Plan Review Details - Permit 17110024
Plan Review Stops For Permit 17110024
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-11-17 Cont ID  
Sent By jwitmer Date 2017-11-17 Time 07:39 Rev Time 0.00
Received By jwitmer Date 2017-11-17 Time 07:20 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-11-03 Cont ID  
Sent By jwitmer Date 2017-11-03 Time 06:59 Rev Time  
Received By jwitmer Date 2017-11-03 Time 06:28 Sent To  
Notes
2017-11-03 06:59:182014 FBC- BUILDING PLAN REVIEW
 W. P. B. REVISION: 17110024
 W. P. B. PERMIT: 17101196
 ADD: 1380 6TH ST.
 CONT: PRISTINE ROOFING
 TEL: 561-632-3295
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: FRI. NOV. 3/ 2017
 ACTION: DENIED
  
 1) THE CONTRACTOR WILL NEED TO BRING IN A ROOF PLAN OF
 THE WHOLE ROOF AND WHERE THE WORK IS BEING COMPLETED
 AND SUBMIT THE STAMPED PRODUCT FOR THE SHINGLES(TO BE
 VOIDED) SINCE THIS IS NO LONGER IN THE SCOPE OF THE
 PROJECT. 107.4 AMENDED CONSTRUCTION DOCUMENTS. WORK
 SHALL BE INSTALLED IN ACCORDANCE WITH THE REVIEWED
 CONSTRUCTION DOCUMENTS, AND ANY CHANGES MADE DURING
 CONSTRUCTION THAT ARE NOT IN COMPLIANCE WITH
 THE REVIEWED CONSTRUCTION DOCUMENTS SHALL BE
 RESUBMITTED FOR REVIEW AS AN AMENDED SET OF
 CONSTRUCTION DOCUMENTS.
  
 2) FLAT ROOFS: SUBMIT PRODUCT APPROVAL. 2014 FBC-B
 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.4.1
 COMPONENTS & CLADDING. FLORIDA DEPARTMENT OF COMMUNITY
 AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, RULE 9N-3
 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR
 CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS:
 (31(D) ROOFING PRODUCTS AND ASSEMBLIES,
  
 3) FLAT ROOF NO PARAPET. ROOFING: FOR ALL ROOFING
 PRODUCTS PLEASE IDENTIFY ALL ROOFING SUB-SYSTEMS AND
 THEIR ASSOCIATED PRESSURES FOR ROOF ZONE # 1. REVIEW
 THE PRODUCT APPROVAL LIMITATIONS, IF ENHANCED FASTENING
 IS ALLOWED FOR ROOF ZONES 2 & 3. FASTENER DENSITIES
 SHALL BE INCREASED FOR BOTH INSULATION & THE BASE SHEET
 AS CALCULATED IN COMPLIANCE WITH ROOFING APPLICATION
 STANDARDS RAS 117. CALCULATION PREPARED, SIGNED AND
 SEALED BY A FLORIDA REGISTERED PROFESSIONAL ENGINEER OR
 REGISTERED ARCHITECT. 1609.6.4.4.1 COMPONENTS &
 CLADDING.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2017-11-17 Time   Rev Time 0.00
Received By cpuell Date 2017-11-13 Time 10:23 Sent To  
Notes
2017-11-14 10:23:27JWITMER'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2017-11-03 Time   Rev Time 0.00
Received By lmarchan Date 2017-11-01 Time 14:28 Sent To  
Notes
2017-11-02 14:28:42REVISION ROUTED TO JWITMER


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved