Plan Review Details - Permit 17100851
Plan Review Stops For Permit 17100851
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2018-03-21 Cont ID  
Sent By jgomez Date 2018-03-21 Time 14:06 Rev Time 0.00
Received By jgomez Date 2018-03-21 Time 11:59 Sent To  
Notes
2018-03-21 12:12:51BUILDING REVIEW APPROVED WITH PROVISO:
 1- PROVIDE COMPLETE INSTALLATION SCHEDULE FOR THE
 HURRICANE FABRIC NOA 15-0316.09 SUBMITTED.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2018-03-12 Cont ID  
Sent By jgomez Date 2018-03-09 Time 18:10 Rev Time 0.00
Received By jgomez Date 2018-03-09 Time 15:26 Sent To  
Notes
2018-03-09 15:42:35RESIDENTIAL (R3) ADDITION/ALTERATION SECOND BUILDING
 REVIEW CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 NOTE:
 BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO
 MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER
 THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID
 CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR
 TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME
 OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT
 ISSUANCE.
  
 1- ENERGY CALCULATIONS SUBMITTED:
 NEW COMMENT:
 A) FORM R405-2017 SUBMITTED NOW IS INCORRECT. THIS FORM
 IS FOR THE 2017 CODE. THIS BUILDING IS BEING REVIEWED
 UNDER THE 2014 CODE. PROVIDE CORRECT FORM. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 B) ENERGY CALCULATIONS CALL FOR ELECTRIC WATER HEATER
 ON ITEM #14. PLANS CALL FOR GAS WATER HEATER. REVISE TO
 MATCH PLANS. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 C) WINDOW INFORMATION SHOWN ON PAGE 3 OF 4 OF FORM
 SUBMITTED; CLARIFY WHAT KIND OF FRAME IS "TIM". SEC.
 107.2.1 CITY AMENDMENTS. SEE PRODUCT APPROVALS
 SUBMITTED.
  
 D) THE NAME OF THE "BLOCKS" INFORMATION ON PAGE 2 OF 4
 SPECIFIES "ENTIRE HOUSE". ACCORDING TO AREA SHOWN ON
 PAGE ONE (414 S.F.) THIS BLOCK IS FOR THE ADDITION NOT
 FOR ENTIRE HOUSE. REVISE AS REQUIRED. SEC. R101.5.1.1.2
 FBC-ENERGY CONSERVATION.
  
 E) CLARIFY WHY THERE ARE NO OCCUPANTS ON THE MASTER
 BEDROOM. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 2- HURRICANE FABRIC NOA 15-0316.09 SUBMITTED: PROVIDE
 FLOOR PLAN SKETCH AND COMPLETE INSTALLATION SCHEDULE.
 SEE CITY SAMPLE FOR REQUIRED INFORMATION. INSTALLATION
 SCHEDULE SUBMITTED IS INCOMPLETE. NEED TO SPECIFY
 OPENING SIZES, LOCATION, ALL MOUNTING CONDITIONS,
 ANCHORS, SPACING, ETC. TO VERIFY COMPLIANCE WITH THE
 DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL.
  
 3- TRUSS PACKAGE SUBMITTED;
 A) ALL TRUSS DRAWINGS NEED THE TRUSS ENGINEER SEAL AND
 SIGNATURE AS REQUIRED BY CHAPTER 471 F.S.
  
 ****PLEASE PROVIDE RESPONSE LETTER CLEARLY ADDRESSING
 EACH COMMENT TO HELP EXPEDITE THE REVIEW PROCESS.
 ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWINGS. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD
 DRAWINGS FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-11-21 Cont ID  
Sent By jgomez Date 2017-11-21 Time 18:50 Rev Time 0.00
Received By jgomez Date 2017-11-21 Time 15:22 Sent To I
Notes
2017-11-15 18:29:12RESIDENTIAL (R3) ADDITION/ALTERATION BUILDING REVIEW
 COMMENTS.
 CODE: FBC 5TH EDITION (2014).
  
 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT.
 BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID
 RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF
 THE UNIFIED LAND DEVELOPMENT CODE.
 NOTE: THIS CAN BE DONE LATER AFTER THE PLANS ARE
 APPROVED AND STAMPED BY OUR OFFICE.
  
