Plan Review Details - Permit 17100594
Plan Review Stops For Permit 17100594
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2017-11-21 Cont ID  
Sent By cthroop Date 2017-11-21 Time 15:14 Rev Time 0.00
Received By cthroop Date 2017-11-21 Time 15:14 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2017-11-17 Cont ID  
Sent By cthroop Date 2017-11-17 Time 10:40 Rev Time 0.00
Received By cthroop Date 2017-11-17 Time 10:18 Sent To  
Notes
2017-11-17 10:48:06BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 2ND REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE DESIGN WIND LOADS FOR PROPOSED ROOF DECK.
 2. PROVIDE FASTENER SCHEDULE FOR ROOF DECK.
 3. METAL ROOF PANELS SHALL BE INSTALLED PER FBCR905.10.
 4. PROVIDE FLORIDA PRODUCT APPROVALS FOR METAL ROOF
 PANELS.
 5. PROVIDE SITE PLAN - SHOW SET BACKS TO PROPERTY LINES
 AND OTHER STRUCTURES ON SITE.
  
 FBC 107.3.5.3 - PROVIDE WIND DESIGN LOADS/DESIGN
 PRESSURES PURSUANT TO FBC-R301.2.
  
 R301.2.1 WIND DESIGN CRITERIA.
 BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN
 ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING
 THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED
 FROM FIGURE R301.2(4). THE STRUCTURAL PROVISIONS OF
 THIS CODE FOR WIND LOADS ARE NOT PERMITTED WHERE WIND
 DESIGN IS REQUIRED AS SPECIFIED IN SECTION R301.2.1.1.
 WHERE DIFFERENT CONSTRUCTION METHODS AND STRUCTURAL
 MATERIALS ARE USED FOR VARIOUS PORTIONS OF A BUILDING,
 THE APPLICABLE REQUIREMENTS OF THIS SECTION FOR EACH
 PORTION SHALL APPLY. WHERE NOT OTHERWISE SPECIFIED, THE
 WIND LOADS LISTED IN TABLE R301.2(2) ADJUSTED FOR
 HEIGHT AND EXPOSURE USING TABLE R301.2(3) SHALL BE USED
 TO DETERMINE DESIGN LOAD PERFORMANCE REQUIREMENTS FOR
 WALL COVERINGS, CURTAIN WALLS, ROOF COVERINGS, EXTERIOR
 WINDOWS, SKYLIGHTS AND EXTERIOR DOORS (OTHER THAN
 GARAGE DOORS).
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN
 UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE
 OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT
 IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 R905.10 METAL ROOF PANELS.
 THE INSTALLATION OF METAL ROOF PANELS SHALL COMPLY WITH
 THE PROVISIONS OF THIS SECTION.
  
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING SUBMITTALS.
  
 FBC 107.3.5.3 ? PROVIDE A SITE PLAN TO DEMONSTRATE
 SETBACKS AND BUILDING SEPARATION.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED AND MARK VOID.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-10-23 Cont ID  
Sent By cthroop Date 2017-10-23 Time 10:25 Rev Time 0.00
Received By cthroop Date 2017-10-23 Time 10:09 Sent To  
Notes
2017-10-23 10:34:50BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 DUE TO THE DEFICIENCIES OF THIS PLAN, A COMPLETE AND
 THOROUGH REVIEW CANNOT BE PERFORMED AT THIS TIME. UPON
 RE-SUBMITTAL, ADDITIONAL COMMENTS MAY BE MADE.
  
 1. FOR A PRE-ENGINEERED SHED, PROVIDE THE FOLLOWING:
 1A. PROVIDE FOUNDATION PLAN.
 1B. PROVIDE PRE-ENGINEERED DESIGN.
 1C. IDENTIFY TYPE OF TIE-DOWN TO FOUNDATION.
 1D. PROVIDE SITE PLAN WITH LOCATION OF PROPOSED SHED.
  
 2. FOR A SITE BUILT SHED, PROVIDE THE FOLLOWING:
 2A. PROVIDE FOUNDATION PLAN ? FOOTINGS/SLAB ON
 GRADE/RE-INFORCING
 2B. PROVIDE BUILDING PLANS TO INCLUDE -
 2C. FLOOR DESIGN
 2D. WALL DESIGN
 2E. ROOF FRAMING - DETAIL FASTENER SCHEDULE AND ROOF TO
 WALL CONNECTION.
 3. WINDOW AND/OR DOOR SCHEDULE WITH ROUGH OPENINGS AND
 DESIGN WIND LOADS.
 4. PRODUCT APPROVALS FOR ALL ROOFING, WINDOWS AND/OR
 DOORS.
 5. PROVIDE SITE PLAN WITH SETBACKS FROM PROPERTY LINES.
  
 THE INDIVIDUAL TAKING RESPONSIBILITY SHALL PROVIDE
 THEIR PRINTED NAME AND SIGNATURE ON THE SUBMITTED PLANS
 AND SUPPORTING DOCUMENTS PER FBC 107.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-11-17 Cont ID  
Sent By cthroop Date 2017-11-17 Time 10:48 Rev Time 0.00
Received By cthroop Date 2017-11-13 Time 12:38 Sent To I
Notes
2017-11-13 12:38:34RESUB ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-10-23 Cont ID  
Sent By cthroop Date 2017-10-23 Time 10:25 Rev Time 0.00
Received By cthroop Date 2017-10-16 Time 09:20 Sent To  
Notes
2017-10-17 09:21:09ROUTED TO ZONING

Review Stop Z ZONING
Rev No 2 Status P Date   Cont ID  
Sent By PG Date 2017-11-16 Time   Rev Time 0.00
Received By ajones Date 2017-11-14 Time 12:03 Sent To B
Notes
2017-11-16 14:42:23 
  
  
 PAUL GREILICH, SENIOR PLANNER
 561-822-1443
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date   Cont ID  
Sent By PC Date 2017-10-20 Time   Rev Time 0.00
Received By ajones Date 2017-10-18 Time 11:03 Sent To  
Notes
2017-10-20 10:47:591.) INDICATE PROPOSED SETBACKS AND SEPARATION BETWEEN
 PROPOSED SHED AND EXISTING BUILDING
  
 PAUL GREILICH, SENIOR PLANNER
 561-822-1443
 [email protected]