Plan Review Details - Permit 17090752
Plan Review Stops For Permit 17090752
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2018-01-12 Cont ID  
Sent By shill Date 2018-01-12 Time 05:57 Rev Time 0.00
Received By shill Date 2018-01-12 Time 05:57 Sent To  
Notes
***NONE***

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2017-11-06 Cont ID  
Sent By shill Date 2017-11-06 Time 08:11 Rev Time 0.00
Received By shill Date 2017-11-06 Time 08:11 Sent To I
Notes
2017-11-06 08:12:56PRIOR TO ISSUANCE, ASSIGN CORRECT ADDRESS (NOT
 AVAILABLE AT THIS TIME FROM PAPA)
 74-43-44-03-28-000-0020
 LOT B, 245 EDMOR RD
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2018-01-23 Cont ID  
Sent By jgomez Date 2018-01-23 Time 12:23 Rev Time 0.00
Received By jgomez Date 2018-01-22 Time 16:02 Sent To  
Notes
2018-01-22 16:03:03BUILDING REVIEW APPROVED WITH PROVISO:
 1- ENERGY CALCULATIONS ARE TAKING THE CEILING FAN
 CREDIT. REVISE GREAT ROOM CEILING FAN SIZE TO COMPLY
 WITH SEC. R405.7.6 FBC-ENERGY CONSERVATION.
  
 2- SOIL TEST REPORT SUBMITTED NEEDS THE ENGINEER'S
 ORIGINAL SIGNATURE (NOT COPY). CHAPTER 471 F.S.
  
 3- PROVIDE PRODUCT APPROVAL FOR THE OVERHEAD GARAGE
 DOOR THAT MEETS THE DESIGN PRESSURES CALCULATED BY THE
 ARCHITECT ON SHEET A-301. (OK. SEE REVISION 18091139)
  
 4- DESIGNER OF RECORD TO APPROVE ABOVE PRODUCT
 APPROVAL. SEC. 107.3.4.1 CITY AMENDMENTS. NOTE: PLEASE
 PLACE THE REVIEW STAMP ON THE FRONT OF THE PRODUCT
 APPROVAL NOT ON THE BACK.
  
 5- PROVIDE SURVEY (2 COPIES) THAT MATCHES PROPOSED
 HOUSE IN LOT "B" AND THE ADDRESS 245 EDMOR RD.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2017-12-12 Cont ID  
Sent By jgomez Date 2017-12-12 Time 16:13 Rev Time 0.00
Received By jgomez Date 2017-12-11 Time 11:32 Sent To  
Notes
2017-12-11 11:45:22NEW SINGLE FAMILY RESIDENCE (R3) SECOND BUILDING REVIEW
 CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 1- IT LOOKS LIKE THE REVISED WINDOW FOR BEDROOM #2
 DOESN'T COMPLY WITH THE EGRESS REQUIREMENTS OF SEC.
 R310 FBC-RESIDENTIAL, 5TH EDITION (2014). ACCORDING TO
 THE PGT WINDOWS WEBSITE, THE SIZE OF WINDOWS SPECIFIED
 (SINGLE HUNG 36"X60") DOESN'T COMPLY WITH THE REQUIRED
 HEIGHT CLEAR OPENING AND TOTAL CLEAR OPENING FOR
 WINDOWS ON THE SECOND FLOOR. REVISE AS REQUIRED TO
 COMPLY OR PROVIDE MANUFACTURER'S CUT SHEETS SHOWING
 COMPLIANCE WITH ALL THE CLEAR OPENINGS. NOTE: KEEP IN
 MIND THAT EGRESS NEED TO BE ACCOMPLISHED BY THE NORMAL
 OPERATION OF THE WINDOW WITHOUT ANY ADDITIONAL STEP OR
 KNOWLEDGE TO OBTAIN THE REQUIRED OPENING.
  
 2- SHEET S-2: DESIGN PRESSURES SPECIFIED ON THE ROOF
 FRAMING NOTES FOR ROOF ZONES 2 AND 3 DON'T CORRESPOND
 TO EXPOSURE "D" BASED ON THE MEAN ROOF HEIGHT OF THIS
 TWO STORY BUILDING. REVISE AS REQUIRED. SEC. R301.1 AND
 TABLE R301.2(2) FBC-RESIDENTIAL.
  
 3- ENERGY CALCULATIONS SUBMITTED:
 A) FLOOR INFORMATION ON ITEM #8 IS MISSING THE
 INSULATION R-VALUE BETWEEN THE GARAGE AND THE A/C AREA
 ABOVE. REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC-ENERGY
 CONSERVATION.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED.
  
 B) PROVIDE COMPLETE INFORMATION ON TOP OF FORM,
 INCLUDING THE BUILDER'S NAME. SEC. R101.5.1.1.2
 FBC-ENERGY CONSERVATION.
 RESPONSE: REPEAT COMMENT.
  
 NOTE:
 LABEL FOR DOORS AND WINDOWS SHOWING THE U-FACTOR AND
 SHGC FACTOR SPECIFIED ON THE ENERGY CALCULATIONS WILL
 BE REQUIRED WHEN THE ENERGY CALCULATIONS DON'T USE THE
 DEFAULT FACTOR FOR GLAZING.
  
 4- NEW COMMENT: REVISED ENERGY CALCULATIONS ARE TAKING
 THE CEILING FAN CREDIT. PLANS NEED TO SPECIFY THE SIZE
 OF ALL CEILING FANS TO VERIFY COMPLIANCE WITH TABLE
 R405.7.6 FBC-ENERGY CONSERVATION.
  
 5- A) SOIL TEST REPORT SUBMITTED NEEDS THE ENGINEER'S
 ORIGINAL SEAL AND SIGNATURE AS REQUIRED BY CHAPTER 471
 FLORIDA STATUTE WHEN SUBMITTING DOCUMENTS FOR PUBLIC
 RECORDS.
 RESPONSE: REPEAT COMMENT. IT LOOKS LIKE THE ENGINEER'S
 SIGNATURE IS NOT ORIGINAL. IT LOOKS LIKE IS THE EXACT
 SAME COPY OF THE SIGNATURE ON ALL REPORTS SUBMITTED.
  
 B) SOIL TEST REPORT SUBMITTED IS MISSING A PLOT PLAN
 SHOWING THE LOCATION OF THE SOIL INVESTIGATION AS
 REQUIRED BY SEC. 1803.6 FBC-BUILDING, 5TH EDITION
 (2014).
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED. NOTE: THIS LOT
 WAS SUBDIVIDED ONTO 3 LOTS.
  
 6- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 A) CLEARLY SPECIFY WHERE ARE THE ETO DOORS DRAWING
 #ET0002 SUBMITTED GOING TO BE INSTALLED. PROVIDE THE
 FLORIDA PRODUCT APPROVAL COVER PAGE THAT CORRESPOND TO
 DRAWINGS SUBMITTED AS REQUESTED ON PREVIOUS CHECKLIST.
 IF THERE IS NOT FLORIDA PRODUCT APPROVAL DOOR
 MANUFACTURER MAY SUBMIT COMPLETE ORIGINAL ENGINEERING
 PACKAGE FOR BUILDING OFFICIAL REVIEW AND APPROVAL. MORE
 INFORMATION WILL BE PROVIDED IF DRAWINGS WILL BE
 SUBMITTED FOR BUILDING OFFICIAL APPROVAL. PLEASE ADVICE
 IF SUBMITTING DRAWINGS FOR BUILDING OFFICIAL REVIEW.
 MORE INFORMATION WILL BE PROVIDED REGARDING THE
 SUBMITTAL PACKAGE.
  
 B) BALCONIES WATERPROOFING UNDERLAYMENT. PROVIDE
 FLORIDA PRODUCT APPROVAL OR MIAMI DADE NOA FOR THE
 MASTERSEAL 550 WATERPROOFING SUBMITTED THIS TIME. NEED
 PRODUCT APPROVAL FOR CONCRETE DECK THAT IS DESIGNED TO
 RECEIVE FINISH FLOOR AS SPECIFIED BY THE ARCHITECT OF
 RECORD. CLEARLY MARK SPECIFIC ASSEMBLY TO BE INSTALLED
 AND PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS IF
 THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN PRESSURES
 FOR ALL DECK ZONES. IF THERE IS NOT PRODUCT APPROVAL,
 MANUFACTURER MAY SUBMIT COMPLETE ORIGINAL ENGINEERING
 PACKAGE FOR BUILDING OFFICIAL APPROVAL. NOTE: THERE ARE
 SEVERAL PRODUCTS THAT ALREADY HAVE A PRODUCT APPROVAL.
 FOR EXAMPLE LOOK AT SEALOFLEX PRODUCTS.
  
 C) ALUMINUM MULLIONS NOA 16-0218.03 SUBMITTED: CLEARLY
 IDENTIFY SIZE OF MULLIONS TO BE INSTALLED TO VERIFY
 COMPLIANCE WITH THE CALCULATED DESIGN PRESSURES.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED.
  
 D) OVERHEAD GARAGE DOOR. NEED PRODUCT APPROVAL FOR DOOR
 THAT MEETS THE DESIGN PRESSURES CALCULATED BY THE
 ARCHITECT ON SHEET A-301.
 RESPONSE: DESIGN PRESSURES OF NOA 15-0826.34 SUBMITTED
 ARE LOWER THAN THE CALCULATED DESIGN PRESSURES.
  
 E) BAHAMA SHUTTERS NOA 15-0316.11 SUBMITTED.
 RESPONSE: PROVIDE PROVIDE COMPLETE INSTALLATION
 SCHEDULE. SEE CITY SAMPLE.
  
 F) COLONIAL SHUTTERS AS SPECIFIED ON PLANS. AND,
 PROVIDE COMPLETE INSTALLATION SCHEDULE. SEE CITY
 SAMPLE.
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED.
  
 G) PRECAST LINTELS AS SPECIFIED ON PLANS.
 RESPONSE: REPEAT COMMENT.
  
 7- DESIGNER OF RECORD TO REVIEW AND APPROVE ALL PRODUCT
 APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY
 AMENDMENTS. NOTE: PLEASE PLACE THE REVIEW STAMP ON THE
 FRONT OF THE PRODUCT APPROVAL NOT ON THE BACK. THIS IS
 REQUIRED FOR PROPER RECORD RETENTION PURPOSES. WHEN THE
 STAMPS ARE PLACED ON THE BACK OF THE PRODUCT APPROVAL,
 THEY DON'T GET SCANNED. SEC. 107.2.1.4 CITY AMENDMENTS.
  
 8- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 THE COLONIAL SHUTTERS INSTALLATION SPECS SUBMITTED
 PRIOR TO SUBMITTAL TO THIS OFFICE. SEC. 107.3.4.2 CITY
 AMENDMENTS.
  
 9- THERE ARE TOO MANY PRODUCT APPROVALS SUBMITTED.
 CLEARLY MARK ON EACH PRODUCT APPROVAL LOCATION WHERE
 THE DOOR OR WINDOW IS GOING TO BE INSTALLED. REMOVE ALL
 PRODUCT APPROVALS THAT ARE NOT GOING TO BE USED TO
 AVOID CONFLICTS. SEC. 107.2.1 CITY AMENDMENTS.
  
 10- ONE SET OF PLANS SUBMITTED IS MISSING DRAWING M201
 AND S-4. PROVIDE 2 COMPLETE SETS. SEC. 107.1 CITY
 AMENDMENTS.
  
 11- SURVEY SUBMITTED: REVISE THE FLOOD INFORMATION. THE
 NEW FLOOD MAPS WENT INTO EFFECT ON OCTOBER 5TH 2017.
 PROVIDE ALL THE FLOOD INFORMATION BASED ON THE CURRENT
 FLOOD MAPS TO AVOID CONFLICTS. SEC. 107.2.1 CITY
 AMENDMENTS. (NOTE: SURVEY SPECIFIED IS INCORRECT ALSO.
 ACCORDING TO MAP DATED MARCH 1, 1979 THIS PROPERTY WAS
 LOCATED IN FLOOD ZONE "C" NOT "B").
  
  
 ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO HELP EXPEDITE THE REVIEW PROCESS.
 ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS
 FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-10-24 Cont ID  
Sent By jgomez Date 2017-10-23 Time 13:52 Rev Time 0.00
Received By jgomez Date 2017-10-23 Time 08:32 Sent To  
Notes
2017-10-23 12:33:06NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW
 COMMENTS.
 CODE: FBC 5TH EDITION (2014).
  
 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD) FOR IMPACT FEE ASSESSMENT.
 BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID
 RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF
 THE UNIFIED LAND DEVELOPMENT CODE.
  
 2- PLANS SUBMITTED HAVE A COPY OF THE SEAL AND
 SIGNATURE. ALL PLANS NEED TO HAVE THE ORIGINAL
 SIGNATURE OF THE ARCHITECT AS REQUIRED BY CHAPTER 481
 WHEN SUBMITTING DOCUMENTS FOR PUBLIC RECORDS.
  
 3- IT LOOKS LIKE THE CASEMENT WINDOWS SPECIFIED FOR THE
 GUEST BEDROOM AND BEDROOM #2 DON'T COMPLY WITH THE
 EGRESS REQUIREMENTS OF SEC. R310 FBC-RESIDENTIAL, 5TH
 EDITION (2014). ACCORDING TO THE PGT WINDOWS WEBSITE,
 THE SIZE OF WINDOWS SPECIFIED DON'T COMPLY WITH THE
 REQUIRED WIDTH CLEAR OPENING AND TOTAL CLEAR OPENING.
 REVISE AS REQUIRED TO COMPLY OR PROVIDE MANUFACTURER'S
 CUT SHEETS SHOWING COMPLIANCE WITH ALL THE CLEAR
 OPENINGS. NOTE: KEEP IN MIND THAT EGRESS NEED TO BE
 ACCOMPLISHED BY THE NORMAL OPERATION OF THE WINDOW
 WITHOUT ANY ADDITIONAL STEP OR KNOWLEDGE TO OBTAIN THE
 REQUIRED OPENING.
  
 4- SPECIFY SELF CLOSING DEVICE FOR THE GARAGE DOOR
 LEADING TO THE INTERIOR OF THE HOUSE AS REQUIRED BY
 SEC. R302.5.1 FBC-RESIDENTIAL.
  
 5- ENGINEERING CRITERIA ON THE NEW CONSTRUCTION NOTES
 ON SHEET A-301 SPECIFIES R2. THIS IS A SINGLE FAMILY
 RESIDENCE, THEREFORE THE CORRECT OCCUPANCY
 CLASSIFICATION IS R3. REVISE AS REQUIRED. SEC. 310.5
 FBC-BUILDING, 5TH EDITION (2014).
  
 6- SPECIFY CARBON MONOXIDE ALARMS ON THE SECOND FLOOR
 ON THE LOCATION REQUIRED BY SEC. R315.1
 FBC-RESIDENTIAL. NOTE: ELECTRICAL PLAN FOR THE FIRST
 FLOOR SHOWS SMOKE AND ALARMS AND CARBON MONOXIDE ALARMS
 COMBO, BUT SECOND FLOOR PLAN ONLY SHOWS SMOKE ALARMS.
  
 7- SIZE OF FOOTINGS SHOWN ON SHEET S-1 DON'T MATCH
 SIZES SHOWN ON THE WALL SECTIONS ON SHEET A-402. REVISE
 AS REQUIRED TO MATCH. SEC. 107.2.1 CITY AMENDMENTS.
  
 8- SPACING OF THE ANCHORS SHOWN ON THE LEDGER TABLE ON
 SHEET S-2 AND S-3 DOESN'T MATCH SPACING SHOWN ON THE
 TWO STORY WALL SECTION SHOWN ON SHEET A-402. REVISE AS
 REQUIRED TO MATCH. SEC. 107.2.1 CITY AMENDMENTS.
  
 9- SPECIFY ATTIC ACCESS LOCATION AND SIZE SHOWING
 COMPLIANCE WITH SEC. R807 FBC-RESIDENTIAL.
  
 10- BUILDING EXPOSURE SPECIFIED ON ROOF FRAMING NOTES
 ON SHEETS S-2 AND S-3 DOESN'T MATCH THE EXPOSURE
 SPECIFIED ON THE NEW CONSTRUCTION NOTES ON SHEET A-301.
 REVISE AS REQUIRED TO MATCH. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 11- CLARIFY WHY THE DESIGN PRESSURES SHOWN ON SHEETS
 S-2 AND S-3 ARE BASED ON 20 S.F TRIBUTARY AREA. PROVIDE
 THE DESIGN PRESSURES BASED ON THE ACTUAL EFFECTIVE AREA
 OR USE THE LOAD ASSOCIATED WITH THE LOWER EFFECTIVE
 AREA. SEE NOTE "B" OF TABLE R301.2(2) FC-RESIDENTIAL.
 NOTE: COORDINATE DESIGN PRESSURES WITH THOSE SHOWN ON
 SHEET A-301.
 CLARIFY WHY THE DESIGN PRESSURES FOR THE DOORS ARE
 HIGHER THAN THE DESIGN PRESSURES FOR THE WINDOWS.
 TYPICALLY, THE SMALLER THE OPENING THE HIGHER THE
 DESIGN PRESSURES.
  
 12- PROVIDE DETAILS AND SPECIFICATIONS FOR THE
 CONNECTION AT TOP AND BOTTOM OF STEEL COLUMN LOCATED BY
 THE GARAGE AREA AND GOING ALL THE WAY UP TO THE ROOF
 FRAMING. SEC. R301.1 FBC-RESIDENTIAL.
  
 13- SPECIFY DOUBLE LAYER OF WATER RESISTIVE BARRIER FOR
 WOOD FRAMED WALL WITH STUCCO AS REQUIRED BY SEC.
 R703.6.3 FBC-RESIDENTIAL.
  
 14- REVISE STUCCO THICKNESS SPECIFIED ON ALL WALL
 SECTIONS. NEED 7/8" MIN. THICKNESS NOT 5/8" AS REQUIRED
 BY TABLE R702.1(1) FBC-RESIDENTIAL.
  
 15- ENERGY CALCULATIONS SUBMITTED:
 A) AREAS SHOWN ON ITEM #8 DON'T MATCH ARCHITECTURAL
 PLANS SHEET A-101. REVISE AS REQUIRED. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014). NOTE: CHECK FIRST FLOOR AREA AND SECOND FLOOR
 AREA.
  
 B) FLOOR INFORMATION ON ITEM #8 IS MISSING THE
 INSULATION R-VALUE BETWEEN THE GARAGE AND THE A/C AREA
 ABOVE. REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC-ENERGY
 CONSERVATION.
  
 C) THE AREA SHOWN ON THE "SPACES" INFORMATION ON PAGE 2
 OF 5 DOESN'T MATCH PLANS. COORDINATE WITH ITEM #15(A)
 ABOVE. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 D) ROOF MATERIAL SHOWN ON PAGE 2 OF 5 DOESN'T MATCH
 PLANS. REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC-ENERGY
 CONSERVATION.
  
 E) THE VENT RATIO SHOWN ON PAGE 2 OF 5 IS 1/300.
 ARCHITECTURAL PLANS DON'T SPECIFY THIS VENT RATIO.
 PERSON PREPARING THE ENERGY CALCULATIONS TO PROVIDE
 COMPLETE DETAILS AND SPECIFICATIONS SHOWING COMPLIANCE
 WITH THE 1/300 RATIO AS REQUIRED BY THE EXCEPTION OF
 SEC. R806.2 FBC-RESIDENTIAL. OR, SPECIFY THE TYPICAL
 1/150 VENT RATIO.
  
 F) CEILING AREAS SHOWN ON PAGE 3 OF 5 DON'T MATCH
 PLANS. REVISE AS REQUIRED. WHERE ARE THESE AREAS TAKEN
 FROM?. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 G) DOORS INFORMATION SHOWN ON PAGE 3 OF 5 DOESN'T MATCH
 PLANS AND PRODUCT APPROVALS SUBMITTED. REVISE AS
 REQUIRED. THE SIZE DOESN'T MATCH PLANS AND THIS IS A
 DOOR WITH GLASS. DOORS WITH GLASS NEED TO BE CONSIDERED
 IN THE GLAZING (WINDOWS) AREA AS REQUIRED BY SEC.
 R405.5.3.3 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 H) WINDOWS INFORMATION SHOWN ON PAGE 3 OF 5 DOESN'T
 MATCH PLANS. REVISE AS REQUIRED. NOTE: REVISE THE
 ORIENTATION, AREA AND OVERHANG DEPTH AND SEPARATION TO
 MATCH PLANS. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 I) GARAGE FLOOR AREA SHOWN ON PAGE 4 OF 5 DOESN'T MATCH
 AREA SHOWN ON PLANS. REVISE AS REQUIRED. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 J) PROVIDE COMPLETE INFORMATION ON TOP OF FORM,
 INCLUDING THE BUILDER'S NAME. SEC. R101.5.1.1.2
 FBC-ENERGY CONSERVATION.
  
 NOTE:
 LABEL FOR DOORS AND WINDOWS SHOWING THE U-FACTOR AND
 SHGC FACTOR SPECIFIED ON THE ENERGY CALCULATIONS WILL
 BE REQUIRED WHEN THE ENERGY CALCULATIONS DON'T USE THE
 DEFAULT FACTOR FOR GLAZING.
  
 16- A) SOIL TEST REPORT SUBMITTED NEEDS THE ENGINEER'S
 ORIGINAL SEAL AND SIGNATURE AS REQUIRED BY CHAPTER 471
 FLORIDA STATUTE WHEN SUBMITTING DOCUMENTS FOR PUBLIC
 RECORDS.
  
 B) SOIL TEST REPORT SUBMITTED IS MISSING A PLOT PLAN
 SHOWING THE LOCATION OF THE SOIL INVESTIGATION AS
 REQUIRED BY SEC. 1803.6 FBC-BUILDING, 5TH EDITION
 (2014).
  
 17- PROVIDE COMPLETE WALL SECTIONS AND SPECIFICATIONS
 FOR THE CONSTRUCTION OF THE CONCRETE BALCONIES AS SHOWN
 ON PLANS. SEC. R301.1 FBC-RESIDENTIAL. NOTE: ALSO
 SPECIFY FLOOR FINISH. THIS IS REQUIRED TO VERIFY
 COMPLIANCE OF THE UNDERLAYMENT PRODUCT APPROVAL.
  
 18- PROVIDE COMPLETE SECTION/DETAIL AND SPECIFICATIONS
 FOR THE INSTALLATION OF THE DECORATIVE SHUTTERS SHOWN
 ON THE FRONT ELEVATION ON THE SECOND FLOOR COVERED
 BALCONY. SEC. R301.1 FBC-RESIDENTIAL.
  
 19- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 A) ENTRY DOOR WITH SIDELITE AS SHOWN ON PLANS. NOTE:
 NEED PRODUCT APPROVAL FOR DOOR THAT MEETS OR EXCEEDS
 THE DESIGN PRESSURES CALCULATED BY THE ARCHITECT ON
 SHEET A-301. AND NEED TO PROVIDE FLORIDA PRODUCT
 APPROVAL COVER PAGE THAT CORRESPONDS TO DRAWING #:
 ET0002 SUBMITTED. SUBMIT TWO COPIES. ONLY ONE WAS
 SUBMITTED.
  
 B) MODIFIED BITUMEN FOR BALCONIES UNDERLAYMENT. NOA
 12-0703.06 SUBMITTED IS FOR WOOD DECKS. NEED PRODUCT
 APPROVAL FOR CONCRETE DECK THAT IS DESIGNED TO RECEIVE
 FINISH FLOOR AS SPECIFIED BY THE ARCHITECT OF RECORD.
 NOTE: CLEARLY MARK SPECIFIC ASSEMBLY TO BE INSTALLED
 AND PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS IF
 THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN PRESSURES
 FOR ALL DECK ZONES.
  
