|
 |
 |
 |
 |
 |
Plan Review Details - Permit 17090494
| Plan Review Stops For Permit 17090494 |
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-10-16 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-10-16 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-10-11 |
Time |
09:07 |
Sent To |
|
|
| Notes |
| 2017-10-12 09:07:58 | RESUB ROUTED TO CCOLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-09-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-09-22 |
Time |
10:03 |
Sent To |
|
|
| Notes |
| 2017-09-25 10:03:55 | MECH <5K |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2017-10-16 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-10-16 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-10-16 |
Time |
14:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-09-29 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-09-29 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-09-29 |
Time |
10:10 |
Sent To |
|
|
| Notes |
| 2017-09-29 10:42:16 | 1ST REVIEW FBC-2014 RESIDENTIAL MECHANICAL, ENERGY | | | CONSERVATION | | | PERMIT #17090494 | | | 9/29/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) UNDER THE PROPOSED EQUIPMENT SCHEDULE PLEASE ADD THE | | | COOLING AND HEATING CAPACITIES OF THE SYSTEM, AND | | | SUBMIT AN AHRI CERTIFICATE- SECTION R101.4.7 FBC-14 | | | MECHANICAL. | | | | | | 2) SHOW THE AIRFLOW IN CFMS AT EACH DIFFUSER AND RETURN | | | GRILL- SECTION M1602.4 FBC-14 RESIDENTIAL. | | | | | | 3) PROVIDE STRUCTURAL DETAILS FOR INSTALLATION OF THE | | | CONDENSER PAD AND TIE DOWN OF THE UNIT- SECTIONS | | | M1305.1.4.1 & M1401.4. | | | | | | 4) THE ENGINEER'S LETTER AND THE ENERGY CALCULATIONS | | | ARE INDICATING THE NEW WINDOWS HAVE U-FACTORS OF 0.34 | | | AND SHGC OF 0.23, HOWEVER THE ORIGINAL PLANS UNDER | | | PERMIT #16100865 DO NOT INDICATE THESE VALUES. PLEASE | | | PROVIDE DOCUMENTATION FROM THE MANUFACTURER TO VERIFY | | | COMPLIANCE. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |