Plan Review Details - Permit 17100299
| Plan Review Stops For Permit 17100299 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-04-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-04-09 |
Time |
17:21 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-04-09 |
Time |
08:16 |
Sent To |
|
|
| Notes |
| 2018-04-09 17:24:31 | ****PROVISOS**** | | | | | | 1. PROVIDE 2 SETS OF TRUSS DRAWINGS WITH THE ENGINEER | | | OF RECORD APPROVAL AT INSPECTION. | | | | | | 2. PRODUCT APPROVALS ARE TO BE REVIEWED BY DESIGNER OF | | | RECORD. AFTER THAT REVIEW, SUBMIT FOR REVIEW BY THE | | | BUILDING DIVISION. | | | | | | 3. WINDOW AND DOOR OPENINGS ARE TO COMPLY WITH R703.8 | | | FLASHING. | | | APPROVED CORROSION-RESISTANT FLASHING SHALL BE APPLIED | | | SHINGLE-FASHION IN A MANNER TO PREVENT ENTRY OF WATER | | | INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE | | | BUILDING STRUCTURAL FRAMING COMPONENTS. SELF-ADHERED | | | MEMBRANES USED AS FLASHING SHALL COMPLY WITH AAMA 711. | | | ALL EXTERIOR FENESTRATION PRODUCTS SHALL BE SEALED AT | | | THE JUNCTURE WITH THE BUILDING WALL WITH A SEALANT | | | COMPLYING WITH AAMA 800 OR ASTM C 920 CLASS 25 GRADE NS | | | OR GREATER FOR PROPER JOINT EXPANSION AND CONTRACTION, | | | ASTM C 1281, AAMA 812, OR OTHER APPROVED STANDARD AS | | | APPROPRIATE FOR THE TYPE OF SEALANT. THE FLASHING SHALL | | | EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH. | | | | | | PROVIDE A DETAIL AT INSPECTION. SUBJECT TO INSPECTOR'S | | | DISCRETION, A REVISION (WITH FEES) MAY BE REQUIRED. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-03-12 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-03-12 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-03-12 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2018-03-12 12:35:37 | ****PLAN REVIEW COMMENTS**** | | | | | | ART LANGE - BUILDING INSPECTOR | | | 561-805-6667 [email protected] | | | FBC FLORIDA BUILDING CODE 2014 5TH EDITION/ FRC FLORIDA | | | RESIDENTIAL CODE 2015 5TH EDITION | | | | | | SECOND REVIEW: | | | | | | | | | 1. PARTIALLY ADDRESSED, DESIGNER OF RECORD HAS NOT | | | APPROVED THE TRUSS DOCUMENTS. | | | | | | PROVIDE 2 SETS OF TRUSS DRAWINGS WITH THE ENGINEER OF | | | RECORD APPROVAL. | | | FBC 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | | THE EXAMINATION OF THE DOCUMENTS BY THE BUILDING | | | OFFICIAL SHALL INCLUDE THE FOLLOWING MINIMUM CRITERIA | | | AND DOCUMENTS: A FLOOR PLAN; SITE PLAN; FOUNDATION | | | PLAN; FLOOR/ROOF FRAMING PLAN OR TRUSS LAYOUT; ALL | | | FENESTRATION PENETRATIONS; FLASHING; AND ROUGH OPENING | | | DIMENSIONS; AND ALL EXTERIOR ELEVATIONS. | | | | | | | | | 2. OK ADDRESSED. | | | | | | IMPACT FEES | | | | | | | | | 3. PARTIALLY ADDRESSED. | | | | | | A. MULLION PRODUCT APPROVAL NOT PROVIDED. | | | B. THE DESIGNER OF RECORD HAS NOT APPROVED THE PRODUCT | | | APPROVALS. | | | C. SELECT THE ASSEMBLY USED FOR THE CERTAIN TEED | | | ROOFING TO BE USED. ONCE THE ASSEMBLY IS SELECTED, SEE | | | THE LIMITATIONS ON PAGE 19. IF LIMITATION NUMBER 7 IS | | | APPLICABLE ADDITIONAL ENHANCED UPLIFT CALCULATIONS WILL | | | BE REQUIRED. | | | | | | PROVIDE TWO SETS OF PRODUCT APPROVALS FOR THE | | | FOLLOWING: | | | ROOFING PRODUCTS, DOORS, WINDOWS AND MULLIONS AND | | | SHUTTERS IF APPLICABLE. | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING, WINDOW, AND DOOR | | | SUBMITTALS. | | | | | | 