| 2017-11-02 13:54:36 | 2014 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 17101145 |
| | ADD: 1601 FORUM PLACE SUITE: 1000 |
| | CONT: CHANDLER CONSTRUCTION |
| | TEL: 561-791-6934 |
| | E-MAIL: [email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: THURS. NOV. 02/ 2017 |
| | ACTION: DENIED |
| | |
| | 1) SHEET A-1 OFFICE 106 THE ENTRY DOOR DOES NOT COMPLY |
| | WITH THE 2014 FBC-ACCESSIBILITY CODE SECTION 404.2.4 |
| | MANEUVERING CLEARANCES AT DOORS. MUST HAVE 18 INCHES ON |
| | THE PULL LATCH SIDE WHEN THE DOOR. |
| | SEE FIGURE 404.2.4.1(A) FRONT APPROACH, PULL SIDE. |
| | |
| | 2) SHEET A-1 THE EXISTING CORRIDOR DOOR BETWEEN THE 2 |
| | HOUR STAIR WELL AND OFFICE 103 APPEARS TO ONLY HAVE 1 |
| | FOOT MANEUVERING CLEARANCE ON THE LATCH PULL SIDE OF |
| | THE DOOR. UNDER PERMIT 12100574 THE SAME DOOR WAS DRAWN |
| | TO 3/16TH INCH SCALE AND APPEARED TO BE A TIGHT 18 |
| | INCHES. PLEASE PROVIDE THE ACTUAL DIMENSION FOR |
| | MANEUVERING CLEARANCES. IF THE DOOR DOES NOT HAVE THE |
| | REQUIRED 18 INCHES THEN UNDER THE |
| | ACCESSIBILITY CODE SECTION 202.4.1 DISPROPORTIONATE |
| | COST UP TO 20% OF THE PERMIT VALUE ($8,400.00) CAN BE |
| | SPENT IN ORDER TO BRING THE TENANT SPACE UP TO THE |
| | PRESENT ACCESSIBILITY CODE. |
| | |
| | 202.4.1 DISPROPORTIONATE COST. |
| | ALTERATIONS MADE TO PROVIDE AN ACCESSIBLE PATH OF |
| | TRAVEL TO THE ALTERED AREA WILL BE DEEMED |
| | DISPROPORTIONATE TO THE OVERALL ALTERATION WHEN THE |
| | COST EXCEEDS 20% OF THE COST OF THE ALTERATION TO THE |
| | PRIMARY FUNCTION AREA. COSTS THAT MAY BE COUNTED AS |
| | EXPENDITURES REQUIRED TO PROVIDE AN ACCESSIBLE PATH OF |
| | TRAVEL MAY INCLUDE: (I) COSTS ASSOCIATED WITH PROVIDING |
| | AN ACCESSIBLE ENTRANCE AND AN ACCESSIBLE ROUTE TO THE |
| | ALTERED AREA; (II) COSTS ASSOCIATED WITH MAKING |
| | RESTROOMS ACCESSIBLE, SUCH AS INSTALLING GRAB BARS, |
| | ENLARGING TOILET STALLS, INSULATING PIPES, OR |
| | INSTALLING ACCESSIBLE FAUCET CONTROLS; (III) COSTS |
| | ASSOCIATED WITH PROVIDING ACCESSIBLE TELEPHONES, SUCH |
| | AS RELOCATING THE TELEPHONE TO AN ACCESSIBLE HEIGHT, |
| | INSTALLING AMPLIFICATION DEVICES, OR INSTALLING A TEXT |
| | TELEPHONE (TTY); (IV) COSTS ASSOCIATED WITH RELOCATING |
| | AN INACCESSIBLE DRINKING FOUNTAIN. |
| | |
| | 3) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | JAMES A. WITMER BN, PX, CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES |
| | DEPARTMENT |
| | 401 CLEMATIS ST. |
| | WEST PALM BEACH. FL 33402 |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |