Plan Review Details - Permit 17090753
Plan Review Stops For Permit 17090753
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2018-01-12 Cont ID  
Sent By shill Date 2018-01-12 Time 05:56 Rev Time 0.00
Received By shill Date 2018-01-12 Time 05:56 Sent To  
Notes
***NONE***

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2017-11-06 Cont ID  
Sent By shill Date 2017-11-06 Time 08:23 Rev Time 0.00
Received By shill Date 2017-11-06 Time 08:23 Sent To  
Notes
2017-11-06 08:23:38LOT C, 241 EDMOR RD,
 PCN: 74-43-44-03-28-000-0030
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-01-03 Cont ID  
Sent By cthroop Date 2018-01-03 Time 13:50 Rev Time 0.00
Received By cthroop Date 2018-01-03 Time 13:27 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-11-06 Cont ID  
Sent By cthroop Date 2017-11-06 Time 16:37 Rev Time 0.00
Received By cthroop Date 2017-10-30 Time 11:41 Sent To M
Notes
2017-11-06 17:09:30BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. SOILS REPORT - PROVIDE SITE PLAN INDICATING THE
 LOCATION OF BORINGS.
 2. SOILS REPORT TO BE SIGNED AND SEALED BY STATE OF
 FLORIDA LICENSED PROFESSIONAL ENGINEER.
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN
 UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE
 OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT
 IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 THE CONSTRUCTION DOCUMENTS SHALL BE PREPARED BY A
 REGISTERED DESIGN PROFESSIONAL WHERE REQUIRED BY
 CHAPTER 471, FLORIDA STATUTES& 61G15 FLORIDA
 ADMINISTRATIVE CODE OR CHAPTER 481, FLORIDA STATUTES&
 61G1 FLORIDA ADMINISTRATIVE CODE.
  
 3. BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT
 FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID.
 UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE
 SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN
 IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP
 AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE
 CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN
 BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY
 IMPACT FEES AT (561) 233-5025.
  
 4. DESIGN PROFESSIONALS SIGNATURE AND SEAL ON PLANS ARE
 PHOTOCOPIED.
 FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO
 SECTION 107.3.5) AND F.S. 481.229.
  
 5. NEW CONSTRUCTION NOTES ON PLAN PAGE A-301 SPECIFIES
 STRUCTURE AS AN R-2. THIS IS A SINGLE FAMILY
 RESIDENTIAL STRUCTURE AND SHOULD BE CLASSIFIED AS AN
 R-3. PLEASE CORRECT.
  
 6. IDENTIFY LOCATION OF ATTIC ACCESSES ON PLANS.
  
 7. ENERGY SUBMITTAL - THE SUBMITTAL HAS NUMEROUS
 ERRONEOUS VALUES.
 7A. ITEM #8 - NO R- VALUE GIVEN FOR FLOOR AREA BETWEEN
 1ST AND 2ND FLOORS.
 7B. ROOFING MATERIAL INDICATES THE INSTALLATION OF
 BARREL TILE. SUBMITTED PLANS SPECIFY METAL ROOF. PLEASE
 CLARIFY.
 7C. THE VENT RATIO STATED ON PAGE 2 OF 5 STATES A RATIO
 OF 1/300. TYPICAL VENT RATIO IS 1/150. PLEASE CLARIFY.
 7D. BUILDER NAME IS MISSING ON COVER PAGE.
 7E. PLEASE RE-VISIT THE VALUES FOR CEILINGS, WALLS,
 DOORS AND WINDOWS ON PAGE 3 OF 5.
  
