| Plan Review Stops For Permit 17100260 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-01-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-01-22 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-01-22 |
Time |
14:08 |
Sent To |
I |
|
| Notes |
| 2018-01-22 14:19:52 | ****PROVISO**** | | | ****ISSUED AT APPLICANT'S RISK**** | | | ****ROLLUP DOORS NOT ACCEPTED AS "ACCESSIBLE" AT THIS | | | TIME DUE TO LACK OF INFORMATION**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | REVISION REQUIRED; PROVIDE DETAILS TO SHOW COMPLIANCE | | | WITH FBC A 404. ROLLUP DOORS ARE PROPOSED AS ACCESSIBLE | | | DOORS; IT IS NOT CLEAR HOW THEY MEET ALL REQUIREMENTS | | | OF FBC A 404. | | | | | | SOME INFORMATION WAS PROVIDED, BUT SPEC SHEET REFERS TO | | | "ADA CODE" AND SECTIONS WHICH DO NOT CORRELATE WITH THE | | | FLORIDA BUILDING CODE. THIS INFORMATION IS REQUIRED FOR | | | CONSIDERATION BY THE BUILDING OFFICIAL. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-01-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-01-10 |
Time |
06:11 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-01-05 |
Time |
12:53 |
Sent To |
I |
|
| Notes |
| 2018-01-10 06:13:29 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE 2014 | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. FBC A TABLE 225, REVISE PLAN TO NOTE ACCESSIBILITY | | | REQUIREMENT. | | | | | | 2ND REVIEW, THE SHOP DRAWINGS SUBMITTED FOR THE STORAGE | | | UNITS HAVE ROLLUP DOORS. IT IS NOT CLEAR HOW COMPLIANCE | | | WITH FBC A TABLE 225.3 HAS BEEN MET. | | | | | | PROVIDE THE TOTAL NUMBER OF UNITS, NUMBER OF ACCESSIBLE | | | UNITS, AND A DETAIL FOR ACCESSIBLE UNITS. | | | | | | 2. SEE MECHANICAL COMMENTS; ENERGY CALCS REQUIRED, | | | BUILDING REVIEW REQUIRED FOR BUILDING COMPONENTS OF | | | ENERGY CALCS. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-10-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-10-16 |
Time |
11:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-10-16 |
Time |
11:44 |
Sent To |
|
|
| Notes |
| 2017-10-16 11:45:03 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE 2014 | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. FBC A TABLE 225, REVISE PLAN TO NOTE ACCESSIBILITY | | | REQUIREMENT. | | | | | | 2. THIS PROPERTY (1016 CLARE AVE) IS A CONDOMINIUM. | | | DECLARATION OF CONDOMIUM ON WWW.MYPALMBEACHCLERK.COM | | | PROPERTY UNIT BOUNDARIES. REVISE PLAN TO SHOW LIMITS OF | | | EACH CONDOMINIUM UNIT, FBC 107. | | | | | | 3. PERMIT 17040927, WHICH APPEARS TO HAVE THE SAME | | | SCOPE OF WORK AS EXPIRED REVISION 17021087, ASSOCIATED | | | WITH EXPIRED PERMIT 14100520. THIS ADDRESS HAS SEVERAL | | | OTHER EXPIRED PERMITS, PLEASE RESOLVE AT THIS TIME. | | | | | | 4. REVISE PLAN TO INCLUDE EXISTING OCCUPANCY | | | CLASSIFICATION OF THIS SPACE, FBC 107. IF THIS IS A | | | CHANGE OF OCCUPANCY, REVISE PLAN TO SHOW COMPLIANCE | | | WITH FBC EB CHAPTER 10. | | | | | | 5. DUE TO A PREVIOUS CHANGE OF OCCUPANCY (12030117) AND | | | COMPLIANCE WITH FBC B TABLE 503, ALL OCCUPANCIES | | | REQUIRED TO BE SEPARATED PER FBC B 508.4. REVISE PLAN | | | TO SHOW ALL REQUIRED FIRE RATED WALLS AND RATINGS. | | | | | | 6. PERMIT 12030117, THIS BUILDING WAS DECLARED AS A | | | TYPE IIA BUILDING. EITHER REVISE PLAN OR, IF BUILDING | | | TYPE IS TO BE REDUCED TO IIIB (AS PER SHEET CS1), | | | REVISE PLAN TO SHOW COMPLIANCE WITH FBC B TABLE 503. | | | | | | 7. AS EXISTING USE NOT CLEAR, I CANNOT DETERMINE | | | WHETHER OR NOT IMPACT FEE ASSESSMENT IS REQUIRED. IT IS | | | POSSIBLE THAT, AFTER ALL PLAN REVIEWS HAVE BEEN PASSED, | | | AN IMPACT FEE REVIEW BY PALM BEACH COUNTY WILL BE | | | REQUIRED. THE PLANS ARE TO BE STAMPED AND A RECEIPT | | | SHOWING THAT FEES DUE, IF APPLICABLE, WERE PAID ARE | | | REQUIRED TO BE PROVIDED PRIOR TO PERMIT ISSUANCE. | | | | | | 8. AN "ELEVATOR DOOR OPENING DETAIL" IS ON SHEET A1. | | | CLARIFY LOCATION, CLARIFY NAME FBC 107. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2017-10-20 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-10-20 |
