Plan Review Details - Permit 17110090
Plan Review Stops For Permit 17110090
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2018-07-10 Cont ID  
Sent By rgathrig Date 2018-07-10 Time 12:13 Rev Time 0.00
Received By rgathrig Date   Time   Sent To  
Notes
2018-07-10 12:13:28PROVISO FOR SOUND TRANSMISSION TEST VERIFICATION WAS
 SUBMITTED/APPROVED UNDER 17110020 (REG)

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-01-18 Cont ID  
Sent By aclange Date 2018-01-18 Time 11:14 Rev Time 0.00
Received By aclange Date 2018-01-18 Time 10:40 Sent To  
Notes
2018-01-18 11:15:37PREVIOUS PROVISIOS AND DEFERRED SUMITTALS OUTSTANDING.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2017-12-07 Cont ID  
Sent By jwitmer Date 2017-12-07 Time 07:45 Rev Time  
Received By jwitmer Date 2017-12-07 Time 07:15 Sent To  
Notes
2017-12-07 07:36:462014 FBC- BUILDING PLAN REVIEW
 W. P. B. REVISION: 17110900
 W. P. B. PERMIT: 15111020
 ADD: 1100 S. FLAGLER DR. SUITE: GUEST UNIT 9
 CONT: SUFFOLK
 TEL: 561-827-3678
 E-MAIL: [email protected]
  
 2010 FLORIDA BUILDING CODE W 2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 SUBJECT TO FAIR HOUSING!
  
 1ST REVIEW
 DATE:
 ACTION: BUILDING PROVISO
  
 1) SUFFOLK CONSTRUCTION TO CONDUCT SITE TESTING FOR
 COMPLIANCE WITH THE 2010 FBC-B SECTIONS:
 FBC-B 2010 1207.3 STRUCTURE-BORNE SOUND.
 FBC-B 2010 1207.2 AIR-BORNE SOUND.
 FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2.
 THE SOUND TESTS WILL BE CONDUCTED ON A 10 INCH CONCRETE
 SLAB UNDER THE MAIN PERMIT (15111020) AND SUBMITTED AS
 SOON AS RESULTS ARE PRINTED AND REVIEWED BY THE
 DESIGNER OF RECORD.
  
 NOTE: SITE TESTING FOR FLOOR INSULATION WILL REQUIRE
 THE APPLICANT TO REQUEST (IN WRITING) UNDER THE 2010 W.
 P. B. ADMINISTRATIVE CODE SECTION 104.11 ALTERNATE
 MATERIALS, DESIGN AND METHODS OF CONSTRUCTION FOR THE
 SOUND UNDERLAYMENT. THE LETTER SHOULD BE MADE OUT TO
 THE BUILDING OFFICIAL ROBERT BROWN.
  
 SHEET: FINISHES. UNIT:
 FLOOR FINISHES. BLDG TYPE: TYPE I/ TYPE II FLOOR
 INSULATION (FBC-B 2010)
 FOR TILE, STONE, MARBLE, VINYL AND WOOD FLOORING ALL
 NEED TO HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR
 ASSEMBLIES TO THE FOLLOWING STANDARDS AND MEET THE
 QUALIFICATIONS LISTED UNDER EACH OF THE STANDARDS FOR A
 10 INCH CONCRETE FLOOR ASSEMBLY AS PER PLAN OR PROVIDE
 ONSITE TESTING TO THE LISTED BELOW ASTM STANDARDS:
 PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH:
  
