. PLEASE PROVIDE MANUFACTURE SPECIFICATIONS AND | | | INSTALLATION GUIDES FOR THE WATER HEATERS. PER FBC FG | | | 402.2 AND WPB AMEND TO FBC 107.2.1 | | | | | | 4. WILL THE EXISTING VENTING BE USED IF SO IT SHALL BE | | | INSPECTED PLEASE PLEASE NOTE ON PLAN STATING THIS. PER | | | WPB AMEND TO FBC 107.2.1 | | | | | | 5. WILL THE NEW WATER HEATERS BE EXACT CHANGE OUT FROM | | | EXISTING PLACE NOTE ON PLAN. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | 6. A DROPTEST AFFIDAVIT ON THE COMPLETE GAS SYSTEM WILL | | | BE REQUIRED AT FINAL INSPECTION PLEASE PLACE NOTE ON | | | PLAN. PER WPB AMEND TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2019-02-14 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-02-14 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-02-14 |
Time |
13:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2019-01-04 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2019-01-04 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-12-05 |
Time |
09:24 |
Sent To |
|
|
| Notes |
| 2019-01-03 08:10:32 | TO S. HILL DESK | | 2019-01-03 07:34:25 | 1/2 TO JESMITH DESK / S.HILL | | | | | | | | 2018-12-10 11:39:25 | B11 | | 2018-12-07 09:25:37 | LIBRARY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2018-12-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-12-05 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-10-24 |
Time |
16:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2018-09-27 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2018-09-27 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-08-29 |
Time |
14:17 |
Sent To |
|
|
| Notes |
| 2018-09-25 18:09:01 | ON JERRY SMITH'S DESK | | | | | 2018-09-12 14:17:43 | B20 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2018-08-31 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2018-08-31 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-08-29 |
Time |
10:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2018-05-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-05-13 |
Time |
10:15 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-04-20 |
Time |
14:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-03-03 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-03-03 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-02-12 |
Time |
14:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-01-18 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-01-18 |
Time |
18:03 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-12-21 |
Time |
09:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-11-22 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-11-22 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-11-03 |
Time |
10:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2018-12-20 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-12-20 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-12-20 |
Time |
13:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2018-11-08 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-11-08 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-11-08 |
Time |
13:10 |
Sent To |
|
|
| Notes |
| 2018-11-08 13:32:15 | MECHANICAL PLAN REVIEW FAIL | | | | | | 1) THE REQUESTED CORRECTED ENERGY COMPLIANCE FORMS WERE | | | NOT CORRECTED AND RESUBMITTED. | | | | | | 2) THE AC CALCULATIONS ARE BASING DESIGN CONDITIONS ON | | | FT. LAUDERDALE, AND ARE INDICATING TRANE SYSTEMS TO BE | | | INSTALLED, HOWEVER RHEEM SYSTEMS ARE SHOWN ON THE PLAN. | | | | | | | | | CHRIS MONTELLO | | | 561-805-6733 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2018-09-18 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-09-18 |
Time |
13:40 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-09-18 |
Time |
13:40 |
Sent To |
|
|
| Notes |
| 2018-09-18 13:52:12 | 3RD REVIEW FBC-2014 MECHANICAL, ENERGY CONSERVATION, | | | EXISTING BUILDING CODES | | | PERMIT #17110126 | | | 9/18/18 | | | | | | 1) THE REVISED PLAN IS STILL INDICATING A 2" CLEARANCE | | | WILL BE PROVIDED AROUND THE AIR HANDLER, HOWEVER 4" IS | | | REQUIRED. | | | | | | 2) THE REQUESTED CORRECTED ENERGY COMPLIANCE FORMS WERE | | | NOT CORRECTED AND RESUBMITTED. | | | | | | 3) THE AC CALCULATIONS ARE BASING DESIGN CONDITIONS ON | | | FT. LAUDERDALE, AND ARE INDICATING TRANE SYSTEMS TO BE | | | INSTALLED, HOWEVER RHEEM SYSTEMS ARE SHOWN ON THE PLAN. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2018-04-27 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-04-27 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-04-27 |
Time |
16:48 |
Sent To |
|
|
| Notes |
| 2018-04-27 17:05:03 | 2ND REVIEW FBC-2014 MECHANICAL, ENERGY CONSERVATION, | | | EXISTING BUILDING CODES | | | PERMIT #17110126 | | | 4/27/18 | | | | | | PLAN REVIEW RESULTS | | | | | | 1) THE ENERGY COMPLIANCE FORMS MUST BE THE R405-2014 | | | VERSIONS, AND MUST BE SIGNED BY THE PERSON WHO PREPARED | | | THE FORMS AND BY THE OWNER- SEE SECTION R103.1.1.2 | | | FBC-14 ENERGY CONSERVATION. | | | | | | 2) M-1: A 4" CLEARANCE IS REQUIRED AROUND THE | | | AIRHANDLER- PLEASE CORRECT THE NOTE SPECIFYING 2"-, AND | | | VERIFY THE CONDENSATE PIPING IN THE AC CLOSET IS | | | NON-COMBUSTIBLE- SECTIONS 602.2 AND 603.1.1. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2018-02-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-02-22 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-02-22 |
Time |
16:08 |
Sent To |
|
|
| Notes |
| 2018-02-22 17:01:59 | 2ND REVIEW FBC-2014 MECHANICAL, ENERGY CONSERVATION, | | | EXISTING BUILDING CODES | | | PERMIT #17110126 | | | 2/22/18 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) ENERGY COMPLIANCE FORMS AND AND AC CALCULATIONS HAVE | | | BEEN SUBMIITED FOR FOUR OF THE TWENTY APARTMENTS. THE | | | UNITS ARE IDENTIFIED AS MODELS 1 & 2 LOW AND HIGH | | | FLOOR, HOWEVER THE REPORT IS NOT INDICATING THAT THESE | | | ARE "WORST CASE" CALCULATIONS, THEREFORE CALCULATIONS | | | SHALL BE SUBMITTED FOR ALL OF THE APARTMENTS. IF THE | | | CALCULATIONS ARE TO BE PERFORMED AS "WORST CASE" THEN | | | THE | | | | | | REPORTS MUST BE LABELED AS SUCH, AND ALSO DEMONSTRATE | | | THAT THE MODELS MEET THE PERFORMANCE REQUIREMENTS IN | | | EACH OF THE FOUR CARDINAL (NORTH, SOUTH, EAST, AND | | | WEST) ORIENTATIONS- SEE SECTION R405.4.2 FBC-14 ENERGY | | | CONSERVATION. PLEASE NOTE THE APARTMENT MODEL | | | IDENTIFICATIONS ( #1 & 2) IN THE CALCS DO NOT MATCH THE | | | (TYPE A & B) IDENTIFICATIONS ON THE PLANS. | | | | | | 2) 2ND REQUEST FOR MINIMUM VENTILATION FOR EACH | | | APARTMENT USING EITHER MECHANICAL OR NATURAL MEANS- | | | SECTION 401.2. THE RESUBMITTED PLAN INDICATES NATURAL | | | FOR APARTMENT TYPE B BUT DOES NOT SHOW THE UNIT | | | COMPLIES WITH 402.2- MINIMUM OPERABLE AREA TO THE | | | OUTDOORS SHALL BE 4% OF THE FLOOR AREA. CONCERNING TYPE | | | A THERE IS NO VENTILATION INDICATED OR CALCULATIONS | | | PROVIDED. | | | | | | 3) INDICATE THE DIEMNSIONS OF THE RETURN GRILL IN THE | | | KITCHEN/LIVING ROOM OF THE TYPE B MODEL. | | | | | | 4) PROVIDE A COMPLETE AC EQUIPMENT SCHEDULE ON THE PLAN | | | FOR THE MODEL A SYSTEM- COOLING AND HEATING CAPACITY, | | | SUPPLY CFMS, AND EFFICIENCY RATING. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-01-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-01-02 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-01-02 |
Time |
12:04 |
Sent To |
|
|
| Notes |
