Plan Review Details - Permit 17101162
| Plan Review Stops For Permit 17101162 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2018-04-12 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-04-12 |
Time |
12:28 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-04-12 |
Time |
12:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2018-04-05 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-04-05 |
Time |
07:38 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-04-05 |
Time |
07:17 |
Sent To |
|
|
| Notes |
| 2018-04-05 07:38:34 | ****PLAN REVIEW COMMENTS**** | | | | | | ART LANGE BUILDING PLANS EXAMINER | | | | | | DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FL 33402 | | | | | | 561-805-6718 [email protected] | | | | | | | | | FBC FLORIDA BUILDING CODE 2017 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION / FRC FLORIDA RESIDENTIAL CODE | | | 2017 6TH EDITION | | | | | | 1. ONE SET OF PLANS IS COMPLETED. THE SECOND SET IS | | | MISSING ARCHITECT'S SIGNATURES AND SEALS ON THE | | | FOLLOWING PAGES. | | | | | | IC1.0, IC1.1, LS1.1, A1.1, A6.1, A8.1, A9.0 AND A9.1. | | | | | | 61G1-16.004 TITLE BLOCK. | | | A TITLE BLOCK MUST APPEAR ON ALL ARCHITECTURAL OR | | | INTERIOR DESIGN DRAWINGS AND SPECIFICATION | | | IDENTIFICATION SHEETS THAT ARE REQUIRED TO BE SIGNED | | | AND SEALED. | | | | | | | | | | | | | | | WHEN RESUBMITTING, PLEASE COMPLETE A RESUBMITTAL FORM: | | | | | | HTTP://WPB.ORG/DEVELOPMENT/WPCONTENT/UPLOADS/SITES/33/2 | | | 013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | THIS FORM IS ALSO AVAILABLE AT THE BUILDING DIVISION. | | | | | | WHEN RESUBMITTING, SWAP OUT SHEETS WHICH HAVE CHANGED | | | SO THAT THERE ARE TWO COMPLETE, COLLATED SETS OF PLANS | | | READY FOR PERMIT ISSUANCE. OLD SHEETS ARE TO BE | | | RETAINED IN THE PERMIT APPLICATION PACKAGE (SEPARATE | | | FROM THE PERMIT SETS) AND MARKED *OLD SHEETS* OR | | | *VOID*. PLEASE KEEP BOTH SETS OF OLD VOIDED SHEETS IN | | | THE PERMIT PACKAGE. | | | | | | A RESPONSE LETTER INDICATING HOW EACH ITEM WAS | | | ADDRESSED WILL HELP TO EXPEDITE PLAN REVIEW. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2018-03-23 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-03-23 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-03-23 |
Time |
15:20 |
Sent To |
|
|
| Notes |
| 2018-03-23 16:20:07 | ****PLAN REVIEW COMMENTS**** | | | | | | ART LANGE - BUILDING INSPECTOR | | | 561-805-6667 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2014 5TH EDITION | | | | | | THIRD REVIEW: | | | | | | REPEATED COMMENT FROM LAST REVIEW AND ADDITIONAL | | | COMMENTS REGARDING THE COLLATING THE PLANS. | | | | | | A. TWO COMPLETE SETS OF PLANS NOT PROVIDED. | | | | | | B. PAGES NOT IN INDEX. AD 1.1, E 2.2, P 1.1 | | | | | | C. BOTH SETS HAVE DUPLICATED ELECTRICAL PAGES. | | | | | | D. BOTH SETS HAVE DUPLICATED MECHANICAL PAGES. | | | | | | E. ONE SET MISSING A 6.1, A 8.1, A 9.0 AND A 9.1 | | | | | | F. PAGE E 3.1 NOT PROVED BOTH SETS. | | | | | | G. PUT TOGETHER TWO COMPLETE SETS OF PLANS FOR REVIEW. | | | ADD THE MISSING PAGES TO THE INDEX. ORGANIZE THE PAGES | | | IN THE ORDER OF THE INDEX. | | | | | | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | | UPON SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS ARE | | | PERMITTED TO BE SUBMITTED WHERE APPROVED BY THE | | | BUILDING OFFICIAL. CONSTRUCTION DOCUMENTS SHALL BE OF | | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL. | | | | | | FBC 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | | | | | 4X FEES PLAN REVIEW FEE | | | | | | F.S. 553.80 (2) (B) | | | | | | (B)?WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS? | | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | | | | | | | PREVIOUS COMMENTS: | | | | | | COMPLETE SETS OF PLANS NOT PROVIDED. | | | ONLY ONE SET OF THE FOLLOWING PAGES FOUND. | | | IC1.0, IC1.1, LS 1.1, A1.1, A6.1, A8.1, A9.0 AND A9.1 | | | | | | SUBMIT A MINIMUM OF TWO SETS OF PLANS FOR REVIEW. FBC | | | 107.1 | | | | | | | | | WHEN RESUBMITTING, PLEASE COMPLETE A RESUBMITTAL FORM: | | | | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | THIS FORM IS ALSO AVAILABLE AT THE BUILDING DIVISION. | | | | | | WHEN RESUBMITTING, SWAP OUT SHEETS WHICH HAVE CHANGED | | | SO THAT THERE ARE TWO COMPLETE, COLLATED SETS OF PLANS | | | READY FOR PERMIT ISSUANCE. OLD SHEETS ARE TO BE | | | RETAINED IN THE PERMIT APPLICATION PACKAGE (SEPARATE | | | FROM THE PERMIT SETS) AND MARKED *OLD SHEETS* OR | | | *VOID*. PLEASE KEEP BOTH SETS OF OLD VOIDED SHEETS IN | | | THE PERMIT PACKAGE. | | | | | | A RESPONSE LETTER INDICATING HOW EACH ITEM WAS | | | ADDRESSED WILL HELP TO EXPEDITE PLAN REVIEW. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-02-22 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-02-22 |
Time |
10:05 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-02-22 |
Time |
08:45 |
Sent To |
P |
|
| Notes |
| 2018-02-22 10:02:14 | ****PLAN REVIEW COMMENTS**** | | | | | | ART LANGE - BUILDING INSPECTOR | | | 561-805-6667 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2014 5TH EDITION | | | | | | SECOND REVIEW: | | | | | | PREVIOUS COMMENTS ADDRESSED. | | | | | | NEW COMMENT: | | | | | | COMPLETE SETS OF PLANS NOT PROVIDED. | | | ONLY ONE SET OF THE FOLLOWING PAGES FOUND. | | | IC1.0, IC1.1, LS 1.1, A1.1, A6.1, A8.1, A9.0 AND A9.1 | | | | | | SUBMIT A MINIMUM OF TWO SETS OF PLANS FOR REVIEW. FBC | | | 107.1 | | | | | | | | | WHEN RESUBMITTING, PLEASE COMPLETE A RESUBMITTAL FORM: | | | | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | THIS FORM IS ALSO AVAILABLE AT THE BUILDING DIVISION. | | | | | | WHEN RESUBMITTING, SWAP OUT SHEETS WHICH HAVE CHANGED | | | SO THAT THERE ARE TWO COMPLETE, COLLATED SETS OF PLANS | | | READY FOR PERMIT ISSUANCE. OLD SHEETS ARE TO BE | | | RETAINED IN THE PERMIT APPLICATION PACKAGE (SEPARATE | | | FROM THE PERMIT SETS) AND MARKED *OLD SHEETS* OR | | | *VOID*. PLEASE KEEP BOTH SETS OF OLD VOIDED SHEETS IN | | | THE PERMIT PACKAGE. | | | | | | A RESPONSE LETTER INDICATING HOW EACH ITEM WAS | | | ADDRESSED WILL HELP TO EXPEDITE PLAN REVIEW. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-10-31 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2017-10-31 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2017-10-31 |
Time |
08:05 |
Sent To |
|
|
| Notes |
| 2017-10-31 10:44:23 | ****PLAN REVIEW COMMENTS**** | | | | | | ART LANGE - BUILDING INSPECTOR | | | 561-805-6667 [email protected] | | | FBC FLORIDA BUILDING CODE 2014 5TH EDITION/ FRC FLORIDA | | | RESIDENTIAL CODE 2015 5TH EDITION | | | | | | 1. PERMIT VALUE HAS BEEN REVISED TO INCLUDE ALL SUB | | | CONTRACTORS . IT NOW IS $201,800. | | | | | | 2. INCLUDED IN THE BUILDING DATA IS THE LEVEL OF | | | ALTERATION AS "REPAIRS". SEE EXISTING BUILDING CODE | | | SECTIONS 503 AND 504 FOR LEVEL 1 AND 2 ALTERATIONS. | | | SHOW HOW COMPLIANCE WITH THE SELECTED LEVEL OF | | | ALTERATION WILL BE SELECTED. | | | | | | 3. A) A1.1 LEGEND NOTE, NEW WALL SEE A.0.3 FOR | | | PARTITION DETAILS. PAGE A0.3 NOT PROVIDED WITH THESE | | | PLANS. | | | B) A1.1 LEGEND NOTE, SEE A7.1 FOR DOOR SCHEDULE. PAGE | | | A7.1 NOT PROVIDED WITH THESE PLANS. | | | | | | 4. PROVIDE AN EVALUATION REPORT FOR THE CLOSED CELL | | | INSULATION USED. SHOW HOW THIS PRODUCT WILL BE IN | | | COMPLIANCE IN TYPE I CONSTRUCTION FBC 2603.5 AND FBC | | | 2605.1. ALSO FOR FLAME SPREAD AND SMOKE-DEVELOPED | | | INDEXES. FBC 2605.5.4. | | | | | | | | | WHEN RESUBMITTING, PLEASE COMPLETE A RESUBMITTAL FORM: | | | | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | THIS FORM IS ALSO AVAILABLE AT THE BUILDING DIVISION. | | | WHEN RESUBMITTING, SWAP OUT SHEETS WHICH HAVE CHANGED | | | SO THAT THERE ARE TWO COMPLETE, COLLATED SETS OF PLANS | | | READY FOR PERMIT ISSUANCE. OLD SHEETS ARE TO BE | | | RETAINED IN THE PERMIT APPLICATION PACKAGE (SEPARATE | | | FROM THE PERMIT SETS) AND MARKED *OLD SHEETS* OR | | | *VOID*. PLEASE KEEP BOTH SETS OF OLD VOIDED SHEETS IN | | | THE PERMIT PACKAGE. | | | A RESPONSE LETTER INDICATING HOW EACH ITEM WAS | | | ADDRESSED WILL HELP TO EXPEDITE PLAN REVIEW. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2018-04-09 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-04-09 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-04-09 |
Time |
10:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-02-22 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-02-22 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-02-22 |
Time |
15:48 |
Sent To |
|
|
| Notes |
| 2018-02-22 15:47:57 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. ONLY ONE SET OF CORRECTED PLANS PROVIDED, PROVIDE 2 | | | COMPLETE SETS. FBC 107.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-12-04 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-12-04 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-12-04 |
Time |
09:57 |
Sent To |
|
|
| Notes |
| 2017-12-04 10:09:17 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. ON SHEET E2.1, THERE IS A BLOCK NOTE REFERENCING THE | | | 2017 FBC ENERGY CONSERVATION. THIS PERMIT APPLICATION | | | WAS SUBMITTED PRIOR TO THE EFFECTIVE DATE OF THAT CODE | | | AND THAT CODE WILL NOT BE USED FOR THIS PROJECT. | | | THEREFORE, PROVIDE DETAILS OF ALL EXISTING LIGHTING | | | CONTROLS. PROVIDE THE ADDITIONAL LIGHTING CONTROLS | | | STIPULATED IN THE ENERGY CONSERVATION CODE. IF NOT TO | | | CURRENT CODE, SHOW AS NEW INSTALLATIONS. FBC EC | | | 405.2.2; FBC 2014 PREFACE. | | | 2. PROVIDE GRAPH/CALCULATION OF INTERIOR LIGHTING POWER | | | ALLOWANCES PER THE FBC ENERGY CODE IN RELATION TO THE | | | CONNECTED INTERIOR LIGHTING PROPOSED TO COMPLY WITH | | | CODE. FBC EC 405.5 | | | 3. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 215.5, 408.4 | | | 4. BE ADVISED THAT FIRE ALARM, LOW VOLTAGE SYSTEMS, | | | LIGHTNING PROTECTION, GENERATORS, COMMERCIAL HOOD | | | SYSTEMS, SIGNS, SITE LIGHTING, AND SWIMMING POOLS | | | (WHERE APPLICABLE) ARE NOT INCLUDED IN THE SCOPE OF | | | THIS PLAN REVIEW. PROVIDE A BLOCK NOTE INDICATING THE | | | REQUIRED SEPARATE PERMITS AND DATA SPECIFICATION SHEET | | | SUBMITTALS FOR ANY OF THESE SYSTEMS PRESENT. FBC 105.1, | | | 107.2.1 | | | 5. THERE IS NO POWER PLAN INCLUDED IN THIS PLAN. THE | | | SCOPE OF WORK STATES THAT WORK WILL BE COMPLETED ON | | | WALLS THAT ARE DAMAGED, BUT DOES NOT EXPLAIN ANY | | | ELECTRICAL IN THESE WALLS TO BE REPAIRED. PROVIDE | | | DETAILS OF ANY ELECTRICAL IN WALLS TO BE REPAIRED, | | | NOTING COMPLIANCE WITH NEC 517.13 WHERE APPLICABLE. FBC | | | 107.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2018-04-12 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-04-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-04-12 |
Time |
12:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
F |
Date |
2018-04-10 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-04-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-04-09 |
Time |
16:17 |
Sent To |
|
|
| Notes |
| 2018-04-10 12:34:08 | 3RD RESPONSE | | | | | | | | | THESE PLANS CONTINUE TO BE UNORGANIZED. | | | | | | PREVIOUS COMMENTS: | | | | | | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) THE SUBMITTED PLANS ARE NOT ORGANIZED IN ANYWAY OR | | | REASONABLE FASHION THAT CAN BE DETERMINED AS A SET. | | | | | | THE SHEETS ARE NOT IN ANY KIND OF ORDER. THE SHEETS ARE | | | NOT STAPLED OR SEPARATED SO NO SETS CAN BE DEFINED FROM | | | ONE OR THE OTHER OR EVEN THREE. | | | | | | THERE IS ONE SET THAT IS STAPLED WITH A FIRE STAMP ON | | | IT BUT IT MAY A VOIDED SET. THIS SHEET MAY HAVE BEEN | | | PASSED BY FIRE WITH A PROVISO BUT ALL OTHER DEPARTMENTS | | | FAILED IT. | | | | | | | | | 2) PLEASE REVIEW AND MAKE COMPLETE ORGANIZED SETS | | | SEPARATED FROM EACH OTHER. PLACE VOID ON ANY SHEETS OR | | | SETS ACCORDINGLY. | | | | | | | | | ADDITIONAL COMMENTS: | | | | | | | | | 3) SHEET A0.0 ON ONE SET HAS CLOUD REVISIONS, ON THE | | | OTHER SET IT IS THE ORIGINAL WITH NO REVISION CLOUDS | | | AND AN OLD FIRE PREVENTION STAMP. | | | | | | 4) SHEET M2.1 ON ONE SET HAS NEW CLOUD REVISIONS AND | | | NEW ENGINEER STAMP, ON THE OTHER SET IT HAS OLD | | | REVISION CLOUDS, AN OLD DATED ENGINEER STAMP. | | | | | | 5) SHEET M2.2 ON ONE SET HAS NEW CLOUD REVISIONS AND | | | NEW ENGINEER STAMP, ON THE OTHER SET IT HAS OLD | | | REVISION CLOUDS, AN OLD DATED ENGINEER STAMP. | | | | | | 6) SHEET E0.1 ON ONE SET HAS NEW CLOUD REVISIONS AND | | | NEW ENGINEER STAMP, ON THE OTHER SET IT HAS OLD | | | REVISION CLOUDS, AN OLD DATED ENGINEER STAMP. | | | | | | 7) SHEET E1.1 ON ONE SET HAS NEW CLOUD REVISIONS AND | | | NEW ENGINEER STAMP, ON THE OTHER SET IT HAS OLD | | | REVISION CLOUDS, AN OLD DATED ENGINEER STAMP. | | | | | | 8) SHEET E2.1 ON ONE SET HAS NEW CLOUD REVISIONS AND | | | NEW ENGINEER STAMP, ON THE OTHER SET IT HAS OLD | | | REVISION CLOUDS, AN OLD DATED ENGINEER STAMP. | | | | | | PLEASE ENSURE THAT EACH PAGE OF THE SUBMITTED SETS ARE | | | EQUAL AND REFLECT THE CURRENT STATE OF UPDATED | | | DRAWINGS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2018-03-20 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-03-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-03-20 