| Plan Review Stops For Permit 17100471 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-07-10 |
|
|
Cont ID |
|
| Sent By |
rgathrig |
Date |
2018-07-10 |
Time |
12:05 |
Rev Time |
0.00 |
| Received By |
rgathrig |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2018-07-10 12:05:41 | PROVISO FOR SOUND TRANSMISSION TEST VERIFICATION WAS | | | SUBMITTED/APPROVED UNDER 17110020 (REG) |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2017-11-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-11-01 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-11-01 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2017-11-01 13:38:07 | W. P. B. REVISION: 17100471 | | | W. P. B. PERMIT: 15111020 | | | ADD: 1100 S. FLAGLER DR. SUITE: UNIT: 10 D | | | CONT: SUFFOLK | | | TEL: 561-691-4552 # 103 | | | E-MAIL: [email protected] | | | | | | 2010 FLORIDA BUILDING CODE W 2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | SUBJECT TO FAIR HOUSING! | | | | | | 1ST REVIEW | | | DATE: WED. NOV. 01/ 2017 | | | BUILDING PROVISO | | | | | | 1) SUFFOLK CONSTRUCTION TO CONDUCT SITE TESTING FOR | | | COMPLIANCE WITH THE 2010 FBC-B SECTIONS: | | | FBC-B 2010 1207.3 STRUCTURE-BORNE SOUND. | | | FBC-B 2010 1207.2 AIR-BORNE SOUND. | | | FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2. | | | THE SOUND TESTS WILL BE CONDUCTED ON A 10 INCH CONCRETE | | | SLAB UNDER THE MAIN PERMIT (15111020) AND SUBMITTED AS | | | SOON AS RESULTS ARE PRINTED AND REVIEWED BY THE | | | DESIGNER OF RECORD. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2017-11-13 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-11-13 |
Time |
17:29 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-11-13 |
Time |
17:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2017-10-30 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-10-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-10-30 |
Time |
16:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-12-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-12-13 |
Time |
12:29 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-12-05 |
Time |
16:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-11-22 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2017-11-22 |
Time |
08:16 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-10-27 |
Time |
13:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2017-11-09 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-11-09 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-11-09 |
Time |
09:47 |
Sent To |
|
|
| Notes |
| 2017-11-09 11:30:28 | MECHANICAL PROVISO: | | | PRIOR TO ISSUANCE OF CO, THE DESIGN PROFESSIONAL OF | | | RECORD SHALL CERTIFY THE APPLICATION OF THE INTUMESCENT | | | PAINT ON THE AC CLOSET DOORS. | | | CCOLE- 11/9/17 | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2017-12-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-12-15 |
Time |
12:29 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-12-13 |
Time |
11:58 |
Sent To |
|
|
| Notes |
| 2017-12-13 12:28:58 | 2010 FBC- PLUMBING PLAN REVIEW | | | W. P. B. REVISION: 17100471 | | | W. P. B. PERMIT: 15111020 | | | ADD: 1100 S. FLAGLER DR. / UNIT 10D | | | CONT: SUFFOLK | | | TEL: 561-832-1616 / JASON KRAUS | | | E-MAIL: [email protected] | | | | | | 2010 FLORIDA BUILDING CODE W 2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2ND REVIEW | | | DATE: WED. DEC. 13/ 2017 | | | ACTION: PASSEDFAIR HOUSING ACT DESIGN MANUAL PAGES | | | 7.39-7.40 | | | | | | 1) PLEASE SEE THE DOOR MAY SWING INTO THE CLEAR FLOOR | | | SPACE AT FIXTURES, PROVIDED THERE IS SPACE TO POSITION | | | A WHEELCHAIR OUTSIDE THE SWING OF THE DOOR SO IT CAN BE | | | CLOSED. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-11-17 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-11-17 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-11-17 |
Time |
13:10 |
Sent To |
|
|
| Notes |
| 2017-11-17 14:30:10 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. PLEASE REVISE SHT. A0-41 TO SHOW BATHROOM #4 AS THE | | | SPEC B BATH PER FHA DESIGN MANUAL | | | | | | 2. WHEN THE DOOR SWINGS INTO THE USABLE BATHROOM IT IS | | | REQUIRED TO HAVE A 30" X 48" CLEAR FLOOR SPACE OUTSIDE | | | THE ARC OF THE DOOR SWING, THE LAYOUT FOR BATHROOM #4 | | | IN UNIT 10D SHOWS THIS CLEAR FLOOR SPACE BEHIND THE | | | DOOR WHEN IT IS OPEN WHICH DOES NOT ALLOW A PERSON IN A | | | WHEELCHAIR TO ACCESS THIS SPACE IN ORDER TO CLOSE THE | | | DOOR I SUGGEST THE DOOR TO SWING OUT INTO THE BEDROOM | | | IN ORDER TO COMPLY. PER FHA DESIGN MANUAL PG. 7.39 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2017-12-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-12-15 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2017-11-17 14:31:42 | PLUMB DIG SIG OK 11/17/17/ GPJ | | 2017-11-09 11:38:46 | MECH DIG/SIGS GOOD- CCOLE-11/9/17 | | 2017-11-01 13:39:14 | 11/01/2017. ARCHITECTURAL SHEETS REVIEWED FOR DIGITAL | | | SIGNATURES. OK. JW |
|
|