Plan Review Details - Permit 17110003
| Plan Review Stops For Permit 17110003 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2018-01-29 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-01-29 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-01-29 |
Time |
10:32 |
Sent To |
|
|
| Notes |
| 2018-01-29 10:40:17 | PREVIOUSLY ADDED PRIVISOS. | | | | | | IMPACT FEES PASSED REVIEW. | | | | | | THRESHOLD - RESIDENT INSPETOR FAILED REVIEW. | | | | | | ADDRESSING LABELS STILL MISSING. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-01-18 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-01-18 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-01-18 |
Time |
08:38 |
Sent To |
|
|
| Notes |
| 2018-01-18 08:40:56 | | | | BUILDING PROVISOS / DEFERRED SUBMITTALS | | | | | | | | | | | | 8) BUILDING PROVISO/ 107.3.4.2 DEFERRED SUBMITTALS. | | | PLEASE PROVIDE COMPLIANCE WITH 2014 FBC-B 1609.1.2 | | | PROTECTION OF OPENINGS, 1609.6.4.4.1 COMPONENTS & | | | CLADDING. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS, | | | ADMINISTRATIVE CODE 61G20-3.005, RULE 9N-3 NOV. 01/ | | | 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS ,MULLIONS & ROOF HATCHES. | | | (B) WINDOWS & MULLIONS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | | LOUVERS, EFIS SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF TOP | | | VENTILATORS | | | (G) PRE-ENGINEERED A/C STANDS | | | | | | 9A) BUILDING PROVISO/ 107.3.4.2 DEFERRED SUBMITTALS. | | | IDENTIFY GLAZING/ MULLIONS. PLEASE IDENTIFY ON THE | | | PRODUCT APPROVAL BEFORE SUBMITTING TO DESIGNER OF | | | RECORD AND BEFORE SUBMISSION TO THE BUILDING | | | DEPARTMENT. FOR ALL PRODUCTS WITH GLAZING, PLEASE | | | IDENTIFY THE OPENING WIDTH & HEIGHT, TYPE OF GLAZING, | | | MULLION SIZE, LENGTH IF UNREINFORCED OR REINFORCED | | | INFORMATION IF REQUIRED, ATTACHMENTS AND ASSOCIATE | | | PRESSURES FOR EACH OPENING SIZE. 2014 FBC-B 1405.13.1 | | | INSTALLATION. WINDOWS AND DOORS SHALL BE INSTALLED IN | | | ACCORDANCE WITH APPROVED MANUFACTURERS INSTRUCTIONS. | | | FASTENER SIZE AND SPACING SHALL BE PROVIDED IN SUCH | | | INSTRUCTIONS AND SHALL BE CALCULATED BASED ON MAXIMUM | | | LOADS AND SPACING USED IN THE TESTS. | | | | | | 9B) ) BUILDING PROVISO/ 107.3.4.2 DEFERRED SUBMITTALS. | | | ROOFING: FOR ALL ROOFING PRODUCTS PLEASE IDENTIFY ALL | | | ROOFING SUB-SYSTEMS AND THEIR ASSOCIATED PRESSURES FOR | | | ROOF ZONE # 1. REVIEW THE PRODUCT APPROVAL LIMITATIONS, | | | IF ENHANCED FASTENING IS ALLOWED FOR ROOF ZONES 2 & 3. | | | FASTENER DENSITIES SHALL BE INCREASED FOR BOTH | | | INSULATION & THE BASE SHEET AS CALCULATED IN COMPLIANCE | | | WITH ROOFING APPLICATION STANDARDS RAS 117. CALCULATION | | | PREPARED, SIGNED AND SEALED BY A FLORIDA REGISTERED | | | PROFESSIONAL ENGINEER OR REGISTERED ARCHITECT. | | | 1609.6.4.4.1 COMPONENTS & CLADDING. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-01-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-01-11 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-01-18 |
Time |
08:37 |
Sent To |
|
|
| Notes |
| 2018-01-11 13:41:42 | 2014 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 17110003 | | | ADD: 2331 NORTHWOOD UNIVERSITY DR. | | | CONT: CHINOOK CONSTRUCTION INC. | | | TEL: 954-776-6700 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | | | | 1ST REVIEW | | | DATE: | | | ACTION: DENIED | | | | | | 1) THIS BUILDING BEING A NEW ATHLETIC BUILDING, | | | CONSTRUCTION TYPE III-B/ TILT-WALL WILL REQUIRE A | | | RESIDENT INSPECTOR FROM THE FOUNDATION, PLACEMENT OF | | | STEEL IN THE WALL PANELS, POURING OF THE CONCRETE WALL | | | PANELS, LIFTING AND PLACEMENT OF WALL PANELS, WALL | | | CONNECTIONS, PLACEMENT OF ROOF BAR JOIST, BRACING, ROOF | | | DECK AS WELL AS ALL COMPONENTS AND CLADDING WILL BE | | | REQUIRED AT THE SITE. | | | 2014 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION, 110.3.9 OTHER | | | INSPECTIONS SERVICES. THE BUILDING OFFICIAL MAY MAKE, | | | OR CAUSE TO BE MADE BY OTHERS, THE INSPECTIONS REQUIRED | | | BY SECTION 109. HE/SHE MAY ACCEPT REPORTS OF INSPECTORS | | | OF RECOGNIZED INSPECTION SERVICES, PROVIDED THAT AFTER | | | INVESTIGATION HE/SHE IS SATISFIED AS TO THEIR | | | QUALIFICATIONS AND RELIABILITY. A CERTIFICATE CALLED | | | FOR BY ANY PROVISION OF THE TECHNICAL CODES SHALL NOT | | | BE BASED ON SUCH REPORTS UNLESS THE SAME ARE IN WRITING | | | AND CERTIFIED BY A RESPONSIBLE OFFICER OF SUCH SERVICE. | | | THE BUILDING OFFICIAL MAY REQUIRE THE OWNER TO EMPLOY | | | AN INSPECTION SERVICE IN THE FOLLOWING INSTANCES: | | | | | | 1. WHERE THE CONCRETE DESIGN IS BASED ON COMPRESSIVE | | | STRENGTH (F ?C) IN EXCESS OF 3000 | | | POUNDS PER SQUARE INCH | | | 2. FOR BUILDINGS AND STRUCTURES OF UNUSUAL DESIGN OR | | | METHODS OF CONSTRUCTION (TILT WALL). | | | | | | 1A)SEMI-COMPLIED. RESIDENT INSPECTOR FORMS MUST BE | | | SIGNED BY ALL PARTIES NOTARIZED AND RETURNED TO THE | | | BUILDING DEPARTMENT. | | | MISSING SIGNATURES: | | | OWNERS PAGE 4 | | | CONTRACTOR PAGE 5 | | | ARCHITECT PAGE 5 | | | STRUCTURAL ENGINEER PAGE 5 | | | | | | 1B-E) COMPLIED. | | | | | | 1F) INFORMATIONAL, NO NEED TO RESPOND. PLEASE CALL THE | | | CITY OF WEST PALM BEACHS AUTOMATED TELEPHONE | | | INSPECTIONS LINE (561) 805-6700) FOR IN-PROGRESS | | | INSPECTIONS FOR AUDITING OF JOBSITE INSPECTIONS. | | | | | | 2) COMPLIED. GFA INTERNATIONAL SOILS REPORTS. | | | | | | 3)COMPLIED. FINISH FLOOR ELEVATION 16.50 NAVD88. | | | | | | 4-7 COMPLIED. | | | | | | 8) BUILDING PROVISO/ 107.3.4.2 DEFERRED SUBMITTALS. | | | PLEASE PROVIDE COMPLIANCE WITH 2014 FBC-B 1609.1.2 | | | PROTECTION OF OPENINGS, 1609.6.4.4.1 COMPONENTS & | | | CLADDING. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS, | | | ADMINISTRATIVE CODE 61G20-3.005, RULE 9N-3 NOV. 01/ | | | 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS ,MULLIONS & ROOF HATCHES. | | | (B) WINDOWS & MULLIONS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | | LOUVERS, EFIS SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF TOP | | | VENTILATORS | | | (G) PRE-ENGINEERED A/C STANDS | | | | | | 9A) BUILDING PROVISO/ 107.3.4.2 DEFERRED SUBMITTALS. | | | IDENTIFY GLAZING/ MULLIONS. PLEASE IDENTIFY ON THE | | | PRODUCT APPROVAL BEFORE SUBMITTING TO DESIGNER OF | | | RECORD AND BEFORE SUBMISSION TO THE BUILDING | | | DEPARTMENT. FOR ALL PRODUCTS WITH GLAZING, PLEASE | | | IDENTIFY THE OPENING WIDTH & HEIGHT, TYPE OF GLAZING, | | | MULLION SIZE, LENGTH IF UNREINFORCED OR REINFORCED | | | INFORMATION IF REQUIRED, ATTACHMENTS AND ASSOCIATE | | | PRESSURES FOR EACH OPENING SIZE. 2014 FBC-B 1405.13.1 | | | INSTALLATION. WINDOWS AND DOORS SHALL BE INSTALLED IN | | | ACCORDANCE WITH APPROVED MANUFACTURERS INSTRUCTIONS. | | | FASTENER SIZE AND SPACING SHALL BE PROVIDED IN SUCH | | | INSTRUCTIONS AND SHALL BE CALCULATED BASED ON MAXIMUM | | | LOADS AND SPACING USED IN THE TESTS. | | | | | | 9B) ) BUILDING PROVISO/ 107.3.4.2 DEFERRED SUBMITTALS. | | | ROOFING: FOR ALL ROOFING PRODUCTS PLEASE IDENTIFY ALL | | | ROOFING SUB-SYSTEMS AND THEIR ASSOCIATED PRESSURES FOR | | | ROOF ZONE # 1. REVIEW THE PRODUCT APPROVAL LIMITATIONS, | | | IF ENHANCED FASTENING IS ALLOWED FOR ROOF ZONES 2 & 3. | | | FASTENER DENSITIES SHALL BE INCREASED FOR BOTH | | | INSULATION & THE BASE SHEET AS CALCULATED IN COMPLIANCE | | | WITH ROOFING APPLICATION STANDARDS RAS 117. CALCULATION | | | PREPARED, SIGNED AND SEALED BY A FLORIDA REGISTERED | | | PROFESSIONAL ENGINEER OR REGISTERED ARCHITECT. | | | 1609.6.4.4.1 COMPONENTS & CLADDING. | | | | | | 10A) ) BUILDING PROVISO/ 107.3.4.2 DEFERRED SUBMITTALS. | | | W. P. B. 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 10B) BUILDING PROVISO/ 107.3.4.2 DEFERRED SUBMITTALS. | | | DELEGATED ENGINEERING. 61G15-30.003 ENGINEERING | | | DOCUMENT CLASSIFICATION. FL 61G-15-30.006 (3) THE | | | DELEGATED ENGINEER SHALL FORWARD THE DELEGATED | | | ENGINEERING DOCUMENTS TO THE ENGINEER OF RECORD FOR | | | REVIEW. | | | | | | 10C) 107.3.4.2 DEFERRED SUBMITTALS. | | | | | | 11-12) COMPLIED | | | | | | 13)2ND REQUEST. IMPACT FEES. BEFORE A PERMIT TO | | | CONSTRUCT, MAY BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT SET OF PLANS MUST | | | BE STAMPED BY THAT OFFICE, AND A COPY OF THE PAID | | | RECEIPT ATTACHED TO THE PERMIT APPLICATION. PLEASE CALL | | | (561)233-5025 FOR MORE INFORMATION. | | | | | | 14) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | | AS NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-12-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-12-05 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-11-20 |
Time |
15:29 |
Sent To |
|
|
| Notes |
| 2017-12-04 17:41:55 | 2014 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 17110003 | | | ADD: 2331 NORTHWOOD UNIVERSITY DR. | | | CONT: CHINOOK CONSTRUCTION INC. | | | TEL: 954-776-6700 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | | | | 1ST REVIEW | | | DATE: | | | ACTION: DENIED | | | | | | 1) THIS BUILDING BEING A NEW ATHLETIC BUILDING, | | | CONSTRUCTION TYPE III-B/ TILT-WALL WILL REQUIRE A | | | RESIDENT INSPECTOR FROM THE FOUNDATION, PLACEMENT OF | | | STEEL IN THE WALL PANELS, POURING OF THE CONCRETE WALL | | | PANELS, LIFTING AND PLACEMENT OF WALL PANELS, WALL | | | CONNECTIONS, PLACEMENT OF ROOF BAR JOIST, BRACING, ROOF | | | DECK AS WELL AS ALL COMPONENTS AND CLADDING WILL BE | | | REQUIRED AT THE SITE. | | | 2014 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION, 110.3.9 OTHER | | | INSPECTIONS SERVICES. THE BUILDING OFFICIAL MAY MAKE, | | | OR CAUSE TO BE MADE BY OTHERS, THE INSPECTIONS REQUIRED | | | BY SECTION 109. HE/SHE MAY ACCEPT REPORTS OF INSPECTORS | | | OF RECOGNIZED INSPECTION SERVICES, PROVIDED THAT AFTER | | | INVESTIGATION HE/SHE IS SATISFIED AS TO THEIR | | | QUALIFICATIONS AND RELIABILITY. A CERTIFICATE CALLED | | | FOR BY ANY PROVISION OF THE TECHNICAL CODES SHALL NOT | | | BE BASED ON SUCH REPORTS UNLESS THE SAME ARE IN WRITING | | | AND CERTIFIED BY A RESPONSIBLE OFFICER OF SUCH SERVICE. | | | THE BUILDING OFFICIAL MAY REQUIRE THE OWNER TO EMPLOY | | | AN INSPECTION SERVICE IN THE FOLLOWING INSTANCES: | | | | | | 1. WHERE THE CONCRETE DESIGN IS BASED ON COMPRESSIVE | | | STRENGTH (F ?C) IN EXCESS OF 3000 | | | POUNDS PER SQUARE INCH | | | | | | 2. FOR BUILDINGS AND STRUCTURES OF UNUSUAL DESIGN OR | | | METHODS OF CONSTRUCTION (TILT WALL). | | | | | | 1A) RESIDENT INSPECTOR FORMS MUST BE SIGNED BY ALL | | | PARTIES NOTARIZED AND RETURNED TO THE BUILDING | | | DEPARTMENT. | | | | | | 1B) FOR THE RESIDENT INSPECTOR PLEASE PROVIDE A RESUME' | | | OF INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE | | | RESUME' MUST BE ACCOMPANIED BY ALL CERTIFICATES AS | | | SPECIFIED HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE | | | WILL REVIEW THE RESUME'. AFTER THE RESUME' IS REVIEWED, | | | AN INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES | | | WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST | | | MEETING THE ABOVE CRITERIA. | | | | | | 1C) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR | | | HISTORY FOR THIS TYPE OF CONSTRUCTION. | | | | | | 1D) COMPLIED. NOTE FOR PAPER PLANS 3 SETS OF DOCUMENTS | | | ARE REQUIRED. | | | | | | 1E) 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 110.3.9 AND | | | GUIDELINES AND POLICIES FOR PROJECTS CONCERNING | | | RESIDENT INSPECTORS. COMMENT # 14. 3 COPIES OF ALL SHOP | | | DRAWINGS (HANDRAILS, PRECAST JOINT AND SLABS, PRODUCT | | | APPROVALS, TRUSSES, BAR JOIST, ETC.) MUST BE SUBMITTED | | | TO THE BUILDING DEPARTMENT. TWO REVIEWED SETS OF | | | DOCUMENTS WILL BE RETURNED TO THE JOB SITE BEFORE ANY | | | OF THE ABOVE ARE INSTALLED ON THE JOB. | | | | | | 1F) INFORMATIONAL, NO NEED TO RESPOND. PLEASE CALL THE | | | CITY OF WEST PALM BEACH?S AUTOMATED TELEPHONE | | | INSPECTIONS LINE (561) 805-6700) FOR IN-PROGRESS | | | INSPECTIONS FOR AUDITING OF JOBSITE INSPECTIONS. | | | | | | 2) THE GFA INTERNATIONAL SOILS REPORTS, (3) WERE | | | SUBMITTED BUT THEY ARE NOT ORIGINAL SIGNED AND SEALED | | | DOCUMENTS. THEY WERE DOWNLOADED AND PRINTED. THE | | | SIGNATURE WAS TO BE DIGITAL WITH THE COSIGN BEING ABLE | | | TO VERIFY THE SIGNATURE. | | | | | | FLORIDA ADMINISTRATIVE CODE 61G15-23.005 (3)(C) A | | | SCANNED, FACSIMILE, DIGITALLY CREATED OR COPIED IMAGE | | | OF THE LICENSEE?S SIGNATURE SHALL NOT BE USED ON | | | ELECTRONICALLY SIGNED AND SEALED ENGINEERING PLANS, | | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | | | | | 3) SHEET A3.0 AND SHEET S2.0 BOTH INDICATE THE FINISH | | | FLOOR ELEVATION AT 0 FEET 0 INCHES. SHEET S2.0 NOTE # 2 | | | INDICATES SEE CIVIL FOR ACTUAL ELEVATION. CIVIL SHEET | | | GN-1 NOTE # 4 INDICATES VERTICAL DATUM. NORTH AMERICAN | | | VERTICAL DATUM OF ELEVATION = 1988 (NAVD 88) AND | | | REFERENCED TO PALM BEACH COUNTY BENCHMARK (BIRCH) | | | ELEVATION 19.04 CONVERSION EQUATION NAVD 88 = NGVD 29 - | | | 1.529. | | | SHEET PD-0 STATE THE FINISH FLOOR FOR THE ATHLETIC | | | BUILDING ARE A MINIMUM ELEVATION OF 16.50 AFF MINIMUM. | | | IN THE BOTTOM LEFT HAND SIDE OF THE SAME SHEET IT | | | STATES ELEVATIONS ARE REFER TO VERTICAL DATUM OF NAVD | | | 88. CONVERSION EQUATION: NAVD 88 = NGVD 29 ? 1.529. | | | | | | PLEASE NOTE AS OF OCT. 05/ 2017 THE CITY OF WEST PALM | | | BEACH ADOPTED THE NEW FLOOD MAPS WHICH ARE IN NAVD 88. | | | PLEASE REFERENCE NOT ONLY IN THE CIVIL BUT ALSO THE | | | A3.0 AND S2.0 THE VERTICAL DATUM OF NAVD 88 AND THE | | | FINISH FLOOR HEIGHT IN NAVD 88. THERE HAS BEEN A | | | BUILDING THAT STARTED BUILDING 18 INCHES TO LOW. THIS | | | BUILDING IS NOT IN A FLOOD ZONE REQUIRING A FLOOD | | | ELEVATION CERTIFICATE AT THE POURING OF THE FLOOR SLAB. | | | THAT WOULD BE WHEN IT WOULD BE CAUGHT IT WAS POURED TO | | | LOW!!!! 107.2.1.3. ADDITIONAL INFORMATION IS REQUIRED. | | | THE CITY HAS BUILDINGS THAT ARE BEING BUILT UNDER BOTH | | | VERTICAL DATUMS PERMITS THAT CAME IN BEFORE 10/05/17 | | | OLD VERTICAL DATUM (NGVD 29) AND AFTER OCT. 05/ 17 THE | | | NEW VERTICAL DATUM (NAVD88). | | | | | | 4) DISCREPANCY IN PLANS SHEET A2.0 UNDER THE HEADING | | | BUILDING DATA INDICATES THE ROOF SYSTEM TO BE RIGID | | | INSULATION ON METAL DECK. SHEET A6.1 DETAIL NUMBER 3 | | | INDICATES 3.1 INCHES OF RIGID ISO INSULATION BOARD | | | MINIMUM R-19. | | | THE ENERGY CALCULATIONS PAGE 4 INDICATES A R VALUE OF | | | 20.3 BATT INSULATION & 3/8 INCH BUILT UP ROOF. WHEREAS | | | SHEET A6.1 DETAIL NUMBER 2 INDICATES FIBER TITE SM | | | SINGLE PLY MEMBRANE ROOFING. | | | PLEASE ALSO REVIEW THE SHEET S4.1 DETAIL 8 INDICATES A | | | 3 INCH CONCRETE ROOF ON METAL DECKING. THERE IS A | | | DISCREPANCY BETWEEN THE ENERGY CALCULATIONS, | | | ARCHITECTURAL SHEETS AND STRUCTURAL SHEETS AS TO THE | | | ROOFING ASSEMBLY AND INSULATION. | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION 107.2.1.2 FOR ROOF ASSEMBLIES REQUIRED | | | BY THE CODE, THE CONSTRUCTION DOCUMENTS SHALL | | | ILLUSTRATE, DESCRIBE AND DELINEATE THE TYPE OF ROOFING | | | SYSTEM, MATERIALS, FASTENING REQUIREMENTS, FLASHING | | | REQUIREMENTS AND WIND RESISTANCE RATING THAT ARE | | | REQUIRED TO BE INSTALLED. | | | | | | 5) DISCREPANCY BETWEEN THE PLANS AND ENERGY | | | CALCULATIONS. SHEET A4.0 LIST DOORS AND SHEET A11.0 | | | TYPES OF DOORS: | | | DOOR NUMBER 01 & 11 AS ALUMINUM STOREFRONT | | | DOOR NUMBERS 15, 16, 17, 20, 21, 22, 26, 28 & 29 AS | | | FLUSH 1 ? INCH 16 GA. INSULATED H METAL DOORS WHEREAS | | | THE ENERGY CALCS PAGE 08 INDICATE THE DOORS ARE TO BE | | | 2.25 SOLID CORE FLUSH DOORS. DISCREPANCY IN THE ENERGY | | | CODE AND THE PLANS. 107.2.1.3 ADDITIONAL INFORMATION IS | | | REQUIRED. | | | | | | 6) SHEET A7.0 AND A7.1 ZONE 4 THE NEGATIVE PRESSURES | | | ARE 2.9 LBS. LOW, ZONE 5 THE NEGATIVE PRESSURES ARE 4.2 | | | LBS. LOW EVEN WHEN YOU ARE FIGURING THE MEAN ROOF | | | HEIGHT OF 15 FEET. FBC-B 1603.1.4 & TABLE 1609.7(2). | | | | | | 7) SHEET S2.1 INDICATES THE ROOF PRESSURES FOR ROOF | | | ZONES 1 AND 2, PRESSURES ARE GOOD, BUT THE PLANS DO NOT | | | INDICATE A ROOF ZONE 3. ASCE 7-10 FIGURE 30.4-2A NOTE # | | | 5 REQUIRES THE PARAPET EQUAL TO OR HIGHER THAN 3 FEET | | | IS PROVIDED AROUND THE PERIMETER OF THE ROOF WITH 0 | | | DEGREES AND NOT MORE THAN OR EQUAL TO 7 DEGREES. THE | | | ROOF TOP PARAPET IS LESS THAN 3 FEET IN MANY AREAS. | | | PLEASE PROVIDE THE ROOF TOP PRESSURES FOR ZONE 3. | | | | | | 8) PLEASE PROVIDE COMPLIANCE WITH 2014 FBC-B 1609.1.2 | | | PROTECTION OF OPENINGS, 1609.6.4.4.1 COMPONENTS & | | | CLADDING. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS, | | | ADMINISTRATIVE CODE 61G20-3.005, RULE 9N-3 NOV. 01/ | | | 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS ,MULLIONS & ROOF HATCHES. | | | (B) WINDOWS & MULLIONS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | | LOUVERS, EFIS SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF TOP | | | VENTILATORS | | | (G) PRE-ENGINEERED A/C STANDS | | | | | | 9A) IDENTIFY GLAZING/ MULLIONS. PLEASE IDENTIFY ON THE | | | PRODUCT APPROVAL BEFORE SUBMITTING TO DESIGNER OF | | | RECORD AND BEFORE SUBMISSION TO THE BUILDING | | | DEPARTMENT. FOR ALL PRODUCTS WITH GLAZING, PLEASE | | | IDENTIFY THE OPENING WIDTH & HEIGHT, TYPE OF GLAZING, | | | MULLION SIZE, LENGTH IF UNREINFORCED OR REINFORCED | | | INFORMATION IF REQUIRED, ATTACHMENTS AND ASSOCIATE | | | PRESSURES FOR EACH OPENING SIZE. 2014 FBC-B 1405.13.1 | | | INSTALLATION. WINDOWS AND DOORS SHALL BE INSTALLED IN | | | ACCORDANCE WITH APPROVED MANUFACTURER?S INSTRUCTIONS. | | | FASTENER SIZE AND SPACING SHALL BE PROVIDED IN SUCH | | | INSTRUCTIONS AND SHALL BE CALCULATED BASED ON MAXIMUM | | | LOADS AND SPACING USED IN THE TESTS. | | | | | | 9B) ROOFING: FOR ALL ROOFING PRODUCTS PLEASE IDENTIFY | | | ALL ROOFING SUB-SYSTEMS AND THEIR ASSOCIATED PRESSURES | | | FOR ROOF ZONE # 1. REVIEW THE PRODUCT APPROVAL | | | LIMITATIONS, IF ENHANCED FASTENING IS ALLOWED FOR ROOF | | | ZONES 2 & 3. FASTENER DENSITIES SHALL BE INCREASED FOR | | | BOTH INSULATION & THE BASE SHEET AS CALCULATED IN | | | COMPLIANCE WITH ROOFING APPLICATION STANDARDS RAS 117. | | | CALCULATION PREPARED, SIGNED AND SEALED BY A FLORIDA | | | REGISTERED PROFESSIONAL ENGINEER OR REGISTERED | | | ARCHITECT. 1609.6.4.4.1 COMPONENTS & CLADDING. | | | | | | 10A) W. P. B. 107.3.4.1 PRODUCT APPROVALS. THOSE | | | PRODUCTS WHICH ARE REGULATED BY THE DCA RULE 9N-03 | | | SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. FL 61G1-23.015 (2) THE | | | ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND REVIEWING | | | ALL PROJECT DATA, REPORTS, SHOP DRAWINGS ETC.. | | | | | | 10B)DELEGATED ENGINEERING. 61G15-30.003 ENGINEERING | | | DOCUMENT CLASSIFICATION. FL 61G-15-30.006 (3) THE | | | DELEGATED ENGINEER SHALL FORWARD THE DELEGATED | | | ENGINEERING DOCUMENTS TO THE ENGINEER OF RECORD FOR | | | REVIEW. | | | | | | 10C) 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF | | | THIS SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS | | | FOR REVIEW BY THE BUILDING OFFICIAL. | | | | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | | | | 11) SHEET A4.0 RESTROOMS 114, 118 & 121 ALL SHOW 6 OR | | | MORE WATER CLOSETS AND OR COMBINATION OF WATER CLOSETS | | | AND URINALS. PLEASE SHOW COMPLIANCE WITH THE 2014 | | | ACCESSIBILITY CODE 213.3.1 TOILET COMPARTMENTS. WHERE | | | TOILET COMPARTMENTS ARE PROVIDED, AT LEAST ONE TOILET | | | COMPARTMENT SHALL COMPLY WITH 604.8.1. IN ADDITION TO | | | THE COMPARTMENT REQUIRED TO COMPLY WITH 604.8.1, AT | | | LEAST ONE COMPARTMENT SHALL COMPLY WITH 604.8.2 WHERE | | | SIX OR MORE TOILET COMPARTMENTS ARE PROVIDED, OR WHERE | | | THE COMBINATION OF URINALS AND WATER CLOSETS TOTALS SIX | | | OR MORE FIXTURES. | | | 604.8.2 AMBULATORY ACCESSIBLE COMPARTMENTS. | | | FIGURE 604.8.2 AMBULATORY ACCESSIBLE TOILET COMPARTMENT | | | 604.8.2.1 SIZE. | | | 604.8.2.2 DOORS. | | | 604.8.2.3 GRAB BARS. | | | | | | 12) SHEET A4.6 PLANS SHOWING TYPICAL A.D.A. COMPLIANCE | | | DETAILS. | | | | | | 12A) SIGNAGE AT DOORS, SIGNAGE CENTERED 60 INCHES ABOVE | | | THE FLOOR. PLEASE REVIEW SECTION 703.4.1. FOR THE | | | HEIGHT OF TACTILE CHARACTERS. | | | 703.4.1 HEIGHT ABOVE FINISH FLOOR OR GROUND. TACTILE | | | CHARACTERS ON SIGNS SHALL BE LOCATED 48 INCHES | | | (BRAILLE, TOP OF BRAILLE, REACH RANGES) MINIMUM ABOVE | | | THE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE | | | BASELINE OF THE LOWEST TACTILE CHARACTER AND 60 INCHES | | | (1525 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND | | | SURFACE, MEASURED FROM THE BASELINE OF THE HIGHEST | | | TACTILE CHARACTER. | | | | | | 12B) HIGH & LOW SIDE REACH RANGE SHOWS A 54 INCHES | | | PLEASE REVIEW 2014 FBC-ACCESSIBILITY CODE 308.3.1. | | | | | | 13) IMPACT FEES. BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. | | | THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE | | | PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 14) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | | AS NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-01-17 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-01-17 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-01-17 |
Time |
08:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-12-06 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-12-06 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-12-06 |
Time |
16:00 |
Sent To |
|
|
| Notes |
| 2017-12-06 16:49:30 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE CORRECT ADDRESS FOR PROJECT ON PLANS. FBC | | | 107.2.1 | | | 2. BE ADVISED THAT FIRE ALARM, LOW VOLTAGE SYSTEMS, | | | LIGHTNING PROTECTION, GENERATORS, COMMERCIAL HOOD | | | SYSTEMS, SIGNS, SITE LIGHTING, AND SWIMMING POOLS | | | (WHERE APPLICABLE) ARE NOT INCLUDED IN THE SCOPE OF | | | THIS PLAN REVIEW. PROVIDE A BLOCK NOTE INDICATING THE | | | REQUIRED SEPARATE PERMITS AND DATA SPECIFICATION SHEET | | | SUBMITTALS FOR ANY OF THESE SYSTEMS PRESENT. FBC 105.1, | | | 107.2.1 | | | 3. WIREWAY FOR SERVICE NEEDS TO BE RATED FOR OUTSIDE | | | ENVIRONMENT. PROVIDE CORRECTION. NEC 376.10 | | | 4. RISER DIAGRAM SHOWS A TRANSFORMER INSTALLED OUTSIDE | | | AFTER MAIN # 2. PROVIDE SPEC SHEETS FOR THIS UNIT, | | | SHOWING IT IS RATED FOR OUTDOORS. NEC 110.3 | | | 5. PROVIDE GFCI PROTECTION FOR ALL RECEPTACLE OUTLETS | | | IN LOCKER ROOMS. NEC 210.8(B)(7) | | | 6. PROVIDE RECEPTACLE CONTROL REQUIRED BY ASHREA 90.1: | | | 8.4.2. PER THIS REQUIREMENT, THE FOLLOWING SHALL BE | | | AUTOMATICALLY CONTROLLED: 1) AT LEAST 50% OF ALL | | | 125-VOLT, 15 AND 20 AMP RECEPTACLES, IN ALL PRIVATE | | | OFFICES, CONFERENCE ROOMS, ROOMS USED PRIMARILY FOR | | | PRINTING AND/OR COPYING FUNCTIONS, BREAK ROOMS, | | | CLASSROOMS, AND INDIVIDUAL WORKSTATIONS. 2) AT LEASE | | | 25% OF BRANCH CIRCUIT FEEDERS INSTALLED FOR MODULAR | | | FURNITURE NOT SHOWN ON THE CONSTRUCTION DOCUMENTS. FBC | | | EC 405.7.1 | | | 7. PROVIDE BONDING DETAILS FOR THE WHIRLPOOL | | | THERAPEUTIC TUBS. NEC 680.62(B) AND (C). | | | 8. WATER HEATER # 1 IS SHOWN TWICE ON PLAN AND PANEL | | | SCHEDULES. EACH CIRCUIT IS REQUIRED TO HAVE A UNIQUE | | | NAME. PROVIDE CORRECTION. NEC 408.4 | | | 9. PROVIDE NOTES TO INDICATE THE REQUIRED MARKING OF | | | SERVICE EQUIPMENT FOR ARC FLASH HAZARD WARNING. NEC | | | 110.16 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
N |
Date |
2018-01-18 |
|
|
Cont ID |
|
| Sent By |
Mgonzale |
Date |
2018-01-18 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2018-01-18 |
Time |
|
Sent To |
I |
|
| Notes |
| 2018-01-18 12:48:13 | PROJECT IS UNDER SEPARATE REVIEW THRU ENGINEERING | | | SERVICES DEPT. | | | | | | MANNY GONZALEZ | | | ENGINEERING PROJECT COORDINATOR | | | PUBLIC WORKS DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | EMAIL: [email protected] | | | HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS | | | /FORMS,-PERMITS-APPLICATIONS | | | | | | IMPORTANT MESSAGE: AS OF DECEMBER 20, 2015 THE CITY OF | | | WEST PALM BEACH | | | CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED, | | | MAKING KNOWN THAT "ALL BACKFLOW DEVICES MUST BE LEAD | | | FREE." | | | FOR MORE INFORMATION REFER TO THE LINK BELOW: | | | HTTP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PUBLI | | | CATIONS/BACKFLOW-CROSS-CONNECTION-CONTROL-MANUAL |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2017-12-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-12-05 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-12-05 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2017-12-05 11:32:26 | A SEPARATE ENGINEERING PERMIT IS REQUIRED | | | HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR | | | MS,-PERMITS-APPLICATIONS | | | | | | ENGINEERING APPROVAL IS REQUIRED PRIOR TO BUILDING | | | PERMIT ISSUANCE | | | | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-12-28 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-12-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-12-27 |
Time |
15:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2017-11-07 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-11-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-11-07 |
Time |
12:14 |
Sent To |
|
|
| Notes |
| 2017-11-07 14:09:13 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) SHEET A 2.0 - WITHIN THE BUILDING DATA BOX THERE IS | | | AN INDICATION OF A FIRE SPRINKLER SYSTEM. THERE ARE NO | | | FIRE SPRINKLER DOCUMENTS ATTACHED. SHOP DRAWINGS CAN | | | NOT BE ACCEPTED WITHOUT SPRINKLER DOCUMENTS COMPLIANT | | | WITH FS 61G REQUIREMENTS. | | | | | | | | | PER THE FLORIDA BUILDING CODE: | | | | | | 105.3.1.2 | | | NO PERMIT MAY BE ISSUED FOR ANY BUILDING CONSTRUCTION, | | | ERECTION, ALTERATION, MODIFICATION, REPAIR, OR ADDITION | | | UNLESS THE APPLICANT FOR SUCH PERMIT PROVIDES TO THE | | | ENFORCING AGENCY WHICH ISSUES THE PERMIT ANY OF THE | | | FOLLOWING DOCUMENTS WHICH APPLY TO THE CONSTRUCTION FOR | | | WHICH THE PERMIT IS TO BE ISSUED AND WHICH SHALL BE | | | PREPARED BY OR UNDER THE DIRECTION OF AN ENGINEER | | | REGISTERED UNDER CHAPTER 471, FLORIDA STATUTES: | | | 2. FIRE SPRINKLER DOCUMENTS FOR ANY NEW BUILDING OR | | | ADDITION WHICH INCLUDES A FIRE SPRINKLER SYSTEM WHICH | | | CONTAINS 50 OR MORE SPRINKLER HEADS. PERSONNEL AS | | | AUTHORIZED BY CHAPTER 633 FLORIDA STATUTES, MAY DESIGN | | | A FIRE SPRINKLER SYSTEM OF 49 OR FEWER HEADS AND MAY | | | DESIGN THE ALTERATION OF AN EXISTING FIRE SPRINKLER | | | SYSTEM IF THE ALTERATION CONSISTS OF THE RELOCATION, | | | ADDITION OR DELETION OF NOT MORE THAN 49 HEADS, | | | NOTWITHSTANDING THE SIZE OF THE EXISTING FIRE SPRINKLER | | | SYSTEM. | | | | | | | | | PER FLORIDA ADMINISTRATIVE CODE SECTION 61G15-32.004, | | | FIRE PROTECTION ENGINEERING DOCUMENTS SHALL INCLUDE THE | | | POINT OF SERVICE FOR THE WATER SUPPLY, A LIST OF | | | APPLICABLE NFPA STANDARDS APPLICABLE TO THE PROJECT, | | | CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR | | | AREA, SUPPRESSION SYSTEM TYPE, DESIGN DENSITIES, WATER | | | SUPPLY DATA (FIRE PUMP DATA, HYDRANT FLOW TEST DATA) | | | AND ANY PERFORMANCE BASED INFORMATION SUCH AS | | | PRE-ENGINEERED SYSTEMS. | | | | | | 61G15-32.003 COMMON REQUIREMENTS TO ALL FIRE PROTECTION | | | ENGINEERING | | | DOCUMENTS. | | | (1) THE FIRE PROTECTION SYSTEM ENGINEERING DOCUMENTS | | | SHALL PROVIDE THE ENGINEERING REQUIREMENTS TO BE USED | | | IN THE PREPARATION OF THE FIRE PROTECTION SYSTEM LAYOUT | | | DOCUMENTS AND TO INDICATE THE NATURE AND SCOPE OF THE | | | WORK, AND TO DESCRIBE, DETAIL, DIMENSION, LABEL AND | | | DEFINE THE FIRE PROTECTION COMPONENTS, SYSTEM(S), | | | MATERIALS, ASSEMBLIES, EQUIPMENT AND ITS STRUCTURAL AND | | | UTILITY SUPPORT SYSTEM(S), INSOFAR AS THEY INVOLVE THE | | | SAFEGUARDING OF LIFE, HEALTH OR PROPERTY. | | | (2) THE FIRE PROTECTION SYSTEM ENGINEERING DOCUMENTS | | | SHALL SPECIFY THE APPLICABLE REQUIREMENTS FOR THE | | | ACCEPTANCE TESTING OF THE FIRE PROTECTION SYSTEM AND | | | COMPONENTS, WHICH SHALL BE BASED UPON APPLICABLE CODES | | | AND STANDARDS, WHERE AVAILABLE. | | | (3) THE OCCUPANCY OF THE AREA OR DESCRIPTION OF A | | | SPECIFIC HAZARD BEING PROTECTED BY THE FIRE PROTECTION | | | SYSTEM(S) SHALL BE SHOWN ON THE FIRE PROTECTION SYSTEM | | | ENGINEERING DOCUMENTS. | | | (4) THE APPLICABLE CODE AND STANDARD TO BE USED IN THE | | | PREPARATION OF THE FIRE PROTECTION SYSTEM LAYOUT | | | DOCUMENTS SHALL BE SHOWN ON THE FIRE PROTECTION SYSTEM | | | ENGINEERING DOCUMENTS. WHEN CODES AND STANDARDS ARE NOT | | | AVAILABLE OR APPLICABLE, AND SAID LAYOUT DOCUMENTS ARE | | | TO BE BASED ON ENGINEERING JUDGMENT, ANY REASONS AND | | | ASSUMPTIONS MADE TO DEVELOP THE FIRE PROTECTION CONCEPT | | | SHALL BE IDENTIFIED ON THE FIRE PROTECTION SYSTEM | | | ENGINEERING DOCUMENTS. | | | (5) STRUCTURAL SUPPORT AND STRUCTURAL OPENINGS REQUIRED | | | BY THE FIRE PROTECTION SYSTEM SHALL BE SHOWN ON THE | | | FIRE PROTECTION SYSTEM ENGINEERING DOCUMENTS AND SHALL | | | BE REFERENCED ON STRUCTURAL ENGINEERING DOCUMENTS. | | | (6) WHEN LAYOUT DOCUMENTS CONTAIN MATERIAL DEVIATION | | | FROM THE ENGINEER OF RECORD'S FIRE PROTECTION SYSTEM | | | ENGINEERING DOCUMENT, SUCH LAYOUT DOCUMENTS ARE NOT | | | COMPLIANT UNLESS THEY ARE ACCOMPANIED BY REVISED | | | ENGINEERING DOCUMENTS MADE AND SEALED BY THE ENGINEER | | | OF RECORD FOR THE FIRE PROTECTION SYSTEM. | | | (7) REQUIREMENTS FOR ACTIVATION CONTROL SYSTEMS, | | | SEQUENCE, OPERATING PARAMETERS, INTERLOCKS, SAFETY | | | RELATED DEVICES, INDICATORS AND ALARMS, SHALL BE SHOWN | | | ON THE FIRE PROTECTION SYSTEM ENGINEERING DOCUMENTS, | | | UNLESS SHOWN ON OTHER RELATED DOCUMENTS. | | | (8) ANY INFORMATION DEEMED APPROPRIATE BY THE ENGINEER | | | OF RECORD TO ASSIST THE AUTHORITY HAVING JURISDICTION | | | IN UNDERSTANDING THE OWNER?S INTENDED USE AND PROPOSED | | | PROTECTION OF THE BUILDING OR FACILITY AND TO PROVIDE | | | SUFFICIENT DIRECTION TO THE INSTALLATION CONTRACTOR OR | | | OTHER INTERESTED PARTIES REGARDING THE LAYOUT OF THE | | | SYSTEM(S), SHALL BE INCLUDED IN THE FIRE PROTECTION | | | SYSTEM ENGINEERING DOCUMENTS. | | | SPECIFIC AUTHORITY 471.008, 471.033(2), FS | | | LAW IMPLEMENTED 471.005(7), 471.033(2), FS | | | HISTORY?NEW 5-19-93, FORMERLY 21H-32.003, AMENDED | | | 4-2-2000, 6-26-01 | | | | | | 61G15-32.004 DESIGN OF WATER BASED FIRE PROTECTION | | | SYSTEMS. | | | (1) WATER BASED FIRE PROTECTION SYSTEMS INCLUDE, BUT | | | ARE NOT LIMITED TO, AUTOMATIC SPRINKLER SYSTEMS OF WET, | | | DRY, FINE WATER SPRAY (MIST), MANUAL, AND DELUGE VALVE | | | CONTROLLED TYPES, PUMPING SYSTEMS, STANDPIPES, FIRE | | | WATER MAINS AND DEDICATED FIRE PROTECTION WATER | | | SOURCES. | | | (2) TO ENSURE MINIMUM DESIGN QUALITY IN FIRE PROTECTION | | | SYSTEM ENGINEERING DOCUMENTS, SAID DOCUMENTS SHALL | | | INCLUDE AS A MINIMUM THE FOLLOWING INFORMATION WHEN | | | APPLICABLE: | | | (A) THE POINT OF SERVICE FOR THE FIRE PROTECTION WATER | | | SUPPLY AS DEFINED BY 633.021(18) F.S. | | | (B) APPLICABLE NFPA STANDARD TO BE APPLIED, OR IN THE | | | CASE WHERE NO SUCH STANDARD EXISTS, THE ENGINEERING | | | STUDY, JUDGMENTS, AND/OR PERFORMANCE BASED ANALYSIS AND | | | CONCLUSIONS. | | | (C) CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR | | | AREA. | | | (D) DESIGN APPROACH, WHICH INCLUDES SYSTEM TYPE, | | | DENSITIES, DEVICE TEMPERATURE RATING, AND SPACING FOR | | | EACH SEPARATE 42 HAZARD OCCUPANCY. | | | (E) CHARACTERISTICS OF WATER SUPPLY TO BE USED, SUCH AS | | | MAIN SIZE AND LOCATION, WHETHER IT IS DEAD-END OR | | | CIRCULATING; AND IF DEAD-END, THE DISTANCE TO THE | | | NEAREST CIRCULATING MAIN, AS WELL AS ITS MINIMUM | | | DURATION AND RELIABILITY FOR THE MOST HYDRAULICALLY | | | DEMANDING DESIGN AREA. | | | (F) WHEN PRIVATE OR PUBLIC WATER SUPPLIES ARE USED, THE | | | FLOW TEST DATA, INCLUDING DATE AND TIME OF TEST, WHO | | | CONDUCTED TEST OR SUPPLIED INFORMATION, TEST ELEVATION, | | | STATIC GAUGE PRESSURE AT NO FLOW, FLOW RATE WITH | | | RESIDUAL GAUGE PRESSURE, HYDRANT BUTT COEFFICIENT, AND | | | LOCATION OF TEST IN RELATION TO THE HYDRAULIC POINT OF | | | SERVICE. | | | (G) VALVING AND ALARM REQUIREMENTS TO MINIMIZE | | | POTENTIAL FOR IMPAIRMENTS AND UNRECOGNIZED FLOW OF | | | WATER. | | | (H) MICROBIAL INDUCED CORROSION (MIC). THE ENGINEER OF | | | RECORD SHALL MAKE REASONABLE EFFORTS TO IDENTIFY WATER | | | SUPPLIES THAT COULD LEAD TO MICROBIAL INDUCED CORROSION | | | (MIC). SUCH EFFORTS MAY CONSIST OF DISCUSSIONS WITH THE | | | LOCAL WATER PURVEYOR AND/OR FIRE OFFICIAL, FAMILIARITY | | | WITH CONDITIONS IN THE LOCAL AREA, OR LABORATORY | | | TESTING OF WATER SUPPLIES. WHEN CONDITIONS ARE FOUND | | | THAT MAY RESULT IN MIC CONTAMINATION OF THE FIRE | | | PROTECTION PIPING, THE ENGINEER SHALL DESIGN CORRECTIVE | | | MEASURES. | | | (I) BACKFLOW PREVENTION AND METERING SPECIFICATIONS AND | | | DETAILS TO MEET LOCAL WATER PURVEYOR REQUIREMENTS | | | INCLUDING MAXIMUM ALLOWABLE PRESSURE DROP. | | | (J) QUALITY AND PERFORMANCE SPECIFICATIONS OF ALL YARD | | | AND INTERIOR FIRE PROTECTION COMPONENTS. | | | (3) CONTRACTOR SUBMITTALS WHICH DEVIATE FROM THE ABOVE | | | MINIMUM DESIGN PARAMETERS SHALL BE CONSIDERED MATERIAL | | | DEVIATIONS AND REQUIRE SUPPLEMENTAL ENGINEERING | | | APPROVAL AND DOCUMENTATION. | | | (4) IN THE EVENT THE ENGINEER OF RECORD PROVIDES MORE | | | INFORMATION AND DIRECTION THAN IS ESTABLISHED ABOVE, HE | | | OR SHE SHALL BE HELD RESPONSIBLE FOR THE TECHNICAL | | | ACCURACY OF THE WORK IN ACCORDANCE WITH APPLICABLE | | | CODES, STANDARDS, AND SOUND ENGINEERING PRINCIPLES. | | | SPECIFIC AUTHORITY 471.008, 