| 2017-10-24 17:29:49 | PLAN |
| | REVIEW COMMENTS |
| | |
| | 2ND REVIEW: FBC FIFTH EDITION (2014) |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | DENIED BY BUILDING |
| | PREVIOUS COMMENTS HAVE NOT BEEN ADDRESSED. PLEASE |
| | ADDRESS THE ITEMS NOTED BELOW: |
| | |
| | 1) PROVIDE A FLOOR PLAN OF THE STRUCTURE WITH THE ROOM |
| | TYPES LABELED. SPECIFY THE LOCATIONS OF THE WINDOW AND |
| | DOOR THAT ARE TO BE REPLACED. SPECIFY THE SIZES OF THE |
| | WINDOW AND DOOR THAT ARE TO REPLACED. INDICATE THE |
| | SWING OF THE DOOR (IN-SWING OR OUT-SWING). FBC 107.2.1 |
| | |
| | 2) THE PRODUCT APPROVAL FOR THE WINDOW STATES THAT THE |
| | WINDOW IS NOT RATED FOR LARGE MISSILE IMPACT. INDICATE |
| | ON THE PLANS IF THERE ARE EXISTING HURRICANE PANELS OR |
| | PROVIDE CALCULATIONS TO SHOW THAT THE AGGREGATE AREA OF |
| | THE GLAZING IN THE REPLACED COMPONENTS DOES NOT EXCEED |
| | 25 PERCENT OF THE AGGREGATE AREA OF THE GLAZED OPENINGS |
| | IN THE DWELLING. |
| | 706.4 REPLACEMENT OF WINDOWS AND DOORS. |
| | THE REPLACEMENT OF GARAGE DOORS, EXTERIOR DOORS, |
| | SKYLIGHT, OPERATIVE AND INOPERATIVE WINDOWS SHALL BE |
| | DESIGNED AND CONSTRUCTED TO COMPLY WITH CHAPTER 16 OF |
| | THE FLORIDA BUILDING CODE, BUILDING. |
| | EXCEPTIONS: 1. OPENING PROTECTION EXCEPTION. FOR ONE- |
| | AND TWO-FAMILY DWELLINGS CONSTRUCTED UNDER CODES OTHER |
| | THAN THE FLORIDA BUILDING CODE AND LOCATED IN WINDBORNE |
| | DEBRIS REGIONS, THE REPLACEMENT OF GARAGE DOORS AND |
| | EXTERIOR DOORS WITH GLAZING, SLIDING GLASS DOORS, GLASS |
| | PATIO DOORS, SKYLIGHTS, AND OPERABLE AND INOPERABLE |
| | WINDOWS WITHIN ANY 12-MONTH PERIOD SHALL NOT BE |
| | REQUIRED TO HAVE OPENING PROTECTION BUT SHALL BE |
| | DESIGNED FOR WIND PRESSURES FOR ENCLOSED BUILDINGS, |
| | PROVIDED THE AGGREGATE AREA OF THE GLAZING IN THE |
| | REPLACED COMPONENTS DOES NOT EXCEED 25 PERCENT OF THE |
| | AGGREGATE AREA OF THE GLAZED OPENINGS IN THE DWELLING |
| | OR DWELLING UNIT. |
| | |
| | 3) IF THIS WINDOW IS IN A SLEEPING ROOM, SHOW THAT IT |
| | COMPLIES WITH FBC EXISTING BUILDING SECTION 704. |
| | SECTION 704 |
| | MEANS OF EGRESS |
| | 704.1 GENERAL. |
| | MEANS OF EGRESS FOR BUILDINGS UNDERGOING ALTERATION |
| | SHALL COMPLY WITH THE REQUIREMENTS OF SECTION 701.1 AND |
| | THE SCOPING PROVISIONS OF CHAPTER 1 WHERE APPLICABLE. |
| | EXCEPTION: DOOR AND WINDOW DIMENSIONS. IN RESIDENTIAL |
| | DWELLINGS AND DWELLING UNITS, A MAXIMUM OF 5-PERCENT |
| | REDUCTION IN THE CLEAR OPENING DIMENSIONS OF |
| | REPLACEMENT DOORS AND WINDOWS SHALL BE ALLOWED. |
| | |
| | |