Plan Review Details - Permit 17100958
| Plan Review Stops For Permit 17100958 |
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-11-15 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-11-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-11-14 |
Time |
13:53 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2017-10-26 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-10-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-10-25 |
Time |
16:49 |
Sent To |
M |
|
| Notes |
| 2017-10-26 12:34:31 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) THERE IS INSUFFICIENT DETAIL PROVIDED TO CONDUCT AN | | | ADAQUATE PLAN REVIEW. | | | | | | | | | 2) THE SUBMITTED PLAN DOES NOT INDICATE WHAT IS AN | | | EXISTING, RELOCATED, NEW OR REMOVED SPRINKLER HEAD. | | | | | | PLEASE PROVIDE DETAILS. | | | | | | | | | 3) THE SUBMITTED PLANS DO NOT INDICATE WHAT IS AND WHAT | | | SIZE IS AN EXISTING, RELOCATED, NEW OR REMOVED BRANCH | | | LINE PIPING. | | | | | | PLEASE PROVIDE DETAILS. | | | | | | | | | 4) SIDEWALL SPRINKLERS ARE INDICATED, ARE THESE | | | EXISTING AND/OR ARE THERE ANY OBSTRUCTIONS, INCLUDING | | | BUT NOT LIMITED TO, CEILING FANS AND/OR LIGHT FIXTURES | | | IN THESE ROOMS OR AREAS? | | | | | | PLEASE PROVIDE DETAILS. | | | | | | | | | 5) BASED ON ANY OF THE ABOVE, PLEASE INDICATE IF THE | | | EXISITNG HYDRALIC CALCULATIONS WILL BE AFFECTED AND IF | | | SO, PROVIDE REVISED CALCULATIONS. | | | | | | PLEASE PROVIDE DETAILS. | | | | | | | | | 6) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 7) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-11-15 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2017-11-15 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2017-11-13 |
Time |
15:02 |
Sent To |
|
|
| Notes |
| 2017-11-13 15:02:54 | RESUB ROUTED TO FIRE INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-11-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-11-08 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-10-24 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2017-10-25 10:37:12 | ROUTED TO FIRE INBOX |
|
|
|
Account Summary | Usage Policy | Privacy Policy