471.033(2), FS | | | LAW IMPLEMENTED 471.005(7), 471.033(2), FS | | | HISTORY?NEW 5-19-93, FORMERLY 21H-32.004, AMENDED | | | 4-2-2000, 6-26-01, 7-12-05 | | | | | | PLEASE PROVIDE FS 61G COMPLIANT DOCUMENTS WITH THIS | | | MASTER PERMIT. SHOP DRAWINGS CAN THEN BE DEVELOPED AND | | | SUBMITTED IN THE FUTURE. | | | | | | THESE DOCUMENTS WILL BE ACCEPTED IN WRITTEN NARRATIVE | | | OR PLAN SHEET SUBMITTAL AS LONG AS THEY COMPLY AND ARE | | | SIGNED AND SEALED BY AN ENGINEER OF RECORD. | | | | | | | | | | | | 2) SHEET A 2.0 - A FIRE ALARM SYSTEM IS NOT INDICATED. | | | PER NFPA 101, CHAPTER 12, NEW ASSEMBLY OCCUPANCIES A | | | FIRE ALARM SYSTEM IS REQUIRED FOR THE BUILDING AND FIRE | | | SPRINKLER MONOTORING. | | | | | | 12.3.4 DETECTION, ALARM, AND COMMUNICATIONS SYSTEMS. | | | 12.3.4.1 GENERAL. | | | 12.3.4.1.1 ASSEMBLY OCCUPANCIES WITH OCCUPANT LOADS OF | | | MORE THAN 300 AND ALL THEATERS WITH MORE THAN ONE | | | AUDIENCE-VIEWING ROOM SHALL BE PROVIDED WITH AN | | | APPROVED FIRE ALARM SYSTEM IN ACCORDANCE WITH 9.6.1 AND | | | 12.3.4, UNLESS OTHERWISE PERMITTED BY 12.3.4.1.2. | | | 12.3.4.1.2 ASSEMBLY OCCUPANCIES THAT ARE A PART OF A | | | MULTIPLE OCCUPANCY PROTECTED AS A MIXED OCCUPANCY (SEE | | | 6.1.14) SHALL BE PERMITTED TO BE SERVED BY A COMMON | | | FIRE ALARM SYSTEM, PROVIDED THAT THE INDIVIDUAL | | | REQUIREMENTS OF EACH OCCUPANCY ARE MET. | | | | | | PLEASE PROVIDE AN APPLICABLE NOTE INDICATING THAT FIRE | | | ALARM SHOP DRAWINGS WILL BE SUBMITTED. | | | | | | | | | | | | 3) SHEETS A 7.0 & 8.0 - THERE ARE INDICATIONS OF | | | LIGHTWEIGHT ROOF TRUSS CONSTRUCTION ELEMENTS. | | | | | | PER FLORIDA 69A-60.0081; NOTICE SIGNAGE IS REQUIRED FOR | | | STRUCTURES WITH LIGHT-FRAME TRUSS-TYPE CONSTRUCTION. | | | ANY COMMERCIAL, INDUSTRIAL, OR ANY MULTIUNIT | | | RESIDENTIAL STRUCTURE OF THREE UNITS OR MORE WHICH USES | | | HORIZONTAL OR VERTICAL LIGHT-FRAME TRUSS-TYPE | | | CONSTRUCTION IN ANY PORTION SHALL BE MARKED WITH A | | | MALTESE CROSS SIGN MEASURING 8 INCHES HORIZONTALLY AND | | | 8 INCHES VERTICALLY, OF A BRIGHT RED REFLECTIVE COLOR. | | | THE APPROVED SYMBOL SHALL BE PLACED WITHIN 24 INCHES TO | | | THE LEFT OF THE MAIN ENTRY DOOR. | | | A. STRUCTURES WITH LIGHT-FRAME TRUSS ROOFS SHALL BE | | | MARKED WITH THE LETTER "R". | | | B. STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR SYSTEMS | | | SHALL BE MARKED WITH THE LETTER "F". | | | C. STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR AND ROOF | | | SYSTEMS SHALL BE MARKED WITH THE LETTERS "R/F". | | | | | | PLEASE PROVIDE AN APPLICABLE NOTE FOR THE REQUIRED R | | | TRUSS SIGN. | | | | | | | | | | | | | | | 4) SHEET 11.0 - THE DOOR SCHEDULE INDICATES LEVER | | | LOCKSETS AND DEADBOLTS ON EXIT DOORS. | | | | | | PER NFPA 101, CHAPTER 12, NEW ASSEMBLEY OCCUPANCIES | | | PANIC HARDWARE IS REQUIRED. | | | | | | 12.2.2.2.3 ANY DOOR IN A REQUIRED MEANS OF EGRESS FROM | | | AN AREA HAVING AN OCCUPANT LOAD OF 100 OR MORE PERSONS | | | SHALL BE PERMITTED TO BE PROVIDED WITH A LATCH OR LOCK | | | ONLY IF THE LATCH OR LOCK IS PANIC HARDWARE OR FIRE | | | EXIT HARDWARE COMPLYING WITH 7.2.1.7, UNLESS OTHERWISE | | | PERMITTED BY ONE OF THE FOLLOWING: | | | (1) THIS REQUIREMENT SHALL NOT APPLY TO DELAYED-EGRESS | | | LOCKS AS PERMITTED IN 12.2.2.2.5. | | | (2) THIS REQUIREMENT SHALL NOT APPLY TO | | | ACCESS-CONTROLLED EGRESS DOORS AS PERMITTED IN | | | 12.2.2.2.6. | | | 12.2.2.2.4 LOCKING DEVICES COMPLYING WITH 7.2.1.5.5 | | | SHALL BE PERMITTED TO BE USED ON A SINGLE DOOR OR A | | | SINGLE PAIR OF DOORS IF BOTH OF THE FOLLOWING | | | CONDITIONS APPLY: | | | (1) THE DOOR OR PAIR OF DOORS SERVE AS THE MAIN EXIT | | | AND THE ASSEMBLY OCCUPANCY HAS AN OCCUPANT LOAD NOT | | | GREATER THAN 500. | | | (2) ANY LATCHING DEVICES ON SUCH A DOOR(S) FROM AN | | | ASSEMBLY OCCUPANCY HAVING AN OCCUPANT LOAD OF 100 OR | | | MORE ARE RELEASED BY PANIC HARDWARE OR FIRE EXIT | | | HARDWARE. | | | | | | PLEASE PROVIDE THE REQUIRED DEVICES ON ALL EXIT DOORS. | | | | | | | | | | | | 5) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 6) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2018-02-01 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-02-01 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-01-31 |
Time |
11:47 |
Sent To |
|
|
| Notes |
| 2018-02-01 11:48:04 | GIVEN TO ACLANGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-01-29 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-01-29 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-01-23 |
Time |
14:39 |
Sent To |
|
|
| Notes |
| 2018-01-25 13:36:50 | 1/25 ROUTED PLAN WHICH WAS RETURNED FROM IMPACT FEE TO | | | GJ DESK, PUT WITH THE OTHER TWO SETS | | | | | 2018-01-24 14:39:34 | RESUB ROUTED TO GJOHNSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-01-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-01-19 |
Time |
17:54 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-12-22 |
Time |
16:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-12-15 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2017-12-15 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2017-11-01 |
Time |
15:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2018-01-29 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-01-29 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-01-29 |
Time |
09:08 |
Sent To |
|
|
| Notes |
| 2018-01-29 09:22:01 | PALM BEACH COUNTY IMPACT FEE PAID | | | RECEPT # 2018 0126 70 | | | TRACKING # MU 2018 002470 0000 | | | 1/25/18 $1,837.39 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2018-01-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-01-11 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-01-11 |
Time |
10:37 |
Sent To |
|
|
| Notes |
| 2018-01-11 13:42:34 | IMPACT FEES | | | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. ONE SET OF | | | PLANS WILL HAVE TO BE TAKEN (BY THE CONTRACTOR OR | | | REPRESENTATIVE) TO THE PALM BEACH COUNTY IMPACT FEE | | | OFFICE LOCATED AT 2300 N. JOG RD. ROOMS 2W01-2W14 WEST | | | PALM BEACH, FL. THE ACTUAL PERMIT SET OF PLANS MUST BE | | | STAMPED BY THAT OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. PLEASE CALL | | | (561)233-5025 FOR MORE INFORMATION. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2017-12-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-12-05 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-11-20 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2017-12-05 11:01:05 | IMPACT FEES | | | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2018-01-12 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-01-11 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-01-11 |
Time |
11:44 |
Sent To |
|
|
| Notes |
| 2018-01-11 14:19:27 | MECHANICAL PROVISO: | | | | | | COMMISSIONING OF THE HVAC SYSTEMS AND ELECTRICAL | | | LIGHTING REQUIRED. | | | | | | COMMISSIONING REPORT REQUIRED FOR CO | | | | | | CCOLE- 1/12/18 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-11-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-11-28 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-11-28 |
Time |
15:08 |
Sent To |
|
|
| Notes |