4. OK. ADDRESSED PERMIT VALUE ADJUSTED AS SUBMITTED. | | | | | | PLEASE ADJUST THE PERMITTED VALUE TO INCLUDE ALL | | | MATERIALS AND LABOR. | | | | | | | | | 5. NOT ADDRESSED. INCLUDE THIS ON THE TYPICAL WALL | | | SECTION ON A 301. | | | SHOW HOW THE WINDOW AND DOOR OPENINGS WILL COMPLY WITH | | | THIS SECTION. | | | R703.8 FLASHING. | | | APPROVED CORROSION-RESISTANT FLASHING SHALL BE APPLIED | | | SHINGLE-FASHION IN A MANNER TO PREVENT ENTRY OF WATER | | | INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE | | | BUILDING STRUCTURAL FRAMING COMPONENTS. SELF-ADHERED | | | MEMBRANES USED AS FLASHING SHALL COMPLY WITH AAMA 711. | | | ALL EXTERIOR FENESTRATION PRODUCTS SHALL BE SEALED AT | | | THE JUNCTURE WITH THE BUILDING WALL WITH A SEALANT | | | COMPLYING WITH AAMA 800 OR ASTM C 920 CLASS 25 GRADE NS | | | OR GREATER FOR PROPER JOINT EXPANSION AND CONTRACTION, | | | ASTM C 1281, AAMA 812, OR OTHER APPROVED STANDARD AS | | | APPROPRIATE FOR THE TYPE OF SEALANT. THE FLASHING SHALL | | | EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH. | | | | | | | | | WHEN RESUBMITTING, PLEASE COMPLETE A RESUBMITTAL FORM: | | | | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | THIS FORM IS ALSO AVAILABLE AT THE BUILDING DIVISION. | | | | | | ********************* | | | WHEN RESUBMITTING, SWAP OUT SHEETS WHICH HAVE CHANGED | | | SO THAT THERE ARE TWO COMPLETE, COLLATED SETS OF PLANS | | | READY FOR PERMIT ISSUANCE. OLD SHEETS ARE TO BE | | | RETAINED IN THE PERMIT APPLICATION PACKAGE (SEPARATE | | | FROM THE PERMIT SETS) AND MARKED *OLD SHEETS* OR | | | *VOID*. PLEASE KEEP BOTH SETS OF OLD VOIDED SHEETS IN | | | THE PERMIT PACKAGE. | | | ********************* | | | A RESPONSE LETTER INDICATING HOW EACH ITEM WAS | | | ADDRESSED WILL HELP TO EXPEDITE PLAN REVIEW. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-10-26 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2017-10-26 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2017-10-26 |
Time |
14:17 |
Sent To |
|
|
| Notes |
| 2017-10-26 16:08:57 | ****PLAN REVIEW COMMENTS**** | | | | | | ART LANGE - BUILDING INSPECTOR | | | 561-805-6667 [email protected] | | | FBC FLORIDA BUILDING CODE 2014 5TH EDITION/ FRC FLORIDA | | | RESIDENTIAL CODE 2015 5TH EDITION | | | | | | 1. PROVIDE 2 SETS OF TRUSS DRAWINGS WITH THE ENGINEER | | | OF RECORD APPROVAL. | | | FBC 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | | THE EXAMINATION OF THE DOCUMENTS BY THE BUILDING | | | OFFICIAL SHALL INCLUDE THE FOLLOWING MINIMUM CRITERIA | | | AND DOCUMENTS: A FLOOR PLAN; SITE PLAN; FOUNDATION | | | PLAN; FLOOR/ROOF FRAMING PLAN OR TRUSS LAYOUT; ALL | | | FENESTRATION PENETRATIONS; FLASHING; AND ROUGH OPENING | | | DIMENSIONS; AND ALL EXTERIOR ELEVATIONS. | | | | | | | | | 2. IMPACT FEES | | | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT | | | FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID. | | | UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE | | | SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN | | | IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP | | | AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE | | | CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN | | | BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY | | | IMPACT FEES AT (561) 233-5025. | | | | | | 3. PROVIDE TWO SETS OF PRODUCT