Plan Review Details - Permit 17110125
Plan Review Stops For Permit 17110125
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-11-22 Cont ID  
Sent By shill Date 2017-11-22 Time 12:17 Rev Time 0.00
Received By shill Date 2017-11-22 Time 12:17 Sent To  
Notes
2017-11-22 13:13:55****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 TENT PERMIT REQUIRED
 BUILDING REVIEW REQUIRED FOR TENT - SEE FBC 2014
 BUILDING 3103; PLANS TO SHOW COMPLIANCE WITH ALL
 REQUIREMENTS.
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2017-11-28 Cont ID  
Sent By wjolin Date 2017-11-28 Time 11:14 Rev Time 0.00
Received By wjolin Date 2017-11-28 Time 11:09 Sent To  
Notes
2017-11-28 11:13:224610 BROADWAY
 PERMIT #17110125
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 PROVIDE NONCOMBUSTIBLE FLAME CERTIFICATE FOR THE TENT
 MATERIAL.
  
 EMERGENCY LIGHTING AND ILLUMINATED EXIT SIGNS ARE
 REQUIRED FOR TENTS EXCEEDING 1,200 SQUARE FEET.
  
 PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS
 SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE
 TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL
 DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET.
 PROVIDE TYPE K EXTINGUISHERS WHEN COOKING WITH GREASE
 OR WHEN PRODUCING SMOKE OR GREASE-LADEN VAPORS.
  
 TENTS SHALL BE LOCATED AT LEAST 10 FEET AWAY FROM
 BUILDING STRUCTURES.
  
 POST WEATHERPROOF NO SMOKING SIGNS IN CONSPICUOUS
 LOCATIONS.
  
 PROVIDE A FLOOR PLAN FOR THE TENT INDICATING EXITS,
 EXIT SIGNS, EMERGENCY LIGHTING, COOKING APPLIANCES,
 GENERATORS, SEATING, DANCE FLOOR, ETC.
  
 A THOROUGH AND COMPLETE PLAN REVIEW CANNOT BE COMPLETED
 AT THIS TIME DUE TO LACK OF INFORMATION SUBMITTED ON
 THE PLANS. ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED DURING PLAN RESUBMISSION.
  
 WESLEY JOLIN
 ASSISTANT FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-01-05 Cont ID  
Sent By shill Date 2018-01-05 Time 06:59 Rev Time 0.00
Received By shill Date 2017-11-22 Time 10:24 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2017-12-28 Cont ID  
Sent By ajones Date 2017-12-28 Time 16:50 Rev Time 0.00
Received By ajones Date 2017-12-28 Time 16:50 Sent To  
Notes
***NONE***