Plan Review Details - Permit 17100523
Plan Review Stops For Permit 17100523
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-10-24 Cont ID  
Sent By jwitmer Date 2017-10-24 Time 17:28 Rev Time  
Received By jwitmer Date 2017-10-24 Time 16:46 Sent To  
Notes
2017-10-24 17:25:422014 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 17100523
 ADD: 777 S. FLAGLER DR. 3RD FLOOR COMMON AREA RESTROOMS
 CONT: BUTLER CONSTRUCTION
 TEL: 561-832-9700
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. OCT. 24/ 2017
 ACTION: DENIED
  
 1) SHEET A1.03 SHOWS IN THE COMMON AREA RESTROOMS A
 LEVEL 1 ALTERATION. THE 2014 FBC-EXISTING BUILDING CODE
 705.1 REQUIRES THE COMPLIANCE WITH FLORIDA
 ACCESSIBILITY CODE. THE PLANS SHOW THAT NEITHER
 ENTRANCE INTO THE RESTROOMS HAVE THE REQUIRED 18 INCHES
 MANEUVERING CLEARANCES ON THE INSIDE LATCH SIDE OF THE
 DOOR.
  
 ACCESS. CODE 404.2.4 MANEUVERING CLEARANCES. MINIMUM
 MANEUVERING CLEARANCES AT DOORS AND GATES SHALL COMPLY
 WITH 404.2.4. MANEUVERING CLEARANCES SHALL EXTEND THE
 FULL WIDTH OF THE DOORWAY AND THE REQUIRED LATCH SIDE
 OR HINGE SIDE CLEARANCE.
  
 THE PERMIT APPLICATION STATES THE REMODELING VALUE FOR
 THE RESTROOMS IS $75.00 DOLLARS. THE ACCESSIBILITY CODE
 CAN REQUIRE UP TO 20% OF THE CONTRACT VALUE OR
 $15,000.00 IN ACCESSIBLE UPGRADES. THE UPGRADES ARE TO
 START WITH THE ENTRANCE SEE THE ORDER IN WHICH THE
 MONIES ARE TO BE SPENT.
  
 202.4.2 ACCESSIBLE FEATURES IN THE EVENT OF
 DISPROPORTIONALITY. WHEN THE COST OF ALTERATIONS
 NECESSARY TO MAKE THE PATH OF TRAVEL TO THE ALTERED
 AREA FULLY ACCESSIBLE IS DISPROPORTIONATE TO THE COST
 OF THE OVERALL ALTERATION, THE PATH OF TRAVEL SHALL BE
 MADE ACCESSIBLE TO THE EXTENT THAT IT CAN BE MADE
 ACCESSIBLE WITHOUT INCURRING DISPROPORTIONATE COSTS. IN
 CHOOSING WHICH ACCESSIBLE ELEMENTS TO PROVIDE, PRIORITY
 SHOULD BE GIVEN TO THOSE ELEMENTS THAT WILL PROVIDE THE
 GREATEST ACCESS, IN THE FOLLOWING ORDER: (I) AN
 ACCESSIBLE ENTRANCE; (II) AN ACCESSIBLE ROUTE TO THE
 ALTERED AREA; (III) AT LEAST ONE ACCESSIBLE RESTROOM
 FOR EACH SEX OR A SINGLE UNISEX RESTROOM; (IV)
 ACCESSIBLE TELEPHONES; (V) ACCESSIBLE DRINKING
 FOUNTAINS; AND (VI) WHEN POSSIBLE, ADDITIONAL
 ACCESSIBLE ELEMENTS SUCH AS PARKING, STORAGE, AND
 ALARMS.
  
 TO MAKE THE RESTROOM DOORS ACCESSIBLE THE USE OF
 AUTOMATIC AND POWER ASSISTED DOORS WOULD BE ONE WAY TO
 COMPLY WITH: 2014 FBC-ACCESSIBILITY CODE SECTION 404.3
 AUTOMATIC AND POWER-ASSISTED DOORS AND GATES.
 AUTOMATIC DOORS AND AUTOMATIC GATES SHALL COMPLY WITH
 404.3. FULL-POWERED AUTOMATIC DOORS SHALL COMPLY WITH
 ANSI/BHMA A156.10 (INCORPORATED BY REFERENCE, SEE
 ?REFERENCED STANDARDS? IN CHAPTER 1). LOW-ENERGY AND
 POWER-ASSISTED DOORS SHALL COMPLY WITH ANSI/BHMA
 A156.19 (1997 OR 2002 EDITION) (INCORPORATED BY
 REFERENCE, SEE ?REFERENCED STANDARDS? IN CHAPTER 1).
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2017-11-13 Cont ID  
Sent By jleahy Date 2017-11-13 Time 17:30 Rev Time 0.00
Received By jleahy Date 2017-11-13 Time 17:30 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2017-10-24 Cont ID  
Sent By pleduc Date 2017-10-24 Time   Rev Time 0.00
Received By pleduc Date 2017-10-24 Time 09:43 Sent To  
Notes
2017-10-24 11:07:48THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
 1) ANY AND ALL WORK ON THE FIRE ALARM AND FIRE
 SPRINKLER SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP
 DRAWINGS AND BY CERTIFIED LIFE SAFETY CONTRACTORS.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-11-28 Cont ID  
Sent By gjohnson Date 2017-11-28 Time 09:44 Rev Time 0.00
Received By gjohnson Date 2017-10-20 Time 08:12 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-11-16 Cont ID  
Sent By ccole Date 2017-11-16 Time 15:27 Rev Time 0.00
Received By ccole Date 2017-11-16 Time 12:59 Sent To  
Notes
2017-11-16 15:29:311ST REVIEW FBC-2014 MECHANICAL
 PERMIT #17100523
 11/16/17
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) NO MECHANICAL PLAN (M0.1) WAS UPLOADED. THE PLUMBING
 PLAN (P0.1) WAS UPLOADED IN IT'S PLACE. PLEASE PROVIDE
 THE PLAN.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-11-28 Cont ID  
Sent By gjohnson Date 2017-11-28 Time 09:35 Rev Time 0.00
Received By gjohnson Date 2017-11-22 Time 17:02 Sent To  
Notes
2017-11-28 09:41:391ST REVIEW: FBC 2014 5TH EDITION
  
 PLUMBING COMMENTS:
  
 1. IT IS UNCLEAR ARE THE WATER CLOSETS AND URINALS
 BEING REMOVED AND RESET OR WILL THEY REMAIN INSTALLED
 PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1
  
 2. PLEASE PROVIDE COST BREAK DOWN TO SHOW COMPLIANCE
 WITH FBC ACC 202.4.1, 202.4.2 SEE BUILDINGS COMMENTS
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2018-09-15 Cont ID  
Sent By shill Date 2018-09-15 Time 10:35 Rev Time 0.00
Received By shill Date 2018-09-15 Time 10:35 Sent To  
Notes
2018-09-15 10:36:33SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 ALL DIGITAL SIGNATURES ARE OK, BUT NEW SHEETS SUBMITTED
 2ND REVIEW NEED VERIFICATION
  
  
2017-11-28 09:44:15PLUMB DIG SIG IS GOOD/ GPJ 11/28/17