Plan Review Details - Permit 17100863
| Plan Review Stops For Permit 17100863 |
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-11-16 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-11-16 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-11-14 |
Time |
15:24 |
Sent To |
|
|
| Notes |
| 2017-11-14 15:25:06 | CCOLE'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-10-31 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-10-20 |
Time |
09:27 |
Sent To |
|
|
| Notes |
| 2017-10-23 09:28:11 | MECH <5K |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2017-11-16 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-11-16 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-11-16 |
Time |
11:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-10-31 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-10-31 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-10-31 |
Time |
15:02 |
Sent To |
|
|
| Notes |
| 2017-10-31 15:38:49 | 1ST REVIEW FBC-2014 RESIDENTIAL MECHANICAL | | | PERMIT #17100863 | | | 10/31/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE SUBMITTED AC DUCT LAYOUT PLAN IS NOT SUITABLE | | | FOR REVIEW. ALL PLANS SHALL BE DRAWN NEATLY AT A | | | MINIMUM 1/8" SCALE, AND SHALL BE OF SUFFICIENT CLARIFY | | | TO INDICATE THE EXTENT OF THE WORK PROPOSED AND SHOW IN | | | DETAIL THAT IT WILL CONFORM TO THE PROVISIONS OF THE | | | CODE- PLEASE REVIEW SECTIONS 107.2.1 AND 107.2.1.4 WPB | | | AMENDMENTS TO THE FBC. PLEASE MAKE THE FOLLOWING | | | CORRECTIONS. | | | | | | A) PROVIDE TWO SEPARATE FLOOR PLAN DRAWINGS- FIRST | | | FLOOR AND SECOND FLOOR. | | | B) SHOW THE ROOMS ON EACH FLOOR AND IDENTIFY THEM. | | | C) SHOW THE ACTUAL LOCATION OF THE EXISTING AIR | | | HANDLER- THE SUBMITTED DRAWING DOES NOT SHOW IT IN THE | | | HOUSE. | | | D) SHOW THE DIMENSIONS OF THE DIFFUSERS AND RETURN | | | GRILLS. | | | E) SHOW THE SUPPLY CFMS AT EACH DIFFUSER. | | | F) SHOW HOW AIR IS BEING RETURNED FROM THE BEDROOMS- | | | TRANSFER GRILLS, TRANSFER DUCTS? | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
|