 2- AREA CALCULATIONS SHOWN ON SHEET C.1 DON'T MATCH
 AREA CALCULATIONS SHOWN ON SHEET 1.1 AND SHEET 2.1.
 REVISE AS REQUIRED TO MATCH. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 3- WINDOW ON BEDROOM #1 WAS BLOCKED TO ALLOW FOR THE
 MASTER BEDROOM ADDITION. SPECIFY TYPE AND SIZE OF
 WINDOW TO BE BLOCKED AND TYPE AND SIZE OF REMAINING
 WINDOW TO VERIFY COMPLIANCE WITH THE EGRESS
 REQUIREMENTS. SEC. 704 FBC-EXISTING BUILDING, 5TH
 EDITION (2014).
  
 4- TYPE OF FOOTING F-2 SHOWN ON FOUNDATION PLAN ON
 SHEET 2.1 DOESN'T MATCH FOOTING SHOWN ON TYPICAL WALL
 SECTION ON SHEET 5.1. VERIFY TYPE OF FOOTING AND SIZE
 TO MATCH. SEC. R301.1 FBC-RESIDENTIAL.
 NOTE: COORDINATE WITH ITEM #8(A) BELOW.
  
 5- IT IT'S NOT CLEAR HOW MANY RISERS ARE REQUIRED BY
 THE NEW EXTERIOR DOOR AT THE NEW MASTER BATHROOM AREA.
 FLOOR PLAN ON SHEET 2.1 SHOWS 2 RISERS, WHILE NORTH
 ELEVATION ON SHEET 4.1 SHOWS 3 RISERS. REVISE AS
 REQUIRED TO MATCH. ALSO, LANDING AT THE NEW EXTERIOR
 DOOR MAY BE REQUIRED. SEE SEC. R311.3.2 FBC-RESIDENTIAL
 AND REVISE AS REQUIRED.
  
 6- REVISE THE ALTERATION LEVEL SPECIFIED ON THE PROJECT
 DATA ON SHEET 2.1. ACCORDING TO SEC. 505 FBC-EXISTING
 BUILDING, 5TH EDITION (2014) AND SCOPE OF WORK SHOWN ON
 PLANS THIS IS ALTERATION LEVEL 3 NOT ALTERATION LEVEL
 2. REVISE AS REQUIRED.
  
 7- REVISE THE CORNER DISTANCE "A" SPECIFIED ON THE
 COMPONENT AND CLADDING PRESSURE ZONES TABLE ON SHEET
 4.1. ACCORDING TO FOOTNOTE OF FIGURE R301.2(7)
 FBC-RESIDENTIAL, THE LETTER "A" IS 4 FEET IN ALL CASES
 NOT 3 FEET. REVISE AS REQUIRED.
  
 8- SOIL TEST REPORT SUBMITTED:
 A) ARCHITECT OF RECORD TO REVIEW CONCLUSIONS ON THE
 SOIL TEST REPORT AND REVISE FOOTING DESIGN ACCORDINGLY
 OR ACKNOWLEDGE IN WRITING THAT DESIGNED FOOTINGS ARE
 ADEQUATE DESPITE THE SOIL TEST REPORT CONCLUSIONS. SEC.
 R301.1 FBC-RESIDENTIAL.
  
 B) PROVIDE 2 COPIES. ONLY ONE COPY WAS SUBMITTED. SEC.
 107.1 CITY AMENDMENTS.
  
 9- ENERGY CALCULATIONS SUBMITTED:
 A) OWNER OR LEGALLY DESIGNATED AGENT TO CERTIFY AND
 DATE THE BOTTOM OF FORM AS REQUIRED BY SEC. R103.1.1.2
 FBC-ENERGY CONSERVATION, 5TH EDITION (2014).
  
 B) PROVIDE COMPLETE INFORMATION ON TOP OF FORM,
 INCLUDING OWNER, BUILDER, PERMIT OFFICE. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 C) REVISE WINDOW FRAME MATERIAL SPECIFIED ON PAGE 4 OF
 5. WINDOWS AND DOORS PRODUCT APPROVALS SUBMITTED ARE
 FOR ALUMINUM WINDOWS AND DOORS NOT VINYL. REVISE AS
 REQUIRED. SEC. R103.2 FBC-ENERGY CONSERVATION.
  
