| Plan Review Stops For Permit 17110040 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2017-12-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-12-19 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-12-19 |
Time |
09:21 |
Sent To |
|
|
| Notes |
| 2017-12-19 09:24:09 | ****PROVISOS**** | | | SUBJECT TO FIELD INSPECTOR'S DISCRETION, A REVISION MAY | | | BE REQUIRED | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. PROVIDE A DETAIL FOR THE PROPOSED NEW BENCH | | | INCLUDING BACK SUPPORT, FBC A 903. | | | | | | 2ND REVIEW, RESPONSE REFERS TO A 7 A202. THIS IS THE | | | SERVICE COUNTER DETAIL. | | | | | | 2. A202, FBC A 904, PROVIDE A DETAIL FOR THE SERVICE | | | COUNTER. CUSTOMER SIDE NOT TO EXCEED 2'6". | | | | | | 3. PER ARCHITECT, UNIT 109 (SHEET A205) HAS BEEN | | | REVIEWED UNDER A DIFFERENT PERMIT AND WAS SUBMITTED IN | | | ERROR. THIS SHEET HAS BEEN VOIDED. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2017-12-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-12-13 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-12-13 |
Time |
14:41 |
Sent To |
|
|
| Notes |
| 2017-12-13 14:49:31 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. REGARDING ADDRESSES, SOME PAGES STILL HAVE THE | | | NUMBERED UNIT DESIGNATIONS SO PLANS DO NOT CORRELATE | | | AFTER SOME SHEETS WERE REVISED (A205, A202). | | | | | | 2. SEE ELECTRICAL COMMENTS; IT APPEARS THAT TWO UNITS | | | ARE BEING REVISED. A SEPARATE PERMIT IS REQUIRED FOR | | | EACH PARCEL ID NUMBER. | | | | | | 2ND REVIEW, NOT ADDRESSED. ARCHITECT'S LETTER REFERS TO | | | MEP RESPONSE LETTER, MEP RESPONSE LETTER REFERS TO | | | ARCHITECT. | | | | | | 3. PROVIDE A DETAIL FOR THE PROPOSED NEW BENCH | | | INCLUDING BACK SUPPORT, FBC A 903. | | | | | | 2ND REVIEW, RESPONSE REFERS TO A 7 A202. THIS IS THE | | | SERVICE COUNTER DETAIL. | | | | | | 4. REAR EXIT DOORS, UNITS 106 AND 109, REVISE PLAN TO | | | SHOW 18" MANEUVERING CLEARANCE ON THE PULL SIDE, FBC A | | | FIGURE 404.2.4.1(A). | | | | | | 2ND REVIEW, ADDRESSED FOR UNIT CU2, NOT FOR UNIT 109. | | | | | | 5. OK | | | | | | 6. A202, FBC A 904, REVISE PLAN TO INCLUDE A DETAIL FOR | | | THE SERVICE COUNTER. | | | | | | 2ND REVIEW, DETAIL 7 A202 APPEARS TO HAVE A SERVICE | | | COUNTER AT 3'6", WORK AREA AT 2'6". THIS DOES NOT MEET | | | REQUIREMENT FOR SERVICE COUNTER. | | | | | | 2ND REVIEW NEW COMMENT: | | | | | | 7. IT APPEARS THAT OLD SHEETS WERE REMOVED FROM THE | | | SUBMITTAL. PLEASE NOTE THAT REMOVING OLD SHEETS DELAYS | | | PLAN REVIEW TIME. THE PLUMBING SHEETS PASSED, ARE NO | | | LONGER AVAILABLE FOR REFERENCE, SO A NEW REVIEW IS | | | REQUIRED. PLEASE RETAIN ALL PAGES IN THE SUBMITTAL | | | PACKAGE. OLD SHEETS SHOULD BE MARKED "VOID" OR "OLD | | | SHEETS". THEY SHOULD NOT BE BOUND WITH THE NEW PAGES, | | | BUT SUBMITTED AS A SEPARATE VOLUME. PLEASE CONTACT ME | | | WHEN RESUBMITTING IF YOU NEED ASSISTANCE. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-11-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-11-27 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-11-27 |
Time |
08:17 |
Sent To |
I |
|
| Notes |
| 2017-11-27 09:27:51 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. FBC 107, PLEASE RESOLVE ADDRESSING ISSUE. OUR SYSTEM | | | HAS DIFFERENT UNIT NUMBERS THAN ON THE PLAN AND | | | APPLICATION, WHICH ALS APPEAR TO DIFFER FROM PROPERTY | | | APPRAISER. PLEASE CONTACT [email protected] TO RESOLVE. | | | | | | 2. SEE ELECTRICAL COMMENTS; IT APPEARS THAT TWO UNITS | | | ARE BEING REVISED. A SEPARATE PERMIT IS REQUIRED FOR | | | EACH PARCEL ID NUMBER. | | | | | | 3. PROVIDE A DETAIL FOR THE PROPOSED NEW BENCH | | | INCLUDING BACK SUPPORT, FBC A 903. | | | | | | 4. REAR EXIT DOORS, UNITS 106 AND 109, REVISE PLAN TO | | | SHOW 18" MANEUVERING CLEARANCE ON THE PULL SIDE, FBC A | | | FIGURE 404.2.4.1(A). | | | | | | 5. A205, DOOR 109B, REVISE PLAN TO SHOW 18" MANEUVERING | | | CLEARANCE ON THE PULL SIDE, FBC A FIGURE 404.2.4.1(A). | | | | | | 6. A202, FBC A 904, REVISE PLAN TO INCLUDE A DETAIL FOR | | | THE SERVICE COUNTER. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-12-19 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-12-19 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-12-19 |