| 2017-11-28 15:58:55 | 1ST REVIEW FBC-2014 MECHANICAL, ENERGY CONSERVATION | | | CODES | | | PERMIT #17110003 | | | 11/28/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEETS M-1.1 & M-2.1: THE EXHAUST CALCULATIONS ARE | | | INDICATING 1940 CFMS OF EXHAUST PROVIDED FOR THE | | | LOCKER/RESTROOMS/SHOWERS FOR BOTH RTU-3 & 4, HOWEVER | | | THE FLOOR PLAN DRAWING IS INDICATING 2540 CFMS OF | | | EXHAUST FROM THE LOCKERS/SHOWERS/RESTROOMS FOR EACH OF | | | THE SYSTEMS, AND AN ADDITIONAL 350 CFMS OF | | | RETURN/EXHAUST FROM THE OFFICES FOR EACH SYSTEM. BEING | | | THAT THE | | | | | | ERV'S HAVE CAPACITIES OF 1940 CMS, IT APPEARS THAT | | | RECIRCULATION OF AIR EXCEEDING 10% OF THE SUPPLY AIR | | | STREAMS WILL OCCUR- SEE TABLE 403.3 FOOTNOTE G. | | | | | | 2) SHEET M-2.1: INDICATE THE AMOUNT OF MAKEUP AIR BEING | | | TRANSFERRED FROM THE CORRIDOR INTO THE LOCKER ROOMS- | | | REFER TO SECTION 601.2. | | | | | | 3) PLEASE PROVIDE MORE INFORMTION ABOUT THE LAUNDRY | | | ROOM IN COMPLIANCE WITH SECTION 504. A) INDICATE THE | | | NUMBER OF DRYERS IN THE ROOM AND SUBMIT MANUFACTURER'S | | | SPECIFICATIONS. B) CLARIFY IF THE 8" EXHAUST DUCT IS A | | | COMMON EXHAUST DUCT FOR MULTIPLE DRYERS, AND PROVIDE AN | | | ELEVATION DRAWING. C) PROVIDE A MAKEUP AIR CALCULATION | | | INDICATING WHAT IS REQUIRED AND WHAT WILL BE PROVIDED. | | | | | | 4) PLEASE SEE SHEETS S4.1 & M-3.1. THE DETAILS PROVIDED | | | FOR ATTACHING THE RTU'S TO THE CURBS, AND ATTACHING THE | | | CURBS TO THE ROOF STRUCTURE DO NOT MATCH. PLEASE | | | PROVIDE CONSISTENT ENGINEERED DETAILS THAT ARE | | | COMPLIANT WITH SECTION 1609 FBC-14 BUILDING. | | | | | | 5) PROVIDE CONDENSATE DISPOSAL PLANS FOR THE RTU'S. | | | PROVIDE TYPES AND SIZES OF PIPING, PIPING RUNS AND | | | DISCHARGE LOCATIONS, AND PIPING INSULATION DETAILS- | | | SECTION 307. | | | | | | 6) COMMISSIONING OF THE MECHANICAL SYSTEMS IS REQUIRED | | | IN ACCORDANCE WITH SECTION C408.2 FBC-14 ENERGY | | | CONSERVATION. PROVIDE A COMMISSIONING PLAN IN | | | ACCORDANCE WITH SECTION C408.2.1. PLEASE NOTE THAT A | | | COMMISSIONING REPORT IS REQUIRED TO PASS THE FINAL | | | MECHANICAL INSPECTION- SEE SECTIONS C408.2.4- | | | C408.2.5.4. | | | | | | 7) THE ENGINEER OF RECORD ERIC J. SVOBODA P.E. SHALL | | | PROVIDE HIS RAISED OR INK SEAL ON THE CERTIFICATIONS | | | PAGE OF THE ENERGYGAUGE COMPLIANCE FORM- SEE SECTION | | | C103.1.1.1.2. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2018-01-27 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-01-27 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-01-27 |
Time |
10:31 |
Sent To |
|
|
| Notes |
| 2018-01-27 10:39:59 | PROVISO: | | | | | | | | | BEFORE PERMIT IS ISSUED PLEASE CORRECT THE FOLLOWING, | | | IT CAN BE DONE WHEN THE PERMIT IS PICKED UP. | | | | | | 1. REPLACE STICKERS ON THE COVER SHEETS OF ALL THREE | | | PLAN SETS THAT HAVE THE INCORRECT ADDRESS ON THEM. | | | | | | 2. SECURELY STAPLE ALL THREE PLAN SETS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2018-01-17 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-01-17 |
Time |
17:39 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-01-17 |
Time |
17:39 |
Sent To |
|
|
| Notes |
| 2018-01-17 17:07:23 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: PREVIOUS COMMENTS NOT COMPLIED: | | | | | | 1. PREVIOUS COMMENT #1 IN THE TITLE BLOCK ON THE PLAN | | | IT SHOWS THE ADDRESS AS 2600 MILITARY TRAIL, PER THE | | | PERMIT THE ADDRESS SHOULD BE 2331 NORTHWOOD UNIVERSITY | | | DRIVE PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 NEW | | | COMMENT THE ADDRESS ON COVER SHEET AND MULTIPLE PLAN | | | SEETS WAS CHANGED TO 2331 MILITARY TRAIL WPB THIS | | | ADDRESS IS INCORRECT THE CORRECT ADDRESS SHALL BE 2331 | | | NORTHWOOD UNIVERSITY DR WPB | | | | | | 2. PREVIOUS COMMENT #7 (C) 608.2.1 TRANSFER TYPE SHOWER | | | COMPARTMENTS. | | | TRANSFER TYPE SHOWER COMPARTMENTS SHALL BE 36 INCHES | | | (915 MM) BY 36 INCHES (915 MM) CLEAR INSIDE DIMENSIONS | | | MEASURED AT THE CENTER POINTS OF OPPOSING SIDES AND | | | SHALL HAVE A 36 INCH (915 MM) WIDE MINIMUM ENTRY ON THE | | | FACE OF THE SHOWER COMPARTMENT. CLEARANCE OF 36 INCHES | | | (915 MM) WIDE MINIMUM BY 48 INCHES (1220 MM) LONG | | | MINIMUM MEASURED FROM THE CONTROL WALL SHALL BE | | | PROVIDED. NEW SHT. A.4.1 SHOWS DIMENSION OF 38" PLEASE | | | CORRECT TRANSFER TYPE SHOWERS SHALL BE 36" X 36" INSIDE | | | FINISH | | | | | | 3. PREVIOUS COMMENTS #7 ( G) 610.3.2 L-SHAPED SEATS. | | | THE REAR EDGE OF AN L-SHAPED SEAT SHALL BE 21/2 INCHES | | | (64 MM) MAXIMUM AND THE FRONT EDGE 15 INCHES (380 MM) | | | MINIMUM AND 16 INCHES (405 MM) MAXIMUM FROM THE SEAT | | | WALL. THE REAR EDGE OF THE "L" PORTION OF THE SEAT | | | SHALL BE 11/2 INCHES (38 MM) MAXIMUM FROM THE WALL AND | | | THE FRONT EDGE SHALL BE 14 INCHES (355 MM) MINIMUM AND | | | 15 INCHES (380 MM) MAXIMUM FROM THE WALL. THE END OF | | | THE ?L? SHALL BE 22 INCHES (560 MM) MINIMUM AND 23 | | | INCHES MAXIMUM (585 MM) FROM THE MAIN SEAT WALL. NEW | | | NOT SHOWN ON TRANSFER TYPE SHOWER DETAIL. | | | | | | 4. PREVIOUS COMMENT #9 SHT. A4.6 DETAIL , TYPICAL ADA | | | TOILET STALL THE DIMENSION OF THE WC OFF SIDE WALL | | | SHALL BE 16? MIN AND 18? MAX, THE DIMENSION SHOWN | | | 17"MIN 19"MAX IS FOR AMBULATORY STALLS ONLY. PER FBC | | | ACC 604.2 NEW DETAIL STILL SHOWS A DIMENSION OF 17" - | | | 19" | | | | | | 5. PREVIOUS COMMENT #21 ALL DRY VENTS SHALL COMPLY WITH | | | FBC PL | | | A) 905.3 VENT CONNECTION TO DRAINAGE SYSTEM. | | | EVERY DRY VENT CONNECTING TO A HORIZONTAL DRAIN SHALL | | | CONNECT ABOVE THE CENTERLINE OF THE HORIZONTAL DRAIN | | | PIPE. | | | B) 905.4 VERTICAL RISE OF VENT. | | | EVERY DRY VENT SHALL RISE VERTICALLY TO A POINT NOT | | | LESS THAN 6 INCHES (152 MM) ABOVE THE FLOOD LEVEL RIM | | | OF THE HIGHEST TRAP OR TRAPPED FIXTURE BEING VENTED. | | | NEW ALL DRY VENTS SHALL CONNECT TO THE TOP OF | | | HORIZONTAL DRAIN AND SHALL RISE VERTICALLY ABOVE FLOOD | | | LEVEL RIM OF FIXTURE IF THE DRY VENT DOES NOT RUN UP | | | DIRECTLY INTO A WALL IT WILL BE EXPOSED ABOVE THE SLAB. | | | THIS COMMENT IS REFERRING TO THE DRY VENTS ON THE | | | CIRCUIT VENT FOR THE WC AND SH IN RM 114, 117, 122 | | | | | | NEW COMMENTS: | | | | | | 1. PROVIDE ISOMETRIC FOR STORM DRAIN. PER WPB AMEND TO | | | FBC 107.3.5.1.3(13) | | | | | | 2. SHOW THE SLOPE OF THE HORIZONTAL STORM PIPING. PER | | | FBC PL 1106.3 | | | | | | 3. THE UF FAUCET FOR THE PHYSICAL THERAPY TUB SHALL | | | HAVE A WATER TEMPERATURE LIMITING DEVISE PER FBC PL | | | 424.5 BATHTUB AND WHIRLPOOL BATHTUB VALVES. | | | THE HOT WATER SUPPLIED TO BATHTUBS AND WHIRLPOOL | | | BATHTUBS SHALL BE LIMITED TO A MAXIMUM TEMPERATURE OF | | | 120?F (49?C) BY A WATER-TEMPERATURE LIMITING DEVICE | | | THAT CONFORMS TO ASSE 1070 OR CSA B125.3, EXCEPT WHERE | | | SUCH PROTECTION IS OTHERWISE PROVIDED BY A COMBINATION | | | TUB/SHOWER VALVE IN ACCORDANCE WITH SECTION 424.3. | | | | | | 4. PLEASE PROVIDE MANUFACTURE SPEC AND INSTALLATION | | | GUIDE FOR LINT INTERCEPTOR. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | 5. PLEASE LABEL HOT RETURN AND COLD PIPING ALONG THE | | | RUN ON THE WATER ISOMETRIC. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-12-01 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-12-01 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-11-29 |
Time |
13:49 |
Sent To |
|
|
| Notes |
| 2017-11-29 13:50:18 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: TO EXPEDITE APPROVAL I SUGGEST A | | | MEETING TO GO OVER COMMENTS. | | | | | | 1. IN THE TITLE BLOCK ON THE PLAN IT SHOWS THE ADDRESS | | | AS 2600 MILITARY TRAIL, PER THE PERMIT THE ADDRESS | | | SHOULD BE 2331 NORTHWOOD UNIVERSITY DRIVE PLEASE | | | CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 2. SHT. A2.0 FOR THE PLUMBING FIXTURE COUNT IN THE | | | PUBLIC STADIUM BATHROOMS FOR THE REQUIRED WOMEN?S WC IT | | | SHALL BE 8. PER FBC PL TABLE 403.1 | | | | | | 3. SHT. A2.0 THE FAMILY BATHROOM CAN ONLY BE USED IN | | | THE FIXTURE COUNT FOR 1 SEX EITHER MEN?S OR WOMEN?S NOT | | | BOTH. PER FBC PL 403.1.2 | | | | | | 4. IN BATHROOMS 121 AND 118 A MIN OF ONE OF THE WC | | | STALLS SHALL BE AMBULATORY PER FBC ACC 213.3.1 AND | | | SHALL COMPLY WITH FBC ACC 604.8.2 | | | | | | 5. THE SINK IN THE REFRESHMENT TABLE SHALL COMPLY WITH | | | FBC ACC 606 PLEASE SHOW COMPLIANCE WITH FBC ACC 606.3 | | | | | | 6. SHT. A4.3 DETAILS J PLEASE CLARIFY THE DIMENSION OF | | | 3?