 D) REVISE THE WINDOWS OVERHANG SEPARATION ON PAGE 4 OF
 5 TO MATCH PLANS. SEC. R101.5.1.1.2 FBC-ENERGY
 CONSERVATION.
  
 NOTE: LABEL FOR DOORS AND WINDOWS SHOWING THE U-FACTOR
 AND SHGC FACTOR SPECIFIED ON THE ENERGY CALCULATIONS
 WILL BE REQUIRED WHEN ENERGY CALCULATIONS ARE NOT USING
 THE DEFAULT FACTOR FOR GLAZING.
  
 10- PROVIDE MANUFACTURER'S SPECIFICATIONS FOR THE
 WINDOWS AND DOORS SHOWING COMPLIANCE WITH THE U-FACTOR
 AND SHGC FACTOR SPECIFIED ON THE ENERGY CALCULATIONS
 SUBMITTED. SEC. R405.4.3 FBC-ENERGY CONSERVATION.
  
 11- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20-3.001 FOR:
 A) SINGLE HUNG WINDOWS. NEED TO PROVIDE 2 COPIES. ONLY
 ONE COPY OF NOA 15-0512.10 WAS SUBMITTED. ALSO,
 DRAWINGS SUBMITTED ARE TOO SMALL. PLEASE PROVIDE COPY
 OF DRAWINGS THAT ARE PRINTED IN THE LANDSCAPE FORMAT.
 THIS WAY DRAWINGS ARE MORE LEGIBLE.
  
 B) FIXED WINDOWS. NEED TO PROVIDE 2 COPIES. ONLY ONE
 COPY OF NOA 15-0413.03 WAS SUBMITTED. ALSO, DRAWINGS
 SUBMITTED ARE TOO SMALL. PLEASE PROVIDE COPY OF
 DRAWINGS THAT ARE PRINTED IN THE LANDSCAPE FORMAT. THIS
 WAY DRAWINGS ARE MORE LEGIBLE.
  
 C) ALUMINUM OUTSWING GLAZED DOOR. NEED TO PROVIDE 2
 COPIES. ONLY ONE COPY OF NOA 14-1015.04 WAS SUBMITTED.
 ALSO, DRAWINGS SUBMITTED ARE TOO SMALL. PLEASE PROVIDE
 COPY OF DRAWINGS THAT ARE PRINTED IN THE LANDSCAPE
 FORMAT. THIS WAY DRAWINGS ARE MORE LEGIBLE.
  
 D) OVERHEAD GARAGE DOOR. NEED TO PROVIDE 2 COPIES. ONLY
 ONE COPY OF NOA 16-0330.02 WAS SUBMITTED. ALSO,
 DRAWINGS SUBMITTED ARE TOO SMALL. PLEASE PROVIDE COPY
 OF DRAWINGS THAT ARE PRINTED IN THE LANDSCAPE FORMAT.
 THIS WAY DRAWINGS ARE MORE LEGIBLE.
  
 E) HURRICANE FABRIC. NEED TO PROVIDE 2 COPIES. ONLY ONE
 COPY OF NOA 15-0316.09 WAS SUBMITTED.
 NOTE: NEED TO PROVIDE COMPLETE INSTALLATION SCHEDULE
 FOR THE INSTALLATION OF THE HURRICANE FABRIC. SEE CITY
 SAMPLE OF INSTALLATION SCHEDULE.
  
 F) PRECAST LINTELS AS SPECIFIED ON PLANS.
  
