Plan Review Details - Permit 17110077
| Plan Review Stops For Permit 17110077 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-12-08 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-12-08 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-12-08 |
Time |
13:59 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-12-07 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-12-07 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-12-07 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2017-12-07 15:34:50 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PLAN IS REQUIRED TO BE SIGNED AND SEALED BY A DESIGN | | | PROFESSIONAL OR THE ELECTRICAL CONTRACTOR QUALIFIER. | | | THIS MUST BE A DIGITAL SIGNATURE FOR DIGITAL PLANS. FS | | | 471.003(2)(H); 471.025; FBC 107.2.1 | | | 2. PROVIDE DETAILS OF WIRING USED FOR SYSTEM, INDICATE | | | IF CABLING IS PLENUM RATED OR NOT. FBC 107.2.1; NEC | | | 800.113 | | | 3. PROVIDE LEGEND FOR DEVICES ON PLAN. FBC 107.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-12-08 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-12-08 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-12-08 |
Time |
13:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-12-07 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-12-07 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-11-14 |
Time |
13:51 |
Sent To |
|
|
| Notes |
|
|
|