-5?. PER WPB AMEND TO FBC 107.2.1 | | | | | | 7. PLEAS SHOW COMPLIANCE WITH FBC ACC | | | | | | A) 608.5.1 TRANSFER TYPE SHOWER COMPARTMENTS. | | | IN TRANSFER TYPE SHOWER COMPARTMENTS, THE CONTROLS, | | | FAUCETS, AND SHOWER SPRAY UNIT SHALL BE INSTALLED ON | | | THE SIDE WALL OPPOSITE THE SEAT 38 INCHES (965 MM) | | | MINIMUM AND 48 INCHES (1220 MM) MAXIMUM ABOVE THE | | | SHOWER FLOOR AND SHALL BE LOCATED ON THE CONTROL WALL | | | 15 INCHES (380 MM) MAXIMUM FROM THE CENTERLINE OF THE | | | SEAT TOWARD THE SHOWER OPENING. | | | | | | B) 608.5.3 ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENTS. | | | IN ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENTS, THE | | | CONTROLS, FAUCETS, AND SHOWER SPRAY UNIT SHALL BE | | | LOCATED ABOVE THE GRAB BAR, BUT NO HIGHER THAN 48 | | | INCHES (1220 MM) ABOVE THE SHOWER FLOOR. WHERE A SEAT | | | IS PROVIDED, THE CONTROLS, FAUCETS, AND SHOWER SPRAY | | | UNIT SHALL BE LOCATED ON THE SIDE WALL ADJACENT TO THE | | | SEAT 27 INCHES (685 MM) MAXIMUM FROM THE SIDE WALL | | | BEHIND THE SEAT OR SHALL BE LOCATED ON THE BACK WALL | | | OPPOSITE THE SEAT 15 INCHES (380 MM) MAXIMUM, LEFT OR | | | RIGHT, OF THE CENTERLINE OF THE SEAT. WHERE A SEAT IS | | | NOT PROVIDED, THE CONTROLS, FAUCETS, AND SHOWER SPRAY | | | UNIT SHALL BE INSTALLED ON THE SIDE WALL FARTHEST FROM | | | THE COMPARTMENT ENTRY. | | | | | | C) 608.2.1 TRANSFER TYPE SHOWER COMPARTMENTS. | | | TRANSFER TYPE SHOWER COMPARTMENTS SHALL BE 36 INCHES | | | (915 MM) BY 36 INCHES (915 MM) CLEAR INSIDE DIMENSIONS | | | MEASURED AT THE CENTER POINTS OF OPPOSING SIDES AND | | | SHALL HAVE A 36 INCH (915 MM) WIDE MINIMUM ENTRY ON THE | | | FACE OF THE SHOWER COMPARTMENT. CLEARANCE OF 36 INCHES | | | (915 MM) WIDE MINIMUM BY 48 INCHES (1220 MM) LONG | | | MINIMUM MEASURED FROM THE CONTROL WALL SHALL BE | | | PROVIDED. | | | | | | D) 608.2.3 ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENTS. | | | ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENTS SHALL BE 36 | | | INCHES (915 MM) WIDE AND 60 INCHES (1525 MM) DEEP | | | MINIMUM CLEAR INSIDE DIMENSIONS MEASURED AT CENTER | | | POINTS OF OPPOSING SIDES. A 36 INCH (915 MM) WIDE | | | MINIMUM ENTRY SHALL BE PROVIDED AT ONE END OF THE LONG | | | SIDE OF THE COMPARTMENT. | | | | | | E) 608.3.1 TRANSFER TYPE SHOWER COMPARTMENTS. | | | IN TRANSFER TYPE COMPARTMENTS, GRAB BARS SHALL BE | | | PROVIDED ACROSS THE CONTROL WALL AND BACK WALL TO A | | | POINT 18 INCHES (455 MM) FROM THE CONTROL WALL. | | | | | | F) 608.3.3 ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENTS. | | | IN ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENTS, GRAB | | | BARS SHALL BE PROVIDED ON THE BACK WALL AND THE SIDE | | | WALL FARTHEST FROM THE COMPARTMENT ENTRY. GRAB BARS | | | SHALL NOT BE PROVIDED ABOVE THE SEAT. GRAB BARS SHALL | | | BE INSTALLED 6 INCHES (150 MM) MAXIMUM FROM ADJACENT | | | WALLS. | | | | | | G) 610.3.2 L-SHAPED SEATS. | | | THE REAR EDGE OF AN L-SHAPED SEAT SHALL BE 21/2 INCHES | | | (64 MM) MAXIMUM AND THE FRONT EDGE 15 INCHES (380 MM) | | | MINIMUM AND 16 INCHES (405 MM) MAXIMUM FROM THE SEAT | | | WALL. THE REAR EDGE OF THE ?L? PORTION OF THE SEAT | | | SHALL BE 11/2 INCHES (38 MM) MAXIMUM FROM THE WALL AND | | | THE FRONT EDGE SHALL BE 14 INCHES (355 MM) MINIMUM AND | | | 15 INCHES (380 MM) MAXIMUM FROM THE WALL. THE END OF | | | THE ?L? SHALL BE 22 INCHES (560 MM) MINIMUM AND 23 | | | INCHES MAXIMUM (585 MM) FROM THE MAIN SEAT WALL. | | | | | | H) 610.3.1 RECTANGULAR SEATS. | | | THE REAR EDGE OF A RECTANGULAR SEAT SHALL BE 21/2 | | | INCHES (64 MM) MAXIMUM AND THE FRONT EDGE 15 INCHES | | | (380 MM) MINIMUM AND 16 INCHES (405 MM) MAXIMUM FROM | | | THE SEAT WALL. THE SIDE EDGE OF THE SEAT SHALL BE 11/2 | | | INCHES (38 MM) MAXIMUM FROM THE ADJACENT WALL. | | | | | | | | | 8. PLEASE PROVIDE A SCHEDULE FOR SHTS. A4.4, A4.5, A9.0 | | | LISTING THE LOCATIONS FROM THE LETTERS THAT THE DETAILS | | | ARE LABELED WITH. PER WPB AMEND TO FBC 107.2.1 | | | | | | 9. SHT. A4.6 DETAIL , TYPICAL ADA TOILET STALL THE | | | DIMENSION OF THE WC OFF SIDE WALL SHALL BE 16? MIN AND | | | 18? MAX, THE DIMENSION SHOWN 17?MIN 19?MAX IS FOR | | | AMBULATORY STALLS ONLY. PER FBC ACC 604.2 | | | | | | 10. SHT. A6.0 THE ROOF DRAIN CALCULATIONS SHOW AREA A | | | ONLY PLEASE SHOW THE REST OF THE ROOF. PER WPB AMEND TO | | | FBC 107.2.1 | | | | | | 11. SHT. P-2.2 SHOWS SQFT OF AREA A AS 3890 THE | | | CALCULATION ON SHT A6.0 LIST THE TOTALS AT 4092 PLEASE | | | CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 12. SHT. P2.2 PLEASE LABEL EMERGENCY SCUPPER DRAINS. | | | PER WPB AMEND TO FBC 107.2.1 | | | | | | 13. SHTS. P-2.3 AND WS-1 PLEASE PLACE NOTE ON PLAN. A | | | SEPARATE PERMIT WITH MANUFACTURE SPECIFICATIONS IS | | | REQUIRED FOR THE BACKFLOWS ON DOMESTIC WATER AND FIRE | | | LINE. PER WPB UTILITIES DEPT. | | | | | | 14. THE LAVATORY?S SHALL BE LIMITED TO TEMPERED WATER | | | ONLY, BY A TEMPERATURE LIMITING DEVISE THAT CONFORMS TO | | | ASSE 1070 THE TWO LEONARD MIXING VALVES LISTED IN THE | | | EQUIPMENT SCHEDULE, CONFORM TO ASSE 1017 ONLY. THE | | | WATTS LFUSG-B-M2 LISTED AS A TEMPERING VALVE UNDER THE | | | MISCELLANEOUS PLUMBING SCHEDULE COMPLIES WITH ASSE 1070 | | | AND FBC PL 416.5 PLEASE SHOW VALVES INSTALLED ON | | | ISOMETRIC DRAWING. PER WPB AMEND TO FBC 107.2.1 | | | | | | 15. PLEASE SHOW TRAP PRIMERS ON ALL FLOOR DRAINS ON THE | | | ISOMETRIC DRAWINGS. PER FBC PL 1002.4 | | | | | | 16. SHT. P-4 THE KITCHEN SINK IN THE STORAGE ROOM IS | | | LABELED HS ON THE ISOMETRIC DRAWING PLEASE CLARIFY. PER | | | WPB AMEND TO FBC 107.2.1 | | | | | | 17. THE FLOOR SINK FOR THE ICE MACHINE IS NOT VENTED IT | | | SHALL COMPLY WITH FBC PL 901.2.1 | | | | | | 18. PLEASE CLEARLY LABEL ICE MACHINE ON THE PLUMBING | | | FLOOR PLAN. PER WPB AMEND TO FBC 107.2.1 | | | | | | 19. A BACKFLOW IS REQUIRED ON WATER SUPPLY FOR THE ICE | | | MACHINE. PER FBC PL 608.3 | | | | | | 20. WHAT IS THE UF IN THE PHYSICAL THERAPY ROOM BEING | | | USED FOR PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 21. ALL DRY VENTS SHALL COMPLY WITH FBC PL | | | | | | A) 905.3 VENT CONNECTION TO DRAINAGE SYSTEM. | | | EVERY DRY VENT CONNECTING TO A HORIZONTAL DRAIN SHALL | | | CONNECT ABOVE THE CENTERLINE OF THE HORIZONTAL DRAIN | | | PIPE. | | | | | | B) 905.4 VERTICAL RISE OF VENT. | | | EVERY DRY VENT SHALL RISE VERTICALLY TO A POINT NOT | | | LESS THAN 6 INCHES (152 MM) ABOVE THE FLOOD LEVEL RIM | | | OF THE HIGHEST TRAP OR TRAPPED FIXTURE BEING VENTED. | | | | | | | | | 22. SHT. P-4 THE DRY VENT AT THE END OF THE BRANCH | | | DRAIN FOR THE FLOOR DRAINS IN THE WEIGHT ROOM, THE DRY | | | VENT AT THE END OF THE BRANCH DRAIN FOR PHYSICAL | | | THERAPY ROOM, THE DRY VENT AT THE END OF THE BRANCH | | | DRAIN FOR THE GANG SHOWERS AND THE DRY VENT IN THE | | | MIDDLE OF THE BRANCH DRAIN FOR THE GANG WC IN THE | | | WOMEN?S STADIUM BATHROOM DO NOT COMPLY WITH FBC PL | | | 905.3 AND 905.4 AND SHALL BE REMOVED FROM PLAN AND CODE | | | COMPLIANT DRY VENTS ADDED IN PROPER LOCATIONS. | | | | | | 23. THE CIRCUIT VENTS SHALL COMPLY WITH FBC PL | | | | | | A) 914.1 CIRCUIT VENT PERMITTED. | | | A MAXIMUM OF EIGHT FIXTURES CONNECTED TO A HORIZONTAL | | | BRANCH DRAIN SHALL BE PERMITTED TO BE CIRCUIT VENTED. | | | EACH FIXTURE DRAIN SHALL CONNECT HORIZONTALLY TO THE | | | HORIZONTAL BRANCH BEING CIRCUIT VENTED. THE HORIZONTAL | | | BRANCH DRAIN SHALL BE CLASSIFIED AS A VENT FROM THE | | | MOST DOWNSTREAM FIXTURE DRAIN CONNECTION TO THE MOST | | | UPSTREAM FIXTURE DRAIN CONNECTION TO THE HORIZONTAL | | | BRANCH. | | | | | | B) 914.1.1 MULTIPLE CIRCUIT-VENTED BRANCHES. | | | CIRCUIT-VENTED HORIZONTAL BRANCH DRAINS ARE PERMITTED | | | TO BE CONNECTED TOGETHER. EACH GROUP OF A MAXIMUM OF | | | EIGHT FIXTURES SHALL BE CONSIDERED A SEPARATE CIRCUIT | | | VENT AND SHALL CONFORM TO THE REQUIREMENTS OF THIS | | | SECTION. | | | | | | C) 914.2 VENT CONNECTION. | | | THE CIRCUIT VENT CONNECTION SHALL BE LOCATED BETWEEN | | | THE TWO MOST UPSTREAM FIXTURE DRAINS. THE VENT SHALL | | | CONNECT TO THE HORIZONTAL BRANCH AND SHALL BE INSTALLED | | | IN ACCORDANCE WITH SECTION 905. THE CIRCUIT VENT PIPE | | | SHALL NOT RECEIVE THE DISCHARGE OF ANY SOIL OR WASTE. | | | | | | 1) THE CIRCUIT VENT FOR THE GANG SHOWERS SHALL HAVE A | | | DRY VENT LOCATED BETWEEN THE 1ST AND 2ND MOST UPSTREAM | | | SHOWERS AND 5TH AND 6TH SHOWERS. | | | 2) THE CIRCUIT VENT FOR THE GANG WC IN THE STUDENT | | | ATHLETE BATHROOMS SHALL HAVE A DRY VENT LOCATED BETWEEN | | | THE 1ST AND 2ND WC AND THE 5TH AND 6TH WC. | | | 3) THE CIRCUIT VENT FOR THE GANG WC IN THE WOMEN?S | | | STADIUM BATHROOM SHALL HAVE A DRY VENT LOCATED BETWEEN | | | THE 1ST AND 2ND MOST UPSTREAM WC. | | | | | | 24. THE WC IN THE WOMEN?S STADIUM BATHROOM ACROSS FROM | | | THE ACCESSIBLE STALL IS NOT VENTED PROPERLY IT SHALL | | | COMPLY WITH FBC PL | | | | | | A) 901.2 TRAP SEAL PROTECTION. | | | THE PLUMBING SYSTEM SHALL BE PROVIDED WITH A SYSTEM OF | | | VENT PIPING THAT WILL PERMIT THE ADMISSION OR EMISSION | | | OF AIR SO THAT THE SEAL OF ANY FIXTURE TRAP SHALL NOT | | | BE SUBJECTED TO A PNEUMATIC PRESSURE DIFFERENTIAL OF | | | MORE THAN 1 INCH OF WATER COLUMN (249 PA). | | | B) 901.2.1 VENTING REQUIRED. | | | TRAPS AND TRAPPED FIXTURES SHALL BE VENTED IN | | | ACCORDANCE WITH ONE OF THE VENTING METHODS SPECIFIED IN | | | THIS CHAPTER. | | | | | | | | | 25. A WATER-HAMMER ARRESTOR IS REQUIRED ON THE ICE | | | MACHINE AND THE WATER FOUNTAINS. PER FBC PL 604.9 | | | | | | 26. THE WATER SUPPLY FOR THE WATER FOUNTAIN LOCATED | | | OUTSIDE STADIUM BATHROOMS IS MISSING FROM THE ISOMETRIC | | | DRAWING PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 27. SHUT OFF VALVES ARE REQUIRED AT THE HOSE BIBS | | | PLEASE SHOW ON WATER ISOMETRIC DRAWING. PER FBC PL | | | 606.2(2) | | | | | | 28. SHUT OFF VALVES ARE REQUIRED ON THE DROPS TO THE | | | SHOWER VALVES. PER FBC PL 606.1(5) | | | | | | 29. SHT. P-2.3 WHAT IS THE B+G CIRCUIT SETTER W/BALL | | | VALVE SHOWN ON THE WATER FLOOR PLAN PLEASE CLARIFY. PER | | | WPB AMEND TO FBC 107.2.1 | | | | | | 30. PLEASE SIZE THE WATER STUB OUTS ON THE ISOMETRIC | | | DRAWING FOR THE WC + UR. PER WPB AMEND TO FBC 107.2.1 | | | | | | 31. A LINT TRAP IS REQUIRED FOR THE WASHING MACHINE | | | DRAIN. PER FBC PL 1003.6 LAUNDRIES. | | | LAUNDRY FACILITIES NOT INSTALLED WITHIN AN INDIVIDUAL | | | DWELLING UNIT OR INTENDED FOR INDIVIDUAL FAMILY USE | | | SHALL BE EQUIPPED WITH AN INTERCEPTOR WITH A WIRE | | | BASKET OR SIMILAR DEVICE, REMOVABLE FOR CLEANING, THAT | | | PREVENTS PASSAGE INTO THE DRAINAGE SYSTEM OF SOLIDS 1/2 | | | INCH (12.7 MM) OR LARGER IN SIZE, STRING, RAGS, BUTTONS | | | OR OTHER MATERIALS DETRIMENTAL TO THE PUBLIC SEWAGE | | | SYSTEM. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
3 |
Status |
P |
Date |
2018-02-01 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-02-01 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-02-01 |
Time |
11:51 |
Sent To |
|
|
| Notes |
| 2018-02-01 14:13:46 | ****PROVISO**** | | | | | | ART LANGE BUILDING PLANS EXAMINER | | | | | | DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FL 33402 | | | 561-805-6718 [email protected] | | | FBC FLORIDA BUILDING CODE 2015 5TH EDITION W/2010 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | PERMIT NO. 17110003 | | | | | | SUBMIT RESIDENT INSPECTOR AGREEMENT WITH THE FOLLOWING | | | SUPPORTING DOCUMENTS FOR REVIEW | | | | | | SEE PAGE 3 OF THE GUIDLINES AND POLICIES FOR PROJECTS | | | CONCERNING THRESHOLD/ SPECIAL INSPECTORS AND RESIDENT | | | INSPECTORS | | | 1. COMPLETE THE RESIDENT INSPECTOR AGREEMENT IN FULL | | | AND RETURN THREE ORIGINALS COMPLETED TO THE DEVELOPMENT | | | SERVICES DEPARTMENT OF THE CITY OF WEST PALM BEACH. | | | | | | 3. ALL RESIDENT INSPECTORS ARE REQUIRED TO SUBMIT A | | | RESUME OF INSPECTION EXPERIENCE ON PREVIOUS PROJECTS. | | | THE RESUME MUST BE ACCOMPANIED BY ALL CERTIFICATES AS | | | SPECIFIED HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE | | | WILL REVIEW THE RESUME. AFTER THE RESUME IS REVIEWED, | | | AN INTERVIEW APPOINTMENT WILL BE SCHEDULED IF DEEMED | | | NECESSARY. | | | UNDER NO CIRCUMSTANCES WILL AN INSPECTOR BE INTERVIEWED | | | FOR WORK WITHOUT FIRST MEETING THE ABOVE CRITERIA. | | | THE INSPECTOR CLASSIFICATION FOR THIS PROJECT IS | | | RESIDENT INSPECTOR. SEE PAGES 14, 15 AND 16. THEY HAVE | | | NOT BEEN COMPLETED. | | | | | | |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
2 |
Status |
F |
Date |
2018-01-29 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-01-29 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-01-29 |
Time |
09:58 |
Sent To |
|
|
| Notes |
| 2018-01-29 10:09:31 | ****PLAN REVIEW COMMENTS**** | | | | | | ART LANGE BUILDING PLANS EXAMINER | | | | | | DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FL 33402 | | | | | | 561-805-6718 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2015 5TH EDITION W/2010 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | PERMIT NO. 17110003 | | | | | | RESIDENT INSPECTOR, SECOND REVIEW: | | | | | | SEE PAGE 3 OF THE GUIDLINES AND POLICIES FOR PROJECTS | | | CONCERNING THRESHOLD/ SPECIAL INSPECTORS AND RESIDENT | | | INSPECTORS | | | | | | 1. COMPLETE THE RESIDENT INSPECTOR AGREEMENT IN FULL | | | AND RETURN THREE ORIGINALS COMPLETED TO THE DEVELOPMENT | | | SERVICES DEPARTMENT OF THE CITY OF WEST PALM BEACH. | | | | | | 3. ALL RESIDENT INSPECTORS ARE REQUIRED TO SUBMIT A | | | RESUME OF INSPECTION EXPERIENCE ON PREVIOUS PROJECTS. | | | THE RESUME MUST BE ACCOMPANIED BY ALL CERTIFICATES AS | | | SPECIFIED HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE | | | WILL REVIEW THE RESUME. AFTER THE RESUME IS REVIEWED, | | | AN INTERVIEW APPOINTMENT WILL BE SCHEDULED IF DEEMED | | | NECESSARY. | | | | | | UNDER NO CIRCUMSTANCES WILL AN INSPECTOR BE INTERVIEWED | | | FOR WORK WITHOUT FIRST MEETING THE ABOVE CRITERIA. | | | | | | | | | THE INSPECTOR CLASSIFICATION FOR THIS PROJECT IS | | | RESIDENT INSPECTOR. SEE PAGES 14, 15 AND 16. THEY HAVE | | | NOT BEEN COMPLETED. | | | | | | |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
1 |
Status |
F |
Date |
2018-01-18 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-01-18 |
Time |
07:45 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-01-17 |
Time |
16:19 |
Sent To |
|
|
| Notes |
| 2018-01-18 07:45:18 | ****PLAN REVIEW COMMENTS**** | | | | | | ART LANGE BUILDING PLANS EXAMINER | | | | | | DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FL 33402 | | | | | | 561-805-6718 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2015 5TH EDITION W/2010 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | PERMIT NO. 17110003 | | | | | | RECEIVED A COPY OF THE SPECIAL INSPECTOR AGREEMENT VIA | | | EMAIL. | | | | | | 1. THE ADDRESS ON THE APPLICATION IS NOT THE CORRECT | | | JOB ADDRESS AND SHOULD BE SHOWN AS 2331 NORTHWOOD | | | UNIVERSITY DR. | | | | | | 2. THE FORMS USED ARE AN OLDER VERSION. I HAVE EMAILED | | | RAY RUIZ THE SPECIAL INSPECTOR AGREEMENT PDF FILE. | | | | | | 3. SUBMIT THREE COPIES OF THIS AGREEMENT ONCE YOU HAVE | | | IT UPDATED. | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
N |
Date |
2018-01-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-01-19 |
Time |
17:53 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-01-19 |
Time |
17:53 |
Sent To |
|
|
| Notes |
| 2018-01-19 17:54:46 | ****ISSUED AT APPLICANT'S RISK**** | | | | | | ZONING REVIEW DEFERRED | | | | | | 1) PRIOR TO FINAL ZONING APPROVAL OF THIS PERMIT, THE | | | MAJOR PLANNED DEVELOPMENT AMENDMENT TO ALLOW A STADIUM | | | AT KEISER UNIVERSITY MUST BE APPROVED BY THE CITY | | | COMMISSION. | | | | | | 2) THE LANDSCAPE AND SITE LIGHTING REQUIRE SEPARATE | | | PERMITS. PLEASE REMOVE THESE PLANS FROM THIS PERMIT. | | | | | | 3) ADDITIONAL SEPARATE PERMITS ARE REQUIRED FOR: | | | | | | A. PARKING | | | B. BICYCLE RACK | | | C. BLEACHERS | | | D. HARDSCAPE | | | E. DUMPSTER ENCLOSURE | | | F. FENCES/GATES | | | G. ASTROTURF FIELD | | | | | | PER ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2018-01-19 |
|
|
Cont ID |
|
| Sent By |
ES |
Date |
2018-01-19 |
Time |
17:03 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2018-01-19 |
Time |
17:03 |
Sent To |
|
|
| Notes |
| 2018-01-19 17:03:57 | FAILED | | | | | | 1) PRIOR TO FINAL ZONING APPROVAL OF THIS PERMIT, THE | | | MAJOR PLANNED DEVELOPMENT AMENDMENT TO ALLOW A STADIUM | | | AT KEISER UNIVERSITY MUST BE APPROVED BY THE CITY | | | COMMISSION. | | | | | | 2) THE LANDSCAPE AND SITE LIGHTING REQUIRE SEPARATE | | | PERMITS. PLEASE REMOVE THESE PLANS FROM THIS PERMIT. | | | | | | 3) ADDITIONAL SEPARATE PERMITS ARE REQUIRED FOR: | | | | | | A. PARKING | | | B. BICYCLE RACK | | | C. BLEACHERS | | | D. HARDSCAPE | | | E. DUMPSTER ENCLOSURE | | | F. FENCES/GATES | | | G. ASTROTURF FIELD | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2017-12-15 |
|
|
Cont ID |
|
| Sent By |
ES |
Date |
2017-12-15 |
Time |
10:29 |
Rev Time |
1.00 |
| Received By |
eschneid |
Date |
2017-12-14 |
Time |
15:51 |
Sent To |
|
|
| Notes |
| 2017-12-15 10:34:40 | FAILED | | | | | | 1) PRIOR TO FINAL ZONING APPROVAL OF THIS PERMIT, THE | | | MAJOR PLANNED DEVELOPMENT AMENDMENT TO ALLOW A STADIUM | | | AT KEISER UNIVERSITY MUST BE APPROVED BY THE CITY | | | COMMISSION. | | | | | | 2) PROVIDE CROSS SECTION DRAWINGS TO VERIFY THAT THE | | | PROPOSED ROOFTOP MECHANICAL EQUIPMENT IS SCREENED BY | | | THE PARAPETS. | | | | | | 3) THE LANDSCAPE AND SITE LIGHTING REQUIRE SEPARATE | | | PERMITS. PLEASE REMOVE THESE PLANS FROM THIS PERMIT. | | | | | | 4) ADDITIONAL SEPARATE PERMITS ARE REQUIRED FOR: | | | | | | A. PARKING | | | B. BICYCLE RACK | | | C. BLEACHERS | | | D. HARDSCAPE | | | E. DUMPSTER ENCLOSURE | | | F. FENCES/GATES | | | G. ASTROTURF FIELD | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] | | | |
|
|
|