 12- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN
 WRITING (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS
 AS REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 ****PLEASE PROVIDE RESPONSE LETTER CLEARLY ADDRESSING
 EACH COMMENT TO HELP EXPEDITE THE REVIEW PROCESS.
 ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWINGS. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD
 DRAWINGS FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-03-09 Cont ID  
Sent By jleahy Date 2018-03-09 Time 13:16 Rev Time 0.00
Received By jleahy Date 2018-03-09 Time 13:16 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2017-11-14 Cont ID  
Sent By jleahy Date 2017-11-14 Time 08:55 Rev Time 0.00
Received By jleahy Date 2017-11-14 Time 08:55 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status P Date 2018-03-12 Cont ID  
Sent By gjohnson Date 2018-03-12 Time 15:49 Rev Time 0.00
Received By gjohnson Date 2018-03-12 Time 15:49 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2018-03-07 Cont ID  
Sent By fmittner Date 2018-03-07 Time 13:43 Rev Time 0.00
Received By fmittner Date 2018-03-07 Time 13:43 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2017-11-06 Cont ID  
Sent By fmittner Date 2017-11-06 Time 15:31 Rev Time 0.00
Received By fmittner Date 2017-11-06 Time 15:31 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2018-03-28 Cont ID  
Sent By jgomez Date 2018-03-28 Time 13:07 Rev Time 0.00
Received By jgomez Date 2018-03-23 Time 09:14 Sent To  
Notes
2018-03-26 09:14:58IMPACT FEES ROUTED TO JGOMEZ

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-03-21 Cont ID  
Sent By jgomez Date 2018-03-21 Time 14:26 Rev Time 0.00
Received By jgomez Date 2018-03-19 Time 13:14 Sent To I
Notes
2018-03-20 13:14:26RESUB ROUTED TO JGOMEZ

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-03-12 Cont ID  
Sent By gjohnson Date 2018-03-12 Time 15:49 Rev Time 0.00
Received By gjohnson Date 2018-02-09 Time 09:32 Sent To  
Notes
2018-02-13 09:32:55R31

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-11-22 Cont ID  
Sent By jgomez Date 2017-11-22 Time 14:34 Rev Time 0.00
Received By jgomez Date 2017-10-20 Time 11:23 Sent To I
Notes
2017-10-23 11:23:44R08

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 4 Status P Date 2018-03-28 Cont ID  
Sent By jgomez Date 2018-03-28 Time 13:06 Rev Time 0.00
Received By jgomez Date 2018-03-28 Time 12:57 Sent To  
Notes
2018-03-28 13:07:00$180.65 PAID. MU-2018-006252

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status F Date 2018-03-21 Cont ID  
Sent By jgomez Date 2018-03-21 Time 14:26 Rev Time 0.00
Received By jgomez Date 2018-03-21 Time 14:26 Sent To  
Notes
2018-03-21 14:26:47BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.
  
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2018-03-09 Cont ID  
Sent By jgomez Date 2018-03-09 Time 15:52 Rev Time 0.00
Received By jgomez Date 2018-03-09 Time 15:51 Sent To  
Notes
2018-03-09 15:53:04BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.
  
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2017-11-16 Cont ID  
Sent By jgomez Date 2017-11-16 Time 07:53 Rev Time 0.00
Received By jgomez Date 2017-11-16 Time 07:51 Sent To  
Notes
2017-11-16 07:53:54 
 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT.
 BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID
 RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF
 THE UNIFIED LAND DEVELOPMENT CODE.
 NOTE: THIS CAN BE DONE LATER AFTER THE PLANS ARE
 APPROVED AND STAMPED BY OUR OFFICE.
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2018-03-21 Cont ID  
Sent By jgomez Date 2018-03-21 Time 14:20 Rev Time 0.00
Received By jgomez Date 2018-03-21 Time 14:20 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2018-03-12 Cont ID  
Sent By jgomez Date 2018-03-12 Time 08:36 Rev Time 0.00
Received By jgomez Date 2018-03-12 Time 08:36 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-11-22 Cont ID  
Sent By jgomez Date 2017-11-22 Time 14:10 Rev Time 0.00
Received By jgomez Date 2017-11-22 Time 13:40 Sent To I
Notes
2017-11-22 14:32:45RESIDENTIAL (R3) ADDITION/ALTERATION MECHANICAL REVIEW
 COMMENTS.
 CODE: FBC 5TH EDITION (2014).
  
 1- RETURN AIR TRANSFER DUCT SIZE SPECIFIED FOR THE
 MASTER BEDROOM DOESN'T COMPLY WITH SEC. M1602.4
 FBC-RESIDENTIAL, 5TH EDITION (2014). NEED AT LEAST 15"
 DIAMETER TRANSFER DUCT. REVISE A/C PLAN AS REQUIRED.
 NOTE: DUCT SIZE IS BASED ON ALL THE SUPPLY AIR TO THE
 MASTER BEDROOM, INCLUDING BATHROOM AND CLOSETS.
  
