Plan Review Details - Permit 17090674
| Plan Review Stops For Permit 17090674 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-11-09 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-11-09 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-11-09 |
Time |
11:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-10-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-10-06 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-10-06 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2017-10-06 14:38:00 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | DUE TO THE DEFICIENCIES OF THIS PLAN, A COMPLETE AND | | | THOROUGH REVIEW CANNOT BE PERFORMED AT THIS TIME. UPON | | | RE-SUBMITTAL, ADDITIONAL COMMENTS MAY BE MADE. | | | | | | IS SHED A PRE-ENGINEERED SHED OR A SITE BUILT SHED? | | | | | | 1. PRE-ENGINEERED SHED - PROVIDE MANUFACURERS | | | INSTALLATION INSTRUCTIONS. | | | A. PROVIDE FOUNDATION PLAN. | | | B. PROVIDE PRE-ENGINEERED DESIGN. | | | C. IDENTIFY TYPE OF TIE-DOWN TO FOUNDATION. | | | | | | 2. SITE BUILT SHED | | | A. PROVIDE FOUNDATION PLAN ? FOOTINGS/SLAB ON | | | GRADE/RE-INFORCING | | | B. PROVIDE BUILDING PLANS ? | | | 1. FLOOR | | | 2. WALLS | | | 3. ROOF FRAMING | | | C. WINDOW AND/OR DOOR SCHEDULE WITH ROUGH OPENINGS AND | | | DESIGN WIND LOADS. | | | D. PRODUCT APPROVALS FOR ALL ROOFING, WINDOWS AND/OR | | | DOORS. | | | E. SITE PLAN WITH SETBACKS FROM PROPERTY LINES. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-11-09 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-11-09 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-11-01 |
Time |
14:15 |
Sent To |
I |
|
| Notes |
| 2017-11-02 14:16:00 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-10-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-10-06 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-09-27 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2017-09-28 10:00:13 | ROUTED TO ZONING |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2017-11-07 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2017-11-07 |
Time |
17:12 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2017-11-07 |
Time |
10:07 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2017-10-02 |
|
|
Cont ID |
|
| Sent By |
njwira |
Date |
2017-10-02 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2017-09-28 |
Time |
15:54 |
Sent To |
B |
|
| Notes |
| 2017-10-02 11:21:05 | 10/2/17- FAILED | | | | | | 94-304(B)2- MUST INDICATE ON THE PLANS THE 5FT. SIDE | | | AND REAR SETBACK. | | | 94-304(B)4- WHAT IS THE HEIGHT OF THE SHED | | | 94-304(B)3- MUST INDICATE 6FT. BUILDING SEPORATION | | | | | | | | | PLEASE CONTACT | | | NATHAN WIRA- ZONING TECHNICIAN | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING AND ZONING | | | DIVISION | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS ST. | | | WEST PALM BEACH, FL 33402 | | | OFFICE HOURS: M-F 8AM - 5PM | | | (561)822-1442 | | | [email protected] | | | |
|
|
|