Plan Review Details - Permit 17101137
| Plan Review Stops For Permit 17101137 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2017-11-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-11-14 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-11-14 |
Time |
09:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2017-11-06 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-11-06 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-11-06 |
Time |
16:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2017-10-31 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-10-31 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-10-31 |
Time |
11:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-12-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2017-12-06 |
Time |
12:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-11-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-11-14 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-10-27 |
Time |
13:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2017-12-19 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-12-19 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-12-12 |
Time |
08:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-11-03 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-11-03 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-11-03 |
Time |
12:28 |
Sent To |
|
|
| Notes |
| 2017-11-03 14:24:28 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #17101137 | | | PHILLIPS POINTE EAST TOWER | | | 11/3/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) M0.1: PROVIDE AN EQUIPMENT SCHEDULE FOR THE NEW | | | GREENHECK 48 MODEL RGU UPBLAST FAN, AND REFER TO 513 | | | SMOKE CONTROL SYSTEMS, AND SPECIFICALLY SECTIONS | | | 513.10, AND 513.10.5. VERIFY THAT THE NEW GREENHECK FAN | | | IS RATED AND CERTIFIED BY THE MANUFACTURER FOR THE | | | PROBABLE TEMPERATURE RISE, IS UL LISTED AS A POWER | | | VENTILATOR FOR SMOKE CONTROL, AND THAT IT IS EQUIPPED | | | WITH TWO BELTS (IF THE FAN IS BELT DRIVEN AND NOT | | | DIRECT-DRIVE) | | | | | | 2) SHEET M3.1) PROVIDE THE WIND LOAD DESIGN CRITERIA | | | PER SECTION 1609 FBC-14 BUILDING. | | | | | | 3) M4.1) THE SHEET TOO FAINT TO READ AND NOT LEGIBLE- | | | SECTION 107.1 WPB AMENDMENTS TO THE FBC. | | | | | | 4) VERIFY THE FAN IS BEING SUPPLIED WITH TWO SOURCES OF | | | POWER- PRIMARY FROM THE NORMAL BUILDING SYSTEM, AND | | | SECONDARY FROM AN APPROVED STANDBY SOURCE- SECTION | | | 513.11. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2017-11-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-11-14 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-11-14 |
Time |
09:19 |
Sent To |
|
|
| Notes |
| 2017-12-19 14:09:47 | MECH DIG/SIGS GOOD- CCOLE- 12/19/17 | | 2017-11-14 09:20:15 | DIGITAL SIGNATURES OK | | | PROVISO: NEW SHEETS SUBMITTED 2ND CYCLE REQUIRE REVIEW | | | |
|
|
|