Time |
15:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-11-15 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-11-15 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-11-15 |
Time |
09:52 |
Sent To |
|
|
| Notes |
| 2017-11-15 09:51:57 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. SHEET E1.2, LIGHT IN STORAGE CLOSET SHOULD BE | | | CONTROLLED AUTOMATICALLY. FBC CE 405.2.2 | | | 2. SHEET E1.6 IS FOR UNIT 110, WHICH IS NOT INCLUDED | | | WITH THIS PERMIT NUMBER. ADDITIONALLY, SHEET ER.1 SHOWS | | | REVISIONS TO UNITS 107 AND 110, WHICH ARE NOT INCLUDED | | | WITH THIS PERMIT NUMBER. REMOVE ALL REVISIONS UNDER | | | SEPARATE PERMITS, WHICH SHOULD BE SUBMITTED SEPARATELY. | | | FBC 107.2.1, 107.4 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-12-13 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-12-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-12-12 |
Time |
12:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2017-11-07 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-11-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-11-06 |
Time |
14:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-12-27 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-12-27 |
Time |
13:26 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-12-07 |
Time |
15:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-11-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-11-27 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-11-01 |
Time |
14:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2017-11-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-11-27 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-11-27 |
Time |
09:49 |
Sent To |
|
|
| Notes |
| 2017-11-27 09:49:50 | CONFIRMED ON PLAN (LS.1 DATED 11/13/06) THAT MEZZANINES | | | WERE PERMITTED AS COMMERCIAL. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2017-12-18 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-12-18 |
Time |
07:44 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-12-15 |
Time |
17:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-11-09 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-11-09 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-11-09 |
Time |
12:53 |
Sent To |
|
|
| Notes |
| 2017-11-09 16:06:32 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #17110040 | | | 11/9/2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE A SEQUENCE OF OPERATION FOR EF-3- SEE | | | SECTION 501.4 | | | | | | 2) SHOW THE LOCATION OF THE NEW DRYER AND SUBMIT A CUT | | | SHEET. INDICATE GAS-FIRED OR ELECTRIC APPLIANCE, | | | PROVIDE DRYER EXHAUST DUCT DETAILS AND SHOW THE DUCT | | | RUN AND TERMINATION LOCATION. PLEASE NOTE THAT A GAS | | | PIPING ISOMETRIC DRAWING AND COMBUSTION AIR | | | CALCULATIONS ARE REQUIRED FOR A GAS DRYER. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2017-12-27 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-12-27 |
Time |
13:26 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-12-27 |
Time |
13:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2017-11-16 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-11-16 |
Time |
17:39 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-11-16 |
Time |
14:07 |
Sent To |
|
|
| Notes |
|
|