Plan Review Details - Permit 17090634
Plan Review Stops For Permit 17090634
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2018-02-27 Cont ID  
Sent By rmcdouga Date 2018-02-27 Time 11:21 Rev Time 0.00
Received By rmcdouga Date 2018-02-27 Time 11:21 Sent To  
Notes
***NONE***

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2017-10-19 Cont ID  
Sent By rmcdouga Date 2017-10-19 Time 17:12 Rev Time 0.00
Received By rmcdouga Date 2017-10-19 Time 17:12 Sent To  
Notes
2017-10-19 17:23:23THE PERMIT CAN NOT BE ISSUED UNTIL AN ADDRESS HAS BEEN
 ASSIGNED TO THE PROPERTY. IN ORDER TO OBTAIN AN
 ADDRESS, PLEASE CONTACT MICHEAL ORIO BY PHONE AT
 561-494-1080 OR BY EMAIL AT [email protected].

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-12-21 Cont ID  
Sent By rmcdouga Date 2017-12-21 Time 18:16 Rev Time 0.00
Received By rmcdouga Date 2017-12-21 Time 16:50 Sent To I
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-10-19 Cont ID  
Sent By rmcdouga Date 2017-10-19 Time 16:24 Rev Time 0.00
Received By rmcdouga Date 2017-10-18 Time 16:16 Sent To  
Notes
2017-10-19 15:27:55PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) SUBMIT TWO COPIES OF A SURVEY OF THE PROPERTY. FBC
 107.2.1
  
 2) PROVIDE A DRAINAGE PLAN THAT SHOWS COMPLIANCE WITH
 FBC - R401.3 DRAINAGE. SURFACE DRAINAGE SHALL BE
 DIVERTED TO A STORM SEWER CONVEYANCE OR OTHER APPROVED
 POINT OF COLLECTION THAT DOES NOT CREATE A HAZARD. LOTS
 SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM
 FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6
 INCHES (152 MM) WITHIN THE FIRST 10 FEET (3048 MM).
 EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER
 PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL
 WITHIN 10 FEET (3048 MM), DRAINS OR SWALES SHALL BE
 CONSTRUCTED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE.
 IMPERVIOUS SURFACES WITHIN 10 FEET (3048 MM) OF THE
 BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF 2
 PERCENT AWAY FROM THE BUILDING.
  
 3) ON SHEET S.1, UNDER DESIGN CRITERIA LETTER (D) THE
 LAST ZONE SHOULD BE NUMBER 5, NOT 3. FBC-R FIGURE
 301.2(7)
  
 4) THE DOOR BETWEEN THE GARAGE AND THE RESIDENCE SHALL
 COMPLY WITH FBC-R 302.5.1 AND BE EQUIPPED WITH A
 SELF-CLOSING DEVICE.
  
 5) THE DESIGN PARAMETERS ON SHEET S.3 SPECIFY EXPOSURE
 CATEGORY "D". ON SHEET S.3, EXPOSURE "C" IS SPECIFIED
 AND THE DESIGN PRESSURES THAT ARE PROVIDED ARE FOR
 EXPOSURE "C". THE STRUCTURE IS LOCATED IN EXPOSURE "C".
 PLEASE CORRECT THE EXPOSURE ON SHEET S.3.
 FBC-R301.2.1.4
  
 6) SUBMIT TWO SETS OF PRODUCT APPROVALS FOR THE DRY
 STACK STONE CLADDING. FBC 107.3.4 - PROVIDE TWO SETS OF
 PRODUCT APPROVALS FOR THOSE PRODUCTS WHICH ARE
 REGULATED BY FAC 61G20-3.001 PER FLORIDA STATUTE
 553.842 (5) THAT HAVE BEEN REVIEWED AND APPROVED IN
 WRITING BY THE DESIGNER OF RECORD.
  
 7) SUBMIT TWO SETS OF PRODUCT APPROVALS FOR THE
 OUTSWING FRONT DOOR WITH ONE SIDELIGHT. THE ONE
 SUBMITTED (JELD-WEN, FL 11136-R5) IS FOR A SINGLE DOOR
 WITH NO SIDELIGHTS. PROVIDE TWO SETS OF PRODUCT
 APPROVALS FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC
 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE
 BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER
 OF RECORD.
  