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2018-03-20 11:48:24 | 2ND RESPONSE | | | | | | THE PREVIOUS COMMENTS WERE NOT ADDRESSED. | | | | | | THSES PLANS CONTINUE TO BE UNORGANIZED. | | | | | | PREVIOUS COMMENTS: | | | | | | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) THE SUBMITTED PLANS ARE NOT ORGANIZED IN ANYWAY OR | | | RESONABLE FASHION THAT CAN BE DETERMINED AS A SET. | | | | | | THE SHEETS ARE NOT IN ANY KIND OF ORDER. THE SHEETS ARE | | | NOT STAPLED OR SEPARATED SO NO SETS CAN BE DEFINED FROM | | | ONE OR THE OTHER OR EVEN THREE. | | | | | | THERE IS ONE SET THAT IS STAPLED WITH A FIRE STAMP ON | | | IT BUT IT MAY A VOIDED SET. THIS SHEET MAY HAVE BEEN | | | PASSED BY FIRE WITH A PROVISO BUT ALL OTHER DEPARTMENTS | | | FAILED IT. | | | | | | | | | 2) PLEASE REVIEW AND MAKE COMPLETE ORGANIZED SETS | | | SEPARATED FROM EACH OTHER. PLACE VOID ON ANY SHEETS OR | | | SETS ACCORDINGLY. | | | | | | | | | ADDITIONAL COMMENTS: | | | | | | | | | 3) THERE IS ONLY 1 LIFE SAFETY SHEET, BUT TWO APPARENT | | | SETS | | | | | | 4) THERE ARE ONLY 1 IC 1 & IC 1.1 SHEETS, BUT TWO | | | APPARENT SETS. | | | | | | 5) WITH THE TWO SETS, IF YOU WERE TO TURN EACH SET ONE | | | AT A TIME, THEY DO NOT MATCH. | | | | | | 6) A LIFE SAFETY REVIEW CAN NOT BE COMPLETED BECAUSE I | | | DO NOT KNOW WHAT SHEETS ARE SUPPOSED TO COMPRISE A SET | | | AND WHAT MAY OR MAY NOT BE MSSING. | | | | | | 7) PLEASE CORRECT AND ENSURE THE SETS MATCH. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2018-02-01 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-02-01 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-02-01 |
Time |
11:47 |
Sent To |
|
|
| Notes |
| 2018-02-01 13:41:12 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) THE SUBMITTED PLANS ARE NOT ORGANIZED IN ANYWAY OR | | | RESONABLE FASHION THAT CAN BE DETERMINED AS A SET. | | | | | | THE SHEETS ARE NOT IN ANY KIND OF ORDER. THE SHEETS ARE | | | STAPLED OR SEPARATED SO NOT SETS CAN BE DEFINED FROM | | | ONE OR THE OTHER OR EVEN THREE. | | | | | | THERE IS ONE SET THAT IS STAPLED WITH A FIRE STAMP ON | | | IT BUT IT MAY A VOIDED SET. THIS SHEET MAY HAVE BEEN | | | PASSED BY FIRE WITH A PROVISO BUT ALL OTHER DEPARTMENTS | | | FAILED IT. | | | | | | | | | 2) PLEASE REVIEW AND MAKE COMPLETE ORGANIZED SETS | | | SEPARATED FROM EACH OTHER. PLACE VOID ON ANY SHEETS OR | | | SETS ACCORDINGLY. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2017-11-02 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2017-11-02 |
Time |
12:50 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2017-11-02 |
Time |
12:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-04-12 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2018-04-12 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2018-03-16 |
Time |
14:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-02-28 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-02-28 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-02-28 |
Time |
15:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-12-04 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2017-12-04 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2017-10-27 |
Time |
14:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2018-04-12 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-04-12 |
Time |
12:28 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-04-12 |
Time |
12:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2018-02-20 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-02-20 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-02-20 |
Time |
10:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-11-18 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-11-18 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-11-18 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2017-11-18 12:17:41 | 1ST REVIEW FBC-2014 MECHANICAL CODE, GUIDELINES FOR | | | DESIGN AND CONSTRUCTION OF HEALTH CARE FACILITIES-2010 | | | PERMIT #17101162 | | | 11/18/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET M3.1: PROVIDE THE CURRENT CODE OR STANDARD | | | USED TO ESTABLISH THE VENTILATION REQUIREMENTS AND | | | PRESSURE RELATIONSHIPS SHOWN IN THE AIR SUMMARY TABLE. | | | | | | 2) M2.1, M2.2, & M3.1: PLEASE LABEL THE DRESSING ROOMS | | | T140A & T140B ON THE PLANS. PLEASE NOTE THAT EXHAUST | | | VENTILATION SYSTEMS ARE REQUIRED FOR THE DRESSING ROOMS | | | AND LOCKER ROOM PER TABLE 403.3 FBC-14. | | | | | | 3) M3.1: PLEASE CLARIFY WHY EXHAUST VENTILATION IS | | | PROVIDED FOR X-RAY ROOMS 2 & 3 BUT NOT FOR X-RAY 1, AND | | | THE SAME FOR WAITING ROOM T1070 BUT NOT FOR ANY OF THE | | | OTHER WAITING ROOMS. | | | | | | 4) PROVIDE A SUBMITTAL FOR THE NEW DUCT INSULATION WITH | | | APPROVAL SIGNATURE BY THE DEWIGN PROFESSIONAL OF | | | RECORD. THE PRODUCT DATA SHALL INDICATE THE MATERIAL IS | | | LISTED AND LABELED AS HAVING A FLAME SPREAD OF NOT MORE | | | THAN 25 AND SMOKE-DEVELOPED INDEX OF NOT MORE THAN 50 | | | WHEN TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723- | | | SECTION 602.2.1 MATERIALS WITHIN PLENUMS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2018-04-11 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-04-11 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-04-11 |
Time |
09:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2018-02-28 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-02-28 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-02-28 |
Time |
15:26 |
Sent To |
|
|
| Notes |
| 2018-02-28 15:32:56 | 2ND REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: PREVIOUS COMMENT NOT COMPLIED | | | | | | 2ND REQUEST1. PROVIDE PLUMBING PLAN THE CLEARLY SHOWS | | | THE SCOPE OF ALL PLUMBING WORK TO BE DONE. PER WPB | | | AMEND TO FBC 107.2.1 | | | | | | 2. SHT AD1.1 KEY NOTE #7 REMOVE SINK AND TOILET SHT. | | | A1.1 DOES NOT LIST THE SINK AND TOILET THAT WAS REMOVED | | | ON SHT AD1.1 THE PLUMBING APPLICATION STATES MULTIPLE | | | MOP SINKS, SINKS AND WATER CLOSETS I DON'T SEE THAT ON | | | THE PLAN PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-11-29 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-11-29 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-11-29 |
Time |
13:51 |
Sent To |
|
|
| Notes |
| 2017-11-29 15:16:54 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. PROVIDE PLUMBING PLAN THE CLEARLY SHOWS THE SCOPE OF | | | ALL PLUMBING WORK TO BE DONE. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
|