 2- IT LOOKS LIKE THE SAME PERSON DOING THE ENERGY
 CALCULATIONS IS DOING THE EQUIPMENT SIZING
 CALCULATIONS. ENERGY CALCULATIONS NEED TO BE REVISED.
 SEE BUILDING REVIEW COMMENTS. REVISE THE EQUIPMENT
 SIZING CALCULATIONS BASED ON THE REVISED ENERGY
 CALCULATIONS. SEC. R403.6 FBC-ENERGY CONSERVATION, 5TH
 EDITION (2014).
  
 3- A/C PLAN TO LIST THE EQUIPMENT LISTED IN THE
 EQUIPMENT SIZING CALCULATIONS. SEC. R403.6 FBC-ENERGY
 CONSERVATION AND SEC. 107.3.5.3(10) CITY AMENDMENTS.
  
  
 ****PLEASE PROVIDE RESPONSE LETTER CLEARLY ADDRESSING
 EACH COMMENT TO HELP EXPEDITE THE REVIEW PROCESS.
 ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWINGS. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD
 DRAWINGS FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop P PLUMBING
Rev No 3 Status P Date 2018-03-21 Cont ID  
Sent By jgomez Date 2018-03-21 Time 14:16 Rev Time 0.00
Received By jgomez Date 2018-03-21 Time 14:16 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2018-03-12 Cont ID  
Sent By jgomez Date 2018-03-12 Time 09:06 Rev Time 0.00
Received By jgomez Date 2018-03-12 Time 09:06 Sent To  
Notes
2018-03-12 09:07:13PLUMBING REVIEW APPROVED WITH PROVISO:
 1- ENERGY CALCULATIONS CALL FOR ELECTRIC WATER HEATER.
 PLANS CALL FOR GAS WATER HEATER. REVISE AS REQUIRED TO
 MATCH.

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-11-15 Cont ID  
Sent By gjohnson Date 2017-11-15 Time 16:38 Rev Time 0.00
Received By gjohnson Date 2017-11-15 Time 11:14 Sent To  
Notes
2017-11-15 16:46:591ST REVIEW: FBC 2014 5TH EDITION
  
 PLUMBING COMMENTS:
  
 1. THE ENERGY CALCULATIONS SHOW A ELECTRIC TANKLESS
 WATER HEATER THE PLANS SHOW IT ON THE EXTERIOR OF
 BUILDING, NORMALLY ELECTRIC TANKLESS HEATERS ON NOT
 DESIGNED FOR EXTERIOR INSTALLATIONS THE ELECTRIC PANEL
 SHOWS 30 AMP BREAKERS FOR THE WATER HEATER MOST
 TANKLESS ARE 40 AMP AND ABOVE PLEASE PROVIDE
 MANUFACTURE SPECIFICATIONS TO CLARIFY. PER WPB AMEND TO
 FBC 107.2.1
  
 2. SHOW LOCATION OF EXISTING WATER HEATER. PER WPB
 AMEND TO FBC 107.2.1
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2018-03-09 Cont ID  
Sent By jgomez Date 2018-03-09 Time 18:43 Rev Time 0.00
Received By jgomez Date 2018-03-09 Time 18:36 Sent To  
Notes
2018-03-09 18:37:031) SHINGLES NOA 16-1109.18.
 2- UNDERLAYMENT NOA 15-1123.06

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2017-11-22 Cont ID  
Sent By jgomez Date 2017-11-22 Time 13:42 Rev Time 0.00
Received By jgomez Date 2017-11-22 Time 13:41 Sent To  
Notes
2017-11-22 13:43:441) SHINGLES NOA 16-1109.18.
 2- UNDERLAYMENT NOA 15-1123.06

Review Stop Z ZONING
Rev No 2 Status P Date 2018-03-07 Cont ID  
Sent By fmittner Date 2018-03-07 Time 13:43 Rev Time 0.00
Received By fmittner Date 2018-03-07 Time 13:43 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2017-11-06 Cont ID  
Sent By fmittner Date 2017-11-06 Time 15:31 Rev Time 0.00
Received By fmittner Date 2017-11-06 Time 15:31 Sent To  
Notes
***NONE***