APPROVALS FOR THE | | | FOLLOWING: | | | ROOFING PRODUCTS, DOORS, WINDOWS AND MULLIONS AND | | | SHUTTERS IF APPLICABLE. | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING, WINDOW, AND DOOR | | | SUBMITTALS. | | | | | | 4. PLEASE ADJUST THE PERMITTED VALUE TO INCLUDE ALL | | | MATERIALS AND LABOR. | | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE | | | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION | | | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | | (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | | INTERNATIONAL CODE CONGRESS. | | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | | BUILDING OFFICIAL. | | | | | | 5. SHOW HOW THE WINDOW AND DOOR OPENINGS WILL COMPLY | | | WITH THIS SECTION. | | | R703.8 FLASHING. | | | APPROVED CORROSION-RESISTANT FLASHING SHALL BE APPLIED | | | SHINGLE-FASHION IN A MANNER TO PREVENT ENTRY OF WATER | | | INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE | | | BUILDING STRUCTURAL FRAMING COMPONENTS. SELF-ADHERED | | | MEMBRANES USED AS FLASHING SHALL COMPLY WITH AAMA 711. | | | ALL EXTERIOR FENESTRATION PRODUCTS SHALL BE SEALED AT | | | THE JUNCTURE WITH THE BUILDING WALL WITH A SEALANT | | | COMPLYING WITH AAMA 800 OR ASTM C 920 CLASS 25 GRADE NS | | | OR GREATER FOR PROPER JOINT EXPANSION AND CONTRACTION, | | | ASTM C 1281, AAMA 812, OR OTHER APPROVED STANDARD AS | | | APPROPRIATE FOR THE TYPE OF SEALANT. THE FLASHING SHALL | | | EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH. | | | | | | WHEN RESUBMITTING, PLEASE COMPLETE A RESUBMITTAL FORM: | | | | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | THIS FORM IS ALSO AVAILABLE AT THE BUILDING DIVISION. | | | WHEN RESUBMITTING, SWAP OUT SHEETS WHICH HAVE CHANGED | | | SO THAT THERE ARE TWO COMPLETE, COLLATED SETS OF PLANS | | | READY FOR PERMIT ISSUANCE. OLD SHEETS ARE TO BE | | | RETAINED IN THE PERMIT APPLICATION PACKAGE (SEPARATE | | | FROM THE PERMIT SETS) AND MARKED *OLD SHEETS* OR | | | *VOID*. PLEASE KEEP BOTH SETS OF OLD VOIDED SHEETS IN | | | THE PERMIT PACKAGE. | | | A RESPONSE LETTER INDICATING HOW EACH ITEM WAS | | | ADDRESSED WILL HELP TO EXPEDITE PLAN REVIEW. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-03-26 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2018-03-26 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2018-03-26 |
Time |
12:57 |
Sent To |
|
|
| Notes |
| 2018-03-26 13:03:24 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | PASSED | | | | | | 1. CORRECTED | | | 2. CORRECTED | | | 3. CORRECTED | | | 4. CORRECTED | | | 5. CORRECTED | | | 6. CORRECTED | | | 7. CORRECTED | | | 8. CORRECTED | | | 9. CORRECED | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | CHIEF ELECTRICAL INSPECTOR | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-11-06 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-11-06 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-11-06 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2017-11-06 15:50:26 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO INTERIOR | | | PANEL. SHOW GEC SIZE AND SYSTEM, SHOW INTERSYSTEM | | | BONDING TERMINATION POINT. NEC 215.5, 230, 250.50, | | | 250.94, 408.30 FBC RE3706.1, RE3608.1, RE3609.3; FBC | | | 107.2.1 | | | 2. NOTE 13 STATES THAT WIRING TO BEDROOMS SHOULD BE | | | AFCI PROTECTED. THIS IS NOT THE FULL EXTENT OF THE CODE | | | REQUIREMENT: "ALL 120-VOLT, SINGLE PHASE, 15 AND 20 | | | AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS IN DWELLING | | | UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, | | | LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, | | | CLOSETS, HALLWAYS, OR SIMILAR AREAS OR ROOMS, SHALL | | | HAVE AFCI PROTECTION". PROVIDE CORRECTION IN NOTES, | | | PANEL SCHEDULE, AND PLAN. NEC 210.12; FBC RE3902.12 | | | 3. PROVIDE CARBON MONOXIDE ALARMS WITHIN 10 FEET OF | | | EACH ROOM USED FOR SLEEPING PURPOSES. FBC R315.1 | | | 4. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | | PER CODE. PROVIDE ENTIRE FLOOR PLAN SHOWING ALL | | | EXISTING ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, | | | SHOW AS NEW INSTALLATIONS. FBC R314.3, FBC 107.2.1 | | | 5. PROVIDE ACCURATE LOAD CALCULATION. THE FIRST 10KW | | | SHOULD BE FIGURED AT 100%, NOT 10%. VOLTAGE FOR SINGLE | | | PHASE SERVICE TO A RESIDENCE IS 240 VOLT. PROVIDE | | | CORRECTIONS. NEC 220; FBC RE 3602.2; FBC 107.2.1 | | | 6. A GFCI PROTECTED OUTLET ON A 20 AMP CIRCUIT IS | | | REQUIRED WITHIN 3 FEET OF EACH BASIN. PROVIDE | | | CORRECTION. THE BATH MARKED ROOM 104 DOES NOT SHOW THIS | | | REQUIRED RECEPTACLE. PROVIDE CORRECTION. NEC | | | 210.11(C)(3), 210.52(D); FBC RE 3703.4, 3901.6 | | | 7. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE4002.14 | | | 8. PROVIDE COMPLIANCE: "A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS". A NOTE WILL SUFFICE. | | | FBC CE R404.1 | | | 9. KITCHEN COUNTER RECEPTACLE OUTLETS REQUIRE A MINIMUM | | | OF TWO SMALL APPLIANCE CIRCUITS. PANEL SCHEDULE ONLY | | | SHOWS ONE. PROVIDE CORRECTION. FBC RE 3703.2 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-04-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-04-09 |
Time |
18:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-03-06 |
Time |
11:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-11-27 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2017-11-27 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2017-10-10 |
Time |
14:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2018-03-12 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-03-12 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-03-12 |
Time |
10:53 |
Sent To |
|
|
| Notes |
| 2018-03-12 10:55:15 | PALM BEACH COUNTY IMPACT FEE PAID | | | MU 2017 30737 | | | NOVEMBER 8, 2017 | | | $236.59 RECEIPT NO 2017 1127 263 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2017-11-27 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2017-11-27 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2017-11-27 |
Time |
11:31 |
Sent To |
|
|
| Notes |
| 2017-11-27 11:31:53 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT | | | FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID. | | | UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE | | | SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN | | | IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP | | | AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE | | | CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN | | | BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY | | | IMPACT FEES AT (561) 233-5025. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2018-04-09 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-04-09 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2018-04-09 |
Time |
10:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-11-27 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-11-27 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-11-27 |
Time |
10:28 |
Sent To |
|
|
| Notes |
| 2017-11-27 11:26:45 | 1ST REVIEW FBC-2014 RESIDENTIAL MECHANICAL | | | PERMIT #17100299 | | | 11/27/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET M-1: THE PLAN DOES NOT CLEARLY SHOW HOW AIR | | | WILL BE RETURNED TO THE AIR HANDLER IN THE ATTIC- SEE | | | SECTION M1602.4. | | | | | | 2) PROVIDE AN ATTIC HATCH FOR ACCESS TO THE AIR | | | HANDLER- SECTION M1305.1.3. SHOW THE LOCATION AND | | | DIMENSIONS OF THE HATCH ON THE PLAN. | | | | | | 3) REFER TO SECTION R403.2.4 FBC-14 ENERGY | | | CONSERVATION: AIR HANDLING UNITS SHALL NOT BE INSTALLED | | | IN THE ATTIC WHEN A HOME IS BROUGHT INTO CODE | | | COMPLIANCE BY SECTION R402. AIR-HANDLING UNITS SHALL BE | | | ALLOWED IN ATTICS FOR COMPLIANCE BY SECTION R405 ONLY | | | IF THE FOLLOWING CONDITIONS ARE MET: | | | | | | 1. THE SERVICE PANEL OF THE EQUIPMENT IS LOCATED WITHIN | | | 6 FEET (1829 MM) OF AN ATTIC ACCESS. | | | 2. A DEVICE IS INSTALLED TO ALERT THE OWNER OR SHUT THE | | | UNIT DOWN WHEN THE CONDENSATION DRAIN IS NOT WORKING | | | PROPERLY. | | | 3. THE ATTIC ACCESS OPENING IS OF SUFFICIENT SIZE TO | | | REPLACE THE AIR HANDLER. | | | 4. A NOTICE IS POSTED ON THE ELECTRIC SERVICE PANEL | | | INDICATING TO THE HOMEOWNER THAT THE AIR HANDLER IS | | | LOCATED IN THE ATTIC. SAID NOTICE SHALL BE IN ALL | | | CAPITALS, IN 16 POINT TYPE, WITH THE TITLE AND FIRST | | | PARAGRAPH IN BOLD. | | | | | | 4) THE AC SIZING CALCULATIONS ARE INDICATING THE FRONT | | | DOOR FACING NORTH, HOWEVER THE FRONT DOOR TO THE HOUSE | | | IS FACING SOUTH. PLEASE REVISE THE CALCULATIONS BASED | | | ON THE CORRECT ORIENTATION. | | | | | | 5) THE ENERGY COMPLIANCE FORM R405 APPEARS TO BE | | | SHOWING DIRECTIONAL ORIENTATIIONS FOR THE WINDOWS IN | | | THE COMPLIANCE DATA THAT DO NOT MATCH THE DIRECTIONAL | | | ORIENTATIONS OF THE HOUSE- PLEASE REVISE. | | | | | | 6) THE OWNER/AGENT MUST SIGN FORM R405- SECTION | | | R103.1.1.2. | | | | | | 7) SUBMIT SPEC SHEETS FOR THE COOK TOP AND RANGE HOOD. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-03-27 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2018-03-27 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2018-03-27 |
Time |
14:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2017-11-02 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2017-11-02 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2017-11-02 |
Time |
06:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2018-04-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-04-09 |
Time |
17:24 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-04-09 |
Time |
17:24 |
Sent To |
|
|
| Notes |
| 2018-04-09 17:35:11 | PROVISO: | | | | | | PRODUCT APPROVAL, REVIEWED BY DESIGNER OF RECORD, IS TO | | | BE SUBMITTED WITH ROOF PERMIT APPLICATION. | | | | | | THE PROPOSED ASSEMBLY IS TO BE PROVIDED AND, IF | | | REQUIRED, ENGINEERING FOR ENHANCED FASTENING IS TO BE | | | PROVIDED. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2017-10-18 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2017-10-18 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2017-10-17 |
Time |
13:51 |
Sent To |
|
|
| Notes |
|
|
|