Plan Review Details - Permit 17101037
Plan Review Stops For Permit 17101037
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-12-04 Cont ID  
Sent By cthroop Date 2017-12-04 Time 15:34 Rev Time 0.00
Received By cthroop Date 2017-12-04 Time 15:34 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-11-17 Cont ID  
Sent By cthroop Date 2017-11-17 Time 09:25 Rev Time 0.00
Received By cthroop Date 2017-11-16 Time 16:48 Sent To  
Notes
2017-11-17 09:35:34BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. ALTERATIONS TO EXISTING BUILDINGS SHALL COMPLY WITH
 THE FBC ACCESSIBILITY CODE PER SECTION 202.3, 220 AND
 CHPT. 7
 2. PROVIDE DETAILS OF ACCESSIBLE ROUTE FROM A PUBLIC
 WAY OR ACCESSIBLE PARKING PER 402.2
 3. PROVIDE DETAILS FOR ACCESSIBLE RAMP
 4. ATM'S SHALL COMPLY WITH SECTION 220
  
 202.3 ALTERATIONS.
 WHERE EXISTING ELEMENTS OR SPACES OR COMMON AREAS ARE
 ALTERED, EACH ALTERED ELEMENT, SPACE OR AREA SHALL
 COMPLY WITH THE APPLICABLE REQUIREMENTS OF CHAPTER 2
 AND SECTION 201.1.1. SEE SECTION 208.1 FOR EXISTING
 PARKING
  
 220 AUTOMATIC TELLER MACHINES AND FARE MACHINES
  
 220.1 GENERAL.
 WHERE AUTOMATIC TELLER MACHINES OR SELF-SERVICE FARE
 VENDING, COLLECTION, OR ADJUSTMENT MACHINES ARE
 PROVIDED, AT LEAST ONE OF EACH TYPE PROVIDED AT EACH
 LOCATION SHALL COMPLY WITH 707. WHERE BINS ARE PROVIDED
 FOR ENVELOPES, WASTE PAPER, OR OTHER PURPOSES, AT LEAST
 ONE OF EACH TYPE SHALL COMPLY WITH 811
  
 402.2 COMPONENTS.
 ACCESSIBLE ROUTES SHALL CONSIST OF ONE OR MORE OF THE
 FOLLOWING COMPONENTS: WALKING SURFACES WITH A RUNNING
 SLOPE NOT STEEPER THAN 1:20, DOORWAYS, RAMPS, CURB
 RAMPS EXCLUDING THE FLARED SIDES, ELEVATORS, AND
 PLATFORM LIFTS. ALL COMPONENTS OF AN ACCESSIBLE ROUTE
 SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF
 CHAPTER 4 AND 208.3.1.
  
  
 707.1 GENERAL.
 AUTOMATIC TELLER MACHINES AND FARE MACHINES SHALL
 COMPLY WITH 707
  
 ACCESSIBLE ROUTES SHALL COMPLY WITH 402.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED AND MARK VOID.
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-12-04 Cont ID  
Sent By cthroop Date 2017-12-04 Time 15:34 Rev Time 0.00
Received By cthroop Date 2017-11-22 Time 14:26 Sent To  
Notes
2017-11-22 14:26:43RESUB ROUTED TO KMARTIN VIA ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-11-17 Cont ID  
Sent By cthroop Date 2017-11-17 Time 09:35 Rev Time 0.00
Received By cthroop Date 2017-10-25 Time 09:57 Sent To I
Notes
2017-10-27 09:58:07ROUTED TO ZONING

Review Stop Z ZONING
Rev No 2 Status P Date 2017-12-04 Cont ID  
Sent By   Date 2017-12-04 Time   Rev Time 0.00
Received By kmartin Date 2017-12-04 Time 13:34 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2017-11-13 Cont ID  
Sent By KM Date 2017-11-13 Time   Rev Time 0.00
Received By kmartin Date 2017-11-13 Time 10:44 Sent To B
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy