Plan Review Details - Permit 17100284
Plan Review Stops For Permit 17100284
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2018-05-17 Cont ID  
Sent By skennedy Date 2018-05-17 Time 12:28 Rev Time 0.00
Received By skennedy Date 2018-05-16 Time 14:40 Sent To  
Notes
2018-05-17 12:50:004TH REVIEW: FBC 2014 5TH ED. RESIDENTIAL
  
 APPROVED WITH EXCEPTIONS
  
 THIS REVIEW IS INTENDED TO ALLOW FOR ISSUANCE WITH
 EXCEPTIONS REQUIRING ADDITIONAL SUBMITTALS PRIOR TO
 TIME OF INSPECTION.
  
 THE FOLLOWING INFORMATION BELOW NUMBERED AS NOTED IN
 PREVIOUS REVIEWS MAY BE SUBMITTED SUBSEQUENT TO
 ISSUANCE:
  
 9- ENERGY CALCULATIONS SUBMITTED:
  
 RESBMIT PAGE 1 IDENTIFYING THE CEILING INSULATION VALUE
 AS R-22. THE FORM CURRENTLY INDICATES 0.0.
  
 10- PROVIDE PRODUCT APPROVAL (TWO COPIES) AS REQUIRED
 BY FAC 61G20-3.001 FOR:
 A) ENTRY DOOR SIZE AS SHOWN ON PLANS AND TYPE OF DOOR
 SPECIFIED ON PLANS (WOOD). PROVIDE 2 COPIES. CLARIFY
 WHY SUBMITTING FLORIDA PRODUCT APPROVAL FL16708-R8.
 THIS IS NOT APPROVED YET AND IS NOT WOOD DOOR AND SIZE
 DOESN'T MATCH PLANS.
 B) ROUND WINDOWS AS SHOWN ON PLANS. REPEAT COMMENT.
 D) CLEARLY SPECIFY MULLION SIZE WINDOW MULLIONS NOA
 17-0630.01 SUBMITTED TO VERIFY COMPLIANCE WITH THE
 CALCULATED DESIGN PRESSURES.
 E) BALCONY UNDERLAYMENT SPECIFIED ON PLANS. NOTE: NEED
 PRODUCT APPROVAL THAT IS DESIGNED TO RECEIVE TILE AS
 SPECIFIED ON PLANS. CLEARLY IDENTIFY SPECIFIC ASSEMBLY
 TO BE USED. IF SELECTED ASSEMBLY DOESN'T MEET THE
 DESIGN PRESSURES FOR ALL ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS WILL BE REQUIRED.
  
  
 STEVEN KENNEDY, CBO
 ASSISTANT BUILDING OFFICIAL
 (561) 805-6710
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2018-04-11 Cont ID  
Sent By aclange Date 2018-04-11 Time 15:00 Rev Time 0.00
Received By aclange Date 2018-04-11 Time 13:02 Sent To M
Notes
2018-04-11 14:51:39****PLAN REVIEW COMMENTS****
  
 ART LANGE BUILDING PLANS EXAMINER
  
 DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS STREET
 WEST PALM BEACH, FL 33402
 561-805-6718 [email protected]
  
 NEW SINGLE FAMILY RESIDENCE (R3) SECOND BUILDING REVIEW
 CHECKLIST.
  
 CODE: FBC 5TH EDITION (2014).
 4/11/18 THIRD REVIEW:
  
 ADDRESSED COMMENTS HAVE BEEN REMOVED. NEW COMMENTS WILL
 APPEAR ON TOP OF EXISTING.
  
 5- DRAFTSTOPPING IN ATTIC NOT FOUND.
 PROVIDE DETAILS AND SPECIFICATIONS FOR DRAFSTOPPING ON
 THE SECOND FLOOR FRAMING PLAN AS REQUIRED BY SEC.
 R302.12 FBC-RESIDENTIAL. AND INDICATE ON PLANS
 DRAFSTOPPING LOCATION.
 RESPONSE: REPEAT COMMENT.
  
 7- NOT PROVIDED.
 PROVIDE ICC EVALUATION REPORT FOR SPRAY INSULATION
 SPECIFIED FOR THE UNVENTED ATTIC. ARCHITECT TO
 REVIEW/APPROVE PRIOR TO SUBMITTAL. SEC. R316
 FBC-RESIDENTIAL.
 RESPONSE: REPEAT COMMENT.
  
 8- NOT ADDRESSED.
 STRUCTURAL NOTES AND TRUSS DESIGN CRITERIA ON SHEET S2
 ARE REFERENCING ASCE 7-16. THE CURRENT ASCE 7 EDITION
 ADOPTED WITH THE 2014 FBC IS THE ASCE 7-10 NOT ASCE
 7-16. REVISE AS REQUIRED BY CHAPTER 46 FBC-RESIDENTIAL.
 RESPONSE: REPEAT COMMENT.
  
 9- NOT ADDRESSED. R405-2017 STILL USED.
 ENERGY CALCULATIONS SUBMITTED:
 A) NEW FORM R405-2017 WAS SUBMITTED. THIS FORM IS
 INCORRECT. THIS BUILDING IS BEING REVIEWED UNDER THE
 2014 FBC. NEED TO RE-SUBMIT THE FORM R405-2014 THAT WAS
 SUBMITTED THE FIRST TIME. SEC. R101.5.1.1.2 FBC-ENERGY
 CONSERVATION, 5TH EDITION (2014).
 B) NUMBER OF BEDROOMS ON ITEM #4 IS INCORRECT. SEE
 PLANS AND REVISE AS REQUIRED. SEC. R101.5.1.1.2
 FBC-ENERGY CONSERVATION.
  
 C) ROOF DECK INSULATION R-VALUE SPECIFIED ON ITEM #10
 IS INCORRECT. SEE PLANS AND REVISE AS REQUIRED. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION.
 D) SPACES INFORMATION ON PAGE 2 OF 4 IS INCORRECT. NED
 TO INCLUDE THE KITCHEN AND CORRECT NUMBER OF BEDROOMS
 AND PEOPLE. SEE PLANS AND REVISE AS REQUIRED. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION.
 REPEAT COMMENT.
 E) ROOF INFORMATION ON PAGE 2 OF 4 IS INCORRECT. REVISE
 AS REQUIRED TO MATCH PLANS. THE TYPE OF ROOF IS GABLE
 NOT HIP AND THE ROOF MATERIAL IS METAL ROOF NOT
 SHINGLES. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
 REPEAT COMMENT.
 F) THE WINDOWS INFORMATION ON PAGE 3 OF 4 DOESN'T MATCH
 PLANS. REVISE THE WINDOWS ORIENTATION AND AREA TO MATCH
 PLANS. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
 REPEAT COMMENT.
 I) PROVIDE THE COMPLETE INSPECTION CHECKLIST REQUIRED
 BY SEC. R405.4.2 (2) FBC-ENERGY CONSERVATION.
 REPEAT COMMENT.
 J) PROVIDE THE COMPLETE EPL DISPLAY CARD SIGNED BY THE
 BUILDER AS REQUIRED BY SEC. R405.4.3 FBC-ENERGY
 CONSERVATION.
 REPEAT COMMENT.
  
 10- ROUND WINDOW PRODUCT APPROVAL NOT PROVIDED.
  
 ALTERNATIVELY YOU CAN SUBMIT THESE LATER AS A DEFERRED
 SUBMITTAL BY LISTING THEM ON THE COVER SHEET.
  
 FBC 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF
 THIS SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE
 PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE
 TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO
 THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD.
  
 DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR
 APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED
 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST
 THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS
 FOR REVIEW BY THE BUILDING OFFICIAL.
  
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  
 PROVIDE PRODUCT APPROVAL (TWO COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
  
 B) ROUND WINDOWS AS SHOWN ON PLANS. REPEAT COMMENT.
  
 E) RECEIVED PRODUCT APPROVAL. BUT IT IS FOR CONCRETE
 DECKS.
  
 BALCONY UNDERLAYMENT SPECIFIED ON PLANS. NOTE: NEED
 PRODUCT APPROVAL THAT IS DESIGNED TO RECEIVE TILE AS
 SPECIFIED ON PLANS. CLEARLY IDENTIFY SPECIFIC ASSEMBLY
 TO BE USED. IF SELECTED ASSEMBLY DOESN'T MEET THE
 DESIGN PRESSURES FOR ALL ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS WILL BE REQUIRED.
 RESPONSE: KEMPEROL MEMBRANE WATERPROOFING SYSTEM
 SUBMITTED IS FOR CONCRETE DECKS. THIS IS A WOOD DECK.
 PROVIDE PROPER PRODUCT APPROVAL. AND IDENTIFY SELECTED
 ASSEMBLY AS REQUESTED ABOVE.
  
  
  
 *** PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO HELP EXPEDITE THE REVIEW PROCESS.
 **** PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT ALL DRAWINGS
 FOR REFERENCE.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2018-03-08 Cont ID  
Sent By jgomez Date 2018-03-08 Time 15:40 Rev Time 0.00
Received By jgomez Date 2018-03-08 Time 15:04 Sent To  
Notes
2018-03-14 17:33:5103/14/18
 NOTE: COMPLETE THE NEW RESIDENCE INFORMATION: AREA,
 NUMBER OF BEDROOMS, ETC.
2018-03-08 15:15:23NEW SINGLE FAMILY RESIDENCE (R3) SECOND BUILDING REVIEW
 CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 1- IMPACT FEES:
 BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.
  
 2- GENERAL CONTRACTOR CAN NOT DO THE METAL ROOFING.
 SEC. 489.113(3) FLORIDA STATUTE. GENERAL CONTRACTOR
 NEEDS TO SUBCONTRACT THE METAL ROOFING WORK TO A
 LICENSED ROOFING CONTRACTOR. SEPARATE ROOFING PERMIT
 APPLICATION NEEDS TO BE FILL UP BY THE LICENSED ROOFING
 CONTRACTOR.
 RESPONSE: REPEAT COMMENT.
  
 3- PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH SEC.
 R401.3 FBC-RESIDENTIAL.
 RESPONSE: REPEAT COMMENT.
 4-PROVIDE DETAILS AND SPECIFICATIONS FOR STAIRWAY
 FIREBLOCKING AS REQUIRED BY SEC. R302.11
 FBC-RESIDENTIAL.
 RESPONSE: REPEAT COMMENT.
 5- PROVIDE DETAILS AND SPECIFICATIONS FOR DRAFSTOPPING
 ON THE SECOND FLOOR FRAMING PLAN AS REQUIRED BY SEC.
 R302.12 FBC-RESIDENTIAL. AND INDICATE ON PLANS
 DRAFSTOPPING LOCATION.
 RESPONSE: REPEAT COMMENT.
 6- PROVIDE COMPLETE GABLE END DETAIL COMPLYING WITH
 SEC. R609.4 FBC-RESIDENTIAL. CLEARLY SPECIFY ALL
 FRAMING MEMBERS AND FASTENERS.
 RESPONSE TO DETAIL 9/A2.2 SUBMITTED: DON'T CITE ANY
 SECTIONS OR TABLE FROM THE CODE. DESIGNER OF RECORD IS
 RESPONSIBLE FOR THE STRUCTURAL DESIGN OF THE GABLE END.
 CLEARLY SPECIFY ALL CONNECTORS. SPECIFY ALL GABLE END
 BRACING MEMBERS NAIL SIZE AND NUMBER. NOTE: ROOF
 SHEATHING NAILS NEED TO BE 8D RING SHANK. REVISE AS
 REQUIRED.
  
 7- PROVIDE ICC EVALUATION REPORT FOR SPRAY INSULATION
 SPECIFIED FOR THE UNVENTED ATTIC. ARCHITECT TO
 REVIEW/APPROVE PRIOR TO SUBMITTAL. SEC. R316
 FBC-RESIDENTIAL.
 RESPONSE: REPEAT COMMENT.
  
 8- STRUCTURAL NOTES AND TRUSS DESIGN CRITERIA ON SHEET
 S2 ARE REFERENCING ASCE 7-16. THE CURRENT ASCE 7
 EDITION ADOPTED WITH THE 2014 FBC IS THE ASCE 7-10 NOT
 ASCE 7-16. REVISE AS REQUIRED BY CHAPTER 46
 FBC-RESIDENTIAL.
 RESPONSE: REPEAT COMMENT.
  
 9- ENERGY CALCULATIONS SUBMITTED:
 A) NEW FORM R405-2017 WAS SUBMITTED. THIS FORM IS
 INCORRECT. THIS BUILDING IS BEING REVIEWED UNDER THE
 2014 FBC. NEED TO RE-SUBMIT THE FORM R405-2014 THAT WAS
 SUBMITTED THE FIRST TIME. SEC. R101.5.1.1.2 FBC-ENERGY
 CONSERVATION, 5TH EDITION (2014).
  
 B) NUMBER OF BEDROOMS ON ITEM #4 IS INCORRECT. SEE
 PLANS AND REVISE AS REQUIRED. SEC. R101.5.1.1.2
 FBC-ENERGY CONSERVATION.
  
 C) ROOF DECK INSULATION R-VALUE SPECIFIED ON ITEM #10
 IS INCORRECT. SEE PLANS AND REVISE AS REQUIRED. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 D) SPACES INFORMATION ON PAGE 2 OF 4 IS INCORRECT. NED
 TO INCLUDE THE KITCHEN AND CORRECT NUMBER OF BEDROOMS
 AND PEOPLE. SEE PLANS AND REVISE AS REQUIRED. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION.
 REPEAT COMMENT.
  
 E) ROOF INFORMATION ON PAGE 2 OF 4 IS INCORRECT. REVISE
 AS REQUIRED TO MATCH PLANS. THE TYPE OF ROOF IS GABLE
 NOT HIP AND THE ROOF MATERIAL IS METAL ROOF NOT
 SHINGLES. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
 REPEAT COMMENT.
  
 F) THE WINDOWS INFORMATION ON PAGE 3 OF 4 DOESN'T MATCH
 PLANS. REVISE THE WINDOWS ORIENTATION AND AREA TO MATCH
 PLANS. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
 REPEAT COMMENT.
  
 I) PROVIDE THE COMPLETE INSPECTION CHECKLIST REQUIRED
 BY SEC. R405.4.2 (2) FBC-ENERGY CONSERVATION.
 REPEAT COMMENT.
  
 J) PROVIDE THE COMPLETE EPL DISPLAY CARD SIGNED BY THE
 BUILDER AS REQUIRED BY SEC. R405.4.3 FBC-ENERGY
 CONSERVATION.
 REPEAT COMMENT.
  
 10- PROVIDE PRODUCT APPROVAL (TWO COPIES) AS REQUIRED
 BY FAC 61G20-3.001 FOR:
 A) ENTRY DOOR SIZE AS SHOWN ON PLANS AND TYPE OF DOOR
 SPECIFIED ON PLANS (WOOD). PROVIDE 2 COPIES. CLARIFY
 WHY SUBMITTING FLORIDA PRODUCT APPROVAL FL16708-R8.
 THIS IS NOT APPROVED YET AND IS NOT WOOD DOOR AND SIZE
 DOESN'T MATCH PLANS.
  
 B) ROUND WINDOWS AS SHOWN ON PLANS. REPEAT COMMENT.
  
 D) WINDOW MULLIONS NOA 17-0630.01 SUBMITTED. CLEARLY
 SPECIFY MULLION SIZE TO VERIFY COMPLIANCE WITH THE
 CALCULATED DESIGN PRESSURES. AND, PROVIDE LEGIBLE
 DRAWINGS. PLEAS PRINT THEM IN LANDSCAPE FORMAT SO
 DRAWINGS ARE MORE LEGIBLE.
  
 E) BALCONY UNDERLAYMENT SPECIFIED ON PLANS. NOTE: NEED
 PRODUCT APPROVAL THAT IS DESIGNED TO RECEIVE TILE AS
 SPECIFIED ON PLANS. CLEARLY IDENTIFY SPECIFIC ASSEMBLY
 TO BE USED. IF SELECTED ASSEMBLY DOESN'T MEET THE
 DESIGN PRESSURES FOR ALL ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS WILL BE REQUIRED.
 RESPONSE: KEMPEROL MEMBRANE WATERPROOFING SYSTEM
 SUBMITTED IS FOR CONCRETE DECKS. THIS IS A WOOD DECK.
 PROVIDE PROPER PRODUCT APPROVAL. AND IDENTIFY SELECTED
 ASSEMBLY AS REQUESTED ABOVE.
  
 11- DESIGNER OF RECORD TO APPROVE ABOVE PRODUCT
 APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY
 AMENDMENTS.
  
 NOTE: PROVIDE MANUFACTURER'S CUT SHEETS FOR SECOND
 FLOOR EGRESS WINDOWS TO VERIFY COMPLIANCE WITH ALL MIN.
 OPENING REQUIREMENTS. SOME WINDOWS DEPENDING ON THE
 SPECIFIC MODEL DON'T COMPLY WITH ALL THE REQUIREMENTS.
 THIS WILL AVOID CONFLICTS/DELAYS.
  
  
 *** PLEASE PROVIDE RESPONSE LETTER ADDRESING EACH
 COMMENT TO HELP EXPEDITE THE REVIEW PROCESS.
 **** PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT ALL DRAWINGS
 FOR REFERENCE.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-11-13 Cont ID  
Sent By destabro Date 2017-11-08 Time 14:10 Rev Time 0.00
Received By jgomez Date 2017-11-08 Time 09:29 Sent To I
Notes
2017-11-07 18:38:25NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW
 COMMENTS.
 CODE: FBC 5TH EDITION (2014).
  
 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD.) FOR IMPACT FEE ASSESSMENT.
 BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID
 RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF
 THE LAND DEVELOPMENT CODE.
  
 2- GENERAL CONTRACTOR CAN NOT DO THE METAL ROOFING.
 SEC. 489.113(3) FLORIDA STATUTE. GENERAL CONTRACTOR
 NEEDS TO SUBCONTRACT THE METAL ROOFING WORK TO A
 LICENSED ROOFING CONTRACTOR. SEPARATE ROOFING PERMIT
 APPLICATION NEEDS TO BE FILL UP BY THE LICENSED ROOFING
 CONTRACTOR.
  
 3- ENTRY DOOR SIZE (2480) SPECIFIED ON THE 1ST FLOOR
 PLAN ON SHEET A1.1 DOESN'T COMPLY WITH SEC. R311.2
 FBC-RESIDENTIAL, 5TH EDITION (2014). REVISE AS
 REQUIRED.
  
 4- PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH SEC.
 R401.3 FBC-RESIDENTIAL.
  
 5- SOIL TEST REPORT SUBMITTED NEEDS THE ENGINEER'S
 ORIGINAL SEAL AND SIGNATURE AS REQUIRED BY CHAPTER 471
 FLORIDA STATUTE WHEN SUBMITTING DOCUMENTS FOR PUBLIC
 RECORDS.
  
 6- SPECIFY THE SIZE OF THE ATTIC ACCESS SHOWN ON THE
 SECOND FLOOR PLAN ON SHEET A1.1. SEC. R807
 FBC-RESIDENTIAL.
  
 7- THE SIZE OF THE BATHROOM DOOR ON THE FIRST FLOOR
 DOESN'T PROVIDE A CLEAR DOOR OPENING OF 29" AS REQUIRED
 BY SEC. R320 FBC-RESIDENTIAL. REVISE AS REQUIRED.
  
 8- PROVIDE DETAILS AND SPECIFICATIONS FOR STAIRWAY
 FIREBLOCKING AS REQUIRED BY SEC. R302.11
 FBC-RESIDENTIAL.
  
 9- PROVIDE DETAILS AND SPECIFICATIONS FOR DRAFSTOPPING
 ON THE SECOND FLOOR FRAMING PLAN AS REQUIRED BY SEC.
 R302.12 FBC-RESIDENTIAL.
  
 10- CLARIFY WINDOW "F" SHOWN ON THE FLOOR PLANS. THERE
 IS NOT WINDOW "F" ON THE WINDOW ELEVATION SCHEDULE ON
 SHEET A2.2. REVISE AS REQUIRED TO MATCH. SEC. 107.2.1
 CITY AMENDMENTS.
  
 11- PROVIDE COMPLETE GABLE END DETAIL COMPLYING WITH
 SEC. R609.4 FBC-RESIDENTIAL. SPECIFY ALL FRAMING
 MEMBERS, INCLUDING TOP AND BOTTOM PLATES AND ALL
 CONNECTORS.
  
 12- WOOD FRAMED GABLE END:
 A) SPECIFY THE TWO LAYERS OF WATER RESISTIVE BARRIERS
 AS REQUIRED BY SEC. R703.6.3 FBC-RESIDENTIAL.
  
 B) ARCHITECT IS DESIGNING AN UNVENTED ATTIC, THEREFORE
 NEEDS TO SPECIFY THE WALL INSULATION OF THE GABLE END
 WALL. SEC. R103.2 FBC-ENERGY CONSERVATION.
  
 13- A) ARCHITECT IS DESIGNING AN UNVENTED ATTIC.
 PROVIDE COMPLETE DETAILS AND SPECIFICATIONS ON PLANS
 SHOWING COMPLIANCE WITH THE REQUIREMENTS OF SEC. R806.5
 FBC-RESIDENTIAL.
  
 B) PROVIDE ICC EVALUATION REPORT FOR INSULATION
 SPECIFIED FOR THE UNVENTED ATTIC TO VERIFY COMPLIANCE
 WITH SEC. R806.5 AND SEC. R302.10 FBC-RESIDENTIAL.
  
 14-SECOND FLOOR FRAMING PLAN ON SHEET S1: SPECIFY HOW
 MUCH EMBEDMENT IS REQUIRED FOR THE ANCHOR BOLTS
 SPECIFIED FOR THE STRUCTURAL WOOD LEDGER SUPPORTING THE
 SECOND FLOOR TRUSSES. SEC. R301.1 FBC-RESIDENTIAL.
  
 15- FOUNDATION SCHEDULE ON SHEET S2 IS MISSING FOOTING
 F3 SHOWN ON 1ST FLOOR FRAMING ON SHEET S1. SEC. R301.1
 FBC-RESIDENTIAL.
  
 16- COVER ENTRY AND REAR OUTDOOR COVERED PATIO 1ST
 FLOOR FRAMING PLAN ON SHEET S1 SPECIFIES "DC-1" BY THE
 COLUMNS. IT IS NOT CLEAR WHAT'S DOES "DC-1" STAND FOR.
 CLARIFY AS REQUIRED. SEC. 107.2.1 CITY AMENDMENTS.
  
 17- BEAM SCHEDULE ON SHEET S2 IS MISSING THE "CB-1"
 BEAM SPECIFIED ON THE ENTRY ROOF FRAMING PLAN ON SHEET
 S1. SEC. R301.1 FBC-RESIDENTIAL.
  
 18- LEFT SIDE ELEVATION ON SHEET A3.1 IS NOT THE EAST
 ELEVATION. IT IS THE WEST ELEVATION. AND, RIGHT SIDE
 ELEVATION ON SHEET A3.2 IS NOT THE WEST ELEVATION. IT'S
 THE EAST ELEVATION. REVISE AS REQUIRED MATCH PLANS.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 19- SIZE OF FOOTING F-2 SPECIFIED ON THE FOOTING
 SCHEDULE ON SHEET S2 DOESN'T MATCH SIZE REPRESENTED ON
 THE 1ST FRAMING PLAN ON SHEET S1. REVISE AS REQUIRED.
 SEC. R301.1 FBC-RESIDENTIAL.
  
 20- SIZE OF FOOTING F-4 AND F-5 SPECIFIED ON THE
 FOOTING SCHEDULE ON SHEET S2 DOESN'T MATCH SIZE
 REPRESENTED ON 1ST FRAMING PLAN ON SHEET S1 AND IS NOT
 CLEAR. IS THIS A CONCRETE PAD OR A CONTINUOUS FOOTING.
 SEC. R301.1 FBC-RESIDENTIAL.
  
 21- STRUCTURAL NOTES, WIND DESIGN CHART AND TRUSS
 DESIGN CRITERIA ON SHEET S2 ARE REFERENCING ASCE 7-16.
 THE CURRENT ASCE 7 EDITION ADOPTED WITH THE 2014 FBC IS
 THE ASCE 7-10 NOT ASCE 7-16. REVISE AS REQUIRED BY
 CHAPTER 46 FBC-RESIDENTIAL.
  
 22- REVISE ENERGY CALCULATIONS FORM R405-2014
 SUBMITTED:
 A) PROVIDE COMPLETE INFORMATION ON TOP OF FORM,
 INCLUDING BUILDER'S NAME, PERMIT OFFICE AND
 JURISDICTION NUMBER (604700). SEC. R101.5.1.1.2
 FBC-ENERGY CONSERVATION, 5TH EDITION (2014).
  
 B) CONDITIONED FLOOR AREA SHOWN ON ITEM #6 DOESN'T
 MATCH CONDITIONED AREA SHOWN ON ARCHITECTURAL PLANS.
 REVISE AS REQUIRED TO MATCH. SEC. R101.5.1.1.2
 FBC-ENERGY CONSERVATION.
  
 C) WALL TYPES ON ITEM #9 NEED TO INCLUDE THE FRAMED
 WALL INFORMATION OF THE GABLE END AREAS. SEE
 ARCHITECT'S REVISED PLANS AND REVISE AS REQUIRED. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 D) CEILING INSULATION AND AREA SHOWN ON ITEM #10 DON'T
 MATCH PLANS. REVISE AS REQUIRED. SEC. R101.5.1.1.2
 FBC-ENERGY CONSERVATION.
  
 E) SPACES INFORMATION ON PAGE 2 OF 4 IS INCORRECT AND
 INCOMPLETE. REVISE THE AREA OF EACH FLOOR. WHY THERE IS
 NOT KITCHEN ON THE FIRST FLOOR?, SPECIFY THE NUMBER OF
 BEDROOMS. SPECIFY NUMBER OF OCCUPANTS BASED ON THE
 NUMBER OF BEDROOMS. SEC. R101.5.1.1.2 FBC-ENERGY
 CONSERVATION.
  
 F) ROOF INFORMATION ON PAGE 2 OF 4 IS INCORRECT. REVISE
 AS REQUIRED TO MATCH PLANS. THE TYPE OF ROOF IS GABLE
 NOT HIP AND THE ROOF MATERIAL IS METAL ROOF NOT
 SHINGLES. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
 NOTE: COORDINATE WITH ARCHITECT AND CONTRACTOR TO AVOID
 CONFLICTS/DELAYS. SEE ITEM #23 BELOW.
  
 G) THE CEILING R-VALUE AND AREA SPECIFIED ON PAGE 2 OF
 4 DON'T MATCH PLANS. REVISE AS REQUIRED TO MATCH. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 H) THE WINDOWS INFORMATION ON PAGE 3 OF 4 DOESN'T MATCH
 PLANS AND PRODUCT APPROVALS SUBMITTED. REVISE AS
 REQUIRED TO MATCH. REVISE THE WINDOWS ORIENTATION,
 WINDOWS AREA AND WINDOWS OVERHANG DEPTH AND SEPARATION
 TO MATCH PLANS. SEC. R101.5.1.1.2 FBC-ENERGY
 CONSERVATION.
  
 I) PROVIDE THE COMPLETE INSPECTION CHECKLIST REQUIRED
 BY SEC. R405.4.2 (2) FBC-ENERGY CONSERVATION.
  
 J) PROVIDE THE COMPLETE EPL DISPLAY CARD SIGNED BY THE
 BUILDER AS REQUIRED BY SEC. R405.4.3 FBC-ENERGY
 CONSERVATION.
  
 23- IT IS NOT CLEAR WHAT TYPE OF ROOFING MATERIAL IS
 GOING TO BE USED. PLANS CALL FOR METAL ROOFING, WHILE
 PRODUCT APPROVAL SUBMITTED IS FOR SHINGLES. REVISE AS
 REQUIRED TO MATCH. SEC. 107.2.1 CITY AMENDMENTS.
  
 24- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 A) ROOF MATERIAL TO BE USED. COORDINATE WITH ITEM #23
 ABOVE TO AVOID CONFLICTS/DELAYS.
  
 B) IF USING SHINGLES, THEN THE RIDGE CAP SHINGLES NOA
 13-0306.08 SUBMITTED EXPIRED ON 10/17/17. PROVIDE
 CURRENT NOA.
  
 C) ENTRY DOOR AS SHOWN ON PLANS. PROVIDE FLORIDA
 PRODUCT APPROVAL COVER PAGE THAT CORRESPOND TO DRAWINGS
 ET0003 SUBMITTED. NOTE: IF THERE IS NOT FLORIDA PRODUCT
 APPROVAL, THEN MANUFACTURER MAY SUBMIT COMPLETE
 ORIGINAL ENGINEER DRAWINGS FOR BUILDING OFFICIAL
 APPROVAL. CONTACT ME FOR MORE INFORMATION.
  
 D) ROUND WINDOWS AS SHOWN ON PLANS.
  
 E) WINDOW MULLIONS AS SPECIFIED ON PLANS. AND, CLEARLY
 IDENTIFY MULLION SIZE TO VERIFY COMPLIANCE WITH THE
 CALCULATED DESIGN PRESSURES.
  
 F) BALCONY UNDERLAYMENT SPECIFIED ON PLANS. NOTE: NEED
 PRODUCT APPROVAL THAT IS DESIGNED TO RECEIVE TILE AS
 SPECIFIED ON PLANS. CLEARLY IDENTIFY SPECIFIC ASSEMBLY
 TO BE USED. IF SELECTED ASSEMBLY DOESN'T MEET THE
 DESIGN PRESSURES FOR ALL ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS WILL BE REQUIRED.
  
 G) PRECAST LINTEL AS SPECIFIED ON PLANS.
  
 25- DESIGNER OF RECORD TO APPROVE ABOVE PRODUCT
 APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY
 AMENDMENTS.
  