| 2018-01-02 14:13:30 | 1ST REVIEW FBC-2014 MECHANICAL, ENERGY CONSERVATION, | | | EXISTING BUILDING CODES | | | PERMIT #17110126 | | | 1/2/2018 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE COOLING AND HEATING CALCULATIONS FOR THE NEW | | | AC SYSTEMS- SEE SECTIONS C403.2.1 AND C407.5.2.3 ENERGY | | | CONSERVATION. | | | | | | 2) REFER TO SECTION C101.4.5 FBC-14 ENERGY CONSERVATION | | | AND SUBMIT AN ENERGY COMPLIANCE REPORT FOR THE | | | BUILDING. | | | | | | 3) SHEET M-1: NATURAL OR MECHANICAL VENTILATION IS | | | REQUIRED FOR EACH APARTMENT PER SECTION 401.2. PLEASE | | | INDICATE WHICH METHOD WILL BE USED AND PROVIDED | | | CALCULATIONS AND DETAILS. | | | | | | 4) M-1: NO SUPPLY AND RETURN AIR IS SHOWN FOR THETYPE A | | | APARTMENT BEDROOMS 1 & 2, AND NO SUPPLY IS PROVIDED TO | | | THE TYPE B KITCHEN/LIVING/DINING ROOMS- SEE SECTION | | | 601.5 FBC-14 MECHANICAL AND CORRECT. | | | | | | 5) M-1: VERIFY THE AC CLOSET DOORS ARE NON-COMBUSTIBLE | | | IN ACCORDANCE WITH SECTION C403.2.7.2 FBC-14 ENERGY | | | CONSERVATION CODE, AND SECTION 602.2.1 FBC-14 | | | MECHANICAL. | | | | | | 6) M-1: AN INCORRECT WIND SPEED OF 160 MPH IS NOTED. | | | PLEASE NOTE THAT THE WIND SPEED IN WEST PALM BEACH IS | | | 170 MPH. CORRECT THE NOTE AND PROVIDE COMPLETE WIND | | | LOAD DESIGN CRITERIA INCLUDING THE IMPORTANCE FACTOR, | | | EXPOSURE CATEGORY, AND THE LATERAL AND UPLIFT | | | PRESSURES. | | | | | | 7) PROVIDE A MECHANICAL SITE PLAN THAT SHOWS THE | | | LOCATIONS OF ALL THE CONDENSERS AND THE REFRIGERANT | | | PIPING RUNS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2019-01-03 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-01-03 |
Time |
07:58 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-01-03 |
Time |
07:50 |
Sent To |
|
|
| Notes |
| 2019-01-03 07:58:33 | PLUMBING COMMENTS: APPROVED | | | | | | PLUMBING PROVISO | | | 1. ALL WORK PER CITY CODES SUBJECT TO FIELD INSPECTOR'S | | | APPROVAL | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2018-09-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-25 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-09-25 |
Time |
17:58 |
Sent To |
|
|
| Notes |
| 2018-09-25 18:08:46 | ON JERRY SMITH'S DESK | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2018-05-02 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-05-02 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-05-02 |
Time |
08:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2018-03-03 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-03-03 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-03-03 |
Time |
09:05 |
Sent To |
|
|
| Notes |
| 2018-03-03 09:07:05 | PLUMBING WILL BE APPROVED WHEN THE GAS IS APPROVED. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-01-18 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-01-18 |
Time |
17:45 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-01-18 |
Time |
17:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-11-22 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-11-22 |
Time |
12:08 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-11-21 |
Time |
17:29 |
Sent To |
|
|
| Notes |
| 2017-11-22 12:33:31 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. THE LEGAL DESCRIPTION ON THE PLAN DOES NOT MATCH THE | | | LEGAL DESCRIPTION ON THE PALM BEACH COUNTY PROPERTY | | | APPRAISER PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 2. UNDER THE LEGAL DESCRIPTION IT LIST UNIT #602 IS | | | THIS THE ONLY APARTMENT THAT IS BEING REMODELED PLEASE | | | CLEARLY INDICATE ON THE PLAN WHICH APARTMENTS ARE BEING | | | REMODELED. PER WPB AMEND TO FBC 107.2.1 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
|