 8. STUCCO THICKNESS ON WALL SECTIONS INDICATES 5/8"
 THICKNESS. STUCCO REQUIREMENT IS 7/8" THICK IN THESE
 AREAS PER TABLE R702.1 (1). PLEASE CORRECT.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED AND MARK VOID.
 ADDITIONAL COMMENTS MAY BE MADE UPON RE-SUBMITTAL.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-12-13 Cont ID  
Sent By jpearson Date 2017-12-13 Time 15:45 Rev Time 0.00
Received By jpearson Date 2017-12-13 Time 15:45 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-10-26 Cont ID  
Sent By jpearson Date 2017-10-26 Time 12:44 Rev Time 0.00
Received By jpearson Date 2017-10-26 Time 12:44 Sent To  
Notes
2017-10-26 12:44:16CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION,
 PART VIII ELECTRICAL
 NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. SERVICE CONDUCTORS FROM METER CAN TO MCB PANELS IS
 SHOWN AS # 1 WIRE TO A 150 AMP MAIN BREAKER. WIRE SIZES
 FROM NEC 310.15(B)(7), OR FBC RE TABLE E3603.1, CAN
 ONLY BE USED WHEN THE SERVICE CONDUCTOR SUPPLIES 100%
 OF THE LOAD. SINCE THIS IS NOT THE CASE, PROVIDE
 CORRECTED WIRE SIZE FROM METER CAN TO PANELS. NEC
 310.15(B)(7) AND (B)(15); FBC RE TABLE E3601.3
 2. SERVICE CONDUCTORS FROM THE METER CAN TO THE MCB
 PANELS SHOULD NOT INCLUDE AN EQUIPMENT GROUNDING
 CONDUCTOR. PROVIDE CORRECTION. NEC 250.122; FBC RE 3607
 3. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT
 SERVICE. NEC 250.94; FBC RE3609.3
 4. CLARIFICATION REQUIRED FOR THE GROUNDING ELECTRODE
 CONDUCTOR (GEC) SIZE. IF THE GEC IS ATTACHED TO THE CWP
 AS SHOWN, THEN IT IS TOO SMALL, ASSUMING THE SIZE OF
 SERVICE CONDUCTOR FROM FPL IS RATED FOR 300 AMPS. IF
 THERE IS NOT 10 FEET OF BURIED METAL CWP, THEN THE
 CURRENT SIZE IS ADEQUATE TO THE FOOTER STEEL AND GROUND
 RODS. IN THIS CASE, REMOVE THE CWP REFERENCE ON THE
 RISER DIAGRAM GROUNDING. NEC 250.52; FBC RE 3608.1
 5. SHOW LOCATION OF SERVICE AND ELECTRICAL PANELS ON
 PLAN. HOW FAR FROM THE METER CAN IS THE LOCATION OF THE
 PANELS? SERVICE ENTRANCE CONDUCTORS WITHOUT AN
 OVERCURRENT PROTECTION SHALL NOT BE PERMITTED TO BE RUN
 INSIDE THE BUILDING MORE THAN 8 FEET. EACH OF THE MAIN
 CIRCUIT BREAKERS ARE REQUIRED TO BE IN SAME LOCATION
 (GROUPED). FBC 107.2.1; NEC 230.72
 6. FOR POOL PANEL, DEMAND FACTORS CANNOT BE USED. THE
 DEMAND FACTORS ARE ONLY FOR FEEDERS RATED 100 AMPS OR
 GREATER. SIZE WIRING AND OVERCURRENT PROTECTION FOR THE
 LOAD OF THE PANEL. PROVIDE CORRECTION. NEC 220.82; FBC
 RE 3702.1
 7. BREAKER FOR POOL PUMP IS REQUIRED TO BE GFCI
 PROTECTED. NEC 680.21(C); FBC RE 4203.1.3
 8. PANEL A, CIRCUIT 1,3 SHOWS A # 6 ROMEX WIRE ON A 60
 AMP BREAKER. #6 ROMEX WIRE IS NOT RATED FOR 60 AMPS.
 PROVIDE CORRECTION. NEC 334.80; FBC RE3705.4.4
 9. WATER HEATER IS SHOWN ON ELECTRICAL PLAN, BUT THERE
 IS NO LOAD INCLUDED FOR LOAD CALCULATION OR CIRCUIT
 SHOWN FOR WATER HEATER. THERE IS ALSO NO PLUMBING PLAN
 PROVIDED TO VERIFY THE TYPE OF WATER HEATER. PROVIDE
 CORRECTION. NEC 220; FBC 107.2.1
 10. NOTE 21 OF ELECTRICAL NOTES STATES THAT RECEPTACLES
 SHALL BE TAMPER RESISTANT PER NEC 2008, 406.11. THIS IS
 NOT THE CURRENT CODE OR CORRECT CODE SECTION. PROVIDE
 CORRECTION. NEC 406.12; FBC RE4002.14
 11. PROVIDE GFCI PROTECTION FOR ALL OUTLETS IN GARAGE,
 INCLUDING GARAGE DOOR OPENER.. NEC 210.8; FBC RE3902.2
 12. PROVIDE GFCI PROTECTION FOR OUTLET BY AC EQUIPMENT.
 NEC 210.8; FBC RE3902.3
 13. MASTER AND GUEST BATH SHOW A CHANDELIER OVER THE
 TUB. NO PARTS OF CORD-CONNECTED LUMINAIRES, CHAIN-,
 CABLE-, OR CORD-SUSPENDED LUMINAIRES, LIGHTING TRACK,
 PENDANTS, OR CEILING-SUSPENDED (PADDLE) FANS SHALL BE
 LOCATED WITHIN A ZONE MEASURED 3 FEET HORIZONTALLY AND
 8 FEET VERTICALLY FROM THE TOP OF THE BATHTUB RIM OR
 SHOWER STALL THRESHOLD. PROVIDE CORRECTION. NEC
 410.10(D); FBC RE 4003.11
 14. MASTER BATH, PROVIDE A GFCI PROTECTED OUTLET ON A
 20 AMP CIRCUIT WITHIN 3 FEET OF EACH BASIN. PROVIDE
 CORRECTION. NEC 210.11(C)(3), 210.52(D); FBC RE 3703.4,
 3901.6
 15. ALL WALK IN CLOSETS SHOW STANDARD RECESS LIGHTS
 WITH LED. PER CODE: "LIGHTING WITH OPEN OR PARTIALLY
 ENCLOSED LAMPS AND PENDANT LUMINAIRES OR LAMPHOLDERS
 SHALL NOT BE PERMITTED IN CLOTHES CLOSETS". PROVIDE
 CORRECTION. NEC 410.16; FBC RE4003.12
 16. ELECTRICAL SHEETS ARE NOT SIGNED OR SEALED. PER THE
 WPB AMENDMENTS TO THE FBC, PLAN IS REQUIRED TO BEAR THE
 NAME AND BE SIGNED AND SEALED BY THE PERSON RESPONSIBLE
 FOR THE DESIGN. PROVIDE CORRECTION. FBC 107.2.1, FS
 471, 481
 17. PROVIDE GFCI PROTECTED OUTLET ON THE KITCHEN
 ISLAND. NEC 210.8, 210.52(C)(2); FBC RE 3901.4.2
 18. PROVIDE A BLOCK NOTE INDICATING THE REQUIRED
 SEPARATE PERMITS AND DATA SPECIFICATION SHEET
 SUBMITTALS FOR LOW VOLTAGE SYSTEMS AND POOL. FBC 105.1,
 107.2.1
 19. PROVIDE COMPLIANCE: "A MINIMUM OF 75 PERCENT OF THE
 LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF
 THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 CONTAIN ONLY HIGH EFFICACY LAMPS". A NOTE WILL SUFFICE.
 FBC CE R404.1
 20. SECOND FLOOR PLAN, AT TOP OF STAIRS AND IN HALLWAY,
 A REGULAR SMOKE ALARM IS SHOWN. PROVIDE CARBON MONOXIDE
 ALARMS WITHIN 10 FEET OF EACH ROOM USED FOR SLEEPING
 PURPOSES. FBC R315.1
 21. SMOKE ALARMS IN SEVERAL LOCATION ARE SHOWN WITHIN 3
 FEET OF A CEILING FAN. PER THE FIRE CODE, SMOKE ALARMS
 SHALL BE AT LEAST 3 FEET FROM CEILING FANS OR
 MECHANICAL GRILLS. PROVIDE CORRECTION. NFPA 72;
 29.8.3.4, AND 6, AND 7
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By lmarchan Date 2018-01-25 Time 13:59 Sent To  
Notes
2018-01-26 13:59:41RESUB ROUTED TO AWOOTEN VIA ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-01-23 Cont ID  
Sent By cthroop Date 2018-01-23 Time 14:36 Rev Time 0.00
Received By cthroop Date 2018-01-19 Time 18:50 Sent To I
Notes
2018-01-22 18:51:00CTHROOP'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-01-03 Cont ID  
Sent By cthroop Date 2018-01-03 Time 13:50 Rev Time 0.00
Received By cthroop Date 2017-11-28 Time 15:20 Sent To I
Notes
2017-11-29 15:20:14R32

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-11-13 Cont ID  
Sent By hmoser Date 2017-11-13 Time 09:57 Rev Time 0.00
Received By hmoser Date 2017-09-28 Time 10:23 Sent To  
Notes
2017-09-29 10:23:49R05

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2018-01-23 Cont ID  
Sent By cthroop Date 2018-01-23 Time 14:34 Rev Time 0.00
Received By cthroop Date 2018-01-23 Time 12:56 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2017-11-06 Cont ID  
Sent By cthroop Date 2017-11-06 Time 15:46 Rev Time 0.00
Received By cthroop Date 2017-10-30 Time 11:41 Sent To  
Notes
2017-11-06 15:47:37BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT
 FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID.
 UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE
 SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN
 IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP
 AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE
 CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN
 BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY
 IMPACT FEES AT (561) 233-5025.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2017-12-19 Cont ID  
Sent By hmoser Date 2017-12-19 Time 10:02 Rev Time 0.00
Received By hmoser Date 2017-12-19 Time 09:17 Sent To  
Notes
2017-12-19 10:02:39PASS PROVISO
 1) NEED EXHAUST FAN FOR MASTER BATHROOM
 PER SECTION 1507.4 EXHAUST RATES.
 2014 RESIDENTIAL CODE
 2) REFER TO SECTION 1602.4 BALANCED
 RETURN AIR EXCEPTION # 1 2014 RESIDENTIAL CODE
 2014. MASTER BEDROOM
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676
  
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-11-13 Cont ID  
Sent By hmoser Date 2017-11-13 Time 09:57 Rev Time 0.00
Received By hmoser Date 2017-11-08 Time 10:20 Sent To I
Notes
2017-11-13 09:57:23PLAN DENIED
 1) PLEASE MARK ON PLAN WITCH A/C UNIT
 IS # 1 AND 2 PER SECTION 107 FBC
 2) REFER TO SECTION M 1602.4 BALANCED RETURN AIR
 FOR MASTER BEDROOM 1ST. FLOOR 2014 RESIDENTIAL CODE
 3) REFER TO SECTION M 1507.4 EXHAUST RATES. NEED
 EXHAUST FAN IN MASTER BATH NOT IN TOLIT ROOM. 2014
 RESIDENTIAL CODE.
 4) PROVIDE COMPLETE ADDRESS ON PLANS.
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-12-28 Cont ID  
Sent By tklarge Date 2017-12-28 Time 05:42 Rev Time 0.00
Received By tklarge Date 2017-12-28 Time 05:34 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2017-10-11 Cont ID  
Sent By thunt Date 2017-10-11 Time 16:25 Rev Time 0.00
Received By thunt Date 2017-10-11 Time 16:25 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2018-01-03 Cont ID  
Sent By cthroop Date 2018-01-03 Time 13:50 Rev Time 0.00
Received By cthroop Date 2018-01-03 Time 13:27 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2017-11-06 Cont ID  
Sent By cthroop Date 2017-11-06 Time 16:37 Rev Time 0.00
Received By cthroop Date 2017-10-30 Time 15:40 Sent To  
Notes
2017-11-06 16:40:40BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. NOA NO. 12-0703.06 MODIFIED BITUMEN SUBMITTED FOR
 2ND FLOOR BALCONY IS FOR WOOD DECK APPLICATIONS.
 2. PROVIDE NOA FOR CONCRETE DECKS.
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN
 UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE
 OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT
 IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING SUBMITTALS.
  
  

Review Stop Z ZONING
Rev No 3 Status P Date 2018-02-02 Cont ID  
Sent By AW Date 2018-02-02 Time 09:36 Rev Time 0.00
Received By awooten Date 2018-01-31 Time 13:36 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date   Cont ID  
Sent By AW Date   Time   Rev Time 0.00
Received By   Date 2017-12-29 Time   Sent To B
Notes
2018-01-02 15:56:52*********************************ZONING REVIEW
 FAILED***********************************************
  
 LANDSCAPING:
 GENERAL LANDSCAPING STANDARDS FOR SINGLE-FAMILY
 DWELLING UNITS SHALL BE AS FOLLOWS:
 A. SINGLE-FAMILY DWELLING UNITS. FOR SINGLE-FAMILY
 DWELLING UNITS, AT LEAST ONE SHADE, FLOWERING OR FRUIT
 TREE SHALL BE PLANTED FOR EACH 1,200 SQUARE FEET OF
 OPEN SPACE OR PORTION THEREOF. FOR SINGLE-FAMILY
 DWELLING UNITS, AT LEAST ONE SHRUB SHALL BE PLANTED FOR
 EACH 500 SQUARE FEET OF OPEN SPACE OR PORTION THEREOF.
 B. PLEASE SUBMIT A SEPARATE LANDSCAPE PERMIT AND
 IRRIGATION PLAN WITH TWO (2) COPIES OF A LANDSCAPE PLAN
 SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF
 THE ZLDR.
  
 ALANA WOOTEN
 ASSOCIATE PLANNER
 PLANNING DIVISION
 561-822-1449
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 2017-10-25 Cont ID  
Sent By   Date 2017-10-25 Time   Rev Time  
Received By   Date 2017-10-25 Time   Sent To  
Notes
2017-10-25 14:18:42*****ZONING REVIEW FAILED********
  
 SETBACK ENCROACHMENTS:
 STRUCTURAL INTRUSIONS. STRUCTURAL OVERHANGS, INCLUDING
 BUT NOT LIMITED TO BALCONIES, CORNICES, GUTTERS, EAVES,
 AND ROOF OVERHANG PROJECTIONS SHALL NOT EXTEND FARTHER
 THAN THREE FEET INTO ANY SETBACK.
  
 LANDSCAPING:
 GENERAL LANDSCAPING STANDARDS FOR SINGLE-FAMILY
 DWELLING UNITS SHALL BE AS FOLLOWS:
 A. SINGLE-FAMILY DWELLING UNITS. FOR SINGLE-FAMILY
 DWELLING UNITS, AT LEAST ONE SHADE, FLOWERING OR FRUIT
 TREE SHALL BE PLANTED FOR EACH 1,200 SQUARE FEET OF
 OPEN SPACE OR PORTION THEREOF. FOR SINGLE-FAMILY
 DWELLING UNITS, AT LEAST ONE SHRUB SHALL BE PLANTED FOR
 EACH 500 SQUARE FEET OF OPEN SPACE OR PORTION THEREOF.
 B. PLEASE SUBMIT A SEPARATE LANDSCAPE PERMIT AND
 IRRIGATION PLAN WITH TWO (2) COPIES OF A LANDSCAPE PLAN
 SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF
 THE ZLDR.
  
 MECHANICAL EQUIPMENT:
 MECHANICAL EQUIPMENT MAY NOT PROJECT MORE THAN FOUR
 FEET INTO A SETBACK. WINDOW AIR-CONDITIONING UNITS MAY
 NOT PROJECT MORE THAN 18 INCHES INTO A REQUIRED SIDE
 SETBACK.
  
 DRIVEWAY REQUIRES A SEPARATE PERMIT.
  
 PLEASE LET ME KNOW IF YOU HAVE ANY QUESTIONS.
  
 ALANA WOOTEN
 ASSOCIATE PLANNER
 PLANNING DIVISION
 561-822-1449
 [email protected]


Account Summary | Usage Policy | Privacy Policy