Plan Review Details - Permit 17100796
| Plan Review Stops For Permit 17100796 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2017-11-03 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-11-03 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-11-03 |
Time |
14:57 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2017-11-03 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-11-03 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-11-03 |
Time |
10:02 |
Sent To |
|
|
| Notes |
| 2017-11-03 10:05:59 | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED | | | NFPA 70 2011 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | | | | RISER DIAGRAM NOW SHOWS NO FEED TO MAIN? | | | | | | PLAN STILL SHOWS PANEL "E" PAGE E101 | | | | | | JUST CURIOUS WHAT IS A LIGHNTING WARNING PANEL? IS IT | | | LISTED? |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-10-25 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-10-25 |
Time |
12:26 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-10-25 |
Time |
12:26 |
Sent To |
|
|
| Notes |
| 2017-10-25 13:03:58 | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED | | | NFPA 70 2011 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | RISER DIAGRAM IS ONCOMPLETE PAGE E101 | | | | | | PLAN SHOWS 5 PANELS SCHEDULES BUT ONLY 4 PANELS SHOWN | | | ON DRAWINGS. | | | | | | PLANS SHOWS GENERATOR, WHICH IS NOT SHOWN ON RISER | | | DIAGRAM. SEPARATE PERMIT REQUIRED | | | | | | RISER SHOWS 2 CONDUITS FROM METER TO MAIN BUT NO WIRE | | | SIZES, SAME FROM MAIN TO GUTTER. | | | | | | FAULT CURRENT IS SHOWN AT 22,000 HOW WAS THIS | | | CALCULATED. | | | | | | PLAN SHOWS SEVERAL OUTLETS THAT ARE OUT SIDE AND NOT | | | GFCI PROTECTED | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-11-03 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-11-03 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-11-03 |
Time |
07:29 |
Sent To |
|
|
| Notes |
| 2017-11-03 07:30:04 | 11/3 TO JAKE LEAHY DESK | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-10-25 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-10-25 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-10-19 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2017-10-20 11:00:24 | ROUTED TO ELECTRICAL INBOX |
|
|
|