 *** PLEASE PROVIDE RESPONSE LETTER ADDRESING EACH
 COMMENT TO HELP EXPEDITE THE REVIEW PROCESS.
 **** PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT ALL DRAWINGS
 FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-02-27 Cont ID  
Sent By jpearson Date 2018-02-27 Time 09:28 Rev Time 0.00
Received By jpearson Date 2018-02-27 Time 09:28 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-11-06 Cont ID  
Sent By jpearson Date 2017-11-06 Time 14:12 Rev Time 0.00
Received By jpearson Date 2017-11-06 Time 14:12 Sent To  
Notes
2017-11-06 14:12:47CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION
 NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE 20 AMP CIRCUIT FOR BATHROOM GFCI RECEPTACLE
 OUTLETS. A MINIMUM OF ONE 20 AMPERE BRANCH CIRCUIT
 SHALL BE PROVIDED TO SUPPLY BATHROOM RECEPTACLE
 OUTLET(S). SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS.
 FBC RE3703.4
 2. WATER HEATER SHOULD BE ON A 25 AMP BREAKER. PROVIDE
 CORRECTION. BREAKER SHOULD BE SIZED AT 125% OF THE
 LOAD. PROVIDE CORRECTION. NEC 422.13; FBC RE3702.10
 3. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT
 SERVICE. NEC 250.94; FBC RE3609.3
 4. PROVIDE EVIDENCE OF RESISTANCE TO GROUND ROD OF 25
 OHMS OR LESS PER CODE, OR PROVIDE ADDITIONAL ELECTRODE
 6 FEET AWAY. NEC 250.56; FBC RE 36008.4
 5. CONNECT TO ALL AVAILABLE GROUNDING ELECTRODES,
 INCLUDING THE CONCRETE ENCASED ELECTRODE. PROVIDE
 CORRECTION. NEC 250.50; FBC RE 3608.1
 6. PROVIDE COMPLIANCE: "A MINIMUM OF 75 PERCENT OF THE
 LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF
 THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 CONTAIN ONLY HIGH EFFICACY LAMPS". A NOTE WILL SUFFICE.
 FBC CE R404.1
 7. PROVIDE COMPLIANCE: "ALL 120-VOLT, SINGLE PHASE, 15
 AND 20 AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS IN
 DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS,
 PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS,
 RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR AREAS
 OR ROOMS, SHALL HAVE AFCI PROTECTION". A NOTE WILL
 SUFFICE. NEC 210.12; FBC RE3902.12
 8. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A
 NOTE WILL SUFFICE. NEC 406.12; FBC RE4002.14
 9. ALL OUTSIDE RECEPTACLES REQUIRE GFCI PROTECTION,
 INCLUDING RECEPTACLES IS SOFFIT. THE GFCI DEVICE FOR
 RECEPTACLES IN SOFFIT SHALL BE IN A READILY ACCESSIBLE
 LOCATION. PROVIDE CORRECTION. NEC 210.8; FBC RE 3902.3
 10. SMOKE/CO ALARM REQUIRED ON EACH LEVEL OF DWELLING
 UNIT. PROVIDE CORRECTION. ALSO, PROVIDE SMOKE ALARM FOR
 DEN, WHICH HAS A CLOSET AND COULD BE USED FOR SLEEPING
 PURPOSE. FBC RE 314.3
 11. THE WALL SPACING REQUIREMENTS FOR KITCHEN COUNTER
 SPACE STATE THAT RECEPTACLE OUTLETS SHALL BE INSTALLED
 SO THAT NO POINT ALONG THE WALL LINE IS MORE THAN 24
 INCHES MEASURED HORIZONTALLY FROM A RECEPTACLE OUTLET
 IN THAT SPACE. THE PLAN PROVIDED DOES NOT MEET THIS
 CODE IN SOME AREAS. PROVIDE CORRECTION. NEC
 210.52(C)(1); FBC RE3901.4
 12. A GFCI PROTECTED OUTLET ON A 20 AMP CIRCUIT IS
 REQUIRED WITHIN 3 FEET OF EACH BASIN. PROVIDE
 CORRECTION FOR POWDER BATH. NEC 210.11(C)(3),
 210.52(D); FBC RE 3703.4, 3901.6
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2017-11-03 Cont ID  
Sent By gjohnson Date 2017-11-03 Time 10:38 Rev Time 0.00
Received By gjohnson Date 2017-11-03 Time 10:38 Sent To  
Notes
2017-11-03 10:39:53GAS PLAN REVIEW
 A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL
 PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT
 THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE
 REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK.
 PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT
 SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE
 SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC.
 107.2.1.
  
 GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE
 FBC-R, SEC. G2404.3.
 GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL
 GAS SEC. 301.3.
  
 A SEPARATE PERMIT IS REQUIRED FOR THE GAS INSTALLATION.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2018-02-15 Cont ID  
Sent By destabro Date 2018-02-15 Time 15:38 Rev Time 0.00
Received By destabro Date 2018-02-15 Time 15:38 Sent To B
Notes
2018-02-15 15:39:362/15/18 - REVISED PLANS STILL MEET CONDITIONS SET FORTH
 IN HPB CASE NO.16-97; APPROVAL. DLE

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2017-10-26 Cont ID  
Sent By destabro Date 2017-10-26 Time 13:49 Rev Time 0.00
Received By destabro Date 2017-10-26 Time 13:59 Sent To B
Notes
2017-10-26 13:54:3810/26/2017 - WE NOTE THAT SEVERAL MINOR CHANGES WERE
 MADE TO THE FENESTRATION PATTERN ON THE FRONT AND REAR
 ELEVATIONS - HOWEVER, THOSE DO NOT SUBSTANTIALLY DIFFER
 FROM THE APPROVED PLANS PER HPB CASE NO. 16-97. SOME
 2/1-LIGHT WINDOWS HAVE REVERTED TO 4/1-LIGHT AND OTHER
 4/1-LIGHT WINDOWS ARE NOW 6/1-LIGHT, TO MAINTAIN
 CONSISTENT PROPORTIONAL OPENINGS. STAFF SUPPORTS THESE
 CHANGES. HOWEVER, THE PRODUCT APPROVAL FOR 5V METAL
 CRIMP ROOFING MATERIAL IS MISSING - PER PLANS, METAL
 ROOF IS PROPOSED, NOT ASPHALT SHINGLE. PLEASE REMEDY
 FOR BUILDING DEPT. DLE

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2018-05-17 Cont ID  
Sent By skennedy Date 2018-05-17 Time 12:50 Rev Time 0.00
Received By skennedy Date 2018-05-07 Time 15:56 Sent To  
Notes
2018-05-08 15:57:03RESUB ROUTED TO JGOMEZ

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2018-04-25 Cont ID  
Sent By cpuell Date 2018-04-25 Time 14:46 Rev Time 0.00
Received By cpuell Date 2018-04-23 Time 13:42 Sent To  
Notes
2018-04-24 13:42:37RESUB ROUTED TO CMONTELL

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-04-17 Cont ID  
Sent By cmontell Date 2018-04-17 Time 13:12 Rev Time 0.00
Received By cmontell Date 2018-04-17 Time 13:12 Sent To  
Notes
2018-04-05 14:16:40RESUB ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-03-08 Cont ID  
Sent By jgomez Date 2018-03-08 Time 19:02 Rev Time 0.00
Received By jgomez Date 2018-02-06 Time 14:50 Sent To I
Notes
2018-02-07 14:50:41R42

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-11-13 Cont ID  
Sent By jgomez Date 2017-11-13 Time 17:22 Rev Time 0.00
Received By jgomez Date 2017-10-10 Time 15:32 Sent To  
Notes
2017-10-11 15:32:51R42

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 4 Status P Date 2018-05-22 Cont ID  
Sent By skennedy Date 2018-05-22 Time 09:11 Rev Time 0.00
Received By skennedy Date 2018-05-22 Time 09:11 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status F Date 2018-04-11 Cont ID  
Sent By aclange Date 2018-04-11 Time 14:30 Rev Time 0.00
Received By aclange Date 2018-04-11 Time 14:30 Sent To  
Notes
2018-04-11 14:30:27IMPACT FEES
  
 BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.
  
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2018-03-08 Cont ID  
Sent By jgomez Date 2018-03-08 Time 15:23 Rev Time 0.00
Received By jgomez Date 2018-03-08 Time 15:23 Sent To  
Notes
2018-03-08 15:23:54IMPACT FEES
  
 BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.
  
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2017-11-08 Cont ID  
Sent By jgomez Date 2017-11-08 Time 17:44 Rev Time 0.00
Received By jgomez Date 2017-11-08 Time 17:44 Sent To  
Notes
2017-11-08 17:46:211- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD.) FOR IMPACT FEE ASSESSMENT.
 BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID
 RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF
 THE LAND DEVELOPMENT CODE.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2018-04-24 Cont ID  
Sent By cmontell Date 2018-04-24 Time 14:29 Rev Time 0.00
Received By cmontell Date 2018-04-24 Time 14:26 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2018-04-17 Cont ID  
Sent By cmontell Date 2018-04-17 Time 13:10 Rev Time 0.00
Received By cmontell Date 2018-04-17 Time 13:01 Sent To  
Notes
2018-04-17 13:09:16NEEDS SIGNATURE ON 2 SETS OF PLANS BEFORE PERMIT ISSUED

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2018-03-08 Cont ID  
Sent By jgomez Date 2018-03-08 Time 18:49 Rev Time 0.00
Received By jgomez Date 2018-03-08 Time 18:48 Sent To  
Notes
2018-03-08 18:59:45NEW SINGLE FAMILY RESIDENCE (R3) SECOND MECHANICAL
 REVIEW CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 1- PROVIDE COMPLETE EQUIPMENT SIZING CALCULATIONS BASED
 ON THE ACTUAL ORIENTATION OF THE BUILDING AS REQUIRED
 BY SEC. R403.6.1 FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014).
 RESPONSE: REPEAT COMMENT.
  
 2- A/C PLAN TO HAVE THE NAME AND SIGNATURE OF THE
 CONTRACTOR RESPONSIBLE FOR THE DESIGN. SEC. 107.2.1
 CITY AMENDMENTS.
 RESPONSE: REPEAT COMMENT.
  
 3- NEED EXHAUST FAN FOR THE MASTER BATHROOM. ONLY ONE
 EXHAUST FAN IS PROVIDED FOR THE WATER CLOSET
 COMPARTMENT. REVISE AS REQUIRED. TABLE M1507.4
 FBC-RESIDENTIAL, 5TH EDITION (2014).
 RESPONSE: REPEAT COMMENT.
  
 4- SPECIFY CLOTHES DRYER EXHAUST AS REQUIRED BY SEC.
 M1502 FBC-RESIDENTIAL.
 RESPONSE: REPEAT COMMENT.
  
 *** PLEASE PROVIDE RESPONSE LETTER ADDRESING EACH
 COMMENT TO HELP EXPEDITE THE REVIEW PROCESS.
 **** PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT ALL DRAWINGS
 FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-11-13 Cont ID  
Sent By jgomez Date 2017-11-13 Time 17:21 Rev Time 0.00
Received By jgomez Date 2017-11-13 Time 17:07 Sent To I
Notes
2017-11-13 17:18:15NEW SINGLE FAMILY RESIDENCE (R3) MECHANICAL REVIEW
 COMMENTS.
 CODE: FBC 5TH EDITION (2014).
  
 1- PROVIDE COMPLETE EQUIPMENT SIZING CALCULATIONS BASED
 ON THE ACTUAL ORIENTATION OF THE BUILDING AS REQUIRED
 BY SEC. R403.6.1 FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014).
 NOTE: SEE BUILDING REVIEW COMMENTS REGARDING ENERGY
 CALCULATIONS REQUIRED REVISIONS.
  
 2- A/C PLAN TO HAVE THE NAME AND SIGNATURE OF THE
 CONTRACTOR RESPONSIBLE FOR THE DESIGN. SEC. 107.2.1
 CITY AMENDMENTS.
  
 3- A/C PLAN TO SHOW THE CFM'S ON ALL REGISTERS SHOWN ON
 PLANS. SEC. 107.2.1 CITY AMENDMENTS.
  
 4- NEED EXHAUST FAN FOR THE MASTER BATHROOM. ONLY ONE
 EXHAUST FAN IS PROVIDED FOR THE WATER CLOSET
 COMPARTMENT. REVISE AS REQUIRED. TABLE M1507.4
 FBC-RESIDENTIAL, 5TH EDITION (2014).
  
 5- SPECIFY CLOTHES DRYER EXHAUST AS REQUIRED BY SEC.
 M1502 FBC-RESIDENTIAL.
  
 *** PLEASE PROVIDE RESPONSE LETTER ADDRESING EACH
 COMMENT TO HELP EXPEDITE THE REVIEW PROCESS.
 **** PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT ALL DRAWINGS
 FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2018-03-07 Cont ID  
Sent By gjohnson Date 2018-03-07 Time 12:12 Rev Time 0.00
Received By gjohnson Date 2018-03-07 Time 12:12 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-11-03 Cont ID  
Sent By gjohnson Date 2017-11-03 Time 10:24 Rev Time 0.00
Received By gjohnson Date 2017-11-03 Time 09:59 Sent To  
Notes
2017-11-03 10:38:181ST REVIEW: FBC 2014 5TH EDITION
  
 PLUMBING COMMENTS:
  
 1. SHT P-1 NOTE #15 AIR CHAMBERS ARE NOT CODE COMPLIANT
 YOU SHALL USE WATER HAMMER ARRESTORS SHALL CONFORM TO
 ASSE 1010. PER FBC ACC P2903.5
  
 2. THE WATER CLOSET IN BATHROOM 1 IS NOTE VENTED, THE
 TUB, WATER CLOSET AND LAVATORY SHOULD BE VENTED
 TOGETHER AS A WET VENT AND THEN CONNECTED TO BUILDING
 DRAIN. PER FBC RES P3108.1
  
 3. PLEASE SHOW LOCATION AND TYPE OF WATER HEATER. PER
 WPB AMEND TO FBC 107.2.1
  
 4. PROVIDE DETAIL FOR WATER HEATER PIPING. PER WPB
 AMEND TO FBC 107.2.1
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2018-04-11 Cont ID  
Sent By aclange Date 2018-04-11 Time 14:31 Rev Time 0.00
Received By aclange Date 2018-04-11 Time 14:31 Sent To  
Notes
2018-04-11 14:31:45RECEIVED ROOFING SUBCONTRACTOR APPLICATION.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2018-03-08 Cont ID  
Sent By jgomez Date 2018-03-08 Time 18:44 Rev Time 0.00
Received By jgomez Date 2018-03-08 Time 18:44 Sent To  
Notes
2018-03-08 18:48:041- PROVIDE PRODUCT APPROVAL (TWO COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 A) BALCONY UNDERLAYMENT SPECIFIED ON PLANS. NOTE: NEED
 PRODUCT APPROVAL THAT IS DESIGNED TO RECEIVE TILE AS
 SPECIFIED ON PLANS. CLEARLY IDENTIFY SPECIFIC ASSEMBLY
 TO BE USED. IF SELECTED ASSEMBLY DOESN'T MEET THE
 DESIGN PRESSURES FOR ALL ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS WILL BE REQUIRED.
 RESPONSE: KEMPEROL MEMBRANE WATERPROOFING SYSTEM
 SUBMITTED IS FOR CONCRETE DECKS. THIS IS A WOOD DECK.
 PROVIDE PROPER PRODUCT APPROVAL. AND IDENTIFY SELECTED
 ASSEMBLY AS REQUESTED ABOVE.
  
  
 APPROVED PRODUCT APPROVALS;
 A) 5V METAL ROOF NOA 13-0627.02
 B) METAL ROOF UNDERLAYMENT NOA 16-0322.26

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2017-11-13 Cont ID  
Sent By jgomez Date 2017-11-13 Time 15:49 Rev Time 0.00
Received By jgomez Date 2017-11-13 Time 15:48 Sent To I
Notes
2017-11-08 17:53:551- IT IS NOT CLEAR WHAT TYPE OF ROOFING MATERIAL IS
 GOING TO BE USED. PLANS CALL FOR METAL ROOFING, WHILE
 PRODUCT APPROVAL SUBMITTED IS FOR SHINGLES. REVISE AS
 REQUIRED TO MATCH. SEC. 107.2.1 CITY AMENDMENTS.
  
 2- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 A) ROOF MATERIAL TO BE USED. COORDINATE WITH ITEM #1
 ABOVE TO AVOID CONFLICTS/DELAYS.
  
 B) IF USING SHINGLES, THEN THE RIDGE CAP SHINGLES NOA
 13-0306.08 SUBMITTED EXPIRED ON 10/17/17. PROVIDE
 CURRENT NOA.
  
 C) BALCONY UNDERLAYMENT SPECIFIED ON PLANS. NOTE: NEED
 PRODUCT APPROVAL THAT IS DESIGNED TO RECEIVE TILE AS
 SPECIFIED ON PLANS. CLEARLY IDENTIFY SPECIFIC ASSEMBLY
 TO BE USED. IF SELECTED ASSEMBLY DOESN'T MEET THE
 DESIGN PRESSURES FOR ALL ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS WILL BE REQUIRED.
  
 3- DESIGNER OF RECORD TO APPROVE ABOVE PRODUCT
 APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY
 AMENDMENTS.
  

Review Stop Z ZONING
Rev No 3 Status P Date 2018-04-06 Cont ID  
Sent By destabro Date 2018-04-06 Time 15:43 Rev Time 0.00
Received By destabro Date 2018-04-06 Time 15:43 Sent To B
Notes
2018-04-06 15:44:404/6/2018 - SAME FEBRUARY 2018 CONDITION APPLIES TO
 CURRENT APPROVAL, AND REPRODUCED HERE: 3' SIDE SETBACK
 MET - GRAVEL CAN ONLY BE USED AS A DRIVEWAY MATERIAL
 AFTER THE 25' FRONT SETBACK, DRIVEWAY CURB CUT AND
 INTIIAL 25' MUST BE BRICK PAVER OR CONCRETE MATERIAL.
 DLE

Review Stop Z ZONING
Rev No 2 Status P Date 2018-02-15 Cont ID  
Sent By destabro Date 2018-02-15 Time 15:37 Rev Time 0.00
Received By destabro Date 2018-02-15 Time 15:37 Sent To HIST
Notes
2018-02-15 15:38:302/15/18 - 3' SIDE SETBACK MET - GRAVEL CAN ONLY BE USED
 AS A DRIVEWAY MATERIAL AFTER THE 25' FRONT SETBACK,
 DRIVEWAY CURB CUT AND INTIIAL 25' MUST BE BRICK PAVER
 OR CONCRETE MATERIAL. DLE

Review Stop Z ZONING
Rev No 1 Status F Date 2017-10-26 Cont ID  
Sent By destabro Date 2017-10-26 Time 13:47 Rev Time 0.00
Received By destabro Date 2017-10-26 Time 14:09 Sent To B
Notes
2017-10-26 13:48:5810/26/17 - MEETS REQUIRED SETBACKS AND FAR/LOT COVERAGE
 REQUIREMENTS PER THE ZONING AND LAND DEVELOPMENT
 REGULATIONS. HOWEVER, DRIVEWAY MUST MAINTAIN 3'
 SEPARATION BETWEEN DRIVEWAY AND SIDE PROPERTY LINE.
 ADDITIONALLY, DRIVEWAY MATERIAL MUST BE A NON-DUSTING
 SURFACE (PAVER, BRICK OR CONCRETE). GRAVEL FILL IS NOT
 PERMITTED. PLEASE DIRECT QUESTIONS TO DESIREE
 ESTABROOK, HISTORIC PRESERVATION PLANNER, AT
 561.822.1428.