Plan Review Details - Permit 17100809
Plan Review Stops For Permit 17100809
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2018-09-04 Cont ID  
Sent By cthroop Date 2018-09-04 Time 12:03 Rev Time 0.00
Received By cthroop Date 2018-09-04 Time 11:28 Sent To I
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2018-07-05 Cont ID  
Sent By cthroop Date 2018-07-05 Time 11:59 Rev Time 0.00
Received By cthroop Date 2018-07-05 Time 11:25 Sent To  
Notes
2018-07-05 12:43:24BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 2ND REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE MANUFACTURERS INSTALLATION INSTRUCTIONS. IF
 INSTALLATION INSTRUCTIONS DO NOT HAVE A FOUNDATION
 DETAIL THEN A FOUNDATION DESIGN SHALL BE PROVIDED BY A
 REGISTERED DESIGN PROFESSIONAL.
 FBC 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS.
 THE EXAMINATION OF THE DOCUMENTS BY THE BUILDING
 OFFICIAL SHALL INCLUDE THE FOLLOWING MINIMUM CRITERIA
 AND DOCUMENTS: A FLOOR PLAN; SITE PLAN; FOUNDATION
 PLAN; FLOOR/ROOF FRAMING PLAN OR TRUSS LAYOUT; ALL
 FENESTRATION PENETRATIONS; FLASHING; AND ROUGH OPENING
 DIMENSIONS; AND ALL EXTERIOR ELEVATIONS:
  
  
 2. PROVIDE THE FOLLOWING INFORMATION FOR THE SHADE
 STRUCTURE -
 2A. DESIGN WIND LOADS.
 FBC 107.3.5.1.1(8) ? PROVIDE WIND DESIGN LOADS/DESIGN
 PRESSURES PURSUANT TO FBC-CHAPTER 16
  
 1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE
 STRUCTURE:
 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST),
 MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED,
 VASD, AS DETERMINED IN ACCORDANCE WITH SECTION
 1609.3.1.
 2. RISK CATEGORY.
 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE
 THAN ONE WIND EXPOSURE IS UTILIZED.
 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT.
 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY
 DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL
 RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/
 M2).
  
 2B. FLAME SPREAD TEST REPORT FOR THE COVERING PER NFPA
 701 AND/OR ASTM E-84.
 FBC 603.1 FLAME SPREAD ? ASTM E-84-09
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED AND MARK VOID.
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-10-27 Cont ID  
Sent By aclange Date 2017-10-27 Time 14:17 Rev Time 0.00
Received By aclange Date 2017-10-27 Time 14:17 Sent To  
Notes
2017-10-27 14:19:37****PLAN REVIEW COMMENTS****
  
 ART LANGE - BUILDING INSPECTOR
 561-805-6667 [email protected]
 FBC FLORIDA BUILDING CODE 2014 5TH EDITION/ FRC FLORIDA
 RESIDENTIAL CODE 2015 5TH EDITION
  
 1. INSUFFICIENT INFORMATION SUBMITTED FOR PLAN REVIEW.
 SUBMIT PLANS SHOWING THE LOCATIONS AND TYPE OF WORK TO
 BE COMPLETED. PROVIDE DETAILS FOR ACCESSIBLEROUTE,RAMP
 AND STRUCTURAL DETAILS. PLAYGROUND EQUIPMENT
 SPECIFICATIONS NOT PROVIDED. INCLUDE THE EQUIPMENT USED
 AND METHOD OF ANCHORING. WILL FENCING BE INCLUDED WITH
 THIS PROJECT? FBC 107.3.5 MINIMUM PLAN REVIEW CRITERIA.
  
 2. PERSON RESPONSIBLE FOR THE DESIGN SHALL SIGN ALL
 DRAWINGS AND SUBMITTALS.
  
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN
 UPON SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS
 SHALL BE SUBMITTED WHEN APPROVED BY THE BUILDING
 OFFICIAL. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT
 CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF
 THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL
 CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT
 LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED
 BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND
 SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM
 OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS,
 WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE
 TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC,
 AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE
 OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS
 EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION. ALL INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO
 SECTION 107.3.5).
  
 3. CONTRACTOR REQUIRED BEFORE ISSUING THIS PERMIT FS
 489
  
 WHEN RESUBMITTING, PLEASE COMPLETE A RESUBMITTAL FORM:
  
 HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/
 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF
  
 THIS FORM IS ALSO AVAILABLE AT THE BUILDING DIVISION.
 WHEN RESUBMITTING, SWAP OUT SHEETS WHICH HAVE CHANGED
 SO THAT THERE ARE TWO COMPLETE, COLLATED SETS OF PLANS
 READY FOR PERMIT ISSUANCE. OLD SHEETS ARE TO BE
 RETAINED IN THE PERMIT APPLICATION PACKAGE (SEPARATE
 FROM THE PERMIT SETS) AND MARKED *OLD SHEETS* OR
 *VOID*. PLEASE KEEP BOTH SETS OF OLD VOIDED SHEETS IN
 THE PERMIT PACKAGE.
 A RESPONSE LETTER INDICATING HOW EACH ITEM WAS
 ADDRESSED WILL HELP TO EXPEDITE PLAN REVIEW.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-09-04 Cont ID  
Sent By cthroop Date 2018-09-04 Time 12:03 Rev Time 0.00
Received By cthroop Date 2018-08-27 Time 12:41 Sent To  
Notes
2018-08-29 12:42:07RESUB ROUTED TO CTHROOP

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-07-05 Cont ID  
Sent By cthroop Date 2018-07-05 Time 12:43 Rev Time 0.00
Received By cthroop Date 2018-06-20 Time 11:48 Sent To I
Notes
2018-06-21 11:48:52RESUB ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-10-27 Cont ID  
Sent By aclange Date 2017-10-27 Time 14:20 Rev Time 0.00
Received By aclange Date 2017-10-19 Time 13:04 Sent To  
Notes
2017-10-20 13:04:53ROUTED TO ZONING

Review Stop Z ZONING
Rev No 2 Status P Date 2018-07-03 Cont ID  
Sent By llouie Date 2018-07-03 Time   Rev Time 0.00
Received By llouie Date 2018-07-03 Time   Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2017-10-25 Cont ID  
Sent By LL Date 2017-10-25 Time   Rev Time 0.00
Received By llouie Date 2017-10-24 Time 14:53 Sent To B
Notes
2017-10-25 10:36:08** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 1.) UPDATED SURVEY OF THE PROPERTY REQUIRED. PLEASE
 PROVIDE.
  
 2.) THE PROPOSED TOT LOT IS LOCATED NEXT TO THE
 EXISTING PARKING LOT. A PROTECTIVE BARRIER (I.E. FENCE)
 AROUND THE TOT LOT IS REQUIRED FOR SAFETY. INCLUDE
 DETAILS OF THE PROPOSED BARRIER.
  
 3.) TOT LOT EQUIPMENT DETAILS/SPECIFICATIONS MISSING
 FROM THE PERMIT PACKAGE. PLEASE PROVIDE.
  
  
 NOTES:
  
 * REVISIONS MAY RESULT IN ADDITIONAL COMMENT.
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.
  
 * Z = MF32
  