Time |
17:18 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-10-20 |
Time |
17:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-12-15 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-12-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-12-15 |
Time |
09:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2017-10-12 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-10-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-10-11 |
Time |
10:26 |
Sent To |
|
|
| Notes |
| 2017-10-12 14:16:22 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | | | | 1) SHEET CS 1 & A 1 - THERE APPEARS TO BE EXISTING | | | CONSTRUCTION INFILL OF 5 OVERHEAD DOOR OPENINGS. PER | | | NFPA 101 THERE IS A REQUIRED FIRE RATING SEPARATION OF | | | STORAGE OCCUPANCIES AND ADJACENT OCCUPANCIES. THE | | | ADJACENT OCCUPANCY IS NOT INDICATED TO DETERMINE WHAT | | | IS REQUIRED AND WHAT THE CURRENT FATING OF THE EXISTING | | | WALL IS. | | | | | | PLEASE INDICATE THE ADJACENT OCCUPANCY AND PROVIDE THE | | | REQUIRE SEPARATION AND WHAT LISTING WAS USED FOR THOS | | | OPENINGS. | | | | | | | | | | | | 2) SHEET A 1 - THERE IS NO DETAIL INDICATED FOR THE | | | STORAGE UNITS, THOUGH IT IS INDICATED BY OTHERS. | | | | | | PLEASE PROVIDE WHAT TYPE OF MATERIALS WILL BE USED TO | | | CONSTRUCT THESE UNITS, WALL HEIGHTS, ROOF COVERINGS, | | | DIMESIONS, ETC. | | | | | | | | | | | | 3) SHEET A 1 - THE STORAGE UNITS BY OTHERS SHALL BE | | | UNDER SEPARATE PLAN SUBMITTAL. | | | | | | PLEASE PROVIDE AN APPLICABLE NOTE OF ACKNOWLEGEMENT. | | | | | | | | | | | | 4) SHEET A 1 - THERE ARE NO DIMENSIONS FOR ANY | | | CORRIDOR. | | | | | | PLEASE PROVIDE ALL APPLICABLE DIMENSIONS ALL CORRIDORS. | | | | | | | | | | | | 5) SHEET A 1 - THERE APPEARS TO BE AN END WALL ON THE | | | EAST SIDE OF THE PROPOSED PROJECT. THE WALL IS NOT | | | INDICATED AS EXISTING OR NEW AND IS NOT RATED. THE | | | ADJACENT OCCUPANCY IS NOT INDICATED. | | | | | | PLEASE PROVIDE SPECIFIC DETAIL ON THIS WALL INCLUDING | | | THE REQUIRED FIRE RATING, THE APPLICABLE LISTING AND | | | THE ADJACENT OCCUPANCY. | | | | | | | | | | | | 6) SHEET A 1 - THERE IS NO DOOR SCHEDULE. THOUGH THE | | | DOORS MAY BE EXISITNG EACH ONE SHALL BE IDENTIFIED WITH | | | TYPE AND AMATERIAL INCLUDING HARDWARE, CLOSERS, ETC. | | | | | | PLEASE PROVIDE A DETAILED DOOR SCHEDULE. | | | | | | | | | | | | 7) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | 8) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-01-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-01-22 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-01-12 |
Time |
14:09 |
Sent To |
|
|
| Notes |
| 2018-01-16 14:10:08 | RESUB ROUTED TO CCOLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-01-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-01-10 |
Time |
06:13 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-12-13 |
Time |
13:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-10-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-10-06 |
Time |
15:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2018-01-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-01-05 |
Time |
17:52 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-01-05 |
Time |
17:52 |
Sent To |
|
|
| Notes |
| 2018-01-05 17:52:33 | PLAN STAMPED, NO FEES DUE | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2017-10-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-10-16 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-10-16 |
Time |
10:47 |
Sent To |
|
|
| Notes |
| 2017-10-16 10:47:29 | SEE BUILDING REVIEW | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2018-01-17 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-01-17 |
Time |
17:28 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-01-17 |
Time |
17:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2017-12-27 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-12-27 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-12-27 |
Time |
07:25 |
Sent To |
|
|
| Notes |
| 2017-12-27 08:37:39 | 1ST REVIEW FBC-2014 MECHANICAL, ENERGY CONSERVATION | | | PERMIT #17100260 | | | 12/27/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) 2ND REQUEST FOR AN ENERGY COMPLIANCE SUBMITTAL. | | | | | | 2) THE AC CALCULATIONS INDICATE THE 3.5 TON SYSTEMS ARE | | | OVERSIZED- SECTION C403.2.2 FBC-14 ENERGY CONSERVATION. | | | | | | 3) M-1: INDICATE THE TYPE OF OUTDOOR AIR DUCTWORK TO BE | | | INSTALLED PER SECTION 603. THE PLAN IS INDICATING AN 8" | | | PIPE. | | | | | | 4) M-1: PROVIDE AN AIR HANDLER INSTALLATION DETAIL- | | | SECTION 304.1. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-10-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-10-24 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-10-24 |
Time |
16:24 |
Sent To |
|
|
| Notes |
| 2017-10-24 16:54:43 | 1ST REVIEW FBC-2014 MECHANICAL, ENERGY CONSERVATION, | | | EXISTING BUILDING CODES. | | | PERMIT #17100260 | | | 10/24/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | THE PROPOSED PROJECT INCLUDES ADDING NEW AC SYSTEMS TO | | | DEAD STORAGE SPACE. THESE NEW SYSTEMS ARE NOT | | | "CHANGE-OUTS" CONTRARY TO THE ARCHITECT'S NOTE ON SHEET | | | A-1. THERE ARE NO BUILDING DEPARTMENT RECORDS OF ANY | | | LEGALLY PERMITTED AC SYSTEMS IN THE SPACE. MECHANICAL | | | PLANS ARE REQUIRED WITH THIS SUBMITTAL- SEE COMMENTS | | | BELOW. | | | | | | 1) THE PREVIOUSLY UNCONDITIONED STORAGE SPACE NOW BEING | | | CONDITIONED SHALL BE BROUGHT INTO FULL COMPLIANCE WITH | | | THE FBC-14 ENERGY CONSERVATION CODE- SEE SECTION | | | C101.4.5. PLEASE PROVIDE AN ENERGY COMPLIANCE SUBMITTAL | | | USING ONE OF THE METHODS LISTED UNDER SECTION C401.2. | | | | | | 2) PROVIDE COOLING AND HEATING CALCULATIONS FOR THE NEW | | | AC SYSTEM- SECTION C403.2.1 FBC-14 ENERGY CONSERVATION. | | | | | | 3) INDICATE HOW FRESH AIR WILL BE PROVIDED TO THE SPACE | | | USING EITHER NATURAL OR MECHANICAL VENTILATION- SEE | | | SECTIONS 402 AND 403 AND PROVIDE CALCULATIONS. | | | | | | 4) IF MECHANICAL VENTILATION IS TO BE PROVIDED, SHOW | | | THE LOCATIONS OF THE O/A DUCTS AND PROVIDE DETAILS- | | | TYPES AND SIZES OF DUCTS, INLET LOCATIONS AND CLEARANCE | | | DISTANCES, TYPES OF SHUTOFF DAMPERS AND LOCATIONS. | | | | | | 5) PROVIDE AC LAYOUT PLANS INCLUDING A DUCT LAYOUT AND | | | EQUIPMENT SCHEDULES. SHOW THE CFMS AT EACH SUPPLY | | | DIFFUSER AND RETURN GRILL. | | | | | | 6) PROVIDE AN AIR DISTRIBUTION SCHEDULE. | | | | | | 7) PROVIDE CONDENSATE DISPOSAL PLANS. | | | | | | 8) PROVIDE WIND LOAD ENGINEERING FOR CONSTRUCTION OF | | | THE CONDENSER PADS AND TIE DOWN OF THE CONDENSERS TO | | | THE PADS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
N |
Date |
2017-10-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-10-16 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-10-16 |
Time |
10:46 |
Sent To |
|
|
| Notes |
| 2017-10-16 10:46:57 | PAPA VALUE $4,652,997; CUMULATIVE 5 YEAR IMPROVEMENTS | | | $720,453 | | | NOT A SUBSTANTIAL IMPROVEMENT | | | | | | |
|
|