 8) FBC ENERGY CONSERVATION SECTION R103.1.1 REQUIRES
 THE OWNER/AGENT TO SIGN AND DATE ENERGY FORM R405-2014.
  
 9) THE ENERGY FORM R405-2014, CONTAINS SOME ERRORS. THE
 SQUARE FOOTAGE OF CONDITIONED SPACE SHOULD BE 2163. THE
 NUMBER OF BEDROOMS IS 4. THE ADDRESS OF THE PROJECT IS
 SHELLY ROAD, WEST PALM BEACH FL.
  
 10) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT
 A RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW
 COMMENTS HAS BEEN ADDRESSED.
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-12-18 Cont ID  
Sent By jpearson Date 2017-12-18 Time 16:19 Rev Time 0.00
Received By jpearson Date 2017-12-18 Time 16:12 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2017-10-02 Cont ID  
Sent By fgiaquin Date 2017-10-02 Time 11:02 Rev Time 0.00
Received By fgiaquin Date 2017-10-02 Time 10:46 Sent To  
Notes
2017-10-02 11:01:33THIS PLAN HAS BEEN PASSED PROVISIONALLY:
  
 FOR FINAL INSPECTION:
 1. PROVIDE ACCURATE LOAD CALCULATION AND PANEL
 SCHEDULE. LOAD CALCULATION ONLY SHOWS 1 SMALL APPLIANCE
 CIRCUIT IN KITCHEN, MINIMUM OF 2 IS REQUIRED. NEC
 210.52 (B1) NEC 220.52 (A).
 GENERAL LIGHTING IS NOT A SUFFICIENT DESCRIPTION FOR
 CIRCUITS ON THE PANEL SCHEDULE.
  
 FOR ROUGH INSPECTION:
 1. MINIMUM OF 2 SMALL APPLIANCE CIRCUITS FOR KITCHEN.
 NEC 210.52 (B1) NEC 220.52 (A)
  
 2.WP/GFCI RECEPTACLE REQUIRED ON FRONT OF DWELLING NEC
 210.52(E1)
  
 3. NEED RECEPTACLE IN FOYER NEC 210.52(A2)
  
 4. NEED GFCI RECEPTACLE WITH 3 FEET OF SINK IN BATHROOM
 ATTACHED TO BEDROOM #1.
  
 5. ATTIC ACCESS NEEDS A LIGHT AND SWITCH NEC 210.70
 (A3)
  
 6. SMOKE ALARM OUTSIDE OF BEDROOMS #1&2 MUST BE A
 SA/CMD. FBC R315
  
 PLAN HAS BEEN MARKED ACCORDINGLY WITH CORRECTIONS.
  
  
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION,
 PART VIII ELECTRICAL
 NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 FRANK GIAQUINTO
 ELECTRICAL INSPECTOR
 ELECTRICAL PLANS EXAMINER
 CITY OF WPB
 DEVELOPMENT SERVICES DEPT.
 CELL 561-657-1653
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2018-02-20 Cont ID  
Sent By cpuell Date 2018-02-20 Time 15:35 Rev Time 0.00
Received By cpuell Date 2018-02-13 Time 11:08 Sent To  
Notes
2018-02-14 11:08:27RESUB ROUTED TO LLOUIE VIA ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-01-29 Cont ID  
Sent By cpuell Date 2018-01-29 Time 13:10 Rev Time 0.00
Received By cpuell Date 2018-01-23 Time 11:40 Sent To  
Notes
2018-01-24 11:41:03RESUB ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-12-21 Cont ID  
Sent By rmcdouga Date 2017-12-21 Time 18:16 Rev Time 0.00
Received By rmcdouga Date 2017-12-01 Time 14:41 Sent To  
Notes
2017-12-04 14:41:30R08

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-10-19 Cont ID  
Sent By rmcdouga Date 2017-10-19 Time 17:12 Rev Time 0.00
Received By rmcdouga Date 2017-09-26 Time 12:58 Sent To  
Notes
2017-09-27 12:59:11R08

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2018-02-27 Cont ID  
Sent By rmcdouga Date 2018-02-27 Time 11:21 Rev Time 0.00
Received By rmcdouga Date 2018-02-27 Time 11:21 Sent To  
Notes
2018-02-27 11:24:28MU-2017-28997, PAID $10,003.08

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2017-12-21 Cont ID  
Sent By rmcdouga Date 2017-12-21 Time 15:53 Rev Time 0.00
Received By rmcdouga Date 2017-12-21 Time 15:53 Sent To  
Notes
2017-12-21 15:54:24SUBMIT A COPY OF THE PAID RECEIPT FOR THE IMPACT FEES.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2017-10-18 Cont ID  
Sent By rmcdouga Date 2017-10-18 Time 16:17 Rev Time 0.00
Received By rmcdouga Date 2017-10-18 Time 16:16 Sent To  
Notes
2017-10-18 17:19:35BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2017-12-21 Cont ID  
Sent By rmcdouga Date 2017-12-21 Time 15:55 Rev Time 0.00
Received By rmcdouga Date 2017-12-21 Time 14:51 Sent To  
Notes
2017-12-21 15:56:00APPROVED WITH EXCEPTION. RED LINED THE CORRECTIONS ON
 THE PLANS.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-10-19 Cont ID  
Sent By rmcdouga Date 2017-10-19 Time 16:46 Rev Time 0.00
Received By rmcdouga Date 2017-10-19 Time 16:24 Sent To  
Notes
2017-10-19 16:46:41PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY MECHANICAL
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE EQUIPMENT INFORMATION ON FORM R405-2014 DOES NOT
 MATCH THE EQUIPMENT SIZING CALCULATIONS OR THE
 MECHANICAL PLANS. FBC-R103.2
  
 2) THE RETURN AIR TRANSFER DUCT FOR THE MASTER BEDROOM
 SUITE IS UNDERSIZED. ALL SUPPLY AIR INTO THE MASTER
 SUITE SHALL BE INCLUDED WHEN CALCULATING THE TRANSFER
 DUCT SIZING. FBCR-M1602.4
  
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2017-10-04 Cont ID  
Sent By thunt Date 2017-10-04 Time 15:22 Rev Time 0.00
Received By thunt Date 2017-10-04 Time 15:22 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 4 Status P Date 2018-02-20 Cont ID  
Sent By llouie Date 2018-02-20 Time   Rev Time 0.00
Received By llouie Date 2018-02-16 Time 11:00 Sent To PC
Notes
2018-02-20 13:39:04ZONING APPROVED WITH THE FOLLOWING PROVSIOS:
  
 1.) NEW DRIVEWAY SHALL NOT EXCEED 20 FT. IN WIDTH.
  
 2.) SEPERATE PERMIT APPLICATIONS AND REVIEWS WILL BE
 REQUIRED FOR: LANDSCAPE AND DRIVEWAY PRIOR TO THE
 ISSUANCE OF A CERTIFICATE OF OCCUPANCY.
  

Review Stop Z ZONING
Rev No 3 Status F Date 2018-01-26 Cont ID  
Sent By LL Date 2018-01-26 Time   Rev Time 0.00
Received By llouie Date 2018-01-25 Time 11:30 Sent To I
Notes
2018-01-26 16:03:09** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 1.) THE DIMENSIONS PROVIDED IN THE LATEST SURVEY,
 SHOWING THE PROPOSED NEW SINGLE-FAMILY STRUCTURE DOES
 NOT MATCH THE DIMENSIONS PROVIDED IN THE SITE PLAN.
  
 2.) THE LOCATION AND SETBACKS OF THE NEW A/C UNIT IS
 INCONSISTENT IN THE SURVEY AND SITE PLAN. PLEASE
 ADDRESS FOR CONSISTENCY.
  
 NOTES:
  
 * SEPARATE PERMIT APPLICATIONS AND REVIEWS WILL BE
 REQUIRED FOR: LANDSCAPE AND DRIVEWAY PRIOR TO THE
 ISSUANCE OF A CERTIFICATE OF OCCUPANCY.
  
 * REVISIONS MAY RESULT IN ADDITIONAL COMMENTS.
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.
  