 1A) FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 1B) FBC-B 2014 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 1C) FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 2) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2017-12-07 Cont ID  
Sent By jleahy Date 2017-12-07 Time 16:04 Rev Time 0.00
Received By jleahy Date 2017-12-07 Time 16:04 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2017-11-27 Cont ID  
Sent By pleduc Date 2017-11-27 Time   Rev Time 0.00
Received By pleduc Date 2017-11-27 Time 14:34 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-01-31 Cont ID  
Sent By cpuell Date 2018-01-31 Time 16:44 Rev Time 0.00
Received By cpuell Date 2018-01-11 Time 07:22 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-12-13 Cont ID  
Sent By cpuell Date 2017-12-13 Time 13:50 Rev Time 0.00
Received By cpuell Date 2017-11-22 Time 09:05 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2017-11-30 Cont ID  
Sent By ccole Date 2017-11-30 Time 11:46 Rev Time 0.00
Received By ccole Date 2017-11-30 Time 11:46 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2018-01-31 Cont ID  
Sent By jwitmer Date 2018-01-31 Time 16:06 Rev Time 0.00
Received By gjohnson Date 2018-01-31 Time 16:06 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-12-13 Cont ID  
Sent By gjohnson Date 2017-12-13 Time 11:51 Rev Time  
Received By jwitmer Date 2017-12-13 Time 08:18 Sent To  
Notes
2017-12-13 11:51:452014 FBC- PLUMBING PLAN REVIEW
 W. P. B. REVISION: 17110090
 W. P. B. PERMIT: 15111020
 ADD: 1100 S. FLAGLER DR. GUEST SUITE NUMBER 9
 CONT: SUFFOLK
 TEL: 561-832-1616 / JASON KRAUS
 E-MAIL: [email protected]
  
 2010 FLORIDA BUILDING CODE W 2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 1ST REVIEW
 DATE: WED. DEC. 13/ 2017
 ACTION: DENIED
  
 1) PLEASE REVIEW SHEETS210.09-A6.68-GS9 AND
 540.09-P2-90-GS9. THE TUB WAS REMOVED UNDER THIS
 REVISION AND A PROPOSED SHOWER TO BE INSTALLED IN ITS
 PLACE. THE SHOWER STALL HAS A DIMENSION OF 3 FEET 2 7/8
 INCHES FROM SIDE TO SIDE. THERE IS NO DIMENSION FROM
 FRONT TO BACK. IT ALSO LOOKS LIKE THIS SHOWER HAS A
 CURB; THIS DIMENSION IS ALSO NOT GIVEN. THE PLANS DO
 NOT INDICATE ON EITHER THE ARCHITECTURAL NOR PLUMBING
 SHEET IF THIS BATHROOM WAS DESIGNED TO SPECIFICATION A
 OR B. FAIR HOUSING GUIDELINES? IT WOULD APPEAR SINCE
 THIS GUEST SUITE HAS ONLY ONE BATHROOM SPECIFICATION B
 HAS TO BE USED. WHEN SPECIFICATION B IS USED
 AND ONLY ONE OF EACH TYPE OF FIXTURE IS IN THE BATHROOM
 THEN THEY MUST MEET THE REQUIREMENTS, THE SHOWER SHOULD
 NOT HAVE A LOW CURB PLEASE PROVIDE DETAILS.
  
 IN SPECIFICATION B BATHROOMS, HOWEVER, IN ADDITION TO
 THE REINFORCING REQUIRED FOR GRAB BARS, THE SHOWER
 STALL MUST HAVE REINFORCING TO ALLOW FOR LATER
 INSTALLATION OF AN OPTIONAL WALL MOUNTED SEAT IN THE
 SHOWER.
  
 2) PLEASE REVIEW SHEET 103.09-A2.90-GS9 THE 30X 48 INCH
 CLEAR FLOOR SPACE IS SHOWN ON THIS SHEET BUT THE PLAN
 DOES NOT SHOW THE CONTROL VALVES PARALLEL TO THE CLEAR
 FLOOR SPACE. SHEET 540.09-P2-90-GS9 SHOWS THE HOT AND
 COLD WATERLINES ABOVE THE CEILING AND DROPPING DOWN
 INTO THE WALL CLOSET TO THE WATER CLOSET BUT NO CONTROL
 VALVES ARE INDICATED ON THIS PLAN. 107.2.1.3 ADDITIONAL
 INFORMATION IS REQUIRED.
  
 3) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2018-01-31 Cont ID  
Sent By cpuell Date 2018-01-31 Time 16:44 Rev Time 0.00
Received By cpuell Date 2018-01-31 Time 16:44 Sent To  
Notes
2017-12-13 11:54:0412/13/17. ARCHITECTURAL AND PLUMBING SHEETS REVIEWED
 FOR DIGITAL SIGNATURES. JW