 C) PEEL AND STICK UNDERLAYMENT AS SPECIFIED ON
 PLANS/DETAILS. ROOFING UNDERLAYMENT NOA 16-1116.09
 SUBMITTED: CLEARLY MARK WHICH APPROVED UNDERLAYMENT
 ASSEMBLY IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE
 WITH THE PROPOSED INSTALLATION.
  
 D) METAL ROOF AS SPECIFIED ON PLANS.
  
 E) ALUMINUM MULLIONS NOA 16-0218.03 SUBMITTED: CLEARLY
 IDENTIFY SIZE OF MULLIONS AND WHERE IS GOING TO BE
 INSTALLED.
  
 F) THERE ARE DIFFERENT NOA'S SUBMITTED FOR THE FRENCH
 DOORS. NOA 16-0629.16 AND NOA 16-0629.17. CLEARLY MARK
 WHERE EACH DOOR IS GOING TO BE INSTALLED TO VERIFY
 COMPLIANCE WITH THE DESIGN PRESSURES.
  
 G) OVERHEAD GARAGE DOOR. NEED PRODUCT APPROVAL FOR DOOR
 THAT MEETS THE DESIGN PRESSURES CALCULATED BY THE
 ARCHITECT ON SHEET A-301. AND, PROVIDE COPY OF FLORIDA
 PRODUCT APPROVAL COVER PAGE THAT CORRESPONDS TO
 DRAWINGS SUBMITTED.
  
 H) GARAGE SIDE DOOR. NEED PRODUCT APPROVAL FOR DOOR
 THAT MEETS THE DESIGN PRESSURES CALCULATED BY THE
 ARCHITECT ON SHEET A-301. AND, PROVIDE COPY OF FLORIDA
 PRODUCT APPROVAL COVER PAGE THAT CORRESPONDS TO
 DRAWINGS SUBMITTED.
  
 I) BAHAMA SHUTTERS AS SPECIFIED ON PLANS. AND, PROVIDE
 COMPLETE INSTALLATION SCHEDULE. SEE CITY SAMPLE.
  
 J) COLONIAL SHUTTERS AS SPECIFIED ON PLANS. AND,
 PROVIDE COMPLETE INSTALLATION SCHEDULE. SEE CITY
 SAMPLE.
  
 K) PRECAST LINTELS AS SPECIFIED ON PLANS.
  
 L) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON PLANS
 AND DETAILS. NOTE: PROVIDE ONLY THE FLORIDA PRODUCT
 APPROVAL COVER PAGE AND PAGE SHOWING THE SPECIFIED
 CONNECTOR.
  
 20- ARCHITECT OF RECORD TO REVIEW AND APPROVE ALL
 PRODUCT APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY
 AMENDMENTS. NOTE: PLEASE PLACE THE REVIEW STAMP ON THE
 FRONT OF THE PRODUCT APPROVAL NOT ON THE BACK. THIS IS
 REQUIRED FOR PROPER RECORD RETENTION PURPOSES. WHEN THE
 STAMPS ARE PLACED ON THE BACK OF THE PRODUCT APPROVAL,
 THEY DON'T GET SCANNED. SEC. 107.2.1.4 CITY AMENDMENTS.
  
 ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO HELP EXPEDITE THE REVIEW PROCESS.
 ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS
 FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2018-01-24 Cont ID  
Sent By jpearson Date 2018-01-24 Time 14:09 Rev Time 0.00
Received By jpearson Date 2018-01-24 Time 14:09 Sent To I
Notes
2018-01-22 16:04:25NEW REVISED PLANS SUBMITTED. JG.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-12-13 Cont ID  
Sent By jpearson Date 2017-12-13 Time 14:39 Rev Time 0.00
Received By jpearson Date 2017-12-13 Time 14:39 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-10-20 Cont ID  
Sent By jleahy Date 2017-10-20 Time 09:15 Rev Time 0.00
Received By jleahy Date 2017-10-20 Time 09:15 Sent To  
Notes
2017-10-20 10:53:16 
 FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED
 NFPA 70 2011 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
  
 A GFCI PROTECTED OUTLET ON A 20 AMP CIRCUIT IS REQUIRED
 WITHIN 3 FEET OF EACH BASIN. PROVIDE CORRECTION.
 NEC 210.11(C)(3), 210.52(D); FBC RE 3703.4, 3901.6
 PAGE E-101 GUEST STUDY BATHROOM, PAGE E-102 BEDROOM #2
 BATHROOM
  
 PROVIDE GFCI PROTECTION FOR ALL OUTLETS IN GARAGE. NEC
 210.8; FBC RE3902.2
 INCLUDES GARAGE DOOR OPENER.
  
 SEVERAL AREAS DO NOT COMPLY WITH THE WALL SPACING
 REQUIREMENTS FOR OUTLETS. RECEPTACLES SHALL BE
 INSTALLED SO THAT NO POINT MEASURED HORIZONTALLY ALONG
 THE FLOOR LINE OF ANY WALL SPACE IS MORE THAN
 6 FEET FROM A RECEPTACLE OUTLET. PROVIDE CORRECTION.
 NEC 210.52; FBC RE3901.2.1
 PAGE E-101 GREAT ROOM, PAGE E-102 MASTER SUTIE, BEDROOM
 #2
  
 PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED PER
 CODE. SHOW ON PLAN ALL EXISTING ALARMS.
 IF NONE ARE EXISTING OR NOT TO CODE, SHOW AS NEW
 INSTALLATIONS. FBC R314.3, FBC 107.2
 PAGE E-102 TOP OF STAIRS AND MEDIA LOFT WHICH IS WITHIN
 10' OF SLEEPING AREAS.
  
 SHOW LOCATION OF SERVICE AND PANELS, NO LOCATION SHOWN.
 FBC RE3601.6.2 SERVICE DISCONNECT LOCATION.
 PAGE E-101
  
 CORD-CONNECTED LUMINAIRES, CHAIN-, CABLE-, OR
 CORD-SUSPENDED-LUMINAIRES, LIGHTING TRACK, PENDANTS,
 AND CEILING-SUSPENDED (PADDLE) FANS SHALL NOT HAVE ANY
 PARTS LOCATED WITHIN A ZONE MEASURED 3 FEET
 (914 MM) HORIZONTALLY AND 8 FEET (2438 MM) VERTICALLY
 FROM THE TOP OF A BATHTUB RIM FBC RE4003.11
 LIGHT OVER TUB ON PAGE E-102
  
 ALL CIRCUITS AND CIRCUIT MODIFICATIONS SHALL BE LEGIBLY
 IDENTIFIED AS TO THEIR CLEAR, EVIDENT, AND SPECIFIC
 PURPOSE OR USE. THE IDENTIFICATION SHALL INCLUDE
 SUFFICIENT DETAIL TO ALLOW EACH CIRCUIT TO BE
 DISTINGUISHED
 FROM ALL OTHERS. SPARE POSITIONS THAT CONTAIN UNUSED
 OVERCURRENT DEVICES OR SWITCHES SHALL BE DESCRIBED
 ACCORDINGLY. THE IDENTIFICATION SHALL BE INCLUDED IN A
 CIRCUIT DIRECTORY LOCATED ON THE FACE OF THE
 PANELBOARD ENCLOSURE OR INSIDE THE PANEL DOOR. CIRCUITS
 SHALL NOT BE DESCRIBED IN A MANNER THAT DEPENDS
 ON TRANSIENT CONDITIONS OF OCCUPANCY. FBC RE3706.2
 PANEL SCHEDULES NOT DESCRIPTIVE ENOUGH FOR CIRCUITS.

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2017-12-22 Cont ID  
Sent By tklarge Date 2017-12-22 Time 09:53 Rev Time 0.00
Received By tklarge Date 2017-12-22 Time 09:53 Sent To  
Notes
2017-12-22 09:54:33A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL
 PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT
 THIS TIME. A GAS PERMIT IS REQUIRED FOR A CONTRACTOR TO
 PERFORM THE RELATED WORK. PROVIDE COMPLETE PLANS THAT
 REFLECT THE ENTIRE SCOPE OF GAS WORK TO BE DONE. WPB
 AMEND. TO FBC SEC.107.2.1.
  
 GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE
 FBC-R, SEC. G2404.3.
 GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL
 GAS SEC. 301.3.
  
 A SEPARATE PERMIT IS REQUIRED FOR THE GAS INSTALLATION.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2018-02-07 Cont ID  
Sent By cthroop Date 2018-02-07 Time 13:52 Rev Time 0.00
Received By cthroop Date 2018-01-31 Time 10:47 Sent To I
Notes
2018-02-01 10:48:00IMPACT FEES ROUTED TO JGOMEZ

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2018-01-24 Time   Rev Time 0.00
Received By lmarchan Date 2018-01-08 Time 09:42 Sent To  
Notes
2018-01-10 09:42:13R33

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-01-02 Cont ID  
Sent By cpuell Date 2018-01-02 Time 16:28 Rev Time 0.00
Received By cpuell Date 2017-11-28 Time 15:25 Sent To  
Notes
2017-11-29 15:25:19R33

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-11-06 Cont ID  
Sent By shill Date 2017-11-06 Time 08:13 Rev Time 0.00
Received By shill Date 2017-09-28 Time 10:25 Sent To  
Notes
2017-09-29 10:26:04R09

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 4 Status P Date 2018-02-07 Cont ID  
Sent By cthroop Date 2018-02-07 Time 13:52 Rev Time 0.00
Received By cthroop Date 2018-02-07 Time 13:51 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status F Date 2018-01-23 Cont ID  
Sent By jgomez Date 2018-01-23 Time 12:38 Rev Time 0.00
Received By jgomez Date 2018-01-23 Time 12:38 Sent To  
Notes
2018-01-23 12:38:161- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD)
 FOR IMPACT FEE ASSESSMENT. BRING BACK COUNTY STAMPED
 PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE.
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2017-12-11 Cont ID  
Sent By jgomez Date 2017-12-11 Time 11:45 Rev Time 0.00
Received By jgomez Date 2017-12-11 Time 11:45 Sent To  
Notes
2017-12-11 11:46:241- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD)
 FOR IMPACT FEE ASSESSMENT. BRING BACK COUNTY STAMPED
 PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE.
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2017-10-23 Cont ID  
Sent By jgomez Date 2017-10-23 Time 13:50 Rev Time 0.00
Received By jgomez Date 2017-10-23 Time 13:50 Sent To  
Notes
2017-10-23 13:52:411- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD) FOR IMPACT FEE ASSESSMENT.
 BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID
 RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF
 THE UNIFIED LAND DEVELOPMENT CODE.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2018-01-23 Cont ID  
Sent By jgomez Date 2018-01-23 Time 16:02 Rev Time 0.00
Received By jgomez Date 2018-01-23 Time 16:02 Sent To  
Notes
2018-01-23 16:04:34MECHANICAL REVIEW APPROVED WITH PROVISO:
  
 1- PROVIDE COMPLETE EQUIPMENT SIZING CALCULATIONS
 SHOWING COMPLIANCE WITH ALL THE REQUIREMENTS OF SEC.
 R403.6.1 FBC-ENERGY CONSERVATION, 5TH EDITION (2014).
  
 2- REVISE MASTER BEDROOM TRANSFER DUCT SIZE TO COMPLY
 WITH SEC. M1602.4 FBC-RESIDENTIAL, 5TH EDITION (2014).
 NOTE: WHEN SIZING THE DUCT KEEP IN MIND THAT NEED TO
 TAKE INTO CONSIDERATION ALL THE SUPPLY AIR THAT IS
 GOING INTO THE MASTER BEDROOM. SEE EXCEPTION #3 OF SEC.
 M1602.4.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2017-12-13 Cont ID  
Sent By jgomez Date 2017-12-12 Time 16:53 Rev Time 0.00
Received By jgomez Date 2017-12-12 Time 07:52 Sent To  
Notes
2017-12-12 16:53:01NEW SINGLE FAMILY RESIDENCE (R3) SECOND MECHANICAL
 REVIEW CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 ORIGINAL COMMENT:
 1- PROVIDE COMPLETE EQUIPMENT SIZING CALCULATIONS
 SHOWING COMPLIANCE WITH ALL THE REQUIREMENTS OF SEC.
 R403.6.1 FBC-ENERGY CONSERVATION, 5TH EDITION (2014).
 RESPONSE: REPEAT COMMENT. NOT ADDRESSED.
  
 ORIGINAL COMMENT:
 2- SPECIFY THE SIZE OF THE TRANSFER DUCT FOR THE
 BALANCED RETURN AIR FOR ALL THE ROOMS ON THE FIRST
 FLOOR AND ALL THE ROOMS ON THE SECOND FLOOR SHOWING
 COMPLIANCE WITH SEC. M1602.4 FBC-RESIDENTIAL, 5TH
 EDITION (2014).
 NOTE: WHEN SIZING THE DUCT KEEP IN MIND THAT NEED TO
 TAKE INTO CONSIDERATION ALL THE SUPPLY AIR THAT IS
 GOING INTO THE MASTER BEDROOM. SEE EXCEPTION #3 OF SEC.
 M1602.4.
  
 RESPONSE: SIZE OF TRANSFER DUCT SPECIFIED FOR THE
 MASTER BEDROOM DOESN'T COMPLY. REVISE AS REQUIRED.
 NOTE: KEEP IN MIND THAT NEED TO CONSIDER ALL THE SUPPLY
 TO THE MASTER BEDROOM, INCLUDING CLOSETS, BATHROOMS,
 ETC.
  
 ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO HELP EXPEDITE THE REVIEW PROCESS.
 ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS
 FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-10-24 Cont ID  
Sent By jgomez Date 2017-10-24 Time 16:35 Rev Time 0.00
Received By jgomez Date 2017-10-24 Time 12:09 Sent To  
Notes
2017-10-24 16:38:25NEW SINGLE FAMILY RESIDENCE (R3) MECHANICAL REVIEW
 COMMENTS.
 CODE: FBC 5TH EDITION (2014).
  
 1- PLANS SUBMITTED HAVE A COPY OF THE SEAL AND
 SIGNATURE. ALL PLANS NEED TO HAVE THE ORIGINAL
 SIGNATURE OF THE ARCHITECT AS REQUIRED BY CHAPTER 481
 WHEN SUBMITTING DOCUMENTS FOR PUBLIC RECORDS.
  
 2- PROVIDE COMPLETE EQUIPMENT SIZING CALCULATIONS
 SHOWING COMPLIANCE WITH ALL THE REQUIREMENTS OF SEC.
 R403.6.1 FBC-ENERGY CONSERVATION, 5TH EDITION (2014).
  
 3- SPECIFY THE SIZE OF THE TRANSFER DUCT FOR THE
 BALANCED RETURN AIR FOR ALL THE ROOMS ON THE FIRST
 FLOOR AND ALL THE ROOMS ON THE SECOND FLOOR SHOWING
 COMPLIANCE WITH SEC. M1602.4 FBC-RESIDENTIAL, 5TH
 EDITION (2014).
 NOTE: WHEN SIZING THE DUCT KEEP IN MIND THAT NEED TO
 TAKE INTO CONSIDERATION ALL THE SUPPLY AIR THAT IS
 GOING INTO THE MASTER BEDROOM. SEE EXCEPTION #3 OF SEC.
 M1602.4.
  
 ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO HELP EXPEDITE THE REVIEW PROCESS.
 ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS
 FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-12-22 Cont ID  
Sent By tklarge Date 2017-12-22 Time 09:53 Rev Time 0.00
Received By tklarge Date 2017-12-22 Time 05:54 Sent To  
Notes
2017-12-13 11:35:09NEW DRAWINGS SUBMITTED. JG.

Review Stop P PLUMBING
Rev No 1 Status P Date 2017-10-12 Cont ID  
Sent By thunt Date 2017-10-12 Time 07:08 Rev Time 0.00
Received By thunt Date 2017-10-12 Time 07:07 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2018-01-23 Cont ID  
Sent By jgomez Date 2018-01-23 Time 15:58 Rev Time 0.00
Received By jgomez Date 2018-01-23 Time 15:58 Sent To  
Notes
2018-01-23 16:01:33APPROVED:
 1- METAL ROOF UNDERLAYMENT NOA16-1116.09.
 2- METAL ROOF SYSTEM NOA 14-0107.04
 3- BALCONY WATERPROOFING: SEALOFLEX WATERPROOFING
 SYSTEM OVER CONCRETE DECK NOA 16-0801.04.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2017-12-12 Cont ID  
Sent By jgomez Date 2017-12-12 Time 16:56 Rev Time 0.00
Received By jgomez Date 2017-12-12 Time 13:19 Sent To  
Notes
2017-12-12 17:00:221- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 A) BALCONIES WATERPROOFING UNDERLAYMENT. PROVIDE
 FLORIDA PRODUCT APPROVAL OR MIAMI DADE NOA FOR THE
 MASTERSEAL 550 WATERPROOFING SUBMITTED THIS TIME. NEED
 PRODUCT APPROVAL FOR CONCRETE DECK THAT IS DESIGNED TO
 RECEIVE FINISH FLOOR AS SPECIFIED BY THE ARCHITECT OF
 RECORD. CLEARLY MARK SPECIFIC ASSEMBLY TO BE INSTALLED
 AND PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS IF
 THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN PRESSURES
 FOR ALL DECK ZONES. IF THERE IS NOT PRODUCT APPROVAL,
 MANUFACTURER MAY SUBMIT COMPLETE ORIGINAL ENGINEERING
 PACKAGE FOR BUILDING OFFICIAL APPROVAL. NOTE: THERE ARE
 SEVERAL PRODUCTS THAT ALREADY HAVE A PRODUCT APPROVAL.
 FOR EXAMPLE LOOK AT SEALOFLEX PRODUCTS.
  
 2- DESIGNER OF RECORD TO REVIEW AND APPROVE ALL PRODUCT
 APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY
 AMENDMENTS. NOTE: PLEASE PLACE THE REVIEW STAMP ON THE
 FRONT OF THE PRODUCT APPROVAL NOT ON THE BACK. THIS IS
 REQUIRED FOR PROPER RECORD RETENTION PURPOSES. WHEN THE
 STAMPS ARE PLACED ON THE BACK OF THE PRODUCT APPROVAL,
 THEY DON'T GET SCANNED. SEC. 107.2.1.4 CITY AMENDMENTS.
  
  
 APPROVED:
 1- METAL ROOF UNDERLAYMENT NOA16-1116.09.
 2- METAL ROOF SYSTEM NOA 14-0107.04

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2017-10-24 Cont ID  
Sent By jgomez Date 2017-10-24 Time 16:33 Rev Time 0.00
Received By jgomez Date 2017-10-24 Time 16:33 Sent To  
Notes
2017-10-24 16:34:511- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 A) MODIFIED BITUMEN FOR BALCONIES UNDERLAYMENT. NOA
 12-0703.06 SUBMITTED IS FOR WOOD DECKS. NEED PRODUCT
 APPROVAL FOR CONCRETE DECK THAT IS DESIGNED TO RECEIVE
 FINISH FLOOR AS SPECIFIED BY THE ARCHITECT OF RECORD.
 NOTE: CLEARLY MARK SPECIFIC ASSEMBLY TO BE INSTALLED
 AND PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS IF
 THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN PRESSURES
 FOR ALL DECK ZONES.
  
 B) PEEL AND STICK UNDERLAYMENT AS SPECIFIED ON
 PLANS/DETAILS. ROOFING UNDERLAYMENT NOA 16-1116.09
 SUBMITTED: CLEARLY MARK WHICH APPROVED UNDERLAYMENT
 ASSEMBLY IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE
 WITH THE PROPOSED INSTALLATION.
  
 C) METAL ROOF AS SPECIFIED ON PLANS.

Review Stop Z ZONING
Rev No 3 Status P Date 2018-01-19 Cont ID  
Sent By awooten Date 2018-01-19 Time   Rev Time 0.00
Received By awooten Date 2018-01-19 Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date   Cont ID  
Sent By AW Date   Time   Rev Time 0.00
Received By   Date 2017-12-29 Time   Sent To  
Notes
2018-01-02 16:02:48*********************ZONING REVIEW
 FAILED******************************
  
 LANDSCAPING:
 GENERAL LANDSCAPING STANDARDS FOR SINGLE-FAMILY
 DWELLING UNITS SHALL BE AS FOLLOWS:
 A. SINGLE-FAMILY DWELLING UNITS. FOR SINGLE-FAMILY
 DWELLING UNITS, AT LEAST ONE SHADE, FLOWERING OR FRUIT
 TREE SHALL BE PLANTED FOR EACH 1,200 SQUARE FEET OF
 OPEN SPACE OR PORTION THEREOF. FOR SINGLE-FAMILY
 DWELLING UNITS, AT LEAST ONE SHRUB SHALL BE PLANTED FOR
 EACH 500 SQUARE FEET OF OPEN SPACE OR PORTION THEREOF.
 B. PLEASE SUBMIT A SEPARATE LANDSCAPE PERMIT AND
 IRRIGATION PLAN WITH TWO (2) COPIES OF A LANDSCAPE PLAN
 SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF
 THE ZLDR.
  
 ALANA WOOTEN
 ASSOCIATE PLANNER
 PLANNING DIVISION
 561-822-1449
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date   Cont ID  
Sent By   Date 2017-10-25 Time   Rev Time  
Received By   Date 2017-10-25 Time   Sent To  
Notes
2017-10-25 15:45:38*****ZONING REVIEW FAILED********
  
 SETBACK ENCROACHMENTS:
 STRUCTURAL INTRUSIONS. STRUCTURAL OVERHANGS, INCLUDING
 BUT NOT LIMITED TO BALCONIES, CORNICES, GUTTERS, EAVES,
 AND ROOF OVERHANG PROJECTIONS SHALL NOT EXTEND FARTHER
 THAN THREE FEET INTO ANY SETBACK.
  
 LANDSCAPING:
 GENERAL LANDSCAPING STANDARDS FOR SINGLE-FAMILY
 DWELLING UNITS SHALL BE AS FOLLOWS:
 A. SINGLE-FAMILY DWELLING UNITS. FOR SINGLE-FAMILY
 DWELLING UNITS, AT LEAST ONE SHADE, FLOWERING OR FRUIT
 TREE SHALL BE PLANTED FOR EACH 1,200 SQUARE FEET OF
 OPEN SPACE OR PORTION THEREOF. FOR SINGLE-FAMILY
 DWELLING UNITS, AT LEAST ONE SHRUB SHALL BE PLANTED FOR
 EACH 500 SQUARE FEET OF OPEN SPACE OR PORTION THEREOF.
 B. PLEASE SUBMIT A SEPARATE LANDSCAPE PERMIT AND
 IRRIGATION PLAN WITH TWO (2) COPIES OF A LANDSCAPE PLAN
 SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF
 THE ZLDR.
  
 MECHANICAL EQUIPMENT:
 MECHANICAL EQUIPMENT MAY NOT PROJECT MORE THAN FOUR
 FEET INTO A SETBACK. WINDOW AIR-CONDITIONING UNITS MAY
 NOT PROJECT MORE THAN 18 INCHES INTO A REQUIRED SIDE
 SETBACK.
  
 DRIVEWAY REQUIRES A SEPARATE PERMIT.
  
 PLEASE LET ME KNOW IF YOU HAVE ANY QUESTIONS.
  
 ALANA WOOTEN
 ASSOCIATE PLANNER
 PLANNING DIVISION
 561-822-1449
 [email protected]