 * ZONE: SPENCER LAKES RPD (USE SF7 REGULATIONS PER
 AVANN).

Review Stop Z ZONING
Rev No 2 Status F Date 2017-12-11 Cont ID  
Sent By LL Date 2017-12-11 Time   Rev Time 0.00
Received By llouie Date 2017-12-11 Time   Sent To  
Notes
2017-12-11 16:43:59** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 1.) CLEARLY SHOW THE SETBACK DIMENSIONS FROM THE
 SHORTEST POINT OF THE BUILDING TO THE PROPERTY LINES
 (I.E. FRONT, INTERIOR SIDE, CORNER SIDE AND REAR) IN
 THE SITE PLAN (SHEET S.P). PLEASE NOTE THAT THE
 DIMENSIONS SHOULD BE CONSISTENT WITH THE PROPOSED
 BUILDING SETBACKS PROVIDED IN THE SIGNED AND SEALED
 SURVEY.
  
 2.) PLEASE SHOW SETBACK DISTANCE FROM THE PROPOSED A/C
 UNIT PAD TO THE SIDE CORNER PROPERTY LINE. PLEASE NOTE
 THAT THE PAD CANNOT ENCROACH MORE THAN 4 FT. INTO A
 REQUIRED SETBACK. [ZLDR S.94-305(A)(4)]
  
 3.) CLEARLY SHOW THE DIMENSIONS OF THE DRIVEWAY ON THE
 SITE PLAN. THE DRIVEWAY SHALL NOT EXCEED 20 FT. IN
 WIDTH. [ZLDR S.94-312(1)]
  
 4.) 1,000 SQ. FT. OR 75 PERCENT OF THE REQUIRED FRONT
 YARD (THE AREA OF THE FIRST 25 FT. FROM THE FRONT
 PROPERTY LINE, SHELLEY ROAD N.) SHALL BE LANDSCAPED
 WITH LIVING PLANT MATERIAL (I.E. GRASS, GROUND COVER,
 SHRUBS, HEDGES, VINES OR TREES). PLEASE PROVIDE
 DIMENSIONS AND CALCULATIONS IN THE SITE PLAN TO
 DEMONSTRATE COMPLIANCE. [ZLDR S.94-482]
  
 5.) CLEARLY SHOW SETBACK DIMENSIONS FROM THE SHORTEST
 POINT OF THE DRIVEWAY TO THE SIDE CORNER PROPERTY LINE.
 THE DRIVEWAY MUST BE SETBACK A MINIMUM OF 5 FT. FROM
 THE SIDE CORNER PROPERTY LINE. [ZLDR S.94-482(D)]
  
  
  
 NOTES:
  
 * SEPARATE PERMIT APPLICATION AND REVIEW WILL BE
 REQUIRED FOR: LANDSCAPE AND DRIVEWAY PRIOR TO A
 CERTIFICATE OF OCCUPANCY.
  
 * REVISION MAY RESULT IN ADDITIONAL COMMENTS.
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.
  
 * ZONE: SPENCER LAKES RPD (USE SF7 REGULATIONS PER
 AVANN).
  
  
  
  

Review Stop Z ZONING
Rev No 1 Status F Date 2017-10-06 Cont ID  
Sent By njwira Date 2017-10-06 Time 11:09 Rev Time 0.00
Received By njwira Date 2017-10-05 Time 16:29 Sent To  
Notes
2017-10-06 11:19:4910/6/17- FAILED
  
 WHAT IS THE DRIVEWAY CURBCUT? CANNOT EXCEED 20FT.
 MUST PROVIDE 75% OR 1,000SQFT. OF PERVIOUS SURFACE IN
 THE FRONT SETBACK WHICH IS SHELLY RD.
 DRIVEWAY MUST HAVE A 5FT. SETBACK FROM THE CORNER LOT
 LINE AND INDICATED ON THE PLANS.
 WHERE IS THE A/C UNIT GOING?
  
  
 PLEASE CONTACT
 NATHAN WIRA- ZONING TECHNICIAN
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING AND ZONING
 DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS ST.
 WEST PALM BEACH, FL 33402
 OFFICE HOURS: M-F 8AM - 5PM
 (561)822-1442
 [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved